4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES



Similar documents
Smoke Detector PSD 2 & 4 Wire Units

DUCT SMOKE DETECTOR D4120

E-PDD Duct Smoke Detector Installation Sheet

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

D287/D288/D292/D293A/D293E

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

8900 EMR (WITH DETECTOR)

Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

DH100ACDCLWP Watertight Air Duct Smoke Detector with Extended Air Speed Range

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

Fire & Security DETECTORS

SECTION DETECTION AND ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

NFPA Edition Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

INSTALLATION AND MAINTENANCE INSTRUCTIONS I R

D4120 Duct Smoke Detector D4S Sensor Component D4P120 Power Board Component

CalMod Design-Build Electrification Services

SECTION FIRE ALARM AND DETECTION SYSTEMS

rpsa FIRE PROTECTION ENGINEERS

FIREDEX Conventional Fire Panels

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

conventional system operation

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

PIEZOMETER AIRFLOW MEASURING RING

EQUIPMENT SPECIFICATIONS

EMF/EMR. Holder/Release Devices with Integral Door Closers

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Release Control Fire Alarm Systems

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Module 5. Fire and Emergency Alarm System Part I- Basics

SECTION FIRE ALARM AND DETECTION SYSTEM

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Fire Pump Controllers Remote Alarm Panels

CB200W Water Leak Detection Panel Application Guide

BERMAD Fire Protection

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

ERS-2400B. PERS-2400B Personal Emergency Reporting System

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

FIRE ALARM SYSTEM RECORD OF COMPLETION

SILENT KNIGHT MODEL 5207

FIRE ALARM SYSTEM RECORD OF COMPLETION

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

TrueAlarm Fire Alarm Systems

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

TrueAlarm Fire Alarm Systems

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

HM-W536 Install Guide

Fire detection equipment

16720S01 - FIRE ALARM SYSTEM (HARDWIRED), MANUAL AND AUTOMATIC

FIRERAY 2000 Installation Guide

PowerCode Wireless. Fully supervised wireless system. Features

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

TS93 EMR T/PT/TDE. Surface applied door closer

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Design and Construction Standards SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

SPECIFICATION FOR A TOTAL FLOOD HFC-227ea CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE Cheetah Xi CONTROL PANEL SYSTEM

University of Houston Master Construction Specifications Insert Project Name

DTW Works Master Specification Version 2006

CAN/ULC-S Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

SLIM LINE FUME HOOD MONITOR

PowerLogic Sub Meter Display (SMD and SMDOPN)

FIRE DETECTION AND ALARM

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

ENGINEERING SPECIFICATIONS

v 1.42b Conceal-Alarm Information Packet for Fire Alarm System Contractors & Installers Conceal -Alarm

FIRE DETECTION/INERGEN SUPPRESSION SYSTEM ENGINEERING SPECIFICATIONS

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

HERNANDO COUNTY FIRE ALARM GUIDELINES

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Solid State Timers Type F

Lighting and Fire Alarm Training System Add-On

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

EDWARDS SIGNAL SOLUTIONS DISTRIBUTED BY: Lee Dan Communications, Inc. Toll-Free:

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

CO2 Alarm. Operation. Application

SECTION FIRE ALARM AND DETECTION SYSTEM

FIRE ALARM SYSTEM Section Page 1

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Life Alarm Fire Alarm Controls

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Transcription:

