GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs



Similar documents
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Pesticide Analysis by Mass Spectrometry

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Analyzing Small Molecules by EI and GC-MS. July 2014

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Fractional Distillation and Gas Chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

AMD Analysis & Technology AG

23 The Thermal Conductivity Detector

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Analysis of Phthalate Esters in Children's Toys Using GC-MS

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Expectations for GC-MS Lab

Application Note. Abstract. Authors. Food Safety

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Background Information

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Determination of Polycyclic Aromatic Hydrocarbons (PAH) in Food with GC-MS/MS

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

High-Throughput 3-D Chromatography Through Ion Exchange SPE

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

SCION SQ Series GC-MS

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Gas Chromatography Liner Selection Guide

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Application of Structure-Based LC/MS Database Management for Forensic Analysis

How To Use Gc-Ms

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

LC-MS/MS for Chromatographers

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

13C NMR Spectroscopy

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Appendix 5 Overview of requirements in English

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

CLEAN-UP PROCESS FOR MASS SPECTRAL STUDY OF AMPHETAMINES IN PUTREFIED BODY MATERIALS

New drugs of abuse? A case study on Phenazepam & Methoxetamine

PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS

Signal, Noise, and Detection Limits in Mass Spectrometry

Analysis of Liquid Samples on the Agilent GC-MS

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Micromass LCT User s Guide

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Opiates in Urine by SAMHSA GC/MS

Split / Splitless Injection for Capillary GC

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

How To Build An Amd Quas 3 Ar Mass Spectrometer

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

How To Test For Contamination In Large Volume Water

A Complete Solution for Method Linearity in HPLC and UHPLC

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Protocol: HPLC (amino acids)

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Chemical analysis service, Turner s Green Technology Group

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Setting up a Quantitative Analysis MS ChemStation

Tuning & Mass Calibration

Alignment and Preprocessing for Data Analysis

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

ApplicationNOTE Introduction

Transcription:

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs Kinet C, De Pauw E, Focant JF CART, Mass Spectrometry Laboratory, Chemistry Department, University of Liège, Allée de la Chimie 3, B-6c Sart- Tilman, B-4000 Liège, Belgium Abstract The paper describes preliminary data for the use of comprehensive two-dimensional gas chromatography (GCxGC) coupled to fast scanning quadrupole mass spectrometry (MS) for the measurement of dioxins and PCBs in biological samples. Electron impact (EI) and negative chemical ionization (NCI) are used and evaluated in terms of quantification using isotope dilution. Introduction As an alternative to the complex reference gas chromatography coupled to isotope dilution high resolution mass spectrometry (GC-IDHRMS) approach, new analytical methods are explored. Based on our previous investigations on the use of comprehensive two-dimensional GC coupled to time-of-flight MS (GCxGC-IDTOFMS) for the measurement of POPs 1, we currently evaluate the capabilities of GCxGC coupled to fast scanning low resolution quadrupole MS (qms). The qms can scan at up to 50Hz when operating in selected ion monitoring (SIM), offering the required sampling rate for narrow GCxGC peak characterisation. This instrument offers both electron impact (EI) and negative chemical ionization (NCI) to produce ions in the source. Advantages of NCI are known for a long time in terms of PCB analysis but it often suffers of lack or reproducibility and can make ID measurement difficult because of the limited availability of target ions. Both ionizations methods are investigated to evaluate the potential advantage of using GCxGC and NCI with this specific instrumental setup. Materials and Methods Chemicals, consumables and samples All information on solvents, sorbents, labeled standards, equipments, and quality control (QC) procedures can be found in previous reports 2,3. QC samples consisted in beef fat fortified with PCDD/Fs and PCBs. The mean level was 2.9±0.18 pg TEQ/g fat for PCDD/Fs, 1.2±0.06 pg TEQ/g fat for NO-PCBs, and 0.33±0.16 pg TEQ/g fat for MO- PCBs. QC samples were stored at -20 C prior to analysis. QC sample sizes were 20 g. Sample preparation Procedural blanks (both instrumental and method) and quality control (QC) samples were analyzed for the investigation. Our in-house QC samples were directly dissolved in hexane and processed through the clean-up system. The clean-up and fractionation in sub-groups of analytes was performed by automated multi-sorbent (silica, alumina, and carbon-based) liquid chromatography (LC) using the Power-Prep System (FMS Inc.). Sizes of Teflon disposable columns are available elsewhere 3. The total run time was 100 min, plus a preventive decontamination program of 15 min. The MO- and I-PCBs were isolated in 120 ml of hexane-dichloromethane (1:1) and the PCDD/Fs and NO-PCBs were collected in 80 ml of toluene. Evaporation using a TurboVap II Workstation and a RapidVap was performed after addition of nonane as keeper. The final volumes were 90 µl for the MO- and I-PCBs fraction and 5 µl for the PCDD/Fs and NO-PCBs fraction. 5 µl of syringe (recovery) standards were added to the Vol. 71, 2009 / Organohalogen Compounds page 002474

