Toxic/Corrosive/Flammable/Pyrophoric Gas Program
|
|
|
- Ann Allison
- 9 years ago
- Views:
Transcription
1 ///Pyrophoric Gas Program I. Policy A broad spectrum of toxic, corrosive and pyrophoric compressed gases is used at the California State University Fullerton (CSUF) campus. Increased recognition of the hazards associated with the transportation, operation, and storage of these gases has prompted a higher level of governmental regulation regarding these activities in all work settings. Because of the extreme health hazard presented by an accidental release of a highly toxic gas on the CSUF campus, the Environmental Health & Safety Department has developed a Gas Program designed to minimize the hazards associated with toxic and corrosive gases. The purpose of this program is to minimize the likelihood of an uncontrolled toxic gas release by establishing minimum standards and uniform procedures for purchasing, handling, use, storage, and disposal of these gases at UC Berkeley facilities. II. Authority California Code of Regulations (CCR), Title 8, Section 4650 California Code of Regulations (CCR) Title et al California Code of Regulations, Title 19, Section 3.18 California Code of Regulations, Title 24, Part 9, Chapter 74, Section 7404, 8003 NFPA 45, Chapter 8 NFPA 99, Chapter 4 NFPA 704, Chapter 2 III. Scope This program applies to the purchase, transportation, use, storage, and disposal of toxic gases (as defined in this document) by faculty, staff, and students of UC Berkeley. Definitions are provided in Appendix A. This Program applies to all CSUF instructional and research including leased properties. The Program covers all unfired pressure vessels (i.e. storage tanks, compressed gas cylinders) that have been designed to operate at pressures above 15 psig, including the storage and use of compressed gas cylinders and cryogenic fluids. This Program does not address USE of the gases, but addresses industry/institutional accepted standard safe work practices. Certain dilute toxic gases are exempt from this program if worst case release modeling of an accidental acute release indicates that the gas concentration will not result in exposures to laboratory personnel exceeding any of the following: The Cal/OSHA Short Term Exposure Limit (STEL) The Threshold Limit Value-ceiling (TLV-C)
2 One half of the concentration established as Immediately Dangerous to Life or Health (IDLH) as defined in the California Code of Regulations, Title 8, Section 5192 IV. Definitions Ceiling: The chemical concentration about the breathing zone that must not be exceeded at any time for a working exposure. DOT: The United States Department of Transportation. DOT is responsible for promulgating regulations controlling the transport of toxic gases. IDLH: Immediately Dangerous to Life or Health. "An atmospheric concentration of any toxic, corrosive, or asphyxiant substance that poses an immediate threat to life or would cause irreversible or delayed adverse health effects or would interfere with an individual's ability to escape from a dangerous atmosphere" (California Code of Regulations, Title 8, Section 5192). Manometer: An instrument for measuring pressure. A U-tube partially filled with a liquid that indicates the pressure exerted on the instrument by displacement of the liquid. Leak Test: Testing pressurized apparatus by a reliable method. This may include coating all non-welded joints with a soap solution which is capable of forming bubbles at leak points, a pneumatic leakdown test using accurate gauges, or other effective measures. Magnehelic: A diaphragm-type pressure differential sensor with a direct reading gauge. NFPA: National Fire Protection Association. PEL: Permissible Exposure Limit: The maximum concentration of an airborne contaminant to which a worker may be exposed for an 8-hour shift. PELs are established and enforced by Cal/OSHA (California Occupational Safety and Health Administration). RMPP: Risk Management and Prevention Program. A Risk Management Prevention Program is required to anticipate and prevent circumstances that could result in accidental releases of acutely hazardous materials (AHMs) if used in amounts greater than the threshold planning quantity (TPQ). The RMPP includes a hazard and operability study, offsite consequence analysis, and seismic analysis. RFO: Restricted Flow Orifice. An in-cylinder device that reduces the maximum gas release rate. 2
3 STEL: Short Term Exposure Limit. A maximum time weighted exposure that should not be exceeded for any 15-minute period during a workday. TLV-TWA: The threshold limit value time weighted average concentration for a normal 8-hour workday or 40-hour workweek, to which nearly all workers may be repeatedly exposed, day after day, without adverse effect. Gas: gases, for the purpose of this program, are gases that may cause significant acute health effects at low concentrations. Health effects may include severe skin or eye irritation, pulmonary edema, neurotoxicity, or other potentially fatal conditions. The criteria used to establish the list for this policy (see Appendix A) are: (1) A National Fire Protection Association (NFPA) health rating of 3 or 4; (2) An NFPA health rating of 2 with poor physiological warning properties; (3) Pyrophoric (self igniting) characteristics or; (4) Extremely low occupational exposure limits in the absence of an NFPA health V. Accountability