Keystone Network Isolator with ESD- and Lightning Protection

Similar documents
EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Cable Discharge Event

Datasheet. PoE Adapters. Provides Earth Grounding and Surge Protection. Helps Protect Against ESD Events. Powers Ubiquiti PoE Devices

Telephone- and leased line modem for industrial applications TD-36

38 Series - Relay interface modules A

RClamp0504P RailClamp Low Capacitance TVS Array

Rack mounted telephone- and leased line modem for industrial applications

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

SDC15. TVS Diode Array for ESD Protection of 12V Data and Power Lines. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

STRATO LED Drivers 70W, Single output

Cisco Unified IP Phone Power Injector

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

1 Form A Solid State Relay

Features. Applications. Truth Table. Close

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Digital input modules

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Video Camera Installation Guide

Optocoupler, Phototransistor Output, 4 Pin LSOP, Long Creepage Mini-Flat Package

STF & STF201-30

RM4TG20 three-phase network control relay RM4-T - range V

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

ADACSNET USB Control Module

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

SURGE PROTECTIVE DEVICES

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Powerline 1200 User Manual

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

PCS0100en Persy Control Services B.V. Netherlands

Actuator-Sensor-Interface

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

RY2 miniature industrial relays

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

49 Series - Relay interface modules A. Features

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Lightning Arresters P KVA P KVA. Description & Installation

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

IFS SP-PoE Splitter User Manual

48 SERIES Relay interface modules 10 A

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Technical Article. EMC filters for medical devices

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

MasterINTERFACE 39 Series - Relay interface modules

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Modular I/O System Analog and Digital Interface Modules

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

LOXONE 12 Channel Amplifier

Quick Connect. quick - simple - efficient.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Processor. Installation Guide

Guidance for upgrading to GB (IEC : 2005, MOD)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Structured Cabling, Earthing & Equipotential Bonding

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Unified requirements for systems with voltages above 1 kv up to 15 kv

Data Sheet. ACPL-077L Low Power 3.3 V / 5 V High Speed CMOS Optocoupler Design for System Level Reliability. Description. Features. Functional Diagram

Long Reach PoE over Coaxial Extender Kit

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Ethernet Cat 5e & Cat 6 Patch Panels

Nexus Technology Review -- Exhibit A

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

My first Hirschmann: The SPIDER family of switches.

Voltage Regulator SPAU 341 C. Product Guide

Energy Management Energy Meter Type EM23 DIN

Three-phase monitoring relay CM-PFE

GEU Port Gigabit Switch

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

AXIS T81B22 DC 30W Midspan

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Transcription:

