1. Define the System SDV BDV SDV SDV SDV BDV SDV SDV SDV SDV SDV SDV. Process System TO FLARE TO FLARE BDV TO FLARE



Similar documents
Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

Jump Start: Storage Tank Protection in Aspen HYSYS and Aspen Plus

EMERGENCY VESSELS BLOWDOWN SIMULATIONS

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Jump Start: Aspen HYSYS Dynamics V7.3

Select the Right Relief Valve - Part 1 Saeid Rahimi

VAD. Variable Area Desuperheaters

EUROPEAN CHEMCAD SYMPOSIUM 1999

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Setting your session preferences

Water hammering in fire fighting installation

CO MPa (abs) 20 C

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

Calculating Volatile Organic Compounds (VOC) Flash Emissions from Crude Oil and Condensate Tanks at Oil and Gas Production Sites

A practical guide to restrictive flow orifices

Contents and Nomenclature

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Optimize Pipeline Hydraulics with Multiphase Flow Modeling

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Liquid level measurement using hydrostatic pressure and buoyancy

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

A Table of the Most Common Standard Pipe Sizes. Nominal Bore 1/2 inch (DN 15 mm), Outside Diameter mm

The Unique Accelabar Flow Meter

NFPA : Basic Requirements for Storage Tanks

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

UNIT 2 REFRIGERATION CYCLE

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

How To Design A Refrigeration System

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Air Eliminators and Combination Air Eliminators Strainers

Pressure Drop Basics & Valve Sizing

Chokes. Types Reasons Basics of Operations Application

Aspen Plus. User Guide Volume 2. User Guide V O L U M E 3. Version STEADY STATE SIMULATION. AspenTech

OSHA Tank Venting DEFINITIONS

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

Exergy Analysis of a Water Heat Storage Tank

Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers

Chapter 3. Table E-1. Equilibrium data for SO 2 at 1 atm and 20 o C. x y

Heating Water by Direct Steam Injection

INTRODUCTION TO FLUID MECHANICS

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

C. starting positive displacement pumps with the discharge valve closed.

Inert Gas Extinguishing System Two Minute Discharge Study. Gene Hill, P.E. Brad Stilwell

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment

PIPING WORKBOOK. Solving Piping and Header Networks Using CHEMCAD. Version 6.2

Simulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals

Engineering Problem Solving as Model Building

Steady Heat Conduction

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Desuperheater Online Program Sizing Guidance

Optimizing Flare System Performance at the Valero Sunray Refinery

Comparison of Emission Calculation Methodologies for the Oil and Gas Industry. Presented by: Leanne Sills

Chapter. Flares and Stacks. Flares (FLR) Stacks (STK) G2 ICARUS Corporation, 1998.

HS-901(A) BASIC STEAM HEATING SYSTEMS

NATIONAL RESEARCH COUNCIL CANADA. DIVISION OF BUILn ING RESEARCH DESIGN OF EXPOSED SEWER PIPES FOR INTERMITTENT USE UNDER FREEZING CONDITIONS

API Flanged Safety Relief Valves Series 526 CATALOG

The Behaviour Of Vertical Jet Fires Under Sonic And Subsonic Regimes

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Mechanical Seal Piping Plans

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Flashing and Cavitation

ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Abaqus/CFD Sample Problems. Abaqus 6.10

Pressure and Temperature Controls

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Calculating Heat Loss by Mark Crombie, Chromalox

Column Design. Gavin Duffy School of Electrical Engineering Systems DIT, Kevin Street

How To Calculate The Performance Of A Refrigerator And Heat Pump

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

CONTROL VALVE PRESSURE DROP AND SIZING

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Fired Heater Design and Simulation

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

Steam System Best Practices Condensate System Piping

EAGLE ASSET TRACKING DATABASE

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

API Standard Guide for Pressure-Relieving and Depressuring Systems

Automatic Self-Cleaning Strainers

Figure 56. Simple mixing process with process specification for the outlet stream.