Establish and implement a program to identify toxic/corrosive/flammable/pyrophoric gases utilized in research at CSUF and provide a mechanism to safely transport, store, and use of toxic/corrosive/flammable/pyrophoric gases. Environmental Health and Safety Department The Environmental Health and Safety Department (EH&S) provides the Principle Investigator, Academic Laboratory Leader assistance in establishing appropriate safety procedures and safety equipment for the safe use of toxic/corrosive/flammable/pyrophoric gases. EHI&S will provide training upon request as well as provide consultation on regulatory compliance. EHI&S will provide reviews of equipment setup and gas handling procedures. EHI&S will notify the PI if the gas type and amount may necessitate a Risk Management and Prevention Plan. EHI&S will assist the PI in developing a RMPP and act as a liaison with applicable regulatory agencies. EH&S maintain an active ///Pyrophoric Gas Program and will perform semiannual inspections of all laboratory spaces to verify compliance with this manual, and provide the results to the appropriate college Dean(s). Chemical Hygiene Officer The Chemical Hygiene Officer (CHO) shall keep an inventory gases ( / corrosive / flammable / pyrophoric /cryogenic) utilized in research at CSUF. The CHO will inspect each laboratory semiannually and perform random Spot-Inspections in all laboratories. The CHO will inspect the cylinder storage, gas regulators and to a limited aspect the connection(s) to 3
4 the experiment in order to provide recommendations to the safe storage and management of the gases. Dean, College of Natural Science and Mathematics College Deans The College Dean is responsible for providing the space, equipment, and funding necessary for safe laboratory operation. Department Chairs Department Chairs are responsible for supporting the established Campus policies, procedures, guidelines and standard operating procedures in order to provide an effective laboratory safety in their Departments. Principal Investigator / Academic Laboratory Leader The Principal Investigator (PI) or Academic Laboratory Leader (ALL, the Faculty or Graduate Student/Teaching Assistant member in charge of an academic laboratory section) is responsible for ensuring all laboratory activities under their control meet or exceed applicable industry/institutional standards and all applicable State and Federal regulations and local ordinances, and present a minimal level of risk to laboratory participants. The PI or ALL/TA is responsible for identification of hazards and the assessment of all risks associated with laboratory operations. The PI or ALL/TA is responsible for toxic/corrosive/flammable/pyrophoric gas safety in the laboratory. The PI or ALL/TA shall provide and document safety instruction to ensure that staff and/or students are aware of hazards involved with their laboratory tasks, and the equipment and practices required to safely perform their assigned tasks. The PI or ALL/TA shall ensure necessary safety equipment is available in the laboratory, used when required, and adequately maintained. The PI or ALL/TA shall establish and annually review emergency procedures. The PI or ALL shall arrange for immediate medical attention for injured personnel and report incidents of injury or property damage as required. Laboratory Staff/Student It is the responsibility of each person working in a laboratory to be aware of the risks associated with their assigned duties, and to comply with the procedures provided. Report any unsafe conditions or practices to the PI, ALL, or to EH&S by calling (x. 7233). Report all incidents resulting in injury, property damage, or exposure to a hazardous agent to the EH&S by calling (x. 7233) and your PI or ALL. Environmental Health and Safety Department The Environmental Health and Safety Department (EH&S) provides consulting, training, and compliance verification support for laboratory matters relating to regulatory and policy compliance, safety, risk, and health in the laboratory. EH&S will perform semiannual and Spot inspections of all laboratory spaces to verify compliance with this and other policies, procedures, guidelines, and standard operating procedures and provide the results to the appropriate Department Chair(s) and college Dean(s). VI. Program 4
5 Upon receipt of toxic/corrosive/flammable/pyrophoric gases cylinders, the cylinders shall be temporarily stored in a well-ventilated area that is locked at all times. All cylinders shall be immediately leak tested with a leak indicating solution and must be clearly labeled with content and hazard information. Temporary storage locations shall have appropriate signage in place. Cylinders must be seismically secured at all locations with chains at two contact points on the cylinder body, using unistruts or an equivalent. Seismic securing should prevent cylinders from rolling, shifting, or falling. Storage & Security Laboratory storage of all toxic gas cylinders shall be in a mechanically ventilated, lockable area. Examples of mechanical ventilation include vented gas cabinets and fume hoods (lecture bottle size (F) to D size bottles only). Rooms containing toxic gases shall be locked when not occupied by authorized persons. All cylinders and gas cabinets must be clearly labeled with content and hazard information. Cylinders shall be seismically secured at