4-Wire Air Duct Smoke Detector Models DH-60 F-70.05 FEATURES Approvals/Listing UL 268A Listed File S1064 Factory Mutual Approved CSFM Listed #3240-1076:121 NYC MEA Listed #134-95-E City of Los Angeles Approved #RR8318 24/120/240 Vac or 24 Vdc Operation Compatible with Fenwal Advanced Smoke Detectors In-place Sensitivity Measurement (in % per foot obscuration) Remote Indication, Test and Reset Capabilities Easily Mounts to Round or Rectangular Ducts Wide Range of Duct Sizes and Air Velocities High Capacity Form C Alarm Relay Contacts Clear Lexan Cover for Easy Viewing of Smoke Detector Status and Cleanliness DESCRIPTION The Fenwal Series DH-60 Air Duct Smoke Detector is designed for detecting particles of combustion in air handling systems. The DH-60 Duct Detector housing accepts the Fenwal Advanced CPD-7054D Ionization and PSD- 7157D Photoelectric Smoke Detector Heads. Upon detection of smoke levels at the set point of the detector, the DH-60 Duct Detector can control a variety of devices, such as HVAC fans and dampers to prevent the spread of smoke throughout the facility. High amperage relay contacts are provided for controlling such devices in the event of a fire. Supervisory contacts are also provided for signaling unit faults. A transparent Lexan cover over the detection chamber allows visual inspection of the duct detector s chamber and the internal smoke detector status. Sampling is accomplished by sampling tubes that extend into the HVAC duct. The DH-60 Duct Detector can operate as a 24 Vac, 120 Vac or 240 Vac powered stand-alone device or as a 4- wire 24 Vdc powered device for use with Fire Alarm Control Panels. An integral normally energized trouble relay is used to supervise power and smoke detector head removal. Outputs provided can accommodate remote alarm and power indication, remote test and remote reset. Fenwal offers a range of remote accessories that operate in conjunction with the duct detectors. Figure 1 is a simplified parts breakdown of the DH-60 Air Duct Smoke Detector. TM Effective: May 2007 Protection Systems A UTC Fire & Security Company APPLICATION The Fenwal Series DH-60 Duct Detectors are suited for use with HVAC systems in commercial, industrial and institutional fire alarm applications. The DH-60 is easily mounted to both rectangular and round ducts from 8 inches (200 mm) to 12 feet (3.6 m) wide and is compatible with all ducts with air velocities between 500 and 4000 feet per minute (2.5 to 20 m/s). The Ionization and Photoelectric Smoke Detector heads listed above operate over this entire air velocity range. SAMPLING TUBES The operation of the DH-60 Duct Detector is based upon an air sampling principle. Two tubes extend into the HVAC duct to transport air from inside the duct into the duct detector sensing chamber and back out to the duct. If the sampled air contains a concentration of smoke greater than or equal to the alarm threshold of the internal smoke detector, the unit will alarm. The duct detector inlet supply sampling tube is selected according to the size of the HVAC duct. No exhaust tube is required. An exhaust tube is molded into the housing to simplify installation. REMOTE INDICATORS/CONTROLS A series of easily installed remote indicators are available to add versatility and flexibility to the Fenwal Series DH- 60 Duct Detectors. These attractive and functional devices provide convenient status information along with remote Test/Reset capabilities. The remote indicators are helpful when the detector is out of view or located in relatively inaccessible locations. The remote indicators can R

be used in both AC and DC applications. Figure 2 shows the faceplates of the RA 911 and RA 914 remote indicator controls. FUNCTIONAL TESTING AND SENSITIVITY MEASUREMENT The Fenwal DH-60 Duct Detectors should be tested upon installation and once a year thereafter as stated in NFPA 72. All alarm signal devices, releasing devices, and extinguishing systems, as applicable should be disengaged before the test is performed and re-engaged at the conclusion of testing. The DH-60 Duct Detector may be functionally tested either by introducing smoke into the detector or activating the magnet test. Two separate magnet-locating slots are provided on the outside of the duct detector housing. Further, as stated in NFPA 72, Detector sensitivity should be checked within one year of installation and every alternative year thereafter. Fenwal offers the Model DST-003 handheld wireless infrared sensitivity tester that allows the sensitivity of installed operating detectors to be measured from the floor level. For details, please refer Fenwal Document 06-236524-001. ENCLOSURE END PLUG COVER/TERMINAL DESIGNATION PLATE INLET TUBE (SUPPLY) DUCT DETECTOR MODEL DH-60 FENWAL EXHAUST TUBE (MOLDED INTO ENCLOSURE) MTG. SCREW AND O-RING DETECTOR VIEW PORT DETECTOR HEAD ION OR PHOTO COVER Figure 1. DH-60 Parts Breakdown POWER ALARM ALARM ALARM INDICATOR RESET TEST RESET TEST MODEL RA-911 REMOTE ALARM INDICATOR MODEL RA-912 REMOTE ALARM INDICATOR WITH REMOTE TEST AND RESET Figure 2. Remote Alarm Indicators MODEL RA-913 REMOTE POWER/ALARM INDICATOR WITH REMOTE TEST AND RESET - 2 -