Twin Screw Technology. General Overview and Multiphase Boosting 11/2013. Calgary Pump Symposium 2013

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Dynamic Process Modeling. Process Dynamics and Control

Model DE-3 Air Release Head

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

REFRIGERATION (& HEAT PUMPS)

VAD Variable Area Desuperheaters

Transcription:

1. Define the System BDV TO FLARE BDV SDV TO FLARE SDV SDV BDV TO FLARE SDV SDV SDV SDV SDV SDV 2 SDV

2. Calculate each system volume inventory ; both piping and equipment. Example : Piping Inventory Calculation Length Equival Internal Equivale Pipe Piping Vapour Liquid ent El. NPS Diamete nt Schedul Volume From To r Length fraction Volume Ratio e (ft) (ft) (inch) (inch) (ft) (ft 3 ) (ft 3 ) 3P-SDV-0013 5000-V-60 161.7 1.2 0.0 4 S40 4.026 199.17 17.607 0.8077 3.3859 5000-V-60 5000-PSV-V-60 3.3 1.3 0.0 2 S80 1.939 4.26 0.087 1.0000 0.0000 3"-300# Valve 4"-B1-PHL-100 16.4 1.3 0.0 3 S80 2.901 21.32 0.979 1.0000 0.0000 5000-V-60 5000-PSE-V-60 32.1 1.3 0.0 2 S80 1.939 41.71 0.855 1.0000 0.0000 5000-V-60 Reducer 3" x 2" 5.2 1.3 0.0 3 S40 3.069 6.82 0.350 1.0000 0.0000 Reducer 3" x 2" 3P-BDV-0016 10.2 1.3 0.0 2 S40 2.067 13.22 0.308 1.0000 0.0000 Reducer 3" x 2" 3P-PV-0023 3.7 1.3 0.0 3 S80 2.901 4.81 0.221 1.0000 0.0000 3"-GP-3P-022-BA1 VALVE 5.2 1.3 0.0 3 S40 3.069 6.82 0.350 1.0000 0.0000 2"-B1-BD-202 3P-PV-0022 16.1 1.3 0.0 2 S40 2.067 20.89 0.487 1.0000 0.0000 2"-B1-BD-202 VALVE 5.6 1.3 0.0 2 S80 1.939 7.25 0.149 1.0000 0.0000 5000-V-60 3P-SDV-0015 20.5 1.3 0.0 2 S80 1.939 26.65 0.546 0.0000 0.5465 5000-V-60 3P-SDV-0014 4.3 1.3 0.0 2 S80 1.939 5.54 0.114 0.0000 0.1137 Total 22.0543 4.0461 Example : Equipment Inventory Calculation ID Length Orientation HLL NLL LLL Volume HLL NLL LLL Total Wetted Wetted Wetted Tag Number Equipment Name Total HLL NLL LLL Area Area Area Area (ft) (ft) (ft) (ft) (ft) (ft 3 ) (ft 3 ) (ft 3 ) (ft 3 ) (ft 2 ) (ft 2 ) (ft 2 ) (ft 2 ) 5000-V-60 HP TEST SEPARATOR 2.500 12.000 HORIZONTAL 2.00 0 Total 0.75 0 0.50 0 62.9 54.1815.74 8.812 95 3 6 71.849 36.811 29.174 104.065 63.0 54.1815.74 8.812 0 3 6 71.849 36.811 29.174 104.065 3

4

Tool Utilities 1. Adjust massflow of related stream to achieve volume flow correspond to inventory calculation 2. Mix those stream, the result is as BASIS COMPOSITION 3. Balance it to initial pressure condition, the result is as BASIS SIMULATION Initial condition as follow : # FIRE at design pressure or PAHH # ADIABATIC at operating pressure 4. Tool/ Utilities or CTRL+U *) The higher the initial pressure, the grater the flowrate load to flare.. Because the time is set 15 minutes No matter the initial pressure 5 *) want to know more HYSYS short cut? check in my blog : www.process-eng.blogspot.com Article : useful HYSYS shortcut

