Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com

Similar documents
Temporary Power Outlet Panels

Power Outlet Panels. Product Guide

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Equipment. Metering. Metering Equipment 1. Contents

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) # kcmil SUK1000TA.

The Ultimate Load Center Features INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W. [previous page #: 2-18; 2-22]

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

IRRIGATION PUMPING Table of Contents - Section 900

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Type 1, 3, & 3R Enclosures

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Electrical Code Regulation

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

INSTALLATION INSTRUCTIONS

Electronic Watt-Hour Meters Catalog

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

EDS / EFS Series Control Stations

Electrical Service Guidelines

Generator DoCKInG StatIonS

8146/5 Series Breaker Panelboards

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Mini USB and USB 2.0-IP67 Connector System

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

For Models #6-5001, #6-7501, # & #10-12K1

Scepter PVC Molded Junction Boxes

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Product Guide. Low voltage grounding system. Answers for industry.

Linear Luminaire with LED Series EXLUX 6402/2

Aluminium Standard. Technical Data. Included in delivery

Utility Distribution Systems

STB Series Enclosures

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

TSn SERIES Surge Protective Device

Retail Reference Guide Answers for infrastructure.

Grounding & Bonding Why it is done And How to Install Properly

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

HL Series - Commercial Heaters Tankless Water Heating Solutions

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

Scraper Passage Indicator. Electrical Indicator. Features

MOBILE HOME SERVICE REQUIREMENTS GAS

IEC 309 INTERLOCKS NORTH AMERICAN

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Distribution Dry Type Transformers

INSTALLATION & SERVICE MANUAL. Display Panel

TERMINATION ENCLOSURE OPTIONS

JIC CONTINUOUS HINGE BOXES

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

Cable/Conduit Conversion

Section 5 Meters and Service Entrance Equipment

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Mobile Home Pre-Inspection Checklist

Top Commercial / Residential Electrical Requirements *

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

EDS / EFS Series Control Stations

Electrical Grounding. Appendix C

Mazda CX up B

RAY-MAX Integrated Solar Power Strip

ELECTRICAL CONNECTORS

Evolve LED Area Light

Power Distribution & Terminal Blocks

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

SECTION LOW VOLTAGE LIGHTING CONTROLS

Diesel Engine Driven Generators Page 1 of 6

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

VS CONTROL PACK INSTALLATION INSTRUCTIONS

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Low Voltage Transformers Sealed, General Purpose, Dry Type

F-Series Camera Mounting Accessories

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Toroidal Conductivity Sensor

Transcription:

Temporary Power Outlet Panels Selection and Application Guide www.talonmetering.com

2012 Siemens Industry, Inc. www.talonmetering.com Talon meter mounting equipment For more than half a century, Talon has been the market leader in innovation and value for the meter socket industry. From our award-winning HQ series lever bypass products, to proprietary K base products, to our new innovative temporary power outlet panel design, Talon is the long-term solution partner for your metering needs. Ask your local agent about the full line of utility approved devices available in your area, including Meter Sockets, Meter Combos, Temporary Power Devices, Spa Panels, Air Conditioning Disconnects and more. Note: approvals and offerings may vary by location. More details at our website: www.talonmetering.com

