Instructions Chain drive series HCM. Type: HCMA(R) (230 V AC)



Similar documents
Instructions Chain drive series HCV. Type: HCV (24 V DC)

Infrarot-Bewegungsmelder IP44

Air damper actuators

SVR 12/24V and SVR Akku 12V Installation instructions

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Operating Instructions

The future electrical opening system for skylights, smoke hatches and windows

Drayton Digistat +2RF/+3RF

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Duct Humidity Transmitter

Operating Instructions

DALI RC BASIC SO. Control unit Operating instructions

StructureScan HD Module. Installation Guide ENGLISH

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Digital input modules

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Manufacturer s Declaration of Conformity

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Manuale di istruzioni per l uso. INSTRUCTION MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES Инструкция по монтажу

Floodlight Range Installation Guide

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Machine Documentation BELKI Oil Separator type 301

AXIS T81B22 DC 30W Midspan

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

FLEXIT S4 R S6 R S7 R

Page 1. Description

Machine Documentation

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Manual & Technical Documentation V1.1

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Manual. Solar Fountain Mobile Phone Charger

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

HERZ-Thermal Actuators

User Guide. Model Insulation Tester / Megohmmeter

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

evohome Wireless Radiator Zoning Kit Installation & User Guide

Antenna Splitter ASA 1. Instruction manual

ICON Server box installation manual Rev. 1.1

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Operating Instructions Bedienungsanleitung Mode d emploi

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

RAILWAY TECHNOLOGY INDUCTIVE COMPONENTS INDUKTIVE KOMPONENTEN FÜR DIE BAHNTECHNIK

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Operating instructions II / 2004

ACS-30-EU-EMDR-10-MOD

Terminal Boxes Series 8146

IN-OUT Thermometer with Cable Free Sensor and Clock

A good connection. International approvals.

Kit Watt Audio Amplifier

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

Installation guide H A. HSI hardwired system interface

Operating Instructions Busch-Wächter AGM- 110 MasterLINE Rev

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Digital Keypad Use s Manual

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

Addendum to the Operating Instructions

Smile 11 AS-i Emergency stop with safe AS-i input node

Communication bridge Xcom-MS User Manual

Prüfbericht - Nr.: Test Report No.: /GZF/01-01

How To Drive A Compact Serie 1

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

HOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

FMT600BT Transmitter

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RRV934. Multi-controller. Synco living

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

VAV compact controller KNX / PL-Link

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Telis 4 Soliris RTS Operating and installation guide Ref A

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

GeekDesk Max Instructions for Assembly & Use

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Installation Guide. DEVIreg 530. Electronic Thermostat.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Operating instructions Optical distance sensor O1D100 O1D / / 2012

1. Description. 2. List of Accessories included A B C F G H

ATEX instruction APP pumps

Residual current socket 30mA Order No.:

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transcription:

Instructions Chain drive series HCM Type: HCMA(R) (230 V AC)

Safety Notes - Operating voltage 230 V AC - Connection must be carried out by authorized electricians. - It s necessary to ensure that people keep away from the operation area of the drives. Danger of violent pressure in accessible area! - Use only in dry rooms. Application area - For opening and closing of facade and roof windows - Suitable for natural ventilation Features - Microprocessor controlled BUS-synchronization - Max. 8 drives can be connected with each other - Push/Pull-Force, Opening/Closing-Speed and Stroke length free programmable - Electronic overload protection - Gasket relief after closing - Reduced speed and force during the last 70 mm of closing ( Soft-close ) - Symmetrical chain exit (in proportion to the housing) - Drive is supplied with 2.5 m silicone cable - Different types of brackets available, depends on type of windows and kind of mounting - Integrated radio receiver with remote control (HCMAR) - Receiver is compatible to Wind & Rain Sensor #111960 and #111961 (HCMAR) Technical data - Supply: 230 V AC/0.13 A/50 Hz - Stroke: 300 mm - Speed open/close: 7 mm/s - Soft close distance: 70 mm - Protective class: IP30 - Soft close speed: 3,5 mm/s - Temperature range: -5 C ~ +50 C - Soft close force: 150 N - Force push/pull: 300 N - Locking force: 1000 N - Duty cycle: 30% at 10 min. running time - Lifecycle: >10000 double strokes 2 / 12

Connection for type HCMA in single mode black brown blue yellow/green L N PE white grey L N PE 230 V AC / 50Hz Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux. Don t connect the cabels of white and grey to 230V! Connection for type HCMAR in single mode black brown blue yellow/green L N PE white grey L N PE 230 V AC / 50Hz Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux. Don t connect the cabels of white and grey to 230V! 3 / 12

Connection for type HCMA in synchro mode black brown blue yellow/green L N PE white grey L N PE 230 V AC / 50Hz grey white black brown blue yellow/green Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux or for BUS communication in synchro mode. Don t connect the cabels of white and grey to 230V! 4 / 12

Connection for type HCMAR in synchro mode black brown blue yellow/green L N PE white grey L N PE 230 V AC / 50Hz grey white yellow/green blue brown black Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux or for BUS communication in synchro mode. Don t connect the cabels of white and grey to 230V! 5 / 12

