TIMBER FRAME STANDARD DETAILS SEPTEMBER 09



Similar documents
FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

POST AND FRAME STRUCTURES (Pole Barns)

Mark Cramer Inspection Services, Inc.

Timber Frame Construction

Leaky Homes Financial Assistance Package (FAP) Repair plan example

8/18/14. Introduction to. Framing. Terminology and Concepts

INSTALLATION. General. Important Note. Design. Transport

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Instruction Manual 19/9/01. Flat Roof Carport

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Best Barns USA Assembly Book

PRODUCT AND ENGINEERING MANUAL

How To Build A Gambrel Roof And A Gable End Roof

Chapter 6 ROOF-CEILING SYSTEMS

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

A description of the Listed Buildings in the Parish of Lower Penn

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE

CI/SfB 2- Rj7 December 2010

Residential Inspection Guidelines

2.1. Architectural Character. Mountain. Agrarian. Craftsman. Gold Rush

Standard Technical Details

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

March 14, Installation of Bay, Bow and Garden Windows

Rev Code of Practice. SIP Technology.

Building Construction. Lightweight construction. Conventional Construction

WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Roof Tutorial. Chapter 3:

SUPER SHED. Indoor shelter for your outdoor tools.

ANCHOR: Metal securing device embedded or driven into masonry, concrete, steel or wood.

Title: Attic Keyword: Structure Description: roof framing rafters and decking File Name: P

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

INSTALLATION INSTRUCTIONS

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Georgia Association of Home Inspectors

The WANZ Guide to Window Installation

RESIDENTIAL METAL BUILDING COMPONENTS

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

domestic structure SBSG 2007 ANNEX C

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Repair of Spalling and Leaking Clay Brick Building Walls

Vertex BD. Leading Software Solution for Cold Formed Steel Construction

Condition Report SAMPLE. Property address. Client s name. Date of inspection

H-Stud Area Separation Wall System

Installation Instructions

CHAPTER 6 CONSTRUCTION TYPES

Bungalow. Essential Elements. Prominent porch columns,

Building Condition Assessment Report

Solar Panel Installations

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

rationel WINDOWS WITH VISION

FLAT ROOF BOX SPAN CARPORTS

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012

Building Condition Assessment: North Howard Street Baltimore, Maryland

Rockwool Flexi Insulation Application Guide

EARTHQUAKE DESIGN OF BUILDINGS

Doughty Environmental Hygiene Associates

EAST LYME HIGH SCHOOL

Energy Company Obligation (ECO): Technical Monitoring Questions

Pole Building Estimate Number: /2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION

Building Control Guidance Note

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES

Superform Products Ltd.

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

David C. Barrow Elementary School 100 Pinecrest Drive, Athens, GA 30605

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Page & Turnbull imagining change in historic environments through design, research, and technology

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Inspecting to a higher standard.

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

THIS GUIDE WAS PREPARED BY THE CYCLONE TESTING STATION WITH SUPPORT FROM NORTHERN TERRITORY, QUEENSLAND AND WESTERN AUSTRALIAN GOVERNMENTS

Repairing storm damaged roofs

Residential Adjustments. Overview 4.1

Structural Assessment Report

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Ceiling Mounted Folding Attic Ladders Installation Instructions

Additions and Alterations

Excerpts from the Canadian National Building Code (NBC)

A Homeowner s Guide to Building Permits

FS Deck Mounted Skylight Installation Instructions 15-90

OSHA GUIDANCE DOCUMENT FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Which generic risk assessments are provided? Construction Risk. Assessments Plus. ervices

Building Regulations for the Conservation of Fuel and Power

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Holz Choices & Specifications

AMERICAN GOTHIC PLAYHOUSE

Sample Drawing Package for One and Two Family Dwelling Applications

DETAILS FOR CONVENTIONAL WOOD FRAME CONSTRUCTION

Transcription:

Building 1 Grosvenor Court, Hipley Street OLD WOKING, SURREY GU22 9LL Tel: +44 (0) 1483 769518 Fax: +44 (0) 1483 770863 E-mail: design@silvatecdesign.com Internet: www.silvatecdesign.com TIMBER FRAME STANDARD DETAILS SEPTEMBER 09