1. Depressuring Dynamic 2. Add Utility 3. View Utility 6

7

re name to : FIRE CASE Select stream BASIS SIMULATION : FIRE Select vertical vessel HYSYS model the entirely system volume as a vertical cylinder with flat both bottom and top. keep as it is Automatically calculated by HYSYS But, You can manually fill to apply some margin of total inventory volume Fill volume of liquid Based on NLL or HLL 8 HYSYS will adjust vessel size both Diameter and Height so that both the total and liquid volume are correct correspond to the input value. Is it difficult to achieve that volume? As a matter of fact, it is not. Actually, the real problem is, the wetted area based on HYSYS s vessel size is not equal with the actual wetted area. HHL result worst case. Still remember the heat input? Example : Q = 21000FA^0.82 The wetted area based on HLL bigger than NLL. (The greater the wetted area the greater the heat input rate to vessel) Now, at this stage we will skip this problem this will need long explanation I will include it in another tutorial

Select : Fire API 521 To be applied only if heat flux of 21.000 BTU/hr ft^1.64 or Q = : Q = 21000FA^0.82 For fire case : Heat For Loss fire case = None : Heat Loss = None no heat loss should be assumed in fire case simulation for worst case other cases, such as *) 1. Jet fire, the heat flux is 94,500 BTU/ft2/hr. C1 = 94,500 2. For small system, the fraction area exposed by fire is 1.0 instead of 0.82 C2 = 1 3. For vessel with insulation, or covered by earth, the environment factor less than 1.0 ex = 0.3 Now, at this stage we will skip those other problem this will need long explanation I will include it in another tutorial 9 *)check in my blog for detail explanation : www.process-eng.blogspot.com Article : fire case heat input rate

10 Fill Pb = 0 For initial value, Pb =0 If the vapor flow equation is SUBSONIC, the value should be updated based on flarenet study result. # Pb has no significant effect for other vapor flow equation. See table below! Select : Musoneilan See table below!, it shows the result of sensitivity test for each vapor flow equation method. Fill Cf = 1 It is critical flow factor, generally the value close to 1.0 Ex : 0.90, 0.94 Cf = 1 for worst case of peak flow Parameter Unit Musoneilan Fisher Supersonic, (Cv in inch2) Subsonic, (Cv in inch2) Pb psig 0 25 50 0 25 50 0 25 50 0 25 50 Cv USGPM ( 60f, 1psi) 4.044 4.052 4.126 8.400 8.406 8.406 0.102 0.1019 0.102 0.102 0.1038 0.109 Peak flow lb/hr 4210 4217 4292 4190 4193 4193 4191 4204 4204 4201 4264 4423 The method selection has no significant effect to the result (peak flow) Now, you can choose one of the method with no worry about the result, personally, I prefer using MUSONEILAN In my opinion, Musoneilan is the most simple and easy to be used. DON T use SUBSONIC if the system is not in sub-critical condition The back pressure has significant effect only for SUBSONIC method

This equation show ; the back pressure has effect to the depressuring result,, Do you know,, Why the back pressure has effect only for subsonic method? *) In sub critical condition, the flowrate through control valve, nozzle, orifice, etc.,,will depends on the differential pressure between inlet and outlet. In critical condition, the flowrate through control valve, nozzle, orifice, etc.,,will only depends on the inlet pressure. MUSONEILAN Cf 0.9 0.95 1 Flow 4202.545 4205.035 4205.123 Cv 4.486085 4.252576 4.040034 SENSIVITY test result Fill Cf = 0.9-1.0 There is no worry about the result ^_^ 11 *)check in my blog : www.process-eng.blogspot.com Article : critical - subcritical

Fill PV work : 50 % for FIRE CASE PV Work Term Contribution refers to the isentropic efficiency of the process. A reversible process should have a value of 100% and an isenthalpic process should have a value of 0% UN-CHECK will result in greater peak flow rate Recommended value For gas-filled systems 80% to 100% For liquid filled systems 50% to 70% A higher isentropic efficiency results in a lower final temperature. A lower isentropic efficiency results in a higher final peak flow rate More liquid more interaction between liquid and vapor. decrease isentropic efficiency For small system inventory ( small vessel model) more friction between fluid and the vessel wall decrease isentropic efficiency 12

Depressurized from design pressure*) Set depressuring time = 15 minutes *) use Calculate Cv mode Considering of the maximum reduction of the vessel stress, vessel with thickness less than 1 inch, generally requires faster depressuring rate. Consideration of limiting flare capacity, the depressuring time longer than 15 minutes may be applied RUN after READY TO CALCULATE Fill initial value HYSYS will adjust the Cv value to achieve final pressure (e.g.100psig) at depressuring time (e.g. 15 min) The longer the depressuring time, the higher the depressuring load Set final pressure = 100 psig Or 50 % design pressure *) -100 psig for thickness less than 1 inch -and 50% DP for more 13 *)check in my blog : www.process-eng.blogspot.com Article : basic depressuring - why 15 minutes?

