Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family



Similar documents
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Ultima X Series Gas Monitors

PortaSens ll G AS DETECTOR

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

SEC 1500 Gas Detector Instruction Manual

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

RAEGuard EC FGM-13XX

Engineering Specifications XNX Universal Transmitter

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Chlorine Gas Detection System Operation & Maintenance

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

EX-5175-EC Sensor/Transmitter Manual

Application Requirement

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D NCL-EN

Balancing chemical reaction equations (stoichiometry)

PART 1 - INTRODUCTION...

Ammonia Detection System Codes and Design Specifications

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

Lockout Specification BW Clip Maintenance-free single gas detector

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Series 510 Submersible Level Transmitters

EC-F2 Sensors. for Cl2, ClO2, CO, H2, H2S, NH3, and NO2. Instruction and Installation Manual SENSOR

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Combustible Gas Transmitter RK-05

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Series B14 Monitor System

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Draeger-Tubes and accuro Pump

Digital inductive conductivity transmitter

Technical Specifications for West Campus Data Center HVAC System

Regulator Options and Accessories

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Alphasense Application Note AAN DESIGNING A POTENTIOSTATIC CIRCUIT

The Ambient Air Monitoring System

SDX Submersible Depth Transmitter User Manual

ABSTRACT INTRODUCTION

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

ALTAIR 5X Multigas Detector Bid Specification

The Do s and Don ts of Pressure Transducers

Overview of Standards for CO Detection Products

North American Stainless

a boiling point > 65 C

Buckeye Detection Systems Fixed Detection Systems Application Survey

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

General Purpose ph/orp Sensors

Original instructions Tina 3A/Aps Adaptor unit

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

In the box below, draw the Lewis electron-dot structure for the compound formed from magnesium and oxygen. [Include any charges or partial charges.

Model: DC-A2IO Advanced HVAC Controller

Certain specific properties of compressed gases make them highly useful in various research activities.

Models SFP33 & SFP32 Pressure Transmitters

Technical Note Series

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Chapter 3 Mass Relationships in Chemical Reactions

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Installation and Instructions Manual Model 4-20IQ Sensor Transmitters

Electronic Flow Switches

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

North American Stainless

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Tina 2A/B Adaptor unit

INSTALLATION / OPERATION MANUAL

Threaded Inline Air Heaters

Sample Exercise 8.1 Magnitudes of Lattice Energies

sierra monitor corporation Fire and Gas Detection Systems

Fire Alarm System Accessories

Duct Humidity Transmitter

Operating Instructions

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

RGC-IR Remote Gas Calibrator for IR400

The photoionization detector (PID) utilizes ultraviolet

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Analytical Instruments Smart Analyzer 90 Type SMA

Problem Solving. Stoichiometry of Gases

OPERATING INSTRUCTIONS

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Battery Technology for Data Centers and Network Rooms: Ventilation of Lead-Acid Batteries

Measurement by Ion Selective Electrodes

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Operating principle and construction of zirconium dioxide oxygen sensors of the XYA series

EXPLORER 4 MULTIPOINT

G670 Intermittent Pilot Ignition Controls

Online Infrared Flue Gas Analyzer Gasboard 3000

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Toxic/Corrosive/Flammable/Pyrophoric Gas Program

Sample Exercise 2.1 Illustrating the Size of an Atom

Section 3.3: Polar Bonds and Polar Molecules

Transcription:

Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could result in instrument malfunction or serious injury. 2006 Global Detection Systems Corp. All Rights Reserved

This page intentionally left blank Global Detection Systems Corp Page 2 tech@gdscorp.com

Table of Contents SECTION 1 SAFETY INFORMATION 5 1.1 Safety Information Read Before Installation & Applying Power 5 1.2 Contacting Global Detection Systems Corp. 5 SECTION 2 EC FAMILY SENSOR SPECIFICATIONS 6 SECTION 3 - GENERAL DESCRIPTION 7 3.1 GDS Electrochemical Gas Sensor Family 7 3.2 Features (Installed in GDS-48 Remote Sensor Housing) 7 3.3 Features (Installed in GDS-49 Sensor Transmitter) 7 3.3 Features (Installed with GASMAX Gas Monitor or C2 Two-Channel Controller) 7 3.4 Electrochemical Sensor Technology 8 SECTION 4 - OPERATION 9 4.1 Installation and Startup 9 4.2 Start-Up 10 4.3 Normal Operation 10 SECTION 5 - CALIBRATION 11 5.1 Calibration 11 SECTION 6 SENSOR MAINTENANCE 12 6.1 GDS Electrochemical Sensor Maintenance 12 SECTION 7 DRAWINGS AND PARTS LIST (SIMPLE SENSOR) 13 SECTION 8 DRAWINGS AND PARTS LIST (SMART SENSOR) 14 APPENDIX A EC SENSOR TYPES & CONCENTRATIONS 15 Global Detection Systems Corp Page 3 tech@gdscorp.com