all locations with chains (2 contact points), using unistruts or an equivalent for cylinders larger than lecture bottles. Lecture bottles must be secured to a stable surface. Outdoor storage is only allowed on a short term basis in a secure, lockable area at least 75 feet from an exterior door, window, or air intake location. Transport from Off-campus Supplier All commercial vendors and university employees shall comply with DOT regulations, where applicable, regarding the transport of toxic gases. Questions regarding the transportation of toxic gases should be directed to EH&S (x. 7233). On-campus Transport Transport of ALL toxic gases between on-campus locations must be conducted as follows: Gas cylinders must be secured to the transport vehicle (cart, motor vehicle, hand truck, etc.) Cylinders must be continuously attended during transport Cylinders must be clearly labeled with content and hazard information Cylinder caps must be in place These requirements apply to all listed toxic gas containers, including empty and partially full cylinders. Common Gases as Defined by the Gas Ordinance and California Fire Code Gas Regulators and Lines All regulators, valves, and lines must be chemically compatible with the gases being used. Compatibility can be determined by contacting the gas vendor or by calling EH&S (x. 7233). Regulator/line systems must be leak tested immediately after assembly and before each use. Regulators shall be compatible with the size and type of gas cylinder being used, and rated for full cylinder pressure. Cylinder and Reaction Vessel/Chamber Enclosure All toxic gas cylinders and reaction vessels/chambers shall be kept in ventilated enclosures during use and storage. Air-flow velocities at all openings in the vented enclosures must be 0.5 m/s (100 fpm) or greater while in the open position. Where regular access is needed, small access doors must be used to minimize exhaust flow reduction. 5
6 Purge Vents and Exhaust Lines All lines or ducts carrying purged or exhausted emissions of toxic/ corrosive/flammable/ pyrophoric gases must be connected to a mechanical exhaust system that discharges to a safe location (i.e., presents no potential for re-entrainment into any building supply air intake or occupied area). Exhaust duct walls shall be chemically resistant to degradation by the toxic gas in use. Significant emissions of corrosive or toxic gases require an emission control device (e.g., scrubber, flare device, adsorbent) before the purged gas can be vented into the exhaust duct system. Significant emissions are defined as duct concentrations that result in duct corrosion or acute health risk to persons exposed near exhaust fan stacks as determined by release modeling. When toxic gases are emitted from exhaust systems at concentrations which could pose health risks to rooftop workers, locked gates, doors, or other means shall be used to prevent worker access to stack discharge areas. Warning signs must be conspicuously placed. Ventilation Monitoring A ventilation monitor is required on each lab hood or gas cabinet in which toxic/corrosive/ flammable/pyrophoric gases are used and stored. Acceptable monitors include audible and visual alarms, in conjunction with magnehelic gauge, inclined manometer, or other devices which indicate that the enclosure is actively ventilated. Manometers and gauges should be clearly marked to indicate safe pressure limits. Empty Cylinder Disposal All empty toxic/ corrosive/flammable/pyrophoric gases gas cylinders shall be labeled as empty. Depleted toxic gas cylinders should be returnable to the vendor according to their guidelines. The purchase of any gases that will not be completely used in the course of research must be approved by the vendor for return, or by EH&S for disposal as hazardous waste. Disposal of toxic gas cylinders by EH&S, even when empty, may entail extraordinary costs. Therefore, toxic gases should be purchased only from vendors who will accept returns. Gas Monitors Electronic toxic/ corrosive/flammable/pyrophoric gas monitors with alarms should be installed and continuously operated wherever a toxic gas is used which has a high concentration, large quantity, and/or poor physiological warning properties (odor or irritation). The requirement for a monitoring system will be decided on a case by case basis and will be required more commonly for continuous operations and long term research situations. A toxic gas has poor warning properties when such properties are only noticeable at or above harmful concentrations (e.g., the PEL). Some toxic gases with poor warning properties are identified in the list of common toxic gases. Gas monitoring equipment must be able to detect concentrations at or below the PEL. Alarm Locations All gas monitoring systems should have: Audible and visible alarms in the following locations: gas supply location, gas use or operator room, and outside the gas use room (e.g., corridor) 6
7 An alarm status and gas concentration readout panel located outside the gas use room Local audible and visual alarms specific and distinct from fire alarm bells and signs to indicate the alarm's meaning and required personnel action The toxic gas alarm level setpoint set at the PEL or Threshold Limit Value Power and Control gas monitors and alarms should be connected to an emergency power source. In the event of a power failure, the detection system should continue to operate without interruption, or gas systems should automatically shut down at the source. Power connections, control switches, and adjustments that affect the detection system operation should be protected from direct access by locks on the enclosures. Updated 9/14/11 tw 7