Keystone Network Isolator with ESD- and Lightning Protection Introduction The Network Isolator is utilized in copper-based network connections (Ethernet), in order to protect a device linked with the network against external voltages of unknown origin. Such unwanted voltages can be caused by installation faults, switching operations, electrostatic discharges, potential differences or lightning strikes, and occur frequently in the building cabling. In addition, network isolators eliminate disturbing low-frequency signal compo- nents. In particular, problems due to mains hum can be prevented through the use of network isolators. Our Network Isolators were originally developed for medical use, but are also implemented in other technical fields. Technology The Network Isolator transmits High frequency alternating current voltages according to the principle of electromagnetic induction in the frequency band used for the transmission of data. Because of this transmission principle it requires no power supply. An installation of drivers is not necessary. The task of a network isolator is to prevent any galvanic (= electrically conducting) connection between the connected devices. Therefore, in addition to the data lines, the cable shielding is also galvanically isolated. Standard Conformity and Certification The Network Isolator meets the requirements of IEC 60601-1:1988 A1:1991 and A2:1995 (2nd Edition), IEC 60601-1:2005 (3rd Edition), IEC 60601-1-1:2000, as well as IEC 60601-1-2:2007, as an electrical separation device, making it suitable for use in medical environments. This is confirmed by our current CE Declaration of Conformity which can be downloaded from our website. All Network Isolators are approved by UL International as Recognized Component under the file number E249126 and are therefore suitable for use in the US and Canadian markets. Apart from the UL approval, the conformity of our Network Isolators to the standards UL 60601-1, CSA 22.2 No.601.1-M90, as well as IEC 60601-1 is confirmed by an independent accredited laboratory. In order to gain access to the certificate, visit the UL Online Directory or contact us directly. Applications Medical electrical devices and systems, where patients must be protected against leakage currents. Applications, in which valuable devices or those requiring special protection need to be protected against ripple and surge voltages from the network periphery. Electrical measuring and monitoring equipment, which needs to be protected against external and interference voltages. Computer systems, which are galvanically connected with each other over significant distances via Ethernet cabling and in which equipotential bonding currents are to be prevented. Audio applications, in which the transmission of low frequency alternating current voltages (mains hum) over the network connection is to be reduced to an imperceptible level. Fixed Installation The fixed installation of a network isolator in the wall outlet socket reliably prevents the required galvanic isolation between data network and medical device from being forgotten in the hustle and bustle of everyday medical routine. Therefore, medical devices which require an external galvanic isolation from the Ethernet, as well as standard PCs connected to medical electrical systems, can all be safely and conveniently connected to the Ethernet. Incorporation into Medical Devices (OEM) For medical devices, supply systems and medical equipment carts which provide an Ethernet interface, electrical separation of the interface is usually stipulated. Here, installed network isolators form an ideal solution for original equipment manufacturers, fulfilling the requirements of relevant standards and regulations. 25/01/2012 Page 1

ESD- and Lightning Protection The transformers within the Network Isolator already provide an effective protection against voltage surges of up to 10,000 volts. Brief over-voltage pulses (voltage transients), which are caused for example by electric switching, lightning, or electrostatic discharges, can however overcome the transformer under certain circumstances. Although the pulse voltages will be strongly attenuated, voltage levels can still be reached which could cause damage to the connected devices. The TVS diode circuitry incorporated into the isolator is capable of reducing the transmit ted pulse energies and voltages to safe levels. Impulses of up to 300W can be dissipated by the integrated TVS diodes before reaching the connected devices. The RJ45 socket is also practically potentialfree and therefore prevents spikes due to static discharges when plugging in the cable (ESD and CDE). The is therefore recommended for applications in server rooms, laboratories, workshops or office environments, for devices with especially sensitive terminals, or requiring extra protection. For every device connected to the Ethernet a degree of protection is ensured, conforming to the stringent requirements of IEC61000-4-2 (ESD; 15kV Air / 8kV Contact), IEC 61000-4-4 (EFT;40A, 5/50ns) and IEC 61000-4-5 (Lightning; 12A 8/20 µs). Performance A new transmission technology has been developed, which for the first time allows an Ethernet cable route of up to 90m (Permanent Link) equipped with a Network Isolator to be certified according to ISO 11801/EN 50173 Class D or TIA 568B Cat.5e for Gigabit Ethernet. The Network Isolator is however an additional component in the wiring route. In order to achieve certification in accordance with Class D / Cat.5e standards, the existing cable route must therefore provide a small reserve in network performance. The exact requirements for this Class D/Cat.5e performance reserve can be found in the installation instructions. We recommend using Cat.6A components when establishing new network wiring routes which are to be fitted with our Network Isolators. Compliance Tests Permanent network installations, fitted with an Network Isolator, can be checked with cable certification devices which are suitable for testing electrically isolated cable sections. For example, Fluke produces a range of DTX Cable Analyzers, suited to such tests. These devices must have their Twisted Pair configuration changed - the AC Wire Map needs to be Enabled. The entire cable route, including the Network Isolator, can be tested to TIA 568 Cat.5e or ISO 11801 Class D. Testing of the cable shielding and the conductor resistance is not possible in this mode. If however, these tests are required, or if the quality of the cable route itself needs to be tested (without the Network Isolator), then testing can be performed by bypassing the Network Isolator, and connecting directly to the RJ45 socket, set back within the cable duct. Plugging Cycles and Faulty Plugging Especially in the medical environment, there are many mobile devices which must be frequently plugged and unplugged. In this field, Ethernet interfaces are therefore more greatly stressed than in an office environment. For this reason, the contacts of the Network Isolator are provided with a particularly thick layer of gold (50µm), which ensures a perfect contact, even after many hundreds of plugging operations. Connector plugs of telephones, fax machines, or modems (RJ11, RJ12, or RJ25) are indeed constructed narrower and have only a maximum of 6 contacts, but because of their very similar design can be plugged into RJ45 sockets by mistake. With conventional sockets this often leads to damage to the contacts and subsequently to faulty contacts. Through its robust design, the Network Isolator withstands up to 100 such faulty plugging operations without damage. Design The Network Isolator is a Keystone module. It therefore fits into every outlet panel, whose module receptacle conforms to the Keystone specifications, and can be combined with Keystone-compatible outlet covers and module brackets of most manufacturers. Its small size is especially suitable for use in dado trunking, equipment carts, and medical supply systems. The Network Isolator has a flexible connector cable. This patented design (German Patent DE102007025160] offers several advantages: The Network Isolator can easily be retrofitted in existing Key- stone installations. To do this, the existing Keystone module must merely be shifted back within the cable duct. The Network Isolator replaces the original module in the outlet cover. Fixed installations can be laid with future-proof Cat.6a cabling, and can later be certified by bypassing the network isolator, easily connecting to the set-back original socket. Consequently, installation firms can fulfil the specifications for the fixed cabling, while still meeting their obligation to provide documented certification. Safety inspections can be carried out via an inspection cover directly at the place of installation. In contrast to a socket or an insulation displacement connection, the flexible connector cable enables a physically short design. Installation Notes It is recommended to keep the RJ45 socket between fixed cabling and Network Isolator accessible, in order to be able to carry out certification and to facilitate maintenance. This can be achieved with an inspection cover. The standard cable length is 20cm. Other cable lengths are available. A network isolator is designed for the transmission of data in the frequency range between 300kHz and 100MHz. Lower frequencies are strongly attenuated. 25/01/2012 Page 2

