Intellis Network Control Monitors Non-hazardous, Intrinsically Safe, Explosionproof/Flameproof - ATEX/IEC

Similar documents
Tyco PremiAir Pneumatic Actuators

Using installed Fieldbus Wiring to carry Ethernet Communications

S-series DeviceNet Interface Card

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Worcester DS/DM Series UltraSwitch Switch box

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Introduction to the Actuator Sensor-Interface

ICoT Smart Positioners Intrinsically Safe, Explosionproof - ATEX/IEC/INMETRO

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Solenoid Valve Island Type 3965

TX OPEN RS232/485 module

Combi switchbox with integrated 3/2 way pilot valve

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Understanding Device Level Connection Topologies

S-series SQ Controller

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

2.12. page Products for Explosion hazardous Environment

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

TURCK Modular Industrial I/O PROFIBUS -DP Products

Introduction to PROFIBUS and PROFINET

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Barcode Reader Series BCL 31, BCL 32, BCL 34

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Bus modules systron PM

PROFIBUS fault finding and health checking

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Electric Rotary Actuator - On/Off or programmable control actuator

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Process Control and Automation using Modbus Protocol

Electro-Pneumatic Bus Door Control Mechanism

Single sub-base valve

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

SOLENOID VALVES AND PNEUMATIC VALVES

M-series Virtual I/O Module 2

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Automatic Fire Fighting Monitors

EDI Distributor Control Interface Wiring and Setup Instructions

API Marine. BMS Presentation. Ballast Measurement Systems

Centro-Matic Automatic Lubrication Systems System Controls

How To Use A Ds340 (Dsp)

40.3. Control Relays and Timers

type V46, solenoid or pneumatic operated

PROFIBUS AND MODBUS: A COMPARISON

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

mpm DIN CONNECTORS

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Control- and feedback head for integrated mounting on Robolux valves Type 2036

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

O C M III. Open Channel Flow Monitor

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Understanding Device Level Connection Topologies

Microcor Wireless Transmitter (MWT)

Square D Model 6 Motor Control Centers

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

In-Sight Hardware specifications

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Technical data sheet TDS0070

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Product Information Fire alarm panel 8000 C

4/2-Way Pneumatic Solenoid Valve

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

G3 Series PROFIBUS DP Technical Manual

Inductive sensor NI10-M18-Y1X-H1141

Technical Information RIA14

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Natural Gas Well Automation using Kingfisher RTU Products

Modbus and ION Technology

Explosion proof enclosures

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Modular I/O System Analog and Digital Interface Modules

Compact pressure switch Flameproof enclosure Ex d Model PCA

Integrating your automated valves for. Improved process performance

Signal Tower modulsignal50

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Solenoid Valve Type 3962

TorqPlus TM Electric Valve Actuators and Controls

Unidirectional Transmitter/ Receiver Units Introduction

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

BNI EIP Z009 IP67 Module, Unmanaged Switch

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

DeltaV SISnet Repeater

Research of PROFIBUS PA s integration in PROFINET IO

A descriptive definition of valve actuators

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SCADA System Fundamentals

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Transcription:

Non-hazardous, Intrinsically Safe, Explosionproof/Flameproof - ATEX/IEC Intellis is a family of fully-integrated control monitors that provide cost-effective valve automation and intelligent networking via the major network protocols. Features Dedicated network modules (PACs) for all major protocols. Simple in-field conversion of network protocols. Multiple housing options (resin, aluminum, stainless steel). Models approved for all hazardous area applications. Control & monitoring for rotary and linear valves. Non-contact position monitoring by Hall effect sensors. Integrated pneumatic actuation control via pre-wired Falcon II solenoid valves. On-line predictive and maintenancerelated diagnostics. Eliminates wiring cost of conventionallyhardwired I/O systems. Reduces design engineering man-hours Range of drive shaft options. Visual indication Beacon available in a choice of styles and colors. Technical Data Agency approvals Area classification Non-hazardous Intrinsically safe Explosionproof Enclosure standards (IEC) All enclosures Network protocols supported PROFIBUS DP FOUNDATION Fieldbus DeviceNET AS-Interface Ver. 3.0 Enclosures 3500/8500, 3800/8800 Series 3300/8300, 3600/8600 Series 2200 Series IP66/67 2200, 3500/8500, 3800/8800 Series 2200, 3300/8300, 3600/8600 Series 2200, 3500/8500, 3800/8800 Series 2200, 3500/8500, 3800/8800 Series Engineered resin Aluminum Stainless steel www.westlockcontrols.com WESTDS-09073-EN-1302