8 COMMON TOXIC GASES AS DEFINED BY THE TOXIC GAS ORDINANCE AND CFC For Use By All Jurisdictions, Cities and County, Within the Limits of Santa Clara County. Authority Cited: California Fire Code (CFC); California Building Code (CBC); Gas Ordinance (TGO) GAS & FORMULA CAS No./ UN No. CBC/CFC CLASS 1 TGO CLASS 2 IDLH 3 LC 50 4 LOC MAX TQ PEL 5 Ammonia - NH UN1005 Arsine - AsH UN2188 Boron Tribromide - BBr UN2692 Boron Trichloride - BCl UN1741 Boron Trifluoride - BF UN1008 6,7 WR-2 6 WR-1 WR-1 III 300 ppm 4,000 ppm 30 ppm 8,000 lbs. 50 ppm I 3 ppm 20 ppm 0.3 ppm N/A 0.05 ppm II 50 ppm 380 ppm 5 ppm 760 lbs. 1 ppm II 25 ppm 8 2,541 ppm 2.5 ppm 5,082 lbs. 5 ppm II 25 ppm 806 ppm 2.5 ppm 1,612 lbs. 1 ppm Bromine - Br UN1744 Oxidizer I 3 ppm 113 ppm 0.3 ppm N/A 0.1 ppm Carbon Monoxide - CO UN III 1,200 ppm 3,760 ppm 120 ppm 7,520 lbs. 50 ppm Chlorine - Cl UN1017 Oxidizer II 10 ppm 293 ppm 1 ppm 586 lbs. 1 ppm Chlorine Dioxide - ClO NA9191 Chlorine Trifluoride - ClF UN1749 Diborane - B 2 H UN1911 UR-3 Oxidizer WR-1 Oxidizer WR-3 WR-2 II 5 ppm 250 ppm 0.5 ppm 500 lbs. 0.1 ppm II 20 ppm 299 ppm 2 ppm 598 lbs. 0.1 ppm I 15 ppm 80 ppm 1.5 ppm N/A 0.1 ppm UN-015-1/4 Rev. 02/11/08
9 Common Gases as Defined by the Gas Ordinance and CFC Page 2 of 4 GAS & FORMULA CAS No./ UN No. CBC/CFC CLASS 1 TGO CLASS 2 IDLH 3 LC 50 4 LOC MAX TQ PEL 5 Dichlorosilane - SiH 2 Cl 2 (HCl) UN2189 II 50 ppm 314 ppm 5 ppm 628 lbs. 5 ppm Ethylene Oxide - C 2 H 4 O UN1040 Fluorine - F UN1045 Germane - GeH UN UR-3 Oxidizer UR-3 III 800 ppm 4,350 ppm 80 ppm 8,700 lbs. 1 ppm I 25 ppm 185 ppm 2.5 ppm N/A 0.1 ppm II 6 ppm ppm 0.6 ppm 1,244 lbs. 0.2 ppm 9 Hydrogen Bromide - HBr UN1048 Hydrogen Chloride - HCl UN II 30 ppm 2,860 ppm 3 ppm 5,720 lbs. 3 ppm 6 II 50 ppm 2,810 ppm 5 ppm 5,620 lbs. 5 ppm Hydrogen Cyanide - HCN UN1051 I 50 ppm 40 ppm 5 ppm N/A 10 ppm Hydrogen Fluoride - HF UN1052 II 30 ppm 1,300 ppm 3 ppm 2,600 lbs. 3 ppm Hydrogen Selenide - H 2 Se UN2202 Hydrogen Sulfide - H 2 S UN1053 I 1 ppm 2 ppm 0.1 ppm N/A 0.05 ppm II 100 ppm 712 ppm 10 ppm 1,424 lbs. 20 ppm Methyl Bromide - CH 3 Br UN1062 II 250 ppm 1,007 ppm 25 ppm 2,014 lbs. 20 ppm Methylisocyanate - CH 3 NCO UN2480 WR-2 I 3 ppm 22 ppm 0.3 ppm N/A 0.02 ppm UN-015-2/4 Rev. 02/11/08
10 Common Gases as Defined by the Gas Ordinance and CFC Page 3 of 4 GAS & FORMULA CAS No./ UN No. CBC/CFC CLASS 1 TGO CLASS 2 IDLH 3 LC 50 4 LOC MAX TQ PEL 5 Methyl Mercaptan - CH 3 SH UN1064 II 150 ppm 1,350 ppm 15 ppm 2,700 lbs. 10 ppm Nickel Carbonyl - Ni(CO) UN1259 UR-3 WR-1 I 2 ppm 18 ppm 0.2 ppm N/A ppm Nitric Oxide - NO UN1660 Nitrogen Dioxide - NO UN1067 Phosgene - COCl UN1076 Phosphine - PH UN2199 Phosphorus Oxychloride - POCl UN1810 Phosphorus Pentafluoride - PF UN2198 Phosphorus Trichloride - PCl UN1809 Oxidizer Oxidizer WR-1 WR-1 Pyrophoric WR-2 Oxidizer WR-1 UR-2 WR-2 Oxidizer I 100 ppm 115 ppm 10 ppm N/A 25 ppm I 20 ppm 115 ppm 2 ppm N/A 5 ppm I 2 ppm 5 ppm 0.2 ppm N/A 0.1 ppm I 50 ppm 20 ppm 5 ppm N/A 0.3 ppm I 0.96 ppm 8 96 ppm ppm N/A 0.1 ppm 8,9 II 2.6 ppm ppm 0.26 ppm 520 lbs. 3 ppm II 25 ppm 208 ppm 2.5 ppm 416 lbs. 0.5 ppm Selenium Hexafluoride - SeF UN2194 I 2 ppm 50 ppm 0.2 ppm N/A 0.05 ppm (as Se) Silicon Tetrachloride - SiCl 4 (HCl) UN1818 Silicon Tetrafluoride - SiF 4 (HF) UN1859 WR-2 II 50 ppm 750 ppm 5 ppm 1,500 lbs. 5 ppm II 30 ppm 450 ppm 3 ppm 900 lbs. 0.1 ppm UN-015-3/4 Rev. 02/11/08
11 Common Gases as Defined by the Gas Ordinance and CFC Page 4 of 4 GAS & FORMULA CAS No./ UN No. CBC/CFC CLASS 1 TGO CLASS 2 IDLH 3 LC 50 4 LOC MAX TQ PEL 5 Stibine - SbH UN2676 I 5 ppm 20 ppm 0.5 ppm N/A 0.1 ppm Sulfur Dioxide - SO UN1079 Sulfuryl Fluoride - SO 2 F UN II 100 ppm 2,520 ppm 10 ppm 5,040 lbs. 5 ppm 6 III 200 ppm 3,020 ppm 20 ppm 6,040 lbs. 5 ppm Tellurium Hexafluoride - TeF UN2195 I 1 ppm 25 ppm 0.1 ppm N/A 0.02 ppm (as Te) Titanium Tetrachloride - TiCl UN1838 WR-2 I 1.3 ppm 119 ppm 0.13 ppm N/A Tungsten Hexafluoride - WF 6 (HF) UN2196 WR-2 II 30 ppm 217 ppm 3 ppm 434 lbs. 0.1 ppm Notes: 1 Class as defined in CFC: 1.) Health Hazards per Chapter 27: = < 200 LC 50, = 200-2,000 LC ) Physical Hazards per CFC Chapter 27 and NFPA TGO Class Defined As: Class I = < 200 LC 50, Class II = 200 3,000 LC 50, Class III = 3,001 5,000 LC 50 3 IDLH values published in 1994 by the National Institute for Occupational Safety and Health (NIOSH). 4 LC 50 data: Lowest reported value, 1 hour adjusted, taken from DOT, CGA, RTECS. 5 PEL values published by OSHA (29 CFR, part , Table Z-1) dated 7/1/95. OSHA values used if available, otherwise Threshold Limit Value (TLV) from American Conference of Governmental Industrial Hygienists (ACGIH) ( ) or Cal OSHA values used. = Ceiling Limit. 6 Moderately toxic as adopted by the cities of San Jose, Santa Clara, and Milpitas: LC50 = 2,000 5, When used as a refrigerant, CBC Class does not apply. See TGO consensus guidelines for additional information regarding ammonia refrigeration systems. 8 IDLH determined by 0.01 of LC Cal OSHA PEL, Title 8, Section 5155, 9/1/95. UN-015-4/4 Rev. 02/11/08
Certain specific properties of compressed gases make them highly useful in various research activities.