This page intentionally left blank Global Detection Systems Corp Page 4 tech@gdscorp.com

SECTION 1 SAFETY INFORMATION 1.1 Safety Information Read Before Installation & Applying Power IMPORTANT Users should have a detailed understanding of GDS Electrochemical Sensor Family operating and maintenance instructions. Use GDS EC Sensors only as specified in this manual or detection of gases and the resulting protection provided may be impaired. Read the following WARNINGS prior to use. WARNINGS Do not paint the sensor assembly. Do not use the GDS EC sensor if its enclosure is damaged or cracked or has missing components. Make sure the cover and field wiring are securely in place before operation. Periodically test for correct operation of the system s alarm events by exposing the monitor / sensor system to a targeted gas concentration above the High Alarm setpoint. Do not expose the GDS EC sensor to electrical shock or continuous severe mechanical shock. Protect the GDS EC sensor from dripping liquids and high power sprays. Use only for applications described within this manual. CAUTION: FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING OR SERVICING. ATTENTION: POUR DES RAISONS DE SÉCURITÉ, CET ÉQUIPEMENT DOIT ÊTRE UTILISÉ, ENTRETENU ET RÉPARÉ UNIQUEMENT PAR UN PERSONNEL QUALIFIÉ. ÉTUDIER LE MANUE D INSTRUCTIONS EN ENTIER AVANT D UTILISER, D ENTRETENIR OU DE RÉPARER L ÉQUIPEMENT. 1.2 Contacting Global Detection Systems Corp. To contact Global Detection Systems Corp, please call 409-927-2980, FAX 409-927-4180 or visit us on the web at www.gdscorp.com For sales information, send email to sales@gdscorp.com or for technical support email us at tech@gdscorp.com Our headquarters are located at 2513 Hwy 6 in Santa Fe, Texas 77510. Global Detection Systems Corp Page 5 tech@gdscorp.com

SECTION 2 EC FAMILY SENSOR SPECIFICATIONS Model: Global Detection Systems Corp. Electrochemical Gas Sensor Available gases: See Appendix A Detection Method: Diffusion Output (analog): Installed in GDS-48 Universal Sensor Head: Low level microvolt signal; 25 ft max cable (included) Response Time: Sensor dependent Installed in GASMAX II Gas Monitor: 4-20 ma (Source type) max. 600 Ohm load at 24 VDC supply voltage Operating Temperature Rating: Remote installation using GDS-48 Universal Sensor: -20 C to +70 C Local installation with GASMAX II Gas Monitor (Arctic Monitor option): -40 C to +70 C Operating Voltage: Installed in GDS-48 Universal Remote Sensor Head: N/A Installed in GASMAX II Gas Monitor: See GASMAX manual Power Consumption: Hazardous Environment Certification N/A Installed in GDS-48 Universal Sensor Head: CSA Certified Class 1, Division 1, Groups B, C, D Installed in GASMAX II Gas Monitor: CSA Certified Class 1, Division 1 Groups B, C, D Warranty: Electronics Two years from date of purchase Sensor One year from date of purchase Global Detection Systems Corp Page 6 tech@gdscorp.com

SECTION 3 - GENERAL DESCRIPTION 3.1 GDS Electrochemical Gas Sensor Family The GDS family of Electrochemical (EC) Sensors provides a low cost, efficient solution for the monitoring of toxic gases. Sensors are available in a wide range of gases and concentrations, with an emphasis on detection of levels recommended for personnel protection. GDS EC Sensors can be directly connected to a GDS Corp C2 Protector two-channel controller, a single or dual channel GASMAX II Gas Monitor, a GDS-49 Sensor Transmitter or other instrumentation device that supports a low level microvolt input. To connect GDS EC Sensors to a GDS C1 Protector sixteen-channel controller, the GDS-49 Sensor Transmitter is recommended. 3.2 Features (Installed in GDS-48 Remote Sensor Housing) Output compatible with C2, GASMAX and GDS-49 low-level microvolt input circuits Wide selection of gases and target ranges available Low cost 3.3 Features (Installed in GDS-49 Sensor Transmitter) All above features plus the following: 4-20mA two-wire current sink output Sensor fault / sensor removed indication 3.3 Features (Installed with GASMAX Monitor or C2 Controller) All above features plus the following: Smart Sensor records serial number, born-on date and other information (GASMAX only) Graphic alphanumeric display in engineering units with alarm LEDs Optional isolated 4-20mA output, MODBUS digital serial output Optional alarm relay contacts (3 separate levels + Fault) Magnetic interface allows setup without declassifying hazardous area Second GASMAX channel supports simultaneous monitoring of toxic gas using electrochemical sensor Global Detection Systems Corp Page 7 tech@gdscorp.com