Mounting information Application Bracket Set Order No. Outwards opening window, top hung HMB-HCM-01 390150 Inwards opening window, bottom and side hung HMB-HCM-02 390160 Skylight HMB-HCM-03 390190 HMB-HCM-01 for top hung outwards opening windows 6 / 12

HMB-HCM-02 for bottom and side hung inwards opening windows 7 / 12

HMB-HCM-03 for skylights Please be aware, that in all bracket sets are no screws included. Choose proper screws according to frame material! 8 / 12

Dimensions of type HCMA(R) Function of remote control (only HCMAR) Close Stop Open Red diode Pairing of HCMAR with remote control or wind and rain sensor As standard the HCMAR is delivered with a paired remote control. If the remote control get damaged or lost, order spare part #111890. To pair drive and remote control, please look in the manual for the remote control. Also for the pairing of the HCMAR with the wind and rain sensor #111960 or #111961, please look in the manual for the wind and rain sensors. To get access to the learn button of the receiver in the drive, remove cap on the top of the housing. 9 / 12

Declaration of performance No. 008CPR2013-08-27 (DK) YDEEVNEDEKLARATION IHT. FORORDNING NR. (EU) 305/2011) (UK) DECLARATION OF PERFORMANCE ACCORDING TO REGULATION NO. (EU) 305/2011) (D) LEISTUNGSERKLÄRUNG GEMÄSS DER VERORDNUNG NR. (EU) 305/2011) For produktet: For the product: Für das Produkt: Kædemotor Chain drive Kettenantrieb Type/Type/Typ: HCMA 300/300 og/and/und HCMAR 300/300 Nr./No./Nr.: 304030 og/and/und 305030 Formål: Purpose: Verwendungszweck: Producenten: Manufacture: Hersteller: Elektrisk motor til åbning og lukning af vinduer Electric drive for opening and closing of windows Elektrischer Antrieb zum Öffnen und Schließen von Fenstern Actulux A/S, Haandvaerkervej 2, 9560 Hadsund Denmark System for attestering og kontrol af ydeevne: System for attestation and verification of performance: SYSTEM 1 System zur Bescheinigung und Prüfung der Performance: Det bemyndigede organ TÜV SÜD Product Service GmbH No 0123 gjorde den indledende inspektion af fabrikken og af dennes egen produktionskontrol samt løbende overvågning, vurdering og evaluering af fabrikkens egen produktionskontrol til SYSTEM 1, og følgende vises: The notified body TÜV SÜD Product Service GmbH No. 0123 made the initial inspection of factory and of factory production control, and ongoing monitoring, assessment and evaluation of factory production control to the SYSTEM 1 and the following is displayed: Die notifizierte Stelle TÜV SÜD Produkt Service GmbH Nr. 0123 hat die Erstinspektion des Werkes und der werkseigenen Produktionskontrolle sowie die laufenden Überwachung, Bewertung und Evaluierung der werkseigenen Produktionskontrolle nach dem SYSTEM 1 vorgenommen und Folgendes ausgestellt: Deklarerede ydeevne/declared performance/erklärte Leistung: EC CERTIFICATE OF CONFORMITY NO. E8N 13 04 84583 001 Feature/Feature/Merkmal Ydeevne/Performance/Leistung Specifikation/Specification/Spezifikation EMC/EMC/EMV Class III EN 61000-6-1:2007 og/and/und EN 61000-6-3/A1:2011 Udførelsen af produktet i overensstemmelse med punkt 1 og 2 svarer til den deklarerede ydeevne for nummer 9. Ansvarlig for at skabe denne ydeevnedeklarationen er producenten henvist til punkt 4. Underskrevet på vegne af fabrikanten og navnet på fabrikanten af: The performance of the product in accordance with paragraphs 1 and 2 corresponds to the declared performance for number 9. Responsible for creating this declaration of performance is the manufacturer referred to point 4. Signed on behalf of the manufacturer and the name of the manufacturer of: Die Leistung des Produkts gemäß den Nummern 1 und 2 entspricht der erklärten Leistung nach Nummer 9. Verantwortlich für die Erstellung dieser Leistungserklärung ist allein der Hersteller gemäß Nummer 4. Unterzeichnet für den Hersteller und im Namen des Herstellers von: Hadsund d. 14 May 2013, Jens Buus, Managing director 10 / 12

Notes 11 / 12

Warranty The warranty period is 2 years for all Actulux products from the date of verified handing over the system up to maximal 5 years after the date of delivery if the installation and implementation is performed by an authorized service and sales partner by Actulux. Disposal Electrical equipment, accessories and packaging should be recycled for environment protection! Don't dispose electrical equipment into household waste! Only for EU-Countries: According to the European guideline 2002/96/EG about waste electrical and electronic equipment and its implementation into national law, useless electrical and electronic equipment must be separately collected and recycled for environment protection. Contact Actulux A/S Håndværkervej 2 DK-9560 Hadsund Denmark Fon: +45 98 57 40 90 Fax: +45 96 15 28 00 www.actulux.com 2016 Actulux A/S Revision: B01 211815 Rights to technical modifications reserved 12 7 / 12