GAS CYLINDER SAFETY Introduction Certain specific properties of compressed gases make them highly useful in various research activities. These gases, however, can be dangerous if not handled in an appropriate
COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
UCLA - Compressed Gas Cylinder Storage and Handling
UCLA - Compressed Gas Cylinder Storage and Handling Purpose UCLA is committed to provide safety guidelines concerning the handling and use of portable compressed gas cylinders. Compressed gases represent
Toxic Inhalation Hazard (TIH) Commodity List (AAR 2.3, 6.1, and Anhydrous Ammonia) Carloads, 2003 Waybill Sample
Toxic Inhalation Hazard (TIH) Commodity List (AAR 2.3, 6.1, and Anhydrous Ammonia) Carloads, 2003 Waybill Sample Commodity HazMat STCC Commercial STCC WASTE ALLYL ALCOHOL 4821019 WASTE TOXIC LIQUID, CORROSIVE,
Compressed Gas Cylinder Safety
Compressed Gas Cylinder Safety I. Background. Due to the nature of gas cylinders, special storage and handling precautions are necessary. The hazards associated with compressed gases include oxygen displacement,
Methane in Air 0.0001% to 2.5%
Kele part# GAS-CH4-2.5 Emergency Contact: Chemtrec (800) 424-9300 Or rco (208) 336-1643 1125 West Amity Road Boise, ID 83705 (208) 336-1643 Methane in Air 0.0001% to 2.5% M A T E R I A L S A F E T Y D
Compressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Fume Hood Questions and Answers
Fume Hood Questions and Answers 1. When should I use a fume hood? Use a chemical fume hood anytime your work involves: Chemicals with a National Fire Protection Association (NFPA) Health rating of 3 or
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
COMPRESSED GAS CYLINDER PROGRAM
COMPRESSED GAS CYLINDER PROGRAM Department of Environmental Health & Safety Phone: (410) 704-2949 Fax: (410) 704-2993 Emergency: (410) 704-4444 Email: [email protected] Website: www.towson.edu/ehs/index/html
Mechanical Systems Competency 1.20
Competency 1.20 Mechanical systems personnel shall demonstrate a working level knowledge of the safety and health fundamentals of mechanical systems and/or components. 1. Supporting Knowledge and Skills
Hazard Warning Signage Guidelines
Fire Department 401 Oak Street, #402 Roseville, California 95678-2649 Hazard Warning Signage Guidelines Where hazardous materials are stored in quantities that require a permit pursuant to CFC Table 105.6.20,
* * * EMERGENCY OVERVIEW * * * High pressure gas. Can cause rapid suffocation. Can increase respiration and heart rate.
SUPPLIER ADDRESS: PRODUCT NAME: Saxon Wharf, Lower York St Southampton SO14 5QF, UK 1. CHEMICAL PRODUCT EMERGENCY PHONE NUMBER: COMPRESSED GAS, N.O.S. SYNONYMS: None (Contains: CARBON DIOXIDE & NITROGEN)
Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)
Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP) Formaldehyde, formalin, paraformaldehyde solutions, and paraformaldehyde solids Principal Investigator: Room & Building #: Department:
North Carolina State University Emergency Facilities Closure Checklist- Part I
North Carolina State University Emergency Facilities Closure Checklist- Part I Unplanned or spontaneous events often disrupt daily operations on campus. In the event that an incident may interrupt your
SAFETY AND HEALTH PROGRAM
PROGRAM NUMBER NO. PAGES 05-005 10 REVISION ISSUE DATE Revision 2 11/1/2005 SAFETY AND HEALTH PROGRAM Confined Space Entry 1.0 INTRODUCTION Confined Space Entry is a serious workplace hazard, capable of
Material Safety Data Sheet
Material Safety Data Sheet Section 1 General Information Manufacturer: Zinsser Company, Inc. 173 Belmont Drive Somerset, NJ 08875 (732) 469-8100 Emergency Telephone: Chemtrec (800) 424-9300 Date: December
EOSMS 204C Effective Date: 12/8/2014 Page 1 of 8
EOSMS 204C Effective Date: 12/8/2014 Page 1 of 8 1. Purpose This Standard Operating Procedure (SOP) establishes procedures for the safe handling, transportation and storage of (MC), which is also known
Requirements for Hydrogen Storage and Use
Requirements for Hydrogen Storage and Use I. INTRODUCTION Fire and Life-Safety Group (FLS) The following is a summary of the fire and building code requirements for the storage and use of hydrogen. These
Material Safety Data Sheet
Material Safety Data Sheet OASIS PRO 10 HEAVY DUTY ALL PURPOSE 1. Product and company identification Trade name of product Product use Product dilution information : OASIS PRO 10 HEAVY DUTY ALL PURPOSE
University of Tennessee Safety Guidelines
University of Tennessee Safety Guidelines Guideline Subject: Compressed Gases and Cryogenics Safety Guidelines Approval Date: 10/1/15 (Rev. 1) Next Scheduled Review: 10/1/19 Date Effective: 1/01/09 Contact
Material Safety Data Sheet
Material Safety Data Sheet OASIS 259 GLASS FORCE 1. Product and company identification Trade name of product Product use Product dilution information : OASIS 259 GLASS FORCE : Glass Cleaner : Up to 12.5
MATERIAL SAFETY DATA SHEET
SECTION 1 GENERAL INFORMATION Manufacturer: HMIS Rating Modern Masters, Inc. HEALTH 1 9380 San Fernando Road FLAMMABILITY 0 Sun Valley, CA 91352 REACTIVITY 0 818-683-0201 Emergency Telephone: 800-942-3166
Sodium Aluminum Tetrafluoride
In an emergency, call CHEMTREC at 800-424-9300 or MEMC Pasadena at 713-740-1501 NaAlF 4 HEALTH FLAMMABILITY 2 0 2 0 0 PHYSICAL HAZARD 0 PERSONAL PROTECTION SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Compressed Gas Cylinder Safety Guidelines
Compressed Gas Cylinder Safety Guidelines I. Introduction These guidelines contain information on the proper storage, handling, use and disposal of compressed and liquefied gas cylinders. Information is
GAS CYLINDER SAFETY GUIDELINES
GAS CYLINDER SAFETY GUIDELINES Prepared by: Iowa State University Environmental Health & Safety Ames Laboratory Environment, Safety, Health & Assurance Copyright August 1997 I. INTRODUCTION Compressed
MATERIAL SAFETY DATA SHEET - Air-Compressed
1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: CHEMICAL FAMILY: SYNONYMS: CHEMICAL FORMULA: USE: NAME AND ADDRESS: Air, compressed Air Nonflammable gas Medical Air, Breathing Air, Compressed
Propane Fuel. Material Safety Data Sheet
VICTOR Material Safety Data Sheet SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION Product Name: Liquefied Petroleum Gas or Propane (0916-0004) (0056-1297) Product Use: Heating Fuel Synonyms: Propane, LP-Gas,
Questar Safety Data Sheet
Page 1 1. Product and Company Identification Product Name: Natural Gas (with and without the addition of an odorant) Synonyms: Methane; NG (CNG when compressed) UN Number: 1971 Recommended Use: Fuel Gas
ICC CODE CORNER 2012 IFC Code & Commentary
SECTION 908 EMERGENCY ALARM SYSTEMS 908.1 Group H occupancies. Emergency alarms for the detection and notification of an emergency condition in Group H occupancies shall be provided as required in Chapter
Safety Data Sheet. Product #: 300178. Aspira Scientific 521 Cottonwood Dr. Milpitas, CA 95035 408.571.1100 [email protected] www.aspirasci.