TECHNICAL SPECIFICATIONS Tables 1 and 2 list the technical specifications of the DH-60 Duct Detector. Table 1: DH-60 Input Voltage and Current Ratings Power Source Voltage Range Standby Current No Accessories Alarm Current No Accessories Alarm Current Maximum Accessories 24 Vac 20.4-26.4 70 ma rms 160 ma rms 220 ma rms 120 Vac 120-132 30 ma rms 40 ma rms 50 ma rms 240 Vac 204-264 30 ma rms 26 ma rms 35 ma rms 24 Vdc 20-29 20 ma DC 60 ma DC 90 ma DC Table 2: DH-60 Relay Contact Ratings Contact Designation Type of Contacts Contact Rating 10 A @ 30 Vdc resistive Auxiliary Alarm Contact 2 Form C 10 A @ 277 Vdc resistive 1/8 HP @ 120 Vac 1/4 HP @ 240 Vac Alarm Initiation Contact 1 Form A 2 A @ 30 Vac/Vdc resistive Supervisory Contact 1 Form A (normally energized) 0.3 A @ 30 Vac/Vdc resistive Table 3: Remote Indicator Ratings Model Description Standby Alarm RA-911 Remote Alarm Indicator 0 ma 20 ma RA-912 Remote Alarm Indicator with Remote Test and Reset 0 ma 20 ma RA-913 Remote Power Alarm Indicator with Remote Test and Reset 0 ma 30 ma - 3 -

5 in. 127 mm DH-60 FENWAL 14-1/2 in. (368 mm) 2-1/2 in. (64mm) 6-3/4 in. (171 mm) Figure 3. DH-60 Dimensions Table 4: Ordering Information Part Number Model Description Duct Detector and Housings 70-600000-000 DH-60 4-Wire Duct Housing less Detector with Integral Exhaust Tube 70-600000-157 DH-60-APD DH-60 with Advanced Photoelectric Detector PSD-7157D 70-600000-054 DH-60-ACD DH-60 with Advanced Ionization Detector CPD-7054D Duct Detector Sampling Tubes 06-129500-001 12 in. (305 mm) Long Air Sampling Tube 06-129500-002 24 in. (610 mm) Long Air Sampling Tube 06-129500-003 48 in. (1219 mm) Long Air Sampling Tube 06-129500-004 72 in. (1829 mm) Long Air Sampling Tube 06-129500-005 96 in. (2438 mm) Long Air Sampling Tube 06-129500-006 120 in. (3048 mm) Long Air Sampling Tube 06-129554-001 Optional Exhaust Tube Assembly Duct Detector Accessories and Test Equipment 06-117883-001 Test Magnet 29-116788-001 EOL Supervisory Relay 70-500000-003 DST-003 Sensitivity Tester for Advanced CPD-7054D and PSD-7157D Heads - 4 -

Table 4: Ordering Information (Continued) Part Number Model Description Remote Indicators 70-200000-911 RA-911 Remote Alarm Indicator 70-200000-912 RA-912 Remote Alarm Indicator with Test and Reset 70-200000-913 RA-913 Remote Power and Alarm Indicator with Test and Reset Spare Parts 06-118012-001 Key for RA-912 and RA913 06-129498-001 4-Wire DH-60 Duct Detector Circuit Board 06-235201-001 06-235201-001 DH-60 Manual 70-540000-002 CPD-7054D Advanced Ionization Detector Head 71-570000-002 PSD-7157D Advanced Photoelectric Detector Head - 5 -

TM R This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. F-70.05 Rev AB 2007 Kidde-Fenwal Inc. Printed in USA Protection Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.fenwalfire.com