Non-hazardous, Intrinsically Safe, Explosionproof/Flameproof - ATEX/IEC Network systems for valve automation Intellis is a family of field network control monitors which use embedded control systems to automate valves and link field I/O to the host PLC or DCS. They incorporate all the features of standard Westlock control monitors with the addition of a network I/O module. Each network monitor houses two discrete Hall effect sensors for valve position monitoring, a low power solenoid valve for actuation control and a network interface module for communication via the chosen network protocol. Monitors are available for linear and rotary applications in all area classifications. The network module Each Intellis model contains a dedicated network module (Pac) that is integrated within its enclosure. A different Pac is factory-integrated depending upon the network protocol selected. The Pacs modular design enables the simple conversion of units from one network protocol to another (with the sole exception of FOUNDATION Fieldbus ) in the field by authorized personnel, should the need arise. Integrated network modules have protective diodes and optical isolation as standard. Standard network protocols The development of standard network protocols has made it possible to integrate process control components into a network effectively. DeviceNet, AS-interface, PROFIBUS and FOUNDATION Fieldbus are now the standards for interfacing discrete devices. They are proven to be extremely reliable, simple to understand and consistently cost-effective. They integrate simply with all major PLCs and DCS systems via off-the-shelf gateway interfaces. Network modules Accessories Westlock Controls is committed to making your network design, procurement and installation experience easier. To complement our wide array of network valve monitoring and control products, we offer a variety of accessories to meet your network connectivity and power requirements. From power supplies and cables to gateways and junctions, we ve got what you need to get the job done efficiently. Peripheral interface devices Cables Power supplies Gateways Repeaters Extenders Configuration tools Software/diagnostics Junction boxes Services Westlock Controls also offers expert services for the design and installation of ASi, DeviceNet, PROFIBUS and FOUNDATION Fieldbus networks. This includes the specification of all equipment from the PLC or DCS down. Application support Engineering design Integration Start-up support Training Turnkey installations Gateway interface Active network tee (ANT) Junction box Interconnects Page 2

Non-hazardous, Intrinsically Safe, Explosionproof/Flameproof - ATEX/IEC Field network A field communications network comprises a specific number of network monitors interconnected by a common communications protocol. Network monitors may be placed on the field network in any physical order. Each monitor is assigned a unique address and accepts input/output signals from valve position sensors, solenoids and external devices. Communication with a PLC, DCS or host computer is accomplished by a compatible gateway interface or scanner card. PLC Automated Valve Network Monitor Gateway Interface or Scan Card Field Network Examples of equipment that can be backwired into the Junction Box: temperature sensor high level alarm low level alarm Available as... Junction Box Automated Valve Network Monitor Automated Valve Network Monitor Pressure Sensor Automated valve network monitor The network monitor for automated valves couples directly onto the pneumatic or electric actuator. Each unit can accept input/output signals from position sensors and solenoid valves while simultaneously performing on-line diagnostics. In addition, each network monitor will interact with a comprehensive range of external field devices for control or alarm purposes. External device network monitor Network monitors are available for control or monitoring of non-valve related devices including sensors, alarms, actuators, indicating lights, etc. Depending on the protocol, each stand-alone network monitor is capable of accepting up to six external devices within the primary control network. Page 3

PROFIBUS. PROFIBUS 2200, 3500/8500, 3800/8800 Series PROFIBUS (Process Field Bus) has been a standard for field bus communication in automation technology since it was first developed in 1989 PROFIBUS Physical media Maximum distance Maximum network monitors per system Maximum I/O points per system Current consumption per network monitor Interface capability Communications method Error checking Network topology Transmission speed Redundancy Valves specific diagnostics Twisted pair for communications, two wires for power. 1200 m (3960 feet) trunk 32/segment; 126/system using repeaters 1125/system 120 ma All PLCs and DCS supporting the PROFIBUS protocol Peer to peer and cyclic Master/slave CRC check Linear, prefered, drops allowed @ Baud rates below 500 kbd 9.6, 19.2, 93.75, 187.5, 500, 1500, 12000 kbps No Yes 1 PROFIBUS HOST Power Supply Specifying your network control monitor Specifying a network control monitor is a complex process as there are many variables which affect each individual application. To ensure that you receive the best possible combination for your control and monitoring requirement, please contact your local sales office for advice and guidance from one of our experts. Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. 2 125 Page 4