Safety Data Sheet Aspira Scientific 521 Cottonwood Dr. Milpitas, CA 95035 408.571.1100 [email protected] www.aspirasci.com Section 1: Product Identification Product Identifiers Product Name: L-
WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Product name : WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA- D Recommended use : Hard Surface Cleaner Manufacturer, importer, supplier : S.C. Johnson
A practical guide to restrictive flow orifices
Safetygram 46 A practical guide to restrictive flow orifices Restrictive flow orifices (RFOs) installed in cylinder valve outlets provide a significant safety benefit for users of hazardous gases, especially
Material Safety Data Sheet
Product Name Supplier Synonym MSDS# Date of Preparation/Revision In case of emergency Material Safety Data Sheet Carbon Dioxide (Dry Ice) Section 1. Chemical product and company identification Physical
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1. PRODUCT IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: FORMULA: SYNONYMS: Helium, compressed Helium He Helium gas, Gaseous helium, Balloon gas MANUFACTURER: Air Products
Compressed Gas Cylinders: Proper Management And Use
General Assistance Office of Environment, Health & Safety 642-3073 Emergency Phone Numbers Emergencies: Life-threatening Emergency or Imminent Hazard to the Environment 911 From cell phone 642-3333 Non
GUIDELINES FOR THE LOCATION OF STATIONARY BULK AMMONIA STORAGE FACILITIES
GUIDELINES FOR THE LOCATION OF STATIONARY BULK AMMONIA STORAGE FACILITIES In accordance with Part 1, Section 4 of the Clean Air (General) Regulations, being Alberta Statute 216/75, the Department of the
Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue
Page 1 of 5 MSDS Document Product 1. Chemical Product and Company Identification Trade Name of this Product Manufacturer Contact Name Lawson Products, Inc. Corporate Compliance Team 1666 East Touhy Avenue
SCBA Frequently Asked Questions
SCBA Frequently Asked Questions Q. WHEN SHOULD I USE SCBA? A. An SCBA is the choice when dealing with any oxygen deficient atmosphere that is IDLH (Immediately Dangerous to Life or Health), or any environment
Training Requirements for the Revised Hazard Communication Standard
www.alterisus.com Training Requirements for the Revised Hazard Communication Standard As of December 1, 2013 OSHA revised its Hazard Communication Standard (HCS) to align with the United Nations Globally
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1. PRODUCT IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: Nitrogen, compressed Nitrogen FORMULA: N 2 SYNONYMS: Nitrogen gas, Gaseous Nitrogen, GAN August 1997 MANUFACTURER:
Glutaraldehyde Policy
Virginia Commonwealth University Office of Environmental Health & Safety Chemical/Biological Safety Section Glutaraldehyde Policy (revised 10/13/09) Table of Contents (Sections) 1. Purpose 2. Scope 3.