3.4 Electrochemical Sensor Technology Electrochemical sensors operate by reacting with the gas of interest and producing an electrical signal proportional to the gas concentration. A typical electrochemical sensor consists of a sensing electrode, a reference electrode and a counter electrode. Gas molecules in the ambient air diffuse through the sensor hydrophobic membrane and react with the electrolyte material. Depending on the type of sensor and target gas, the gas is either oxidized or reduced at the surface of the electrolyte, creating a micro-amp current flow between the sensor electrodes. Some electrochemical sensors require a bias voltage to maintain a known chemical environment in the cell electrolyte. If the bias voltage is removed (during storage, for example), it may take several hours or even days for the sensor to re-stabilize once the bias voltage is applied. In some cases, a filter is installed in front of the hydrophobic membrane to filter out unwanted gases that may be present in some applications. The most commonly used filter is activated charcoal; this filters out most gases with the exception of carbon monoxide and hydrogen. As a result of each sensor s unique design requirements, electrochemical sensors are generally selective to the intended target gas. In some cases, electrochemical sensors will react with compounds similar to the target gas (chlorine sensors will detect bromine, for example). This effect is called cross sensitivity and as a result the user should be aware of all gases that might be present in a specific application. Due to the chemical reactions present in electrochemical sensors, a continuous supply of oxygen is required for most sensors to operate. An inadequate supply of oxygen will reduce overall sensitivity and eventually cause the sensor to fail. The life expectancy of an electrochemical sensor is determined by the amount of gas seen by the sensor, relative humidity, temperature and the presence of certain reactive gases. As the sensor ages, the electrolyte is eventually used up and the sensor must be replaced. Prolonged exposure to extremely high humidity applications can cause the sensor electrolyte to become overly saturated with water, causing physical swelling and leakage. Extremely low humidity will cause the sensor electrolyte to dry out prematurely. Global Detection Systems Corp Page 8 tech@gdscorp.com

SECTION 4 - OPERATION 4.1 Installation and Startup WARNING: THE USER SHALL BE MADE AWARE THAT IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. The first step in the installation process is to establish a mounting location for the GDS EC sensor. Select a location that is typical of the atmosphere to be monitored or close to the anticipated source of a target gas. It is very important that the GDS EC sensor be properly located to enable it to provide maximum protection. The most effective number and placement of sensors vary depending on the conditions of the application. When determining where to locate sensors the following factors should be considered. What are the characteristics of the gas that is to be detected? Is it lighter or heavier than air? If it is lighter than air the sensor should be placed above the potential gas leak. Place the sensor close to the floor for gases that are heavier than air or for vapors resulting from flammable liquid spills. Note that air currents can cause a gas that is heavier than air to rise. In addition, if the temperature of the gas is hotter than ambient air or mixed with gases that are lighter than air, it could also rise. How rapidly will the gas diffuse into the ambient air? Select a location for the sensor that is close to the anticipated source of a gas leak. Wind or ventilation characteristics of the immediate area must also be considered. Movement of air may cause gas to accumulate more heavily in one area than in another. The detector should be placed in the areas where the most concentrated accumulation of gas is anticipated. For outdoor applications with strong wind conditions, it may require the sensors to be mounted closer together and on the down wind side, to the anticipated area of a gas leak. Also take into consideration for indoor applications, the fact that many ventilation systems do not operate continuously. The sensor should be accessible for maintenance. Global Detection Systems Corp Page 9 tech@gdscorp.com

Excessive heat or vibration can cause premature failure of any electronic device and should be avoided if possible. Follow all national and local installation codes and practices. The GDS-48 Universal Sensor housing, GASMAX II Gas Monitor and GDS-49 Sensor Transmitter provide a ¾ NPT threaded connector for installation with conduit or shielded cable. For C2 Controller or GASMAX monitor remotely-mounted sensors, special twisted wire is provided and must be used (max length 25 ). Wiring should be installed in metal conduit with no other cabling in the same conduit. 4.2 Start-Up After installation, allow the sensor to stabilize for a minimum of eight hours (overnight is best). 4.3 Normal Operation The operation of any gas sensor should be checked periodically to ensure proper operation. When first installed, a GDS EC Sensor should be challenged with a calibration gas to make certain that the detector and any associated alarm systems are functional. Periodically thereafter, the sensor should be tested and/or recalibrated as necessary. Normally, initial calibration tests should be done at least monthly, and may be done on a more extended basis once some experience with the sensor and surrounding environment is obtained. Global Detection Systems Corp Page 10 tech@gdscorp.com