FOUNDATION Fieldbus FOUNDATION Fieldbus 2200, 3300/8300, 3600/8600 Series Foundation Fieldbus is an all-digital, serial two-way communications system that is an open architecture, developed and administered by the Fieldbus Foundation. FOUNDATION Fieldbus Physical media Maximum distance Maximum network monitors per system Maximum I/O points per system Current consumption per network monitor Interface capability Communications method Error checking Network topology Transmission speed Redundancy Valves specific diagnostics Two wire cable (communications and power) 1900 m (6720 feet) including spurs 6/segment if bus powered & IS; 12/segment if bus powered & non-is; 32/seg. if neither bus powered nor IS 192/system 18-24 ma IS All PLC s and DCS supporting the FF protocol Peer to peer Manchester encoding Daisy chain, trunk/drop (spurs), branching drop (spurs), point to point 31.25 kbps Yes Yes Host Input/Output Boards Specifying your network control monitor Specifying a network control monitor is a complex process as there are many variables which affect each individual application. To ensure that you receive the best possible combination for your control and monitoring requirement, please contact your local sales office for advice and guidance from one of our experts. Point to Point Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. Page 5

DeviceNet DeviceNet 2200, 3500/8500, 3800/8800 Series DeviceNet is an open device network standard based upon proven Controller Area Network (CAN) technology. DeviceNet Physical media Maximum distance Maximum network monitors per system Maximum I/O points per system Current consumption per network monitor Interface capability Communications method Error checking Network topology Transmission speed Redundancy Valves specific diagnostics Twisted pair for communications, two wires for power 1600 ft.(485 m) trunk + 512 ft. (155 m) drop 63/network; 2 networks/system 378/network plus optional 4/20mA analog I/O 756/system 45 ma + 20-25 ma/coil All PLC s and DCS with DeviceNet Interface Master/slave multimaster, peer-to-peer CRC check Zero drop, trunk/drop, daisy chain, branch 125 kbps, 250 kbps, 500 kbps No Yes PLC Specifying your network control monitor Specifying a network control monitor is a complex process as there are many variables which affect each individual application. To ensure that you receive the best possible combination for your control and monitoring requirement, please contact your local sales office for advice and guidance from one of our experts. Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. Page 6

AS-interface Ver. 3.0 AS-interface Ver. 3.0 2200, 3500/8500, 3800/8800 Series The AS-Interface protocol was developed by a consortium of major European companies. Designed specifically for use in low level automated systems, AS-i can communicate via a gateway to most higher-level bus systems such as DeviceNet, Modbus and PROFIBUS. AS-interface Ver. 3.0 Physical media Maximum distance Maximum network monitors per system Maximum I/O points per system Current consumption per network monitor Interface capability Communications method Error checking Network topology Transmission speed Redundancy Valves specific diagnostics Two wire cable (communications and power) 300 ft. (90.9m) 900 ft. (273 m) with repeater 62/network with 2.1 Master,1 network/system 434/network, 434/system (2 in/2 out) 11mA (power) - 59mA (1 in/1 out) All PLC s and DCS with ModBus, DeviceNet, PROFIBUS port Master/slave with cyclic polling Control sum, parity Trunk/drop, zero drop 167 kbps No No DOS System PLC Gateway Gateway Gateway Specifying your network control monitor Specifying a network control monitor is a complex process as there are many variables which affect each individual application. To ensure that you receive the best possible combination for your control and monitoring requirement, please contact your local sales office for advice and guidance from one of our experts. Hazardous area classification Please see our data sheet for further information on the global standards affecting the specification and installation of equipment in hazardous areas. Page 7