Details on Plan 1. External Wall 1.1. External corner 1.2. Re-entrant corner 1.3. Separating wall junctions 1.4. Non loadbearing wall junctions 1.5. Window/Door Jambs 1.6. Masonry Cladding 1.7. Tile hanging off timber frame 1.8. Timber boarding on timber frame 1.9. Render on timber frame 2. Internal Walls 2.1. Internal wall to internal wall junctions 3. Roofs 3.1. Access hatch 3.2. Tank stand and walkway 3.3. Trusses: 3.3.1. Standard truss 3.3.2. Raised tie truss 3.3.3. Attic truss 3.4. Bracing Diagonal and longitudinal 3.4.1. Bracing 3D 3.5. 3.5.1. Verge Details 3.5.2. Truss parallel to separating wall 3.5.3. Truss perpendicular to separating wall 3.5.4. Truss at right angles to each other at separating wall 3.6. Purlins Connections 3.7. Rafters 3.7.1 Rafters on floor deck 3.7.2 Rafters on dwarf wall 3.8. Roof panels 3.8.1 Roof panel connections 3.9. Flat roof Joist and decking 3.10. Dormer in Section 3.11. Dormer in Perspective view 3.12. Parapet detail joists perpendicular 3.13. Parapet detail joists parallel Details in Section 4. External Walls 4.1. Ground Floor 4.2. Intermediate floor Joist parallel 4.3. Intermediate floor Joist perpendicular 4.4. Compartment floor I Joist parallel 4.5. Compartment floor I Joist perpendicular 4.6. Top floor ceiling at eaves

4.7. Eaves at window head 4.8. Window Cill 4.9. Joinery head 4.10. Door threshold 4.11. Intermediate Floor Open Web Joist Parallel 4.12. Intermediate Floor Open Web Joist Perpendicular 4.13. Compartment Floor Open Web Parallel 4.14. Compartment Floor Open Web Perpendicular 4.15. Compartment Floor Solid joist Parallel 4.16. Compartment Floor Solid joist Perpendicular 4.17. Compartment Floor with Screed Joist Perpendicular 4.18. Compartment Floor with Screed Joist Parallel 4.19. Compartment Floor with Screedboard Joist Perpendicular 4.20. Compartment Floor with Screedboard Joist Parallel 5. Internal Walls 5.1. Ground floor - loadbearing partition 5.2. Ground floor non loadbearing partition 5.3. Ground floor Separating wall 5.4. Upper floor loadbearing partition 5.5. Upper floor Non loadbearing partition 5.6. 5.6.1 Upper floor Separating wall Compartment Floor I joist parallel 5.6.2 Upper floor Separating wall Compartment Floor I joist perpendicular 5.6.3 Upper floor Separating wall Intermediate Floor I joist parallel 5.6.4 Upper floor Separating wall Intermediate Floor I joist perpendicular 5.6.5 Upper floor Separating wall Intermediate Floor Open Web parallel 5.6.6 Upper floor Separating wall Intermediate Floor Open Web perpendicular 5.6.7 Upper floor Separating wall Compartment Floor Open Web parallel 5.6.8 Upper floor Separating wall Compartment Floor Open Web perpendicular 5.6.9 Upper floor Separating wall Compartment Floor Solid Joist parallel 5.6.10 Upper floor Separating wall Compartment Floor Solid Joist perpendicular 5.6.11 Upper floor Separating wall Compartment Floor with Screed joists parallel 5.6.12 Upper floor Separating wall Comp. Floor with Screed joists perpendicular 5.6.13 Upper floor Separating wall Comp. Floor with Screedboard joists parallel 5.6.14 Upper floor Separating wall C/Floor with Screedboard joists perpendicular 5.7. Ceiling 6. Door Linings 6.1. Internal Doors 6.2. External Doors 6.3. Party wall Entrance Doors 7. Services 7.1. Chimney External 7.2. Chimney - Internal 7.3. Specific limitations of notching and drilling joists 7.4. Specific limitations of notching and drilling studs 7.5. Electrical sockets in separating walls Shallow fitting 7.6. Electrical sockets in separating walls Deep fitting

7.7. Services in party floors 8. 8.1. Panel Plumb Fixing Detail 9. Air Leakage Details 9.1. Floor Junction 9.2. Internal to External Wall Junction 9.3. Electrical Sockets in External Wall 10. Manufacturing and Erection details 10.1. Wall Panel Assembly 10.2. Wall Panel connections 10.3. Floor Assembly 10.4. Sheet materials on joists 10.5. Temporary bracing

Silvatec Design Ltd Timber Frame Design and Structural Engineers Silvatec Levels Ltd Suppliers of Panel Plumb Unit 1 Grosvenor Court Hipley Street, Old Woking Surrey GU22 9LL Tel: 01483 769 518 Fax: 01483 770 863 Email: design@silvatecdesign.com