GC vials prior to injection. All samples were analyzed by GC-IDHRMS 3 to produce reference values for comparison purposes. GCxGC The GCxGC hardware was the Zoex Loop Modulator (ZX1 - LN 2 Cooled Loop Modulation GC x GC System, Zoex Corp., Houston, USA). The simple setup is illustrated in Figure 1. Delay Loop Cold Jet Nozzle 1 st Stage Hot Jet Cold Jet 2 nd Stage Figure 1: Schematic of the Loop Modulator (Source: Zoex Corp.). The modulator was mounted on the Shimadzu GC oven and liquid nitrogen was used to create the cold jets. The column set was made of a 30m STX-500 (0.25 mm ID x 0.15 µm df) (Restek Corp.) in the first dimension ( 1 D) and either a 2m Rxi-17 (0.18 mm ID x 0.18 µm df) (Restek Corp.) or a 2m BPX-50 (0.10 mm ID x 0.10 µm df) (SGE) in the second dimension ( 2 D). The modulation period (P M ) was 4s. The hot pulse duration was 375ms. Helium was used as the carrier gas at a constant flow rate of 1.2 ml/min. 1.0 µl of the final extract in nonane was injected into a split/splitless injector held at 275 C in splitless mode. The primary oven was programmed as follows: 140 C for 2min, at 15 C/min to 220 C, at 7.5 C/min to 250 C, at 2 C/min to 265 C, at 28 C/min to 320 C for 5min. No secondary oven was used. The modulator temperature offset was 60 C. Quadrupole MS The MS was the Shimadzu QP2010 Plus (Smimadzu, Duisburg, Germany). The MS transfer line temperature was 300 C. The ion source temperature was 220 C with an EI energy of 70eV. For SIM data acquisition, 4 masses (2 natives and 2 labels) were collected for each chlorination level. The scan rate was 25 Hz and the detector voltage was 1400V. For full scan data acquisition, the collected mass range was 30 500amu. The scan rate was 18 Hz and the detector voltage was 1100V. NCI was performed using methane as reagent gas. Data processing and display of the GCxGC chromatograms were achieved using both Shimadzu GCMS Solution software version 3 and GC Image software (Zoex Corp.), version 1.9. The quantification was performed in Excel spreadsheets after exportation of area measurements from GCMS Solution software. Results and discussion The stability of MS system was first investigated in regular GC to estimate the repeatability of measurements. A mass calibration tune was performed regularly and did not show any significant deviation over time. A selected standard solution injected twice a week for one month did show good response stability (Figure 2). All GCxGC parameters were optimizes to reproducibly produce narrow 2 D peaks. Three to four slices per peak were obtained for all analytes. The classical peak width in 2 D was 600ms. This resulted in a number of 10-15 scans across each slice and a good description of the peak shape for the scan rates that were used. Spectral quality of this scanning Vol. 71, 2009 / Organohalogen Compounds page 002475