Aluminum and stainless steel enclosure dimensions CONDUIT ENTRY 57 [2,250] 28,6 [1,125] 8 [0,324] 176 [6,945] 157 [6,178] 134 [5,292] 67 [2,646] 32 [1,270] 62 [2,425] 123 [4,850] 28,6 [1,125] 57 [2,250] 4 HOLES TAPPED M6 x 1.0 x 9.5 DP (UK & US MONITOR) 33 [1,299] Ø 9,52 [0,375] Ø 4,85 [0,191] 3,96 A/F [0,156] 3,98 [0,157] 8,89 [0,350] 4 HOLES TAPPED M8 x 1.25 x 12.5 DP 5 ₁₆ - 18 UNC x 0.492 DP (US MONITOR) NAMUR SHAFT DETAILS 18 [0,696] 64 [2,516] L TYPE OVERRIDE 20 [0,787] 25 [0,984] 129,3 94 72 50 INLET PORT 1 19 38 152 [5,980] 152 [5,980] 98 [3,860] 75 [2,945] 91,0 [3,582] FLAT COVER 126,6 [4,984] LOW PROFILE BEACON 165,9 [6,531] STANDARD PROFILE BEACON EXHAUST PORT 3 61 83 FALCON II 5/2 WAY (THREAD TYPE CUSTOMER SPECIFIED ¼ BSP OR ¼ NPT) EXHAUST PORT 5 OUTLET PORT 4 OUTLET PORT 4 24 [0,927] 6.32 A/F [0,249] Dimensions in mm, where available imperial dimension (inches) in parentheses Technical specifications Materials of construction Enclosure Aluminum with powder coat finish Stainless steel with electropolished finish Stainless steel Co-polyester Oil impregnated bronze Shaft and hardware Beacon visual indicator Bushing Drive shaft Standard Double-D with ¼ A/F Option NAMUR standard VDI/VDE 3845 Please consult your sales office for any other requirements. Conduit entries Intellis control monitors are available with a choice of conduit entries. Please see the selection guide for standard entries. Solenoid Valves The Falcon II range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and C v to best suit your application. See the Falcon II data sheet for more information. Page 8

Engineered resin enclosure (single coil) dimensions conduit entry (optional) 14 [0,551] 6,35 [0,250] 4 HOLES WITH METAL INSERTS M8 x 1.25 x 12.5 DP 35 SQ [1,378] 17,5 [0,689] 56 [2,205] 99 [3,896] 133 [5,235] 6,35 [0,250] 28,5 [1,122] 57 SQ [2,244] 61,8 [2,434] conduit entry 130 [5,118] 65 [2,559] 67 [2,637] 75,03 [2,954] 169 [6,665] 4 HOLES WITH METAL INSERTS M6 x 1.0 x 9.5 DP 64 Ø 75 [2,945] 33 [1,299] 9,52 Ø [0,375] 8,89 [0,350] 3,98 [0,157] 19 38 72 61 50 107,3 INLET PORT 1 19 38 129,3 94 72 50 INLET PORT 1 167 [6,567] 21 [0,827] 40 [1,575] 4,85 Ø [0,191] 3.96 a/f [0,156] NAMUR SHAFT DETAILS EXHAUST OUTLET PORT 3 PORT 2 FALCON II 3/2 WAY EXHAUST PORT 5 61 83 FALCON II 5/2 WAY EXHAUST PORT 3 OUTLET PORT 2 OUTLET PORT 4 41 [1,614] OVERRIDE (OPTIONAL) CONTACT SALES OFFICE FOR DETAILS Dimensions in mm, where available imperial dimension (inches) in parentheses Technical specifications Materials of construction Enclosure Engineered resin Shaft and hardware Stainless steel Beacon visual indicator Co-polyester Bushing Nylon Drive shaft Standard Double-D with ¼ A/F Option NAMUR standard VDI/VDE 3845 Please consult your sales office for any other requirements. Conduit entries Intellis control monitors are available with a choice of conduit entries. Please see the selection guide for standard entries. Solenoid Valves The Falcon II range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and C v to best suit your application. See the Falcon II data sheet for more information. Page 9

Engineered resin enclosure (dual coil) dimensions 167 STANDARD BEACON xxx low profile BEACON conduit entry b conduit entry d 74 72 VARIOUS OUTPUT SHAFT LENGTHS, MAX LENGTH 33mm 137 174 VALVE THREAD TYPE & SIZE (¼ NPT OR BSP) conduit entry a 42 conduit entry e conduit entry c 65 41 130 typ 93.8 flat cover 34.7 11 4 HOLES FITTED WITH M8 x 1.25P x 7.5 DP MOULDED INSERTS 28.5 57.0 sq 4 HOLES FITTED WITH M6 x 1.0P x 7.5 DP MOULDED INSERTS 17.5 35.0 sq Dimensions in mm, where available imperial dimension (inches) in parentheses Technical specifications Materials of construction Enclosure Engineered resin Shaft and hardware Stainless steel Beacon visual indicator Co-polyester Bushing Nylon Drive shaft Standard Double-D with ¼ A/F Option NAMUR standard VDI/VDE 3845 Please consult your sales office for any other requirements. Conduit entries Intellis control monitors are available with a choice of conduit entries. Please see the selection guide for standard entries. Solenoid Valves The Falcon II range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and C v to best suit your application. See the Falcon II data sheet for more information. Page 10