MAX. Cv MIN. System Temperature (during depressuring) PERFORMANCE MIN. outlet RO Temperature (during depressuring) MAX. FLOW for fire case Result in peak flow to flare = 10740 lb/hr Max Cv = 16.63 14

15

HYSYS Tool / Utilities or CTRL+U *) Select stream BASIS SIMULATION ADIABATIC Rename : Adiabatic Case 1 ST step 2 nd step Fill all of data similar with FIRE CASE except that volume of liquid based on LLL 16 3 rd step LLL mean lower liquid increase isentropic efficiency will result in lower final temperature (see page 12) Lower liquid lower flashed vapor formed from liquid phase will result in shorter depressuring time

Select : Adiabatic No heat input Select : None HYSYS does not account for any heat loss During a fire case the vessel is covered with flame. In this case, heat loss to the surrounding atmosphere determined by taking a normal atmospheric temperature is generally not correct as the vessel's surrounding temperature is very high. You should use no heat loss, select NONE for FIRE CASE NONE for ADIABATIC Can be applied if the fluid temperature is lower than the environment temperature. SIMPLE for ADIABATIC 17 Heat Loss Parameter : Use NONE for FIRE CASE Use SIMPLE for ADIABATIC except for system which is the fluid temperature lower than environment, NONE model should be applied (for lower final temperature) I suggest you to use SIMPLE heat loss model for accurate calculations. Use default values except the AMB temperature. I suggest you to use DETAILED model for accurate calculations IF ONLY you know what to do :- ) (I myself don t know how to use this option,,suusahhh cuuukkk).

See page.10 about Pb Fill CV as FIRE CASE result Cv = 16.63 see page 14 Cf = Cf in accordance with FIRE CASE Cf 0.9 1.0 18

Fill 100% for worst case For gas-filled systems 80% to 100% For liquid filled systems 50% to 70% For small system, or liquid filled system, engineering adjustment should be used. The lower efficiency shall be used for accurate calculation 19

Depressurized from operating pressure*) TRIAL depressuring time to meet final pressure 0 psig HYSYS will calculate final pressure based on depressuring time use Calculate Pressure mode In some cases, the final pressure can t meet 0 psig, (slightly above 0 psig). The system can t be decrased to lower pressure. it s OK The fact, the fluid is released to flare. The pressure of the system is correspond to the back pressure. Therefore, the final pressure is slightly above atmospheric condition 20

Required adiabatic depressuring time Min Temperature outlet RO Min Temperature In the system Adiabatic peak flow 21

22

Select File Select : # Temperature # Pressure # Mass Flow VIEW strip chart Depressuring profile VIEW result in Table Depressuring data 23

also click PERFORMANCE/ STRIP CHARTS An example : show table 24

Aspen HYSYS does not take the volume of the vessel heads into account so the volume will be the liquid in the cylindrical portion only. Aspen HYSYS defaults the volume to be equal to the volumetric flow of the feed BASIS SIMULATION. This will be disproportionate to the total volume inventory calculation where the certain margin volume is applied. Aspen HYSYS defaults the height and diameter vessel in accordance with the volume. This may be disproportionate to the actual total wetted area calculation. At present, Aspen HYSYS does not have the option for jet fire case where the heat flux is more than 21.000 BTU/hr ft^1.64. The method of spreadsheet can be used to model jet fire case. API recommends depressuring to the lower of 50% of the initial pressure or 100 psig / 6.9 barg. PV work term gas-filled systems 80% to 100% liquid filled systems 40% to 70% A higher efficiency results in a lower final temperature If one is checking that the minimum temperature of the vessel will not fall below a certain value (for example, for validating the steel alloy grade), and then 100% will give the most conservative result. 25

26