instrument is good and allows proper quantification performances. Typical scanning MS mass skewing was observed across GC peaks but did not affect the quantification. Area Ratio 0,075 0,07 0,065 0,06 0,055 0,05 0,045 0,04 1st injection 2nd injection 3rd injection 4th injection 5th injection 6th injection 7th injection 8th injection 9th injection PCB123 Average Upper Limit 99% Lower Limit 99% Figure 2: Stability of the ion ratio for 1pg native solution over one month period. When using both EI or NCI, isotope dilution quantification can be performed under good QA/QC criteria. For quantification, the two most intense ions for the natives and the two most intense ions for the label were followed. This permitted a maximum scan rate of 25 Hz. Calibration curves were established the same way we do for the accredited GC-IDHRMS method. Ion ratios were checked and showed to be within a 20% range from theoretical ratios for both EI and NCI. Good correlation coefficients were obtained. Figure 3 illustrates the GCxGC-NCI-qMS slice cluster corresponding to hexa-chlorinated PCB with a focus on PCB- 156 and showing traces for the four monitored ions extracted from collected full-scan data. 359.80 (1.00) 361.80 (1.00) 4.5 371.90 (1.00) 373.90 (1.00) 4.0 3.5 3.0 2.0 1.5 1.0 0.5 0.0 21.925 21.950 21.975 22.000 22.025 22.050 22.075 22.100 Figure 3: GCxGC peaks based on specific ions extracted from full-scan data. Vol. 71, 2009 / Organohalogen Compounds page 002476

Preliminary quantification data show good correlation with reference GC-HRMS data. QC charts testify for the good correlation between reference values and GCxGC values on a total MO-PCB TEQ basis (Figure 4). 0,47 0,42 Concentration (pgteq/g) 0,37 0,32 0,27 0,22 QCG-06-36 QCG-06-115 QCG-06-011 QCG-06-109 QCG-06-26 QCG-06-031 QCG-06-54 QCG-06-064 QCG-06-032 QCG-06-62 QCG-06-57 QCG-06-93 QCG-06-96 QCG-06-117 QCG-06-052 QCG-06-130 QCG-06-072 06-117-GCxGC-EI-qMS 06-18-GCxGC-EI-qMS 06-117-GCxGC-NCI-qMS 06-96-GCxGC-NCI-qMS Figure 4: QC chart for MO-PCBs in GC-IDHRMS (Triangle are GCxGC-EI date, Ball are GCxGC-NCI data). The use of NCI has the advantage of increasing the sensitivity. The same S/N ratio (S/N = 150 for the higher peak of the cluster for 1 pg injected) were obtained for SIM GCxGC-EI-qMS and for full-scan GCxGC-NCIqMS. Performing SIM GCxGC-NCIqMS would definitely yield to low pg sensitivity. For NCI runs, we actually had to lower the detector voltage to avoid saturation for some congeners. The injection volume was then f increased to 2 µl or the standards to ensure proper signal. A potential issue with NCI is however the low intensity of parent ion cluster for low chlorination level. This obviously makes ID quantification more delicate or even impossible in some extreme cases. As illustrated in Figure 5, quantification based on parent ions was only possible from penta-chlorinated to higher level of chlorination. A complete optimization of the ionization parameters (source temperature, reagent gas, gas pressure, ) is under consideration to optimize mass spectral quality and estimate if ID can still be performed in good conditions. Nevertheless, those preliminary results encourage us to pursue in this direction and fully optimize SIM GCxGC- NCIqMS to attempt a validation study for quantification of PCBs and dioxins in biological samples. References 1. Focant J.-F., Sjödin A., Turner W.E., Patterson Jr. D.G. Anal. Chem. 2004;76:6313. 2. Focant J.-F., De Pauw E. J. Chromatogr.B. 2002;776:199. 3. Focant J.-F., Eppe G., Pirard C., DePauw E. J. Chromatogr.A 2001;925:207. Vol. 71, 2009 / Organohalogen Compounds page 002477

5.0 (x10,000) 35.0 180.203.1 71.0 98.0 114.1 157.0 0.0 259.0282.1 336.2361.1 412.3438.1 469.1 510.2 (x10,000) 7.535.0 5.0 325.9 0.0 67.9 84.0 102.1 144.0 179.9207.0232.1 283.1 388.1412.2 465.2 506.4 359.8 357.8 35.0 0.0 78.8 123.1 142.0 162.1 194.1222.0 262.1 306.2 325.9 388.3 430.2452.2477.3 510.3 393.8 5.0 359.8 35.0 357.8 0.0 79.0 126.9 162.0 202.0 239.0262.1 302.1325.9 427.1 466.4 510.4 Figure 5: NCI (methane) mass spectra for different chlorination of PCBs (from top to bottom: tetra, penta, hexa, hepta). Vol. 71, 2009 / Organohalogen Compounds page 002478