Selection Guide Intellis 22 33 36 35 38 2200 Flameproof enclosure - available with or without solenoid valve 3300 Intrinsically safe enclosure - not available with solenoid valve 3600 Intrinsically safe enclosure - includes solenoid valve 3500 Non hazardous enclosure - not available with solenoid valve 3500 Non hazardous enclosure - includes solenoid valve Cover style 4 6 With Beacon Flat cover Position switches 9 Inbuilt Hall effect sensors Enclosure material R A S Engineered resin Aluminum 316 stainless steel Beacon type BY LY GR AR 00 Black/yellow standard height BM2-Y(std) Black/yellow low profile height Red/green standard height BM2-RG ANSI Red/white standard height BM2-R Flat cover (no beacon) Drive shaft output S N * 83 86 85 88 B1 B3 B5 B7 B9 8300 Intrinsically safe enclosure - not available with solenoid valve 8600 Intrinsically safe enclosure - includes solenoid valve 8500 Non hazardous enclosure - not available with solenoid valve 8500 Non hazardous enclosure - includes solenoid valve 90 Flow path BM3-1 90 Flow path BM3-3 90 Flow path BM3-5 180 Flow path BM3-7 180 Flow path BM3-9 Standard Westlock shaft (double-d with 6.32 mm/1/4 Flats) NAMUR std spec shaft VDI/VDE 3845 Non-standard material & build code - consult with sales office for details/other options Solenoid body material 0 A Not fitted Anodised aluminium Stolenoid coil voltage 0 C D E F Not fitted 24 V DC 24 V AC 48 V DC 48 V AC Solenoid valve specification 0 H I J K L Q * * E Non-standard build - consult with sales office for details Atainless steel G H I J 90-120 V DC 90-120 V AC 220-240 V DC 220-240 V AC Not fitted Falcon II, 3/2-way, 1.1 C v, 1/4 NPT entry - fail closed Falcon II, 3/2-way, 1.1 C v, 1/4 NPT entry - fail open Falcon II, 5/2-way, 1.1 C v, 1/4 NPT entry - fail closed Falcon II, 3/2-way, 1.1 C v, 1/4 BSP entry - fail closed Falcon II, 3/2-way, 1.1 C v, 1/4 BSP entry - fail open Falcon II, 5/2-way, 1.1 C v, 1/4 BSP entry - fail closed Non-standard build - consult with sales office for details Switch/sensor quantity 2 Two inbuilt sensors - all enclosures Conduit 2 3 4 5 Two conduit entries - all enclosures Three conduit entries - check availability with sales office Three conduit entries - check availability with sales office Four conduit entries - check availability with sales office Unit Specification GAN Fitted with Asi Netpac - std material & build UAV Fitted with DeviceNet Netpac - std material & build BGY Fitted with Foundation Fieldbus Netpac - std material & build BIP Fitted with Profibus Netpac - std material & build *** Non-standard material & build code - consult with sales office for details/other options Certification 0 A I * Non-hazardous ATEX IECEx Other options - consult with sales office for details Revision R* Internal Westlock revision number 22 4 9 A BY N 0 0 0 2 2 GAN -A R1 = Model number 2249ABYN00022GAN-AR1 Page 11

US/Canada: Saddle Brook, NJ Ph: +1 201 794 7650 Fax: +1 201 794 0913 E-mail: westlockinfo@westlockcontrols.com South America: Sao Paulo, Brazil Ph: +55 11 2588 1400 Fax: +55 11 2588 1410 E-mail: comercial@westlock.com.br Europe: Kent, England Ph: +44 1892 516277 Fax: +44 1892 707620 E-mail: sales@westlockuk.com Asia: Singapore Ph: +65 6768 5850 E-mail: sales@westlockuk.com Page 12