Talon s line of power outlet panels are designed to meet the demands for temporary power at construction sites and recreational vehicle (RV) parks. For construction site applications power outlet panels are installed for temporary use only until electrical power is available at the site providing a safe and reliable source of power. Recreational Vehicle parks use power outlet panels on a permanenet basis as a power source for the RV s distribution system. RV park applications will frequently need power outlet panels with additional features such as light, water, phone and television options. Contents Metered devices 2 Un-Metered devices 3 Build your own catalog numbering system 4 Most common items 5 Dimension drawings 6 10 A wide variety of configurations are available to address almost any application. Surface and Pedestal mount units can be configured with light kits, photocells, main breaker disconnects, and custom colors. Utility grade metering can also be included and can be configured in top (surface mount units only) or bottom feed in ring or ringless styles with horn and lever bypass* options. Construction & Ratings Enclosure All enclosures are NEMA type 3R rated, conform to UL standard 50, and are fabricated using G90 galvanized steel & coated with a baked-on polyester powder coating. All devices are theft resistant by use of padlock provisions and an elevated deadfront design to prevent unauthorized access to receptacles and breakers. All surface mount enclosures have five mounting points, including a keyhole provision in the center. All metered devices are equipped with stainless steel latches & hasps. Interior Tin-plated bus bars are mounted on a thermoplastic interior designed for extended life & rated for up to 125 amps. All wiring is factory installed using copper wire. Receptacles are impact-resistant, commercial grade, and conform to NEMA and/or ANSI configurations as specified by the NEC. All breakers are Siemens QP or QPF (GFCI) type with a maximum of 50 amps per breaker. Meter sockets are utility grade, rated up to 125 amps, and conform to UL standard 414. All units are suitable for use as service entrance equipment and include a factory installed neutral bar with provisions for bonding when required. Each device carries a short circuit rating of 10,000 amps. Devices with 2 factory installed receptacles where one of the receptacles is 120V feature a 3 circuit interior. Devices with more than 2 factory installed receptacles or where 2 or more of the receptacles are 240V rated feature an 8 space, 16 circuit interior. Applicable US Standards UL231 (power outlet panels), UL67, UL414 & UL50. Options Light kit uses a LED based light bulb. Bulb ratings are: 120V AC, 21 lm (Lumens), 0.8W, & true white emitting color (color temp 4800K to 5200K). All bulbs are long life (100,000+ hours), solid state, & vibration resistant. Photocells are internally mounted for extra security, operate at 120V AC, turn on when light levels reach 1-5 footcandles and turn off when light readings reach 3-15 footcandles. *Lever bypass available in only top feed, surface mount configurations. 1

TL Series Temporary Power Outlet Panels Metered Devices Surface Mount Type Features 125 ampere rating 350 kcmil line side lugs Ring or ringless style covers Horn or lever bypass options Top and bottom feed options Factory installed light kit Factory installed photocell Stainless steel latch and hasp Easy to open and close receptacle cover Pole-mounted water and CATV/phone kits High quality Siemens loadcenter interior and breakers Pedestal Mount Types Features 125 ampere rating Ring or ringless style covers Single and back-to-back configurations 350 kcmil loopfeed lugs (back connected) Horn bypass option Direct burial and pad mount options Factory installed light kit Factory installed photocell Stainless steel latch and hasp Easy to open and close receptacle cover Pole-mounted water and CATV/phone kits High quality Siemens loadcenter interior and breakers 2

Un-Metered Devices Features 125 ampere rating Loop feed models available Factory installed light kit Factory installed photocell Easy to open and close receptacle cover Slim design for 2 receptacle devices (7 wide) High quality Siemens loadcenter interior and breakers Features 125 ampere rating 350 kcmil loopfeed lugs (back connected) Single or back-to-back configurations Direct burial or pad mount options Factory installed light kit Factory installed photocell Easy to open and close receptacle cover Externally attached water and CATV/phone kits High quality Siemens loadcenter interior and breakers Pad Mount Direct Burial Pedestal Mount Flange Kit 3