For this reason it is normally not possible to transmit signals from nurse call systems, TK-installations or analog video signals over a network isolator. The Network Isolator can be used in a PoE network without restriction; however due to the galvanic isolation, PoE devices can generally not be supplied with power through a network isolator. If it is intended that two or more Network Isolators will be installed side by side into multiple module carriers, and that non-medical devices are to be plugged into these Network Isolators, the mounting distance "D" must be taken into account (see drawings). To ensure creepage distances in accordance with IEC 60601-1, the minimum centre-to-centre distance "D" is 20mm for protected devices with operating or supply voltages of 250VAC, and 24mm for protected devices with 400VAC. Crucial to this distance is the dimension "X", which marks the shortest distance between the shield plates of the inserted RJ45 plugs. This distance "X" must not fall short of 8mm (250V), or 12mm (400V), as appropriate. By extending the creepage and clearance distances between the plugs (e.g. by means of intermediate insulating strips), the distance "D" may be reduced down to 17.5 mm. Combinations of Network Isolators and non-galvanically isolated Keystone modules within multiple module car- riers are not recommended. For the electrical tests a test device for testing the electrical safety according to EN 60601 or VDE0751 is required. The Network Isolator is connected to this test device at both sides with a suitable test adapter. The test adapter connects all conductors, including the cable shield, to the test device. Suitable test adapters are available from us upon request. Safety Inspections Safety inspections are not prescribed for network isolators in medical use, as network isolators themselves do not fulfil any diagnostic or therapeutic purpose, and therefore are not classified as medical products. However, together with a connected medical device, network isolators form a medical electrical system, which altogether may be subject to inspection. For this reason, safety inspections on network isolators are meaningful where the risk of an inadmissible electrical stress of the patient should be reliably excluded throughout the path of the Ethernet connection. The following checks are recommended: 1. The device is to be checked for external damage by means of visual inspection. 2. Inspection for foreign objects, especially liquids. 3. Function test 4. Insulation test 5. Availability and completeness of the documentation. 25/01/2012 Page 3