SECTION 5 - CALIBRATION 5.1 Calibration GDS EC Sensors are available factory-programmed for specific gases and ranges. Each sensor should be calibrated for best accuracy as described in the appropriate controller manual using clean ambient air (or zero air if toxic gases are present) for zero calibration and the appropriate reference gas for span calibration. After installation, allow the sensor to stabilize for a period of 8 hours or more, preferably overnight, before performing the initial calibration. During the first several weeks of operation, periodically calibrate the sensor to ensure there are no localized sources of contamination or environmental effects that may block cause the unit to drift or become inaccurate. It is recommended that the eventual period between calibrations be no longer than 60 days. Global Detection Systems Corp Page 11 tech@gdscorp.com

SECTION 6 SENSOR MAINTENANCE 6.1 GDS Electrochemical Sensor Maintenance The GDS Electrochemical Sensor is a highly reliable, self-contained detector that requires very little maintenance other than periodic calibration and/or sensor element replacement. There are no user-serviceable parts inside the sensor element. Global Detection Systems Corp Page 12 tech@gdscorp.com

SECTION 7 DRAWINGS AND PARTS LIST (Simple Sensor) Green (Earth Ground) Red (Ref) White (Signal) Black (Active) +2.0 V Out 0 V P/N 10-0194 Stainless Steel Sensor Head 3/4 NPT Male Thread Sensor Head Body Sensor O-Ring Electrochemical Sensor Sensor Head Cover P/N 10-80xx Electrochemical Simple Sensor GDS Electrochemical Simple Sensor Assembly Part No. Description 10-0194 Stainless Steel Sensor Head 10-80xx GDS electrochemical simple sensor 10-0198 Sensor splash guard 10-0205 Sensor flow cell for process monitoring 10-0187 Sensor replacement tool kit 1000-0078 Large black magnet for GASMAX II Global Detection Systems Corp Page 13 tech@gdscorp.com

SECTION 8 DRAWINGS AND PARTS LIST (Smart Sensor) Green (Earth Ground) P/N 10-0247 Stainless Steel Sensor Head Sensor connector to GDS-48 Remote Sensor Assembly or GASMAX II Gas Monitor 3/4 NPT Male Thread Sensor Head Body Electrochemical Sensor Sensor Head Cover P/N 10-90xx Electrochemical Smart Sensor GDS Electrochemical Smart Sensor Assembly Part No. Description 10-0247 Stainless Steel Sensor Head 10-90xx GDS electrochemical smart sensor 10-0198 Sensor splash guard 10-0205 Sensor flow cell for process monitoring 10-0187 Sensor replacement tool kit 1000-0078 Large black magnet for GASMAX II Global Detection Systems Corp Page 14 tech@gdscorp.com

APPENDIX A EC SENSOR TYPES & CONCENTRATIONS Gas / Vapor Formula Range GDS Sensor Type Ammonia NH 3 0-100 ppm 20 Arsine AsH 3 0-1 ppm 23 Bromine Br 12 Carbon Disulfide CS 2 22 Carbon Monoxide CO 0-1 ppm 11 Chlorine CL 2 0-5 ppm 12 Chlorine CL 2 0-50 ppm 12 Chlorine Dioxide CLO 2 0-1 ppm 13 Diborane B 2 H 6 23 Ethylene Oxide C 2 H 4 O 0-20 ppm 22 Fluorine F 2 0-1 ppm 25 Hydrazine N 2 H 4 0-1 ppm 27 Hydrogen H 2 0-2000 ppm 14 Hydrogen Chloride HCL 0-30 ppm 17 Hydrogen Cyanide HCN 0-50 ppm 16 Hydrogen Fluoride HF 0-10 ppm 18 Hydrogen Sulfide H 2 S 0-50 ppm 15 Hydrogen Sulfide H 2 S 0-100 ppm 15 Nitric Oxide NO 0-100 ppm 28 Nitric Oxide NO 0-500 ppm 28 Nitrogen Dioxide NO 2 0-5 ppm 29 Nitrogen Dioxide NO 2 0-50 ppm 29 Mercaptan CH 4 S 0-50 ppm 30 Oxygen O 2 0-25% 10 Ozone O 3 0-1 ppm 21 Phosphorus Trichloride PCL 3 17 Phosgene COCL 2 0-1 ppm 26 Silane SiH 4 0-50 ppm 24 Sulfur Dioxide SO 2 0-20 ppm 19 Sulfur Dioxide SO 2 0-100 ppm 19 Tetrahydrothiophene THT C 4 H 8 S 0-100 ppm 31 Notes Global Detection Systems Corp Page 15 tech@gdscorp.com