Temporary Power Outlet Panels Build Your Own Catalog Numbering System Follow the table below to configure a custom catalog number. Contact your local Talon agent or Siemens sales office for price and lead time. User assumes all responsibility for selecting proper configuration. T Talon Temporary Power Main Type L Main Lugs, 125A Main Breaker, B 125A Main Breaker, D 100A a Required fields. b A minimum of 1 receptacle must be selected. A maximum of 3 receptacles, with up to 125amps total, may be selected. UL does not allow field installation of receptacle kits. c Two receptacle devices ship in a 7" wide enclosure and are wired with a 3 circuit interior. Depending on the receptacle configuration selected an additional circuit may or may not be available d Enclosure includes same loop feed lugs as the pedestal devices. Enclosure is larger. Please see knockout diagrams for details. e Dash is only present if one of the options listed after the dash is needed. f Light kits are installed by the factory and require either a 120V GFCI breaker or 5-20RGFI receptacle to power the light fixture. Cable TV, phone, & water accessories are purchased separately and are not configured as part of the device. Photocell is factory wired and is mounted internally. 120V AC photocell only. "X" designates alternate receptacle configuration on each side. Contact sales office for pricing. Receptacles (3 max) 1 14-50R 125/250V 50A Designates GFCI Circuit Breaker 1F Protection 2 14-30R 125/250V 30A Designates GFCI Circuit Breaker 2F Protection 3 TT30R 125V 30A Designates GFCI Circuit Breaker 3F Protection 4 L6-30R 250V 30A Designates GFCI Circuit Breaker 4F Protection 5 6-20R 250V 20A Designates GFCI Circuit Breaker 5F Protection 6 L5-20R 125V 20A Designates GFCI Circuit Breaker 6F Protection 7 5-20R2GFI 125V 20A 7X Designates non-weatherresistant GFCI receptacle 8 5-20R2 125V 20A Designates GFCI Circuit Breaker 8F Protection 8G Designates weather resistant receptacle with GFCI Circuit Breaker Protection 9 L-530R 125V 30A 9F Designates GFCI Circuit Breaker Protection Meter/Bypass U R N Unmetered Ringless, No Bypass Ring, No Bypass L* Ringless, Lever Bypass H Ringless, Horn Bypass *Lever bypass available only in surface mount, topfeed configurations Enclosure Type Surface mount, S un-metered Surface mount, S2 d un-metered, loop feed lugs surface mount, T top feedmetered surface mount, B bottom feedmetered Direct burial P pedestal Pad mount M pedestal Direct burial 2P pedestal, double-sided Pad mount pedestal, double 2M sided Custom Options g L Light kit factory installed Light kit with LP photocell factory installed Alternate receptacle X configuration on double-sided pedestal Custom color Cx configuration Custom Color Guidelines: Cx" designates custom color. Contact sales office for color code to insert into part number to replace the "x" in this designation. Additional charges apply and depend on the color needed. Custom color matching available: Customer must signoff on painted sample prior to production of order. Order cancellations will involve a fee after custom paint is ordered. Given specifications: 125A Main Lugs 50A, 125/250V receptacle with GFCI circuit breaker 30A, 125V receptacle with a standard circuit breaker 20A, 125V GFCI weather resistant receptacle Ring type meter at the top Pedestal mount device Light option with photocell Example: Catalog Number: TL1F37NT-LP Step 1 Start with the power receptacle product line prefix identifier and choose the main type: (TL) Step 2 Choose the first receptacle and its circuit breaker type: (1F) Step 3 Choose the second receptacle and its circuit breaker type: (3) Step 4 Choose the third receptacle and its circuit breaker type: (7) Step 5 Choose utility meter & bypass type required: (N) Step 6 Choose enclosure type: (T) Step 7 Add dash and select light option with photocell: (-LP) Installer responsible for ensuring utility and local code acceptance 4