14.6 17.3 16 Keystone Cut-out 3.2 17.4 +0.16 Installation Drawings All dimensions in mm. +0.14 14.9-0.12 Installed data cable 39.9 19.45-0.15 Earthing connection (optional) Channel cover Module bracket Keystone module RJ45 Plug +0.16 1.38-0.16 Connection cable 1.75 Inspection cover (optional) 9.7 30.3 D Keystone outlet cover Network Isolator 25/01/2012 Page 4

Technical Features Standard or Test Criterion Designation Housing colour Design t.b.d. White, similar to RAL9010 Keystone module RJ45 with connector cable and RJ45 plug Cable length Length of the flexible section 20cm (other lengths available upon request) Supported network protocols IEEE802.3 10BASE-T (Cl.14), 100BASE-TX (Cl.25), 1000BASE-T (Cl.40) Ethernet performance ISO11801; EN50173; TIA568B Class D/Cat5e achievable in Permanent Link Attenuation (Insertion Loss) 1MHz < f < 100MHz < 1dB (for 20cm cable length) Suitable for the protection of Ethernet interfaces of medical devices Provided isolation distances Isolation Dielectric strength EN 60601-1:2006 / EN60601-1-1:2002 / UL 60601-1 ME-devices of protection class I + II + independent power supply; with application parts B, BF and CF 12mm clearance / 7mm creepage Reinforced AC: 6kV @ 50Hz / 1min DC: 8.5kV Total leakage current 275V AC, 50Hz 12.5µA ±25% Coupling capacitance 275V AC, 50Hz 37.5pF / Channel ±25% (150pF total) Max. working voltage (max. mains voltage) of the connected devices EN 60601-1:2006 / EN 60601-1-1:2002 / UL 60601-1 400VAC / 450VDC Plugging cycles RJ45 Plug to RJ45 socket > 1000 Mismatched connector plugging cycles with RJ11/RJ12/25 connectors Up to 100 Housing dimensions: W H D Housing without cable 17.3mm 24mm 39.9mm Min. cable bend radius Max. short-term tensile cable strength 25mm 70N for < 10s Protection rating DIN EN 60529 IP20 Protection against transient voltages Line to Line TVS Diode Circuit Max. pulse power (tp=8/20µs) P pk 300W Reverse blocking voltage V RWM 5V I PP = 1A, tp=8/20µs 12.5V Clamping voltages I PP = 5A, tp=8/20µs 17.5V I PP = 12A, tp=8/20µs 25V Markings Environmental conditions (operation) Environmental conditions (storage and transportation) Temperature Humidity Air Pressure Temperature Humidity Air Pressure CE, UL, RoHS conformity, lead-free 10 to 45 C 10 90% (non-condensing) 860 to 1060hPa -10 to 75 C 10 90% (non-condensing) 600 to 1060hPa 25/01/2012 Page 5

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RJ45 Jack 9 10 11 12 13 14 15 16 Frequency response: Return Loss and Insertion Loss 5 db 0.25 db 10 db 0.50 db Insertion Loss Return Loss 15 db 0.75 db 20 db 1.00 db 25 db 1.25 db 30 db 1.50 db 35 db 1.75 db 40 db 2.00 db 45 db 2.25 db Measured with Fluke DTX 1800 Cable Analyzer Wiring Diagram Ethernet Transient Voltage Supressors "Medical" Class D LAN Transformer 2 1 4 Cable 5 Green/White Green Orange/White Blue Blue/White 3 Orange 6 7 Brown/White Brown RJ45 Plug (TIA 568A) 8 Plastic Housing 25/01/2012 Page 6