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET I. PRODUCT & COMPANY IDENTIFICATION Product Name: Banana Boat UltraMist Kids Spray SPF 50 Product Code(s): 92122940 Product Type: Sunscreen Supplier Address: Playtex Manufacturing
FLAMMABLE LIQUIDS COMPLIANCE NOTE
Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic
Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family
Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET I. PRODUCT & COMPANY IDENTIFICATION Product Name: Banana Boat Natural Reflect Lotion SPF 50+ Product Code(s): 92006370 Product Type: Supplier Address: Sunscreen Playtex Manufacturing
THE UNIVERSITY OF MAINE COMPRESSED GAS CYLINDERS FOR SCUBA DIVING
THE UNIVERSITY OF MAINE COMPRESSED GAS CYLINDERS FOR SCUBA DIVING Department: The University of Maine Safety and Environmental Management Department Page i TABLE OF CONTENTS Section Title Page 1.0 Purpose
HAZARD COMMUNICATION: NEW LABEL ELEMENTS AND SAFETY DATA SHEET (SDS) FORMAT
HAZARD COMMUNICATION: NEW LABEL ELEMENTS AND SAFETY DATA SHEET (SDS) FORMAT AGENDA Hazard Communication Recent Changes Pictograms New Label Format Signal Word Safety Data Sheets 2 HAZARD COMMUNICATION:
Material Safety Data Sheet
Material Safety Data Sheet NFPA HMIS / WHMIS PPE Transport Symbol Revision Number 1 1. PRODUCT AND COMPANY IDENTIFICATION Product Name Product Code(s) Product Type Manufactured by: PRSL72459CN Polyester
Material Safety Data Sheet
Material Safety Data Sheet Section 1 General Information Manufacturer: Rust-Oleum Corporation 11 Hawthorn Parkway Vernon Hills, IL 60061 24 Hour Assistance: 1-847-367-7700 www.rustoleum.com Date: April
Compressed Gas Cylinder Storage and Handling Guide
Overview Compressed gas cylinders are used in many workplaces to store gases that vary from extremely flammable (acetylene) to extremely inert (helium). Many compressed gas cylinders are stored at extremely
Compressed Gas Cylinder Safety, Management and Disposal
Introduction Compressed gas cylinders are necessary in many campus operations and research. Compressed gases expose users to both chemical and physical hazards. Gases contained within compressed gas cylinders
GSM-12 EMERGENCY SHUTDOWN SYSTEM CONTROLLER. Operations Manual
GSM-12 EMERGENCY SHUTDOWN SYSTEM CONTROLLER for ESO PROTECTED GAS SOURCE EQUIPMENT Operations Manual INT-0301-XX Rev. A Page 1-1 TABLE OF CONTENTS 1 SAFETY 1-4 1.1 Emergency Response 1-4 1.2 Fire Response
WINDEX MULTI-SURFACE CLEANER - VINEGAR
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : Use of the : Hard Surface Cleaner Substance/Mixture Company : S.C. Johnson and Son, Limited 1 Webster Street Brantford ON N3T 5R1
Chemical Fume Hoods. Environmental Health and Safety 974-5084
Chemical Fume Hoods Environmental Health and Safety 974-5084 Regulatory References Prudent Practices in the Laboratory 2011 (National Research Council of The National Academies): Laboratory chemical hoods
COMPRESSED GAS SAFETY
COMPRESSED GAS SAFETY COMPRESSED GAS SAFETY I. Summary Compressed gas cylinders can present a variety of hazards due to their pressure and /or contents. All compressed gases used at UGA must be ordered
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET I. PRODUCT & COMPANY IDENTIFICATION Product Name: Infectiguard Product Type: Hand Sanitizer Supplier Address: Dr Fresh Inc 6645 Caballero blvd. Buena park, CA, 90620 USA Phone:
SAFETY DATA SHEET. 955 Connecticut Ave, Suite 5202 Bridgeport, CT 06607 Tel: 800-242-1150 www.carbtrol.com Date Prepared: July 22, 2015
CARBTROL C O R P O R A T I O N SAFETY DATA SHEET Section 1 Identity Identity (As Used on Label and List): Carbtrol Type: CSV, CV, CSL, CL, CAT2 Manufacturers Name: Carbtrol Corporation 955 Connecticut
FACT SHEET. The following information is available from OSHA s Hazard Communication website, located at OSHA s Website. Hazard Communication Standard
FACT SHEET Modification of the Hazard Communication Standard (HCS) to align with a Globally Harmonized System of Classification and Labelling of Chemicals (GHS) What This Means for Fire and Building Code
HYDROGEN PEROXIDE SOLUTION 3%
MSDS Number: H4070 * * * * * Effective Date: 02/15/08 * * * * * Supercedes: 04/22/05 HYDROGEN PEROXIDE SOLUTION 3% 1. Product Identification Synonyms: Hydrogen Dioxide Solution, 3%; Hydrogen Peroxide Topical
CAS-No. EC-No. Index-No. Concentration Controlled Pore Glass - - - - May be harmful if inhaled. May cause respiratory tract irritation.
SIGMAALDRICH Material Safety Data Sheet Version 3.0 Revision Date 01/03/2009 Print Date 02/18/2009 1. PRODUCT AND COMPANY IDENTIFICATION Product name : Glass beads, acidwashed Product Number : G8772 Brand
Chapter XIV OCCUPATIONAL SAFETY AND HEALTH ACT. The Occupational Safety and Health Act (the Act ), 29 U.S.C. 651, et seq., is
Chapter XIV OCCUPATIONAL SAFETY AND HEALTH ACT The Occupational Safety and Health Act (the Act ), 29 U.S.C. 651, et seq., is administered by the Occupational Safety and Health Administration ( OSHA ) of
FDNY C14 Certificate of Fitness Quiz
FDNY C14 Certificate of Fitness Quiz Name: Date: 1. Who issues a New York City laboratory permit? a) Department of Environmental Protection (DEP) b) Department of Environmental Conservation (DEC) c) Occupational
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET I. PRODUCT & COMPANY IDENTIFICATION Product Name: Banana Boat UltraMist Soothing Aloe After Sun Spray Gel Product Code(s): 7960 Product Type: After Sun Product Supplier Address:
1. Chemical Product and Company Identification. 2. Hazardous Ingredients
1. Chemical Product and Company Identification Product Name Company Name Company Name Website Houghton International Inc. Madison & Van Buren Aves Valley Forge, PA 19482 Houghton Canada Inc. 115 Walker
Compressed Gas Cylinders Safety Policy
Compressed Gas Cylinders Safety Policy This is an example of a compressed gas safety policy for a client whose operations include welding. Oxygen and acetylene tanks are in use and in storage at this client's
MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid
SECTION I- Product Information* MANUFACTURER: EPCO Carbon Dioxide Products, Inc. OFFICE PHONE: 1-800-259-3726 24-HOUR EMERGENCY: 1-800-259-8095 SHIPPING NAME: Carbon Dioxide, Refrigerated Liquid UN NUMBER:
Environmental Health and Safety. Laser Safety Guide. Environmental Health and Safety
Environmental Health and Safety Standard Operating Guideline Laser Safety Program Laser Safety Guide Environmental Health and Safety 1.0 Purpose and Requirements This guide presents a summary of the basics
WINDEX ORIGINAL GLASS CLEANER
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : Use of the : Hard Surface Cleaner Substance/Mixture Company : S.C. Johnson and Son, Limited 1 Webster Street Brantford ON N3T 5R1
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Material Safety Data Sheet
Material Safety Data Sheet STAINLESS STEEL CLEANER & POLISH 1. Trade name of product Product use Code Date of issue Product and company identification Product dilution information STAINLESS STEEL CLEANER
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture
Revision Date: 05/19/2015 Date of issue: 05/19/2015 Version: 1.0 SECTION 1: IDENTIFICATION 1.1. Product Identifier Product Form: Mixture Product Name: 10X Spheroid Formation ECM Product Code: 3500-096-01
PortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
TABLE OF INITIAL ISOLATION AND PROTECTIVE ACTION DISTANCES
Page 302 ID No. NAME OF MATERIAL TABLE OF INITIAL ISOLATION AND IVE ACTION DISTANCES SMALL SPILLS (From a small package or small leak from a large package) in all Directions persons Downwind during- LARGE
LISLE CORPORATION. Safety Data Sheet Issued: May 25, 2015 Supersedes: March 15, 2014. Page 1. Section 1 - PRODUCT AND COMPANY IDENTIFICATION
LISLE CORPORATION Section 1 - PRODUCT AND COMPANY IDENTIFICATION Safety Data Sheet Issued: May 25, 2015 Supersedes: March 15, 2014 1.1 Product Identifiers Product Name Combustion Leak Detector Fluid Product
WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- Use of the : Hard Surface Cleaner Substance/Mixture Company : S.C. Johnson & Son,
UCLA Policy 811: Environmental Health and Safety
UCLA Policy 811: Environmental Health and Safety Issuing Officer: Assistant Vice Chancellor, General Services Responsible Dept: Environment, Health & Safety Effective Date: September 5, 2007 Supersedes:
CAS-No. EC-No. Index-No. Concentration Benzyl carbazate 5331-43-1 226-230-3 - -
SIGMA-ALDRICH Material Safety Data Sheet Version 3.0 Revision Date 12/24/2008 Print Date 04/02/2009 1. PRODUCT AND COMPANY IDENTIFICATION Product name : Benzyl carbazate Product Number : 17307 Brand :
MURPHY OIL SOAP LIQUID - ORIGINAL
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Product name : MURPHY OIL SOAP LIQUID - ORIGINAL MSDS Number 200000017771 CAS-No. : Not applicable - product is a mixture General Use : A formulated multi-purpose
Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH
Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines Presented by: Shannon E. Newton, MPH, CIH Topics What are these hazards? How can they harm you? Why do we care? How do we tell
SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011
SIGMAALDRICH sigmaaldrich.com Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011 1. PRODUCT AND COMPANY IDENTIFICATION Product name : Product Number : G7253 Brand : Sigma
COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION
COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION ENVIRONMENTAL HEALTH & SAFETY Working Safely with Ultraviolet Radiation Policy and Procedures Purpose: To provide information and guidelines for the safe use
PLEDGE MULTI-SURFACE CLEAN & DUST
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : Use of the : Hard Surface Cleaner Substance/Mixture Company : S.C. Johnson and Son, Limited 1 Webster Street Brantford ON N3T 5R1
Material Safety Data Sheet. Calcium Lactate
Material Safety Data Sheet Calcium Lactate Section 1: Chemical Product and Company Identification Product Name: Calcium Lactate Pentahydrate Chemical Name: Calcium Lactate Pentahydrate CAS No.: 63690-56-21,
WORKING IN CONFINED SPACES GUIDELINES
WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...
Elgin Fire Department
Breathing Operations Elgin Fire Department Safety - Respiratory Protection Program - Self Contained Apparatus (SCBA) Policy # 2024.01 Issued: 09/08/06 Subject: Purpose: Scope: Self Contained Breathing
MATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET I. PRODUCT & COMPANY IDENTIFICATION Product Name: Skintimate Skin Therapy Moisturizing Shave Gel-Skin Moisturizing Product Code(s): 213523 Product Type: Supplier Address: Shaving
READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure
READ FIRST 1. The purpose of a is to save lives by controlling the inherent hazards of a confined space prior to entry. a. If possible, avoid entering a confined space. Every consideration should be given
SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER
SECTION 1 PRODUCT AND COMPANY IDENTIFICATION Product Name : Product Code : A7804F Recommended use : E2 hand wash and sanitizer Product dilution information : Product is sold ready to use. Manufactured
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
Chlorine Gas Detection System Operation & Maintenance
Chlorine Gas Detection System Operation & Maintenance Maynard King K&D Pratt Instrumentation 2011 Clean and Safe Drinking Water Workshop Chlorine Gas Detector Operation, Maintenance, Checks 1. Why you
MATERIAL SAFETY DATA SHEET High Pressure Laminate Fire Retardant
SECTION I - PRODUCT INFORMATION PRODUCT NAME: Nevamar High Pressure Decorative Laminate -- NEMA Grades SGF, HGF, VGF and SP125 FR Laminate CHEMICAL NAME: Laminated Plastic CHEMICAL FAMILY: Plastic Composite
COMPOSITION / INFORMATION ON INGREDIENTS
MATERIAL SAFETY DATA SHEET DAMTITE WATERPROOFER- WHITE 01071, 01211, 01451 DAMTITE POWDER FOUNDATION WATERPROOFER GRAY 02451 SECTION I. COMPANY & PRODUCT INFORMATION Product Identification Manufacturer