Temporary Power Outlet Panels Most common items See previous page to build your own catalog number Old Catalog Numbera New Catalog Number Mains Type Enclosure Type Meter Provision Receptacle #1c Receptacle #2c Receptacle #3c Options Surface Mount, Un-Metered P17US TL17US 125A Main Lug Surface Mount Un-Metered 14-50R 5-20R2 GFI W.R. N/A N/A P37US TL37US 125A Main Lug Surface Mount Un-Metered TT30R 5-20R2 GFI W.R. N/A N/A P77US TL77US 125A Main Lug Surface Mount Un-Metered 5-20RGFI W.R. 5-20R2 GFI W.R. N/A N/A P137US TL137US 125A Main Lug Surface Mount Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A P577US TL577US 125A Main Lug Surface Mount Un-Metered 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P1F7US TL1F7US 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr 5-20R2 GFI W.R. N/A N/A P1F3F7US TL1F3F7US 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A P5F8F8FUS TL5F8G8GUS 125A Main Lug Surface Mount Un-Metered 6-20R, GFCI Brkr 5-20R2, GFCI Brkr, 5-20R2, GFCI W.R. Brkr, W.R. N/A NA TL1F3F7US2 125A Main Lug Surface Mount Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. Loop Feed Lugs Surface Mount, Metered P77TS TL77NTb 125A Main Lug Top Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77BS TL77NBb 125A Main Lug Bottom Feed Metered- Ring 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77RTS TL77RTb 125A Main Lug Top Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P77RBS TL77RBb 125A Main Lug Bottom Feed Metered- Ringless 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A N/A P137RTS TL137RTb 125A Main Lug Top Feed Metered- Ringless 14-50R TT30R 5-20R2 GFI W.R. N/A P577TS TL577NT 125A Main Lug Top Feed Metered- Ring 6-20R 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P1F77TS TL1F77NT 125A Main Lug Top Feed Metered- Ring 14-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P1F77RBS TL1F77RB 125A Main Lug Bottom Feed Metered- Ringless 14-50R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77TS TL5F77NT 125A Main Lug Top Feed Metered- Ring 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77RTS TL5F77RT 125A Main Lug Top Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A P5F77RBS TL5F77RB 125A Main Lug Bottom Feed Metered- Ringless 6-20R, GFCI Brkr 5-20R2 GFI W.R. 5-20R2 GFI W.R. N/A NA TB137HT 125A Main Breaker Top Feed Pedestal Mount, Metered & Un-Metered Metered- Ringless with Horn Bypass 14-50R TT30R 5-20R2 GFI W.R. N/A P137UP TL137UP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A P137TP TL137NP 125A Main Lug Burial Pedestal Metered-Ring 14-50R TT30R 5-20R2 GFI W.R. N/A P1F3F7UP TL1F3F7UP 125A Main Lug Burial Pedestal Un-Metered 14-50R, GFCI Brkr TT30R, GFCI Brkr 5-20R2 GFI W.R. N/A P138FUP TL138GUP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2, GFCI Brkr, W.R. N/A NA TL137UP-LP 125A Main Lug Burial Pedestal Un-Metered 14-50R TT30R 5-20R2 GFI W.R. Light & Photocell P137U2B TL137U2P 125A Main Lug Burial Pedestal- Double Sided Un-Metered 14-50R TT30R 5-20R2 GFI W.R. N/A Special Accessories Catalog Number Description Notes TLAWATERd Water Connection Accessory Accessories are intended to mount on each side of a direct burial or pad mount pedestal. These accessories can be used independently provided they are mounted on a flat surface. TLATVP Television & Phone Connection Accessory Mounting these accessories to round poles is not recommended. TLALFB Loopfeed Replacement Block Includes (1) assembly. Replacement only. TLA0816LG Replacement interior for 10 wide devices Replacement Only TLAMS200 TL Series Meter Socket Replacement Only TLABULB TL Series Light Bulb Replacement Only TLAPC120V TL Series Photocell Replacement Only P prefix may also be PM or LGP. Cross reference is the same. b Stocked item. Status subject to change without notice. c NEMA receptacle configurations listed. d Accessory consists of trough only. User must install pipe and water connection point. 5

Temporary Power Outlet Panels Generic Accessories & Dimension Drawings Generic Accessories Accessory Talon Catalog Number Siemens Catalog Number 1.25" Hub H38597-2 EC38597 1.50" Hub H38598-2 EC38598 2.00" Hub H38599-2 EC38599 2.50" Hub H38600-2 EC38600 Hub Opening Closure Plate H38595-1 EC38595 5th Jaw Kit H659-0121 EC659-0121 5th Jaw Kit- Lever Bypass H38515-2 ------- Sealing Ring- Screw Type H9738-8002 SRSW Sealing Ring- Snap Type H56402 SRSTD Meter Opening Cover Plate H659-0162 ECPP Meter Bypass (Temporary Use Only) H36479 ECJS Unmetered Surface Mount, 7"wide Enclosure size for un-metered devices with two receptacles only. Unmetered Surface Mount, 10" wide Enclosure size for un-metered devices with3 receptacles. 6

Temporary Power Outlet Panels Dimension Drawings Unmetered Surface Mount, 10"wide with Loop Feed Lugs Enclosure size for 1-3 receptacles. Metered Top Feed Surface Mount Ring/ringless - no/horn bypass Metered Bottom Feed Surface Mount Ring/ringless - no/horn bypass Meterd top feed lever bypass surface mount 7

Temporary Power Outlet Panels Dimension Drawings Metered Pedastal Direct Burial Unmetered Pedastal Direct Burial Metered Pedastal Direct Burial Back to Back Unmetered Pedastal Direct Burial Back to Back 8

Temporary Power Outlet Panels Dimension Drawings Metered Pedastal Pad Mount Unmetered Pedastal Pad Mount Metered Pedastal Pad Mount Back to Back Unmetered Pedastal Pad Mount Back to Back 9

Temporary Power Outlet Panels Dimension Drawings Catalog Number: TLAWATER Water Kit Catalog Number: TLATVP Television & Phone Combination Pad Mount Bolt Pattern 10

Notes:: 11

Notes:: 12

13

Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com Subject to change without prior notice Order No.: RPSA-S0003-1012 All rights reserved Printed in USA 2012 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. www.talonmetering.com