Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power



Similar documents
S4000TH HART. HART Communication Manual

L5354 ControlNet Communications Interface

Series Six Plus Programmable Controller

Allen-Bradley/Rockwell

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Allen-Bradley/Rockwell

Troubleshooting and Diagnostics

Analog Input Module Cat. No IFE User Manual

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

This Datasheet for the IC697CPM790. GMR Redundancy CPU, 486, 2K Triplex (voted) I/O.

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

UniPi technical documentation REV 1.1

Contents. Document information

Install the DeviceNet Module using the following procedure:

How to read this guide

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

3500/22M Transient Data Interface

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

ABB Drives. User s Manual HTL Encoder Interface FEN-31

WIRELESS INSTRUMENTATION TECHNOLOGY

Programmable Logic Controllers

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

DC/DC power modules basics

Module 1 Overview ControlLogix5000

Model 201 Wiegand Touchpad Reader Installation Guide

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Chapter 10 Troubleshooting

THERMAL MANAGEMENT SOLUTIONS

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

SenseLink TM. End-Point Controller. Addendum

User Manual. AS-Interface Programmer

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ROC Protocol Specifications Manual

IO-DIM6 6-Channel, Digital to Analogue Converters

IO-RM3 3-Stage Relay Module

210E - 210ECL ECL ECL RMS Signal Monitor. Operations Manual

4-Channel Thermometer / Datalogger

3500/62 Process Variable Monitor

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

HWg-STE HWg-STE PoE MANUAL

Keep it Simple Timing

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

MANUAL FOR RX700 LR and NR

Backup Scanner Module

AN : Using Wago CANOpen IO

Application Technique. Safety Function: Magnetic Door Switch Monitoring

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PCS0100en Persy Control Services B.V. Netherlands

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Analog Servo Drive 25A8

Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW

Installation and Operation Back-UPS 1250, 1300, 1500

Modular I/O System Analog and Digital Interface Modules

(Cat. No SI) Product Data

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Intel RAID Controller Troubleshooting Guide

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

1 Application Description Objective Goals... 3

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Applied Electronics. Commercial Dimming System UPDATE NOTICE

UPiS - Uninterruptible Power intelligent Supply

Installation guide H A. HSI hardwired system interface

Allen-Bradley/Rockwell

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

IMPORTANT PRODUCT INFORMATION

PRT3 Printer Module: ASCII Protocol Programming Instructions

G3 Series PROFIBUS DP Technical Manual

DeviceNet Scanner Module

PROFINET IO Diagnostics 1

EXTERNAL DIMENSIONS AND PARTS

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

IDDERO HOME SERVER. Quick start guide

SPL 2-00/-01 OPERATION INSTRUCTIONS

Brushless DC Motor Controller Product Specification Assembly 025F0129

Cisco Nexus 7000 Series Power Supply Modules

LADDER LOGIC/ FLOWCHART PROGRAMMING DIFFERENCES AND EXAMPLES

Perle Protocol Transparent Media Converter Modules

Kvaser Mini PCI Express User s Guide

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Programming Logic controllers

K-Type Thermocouple Sensor User s Guide

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

Transcription:

July 2010 PACSystems* RX3i Non-Isolated Analog Output Module with HART Communications, IC695ALG728 Non-Isolated Analog Output Modules, IC695ALG704, IC695ALG708 MODULE OK FIELD STATUS TB IC695ALG708 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels Non-Isolated Analog Voltage/Current Output module IC695ALG708, shown at left, and Non-Isolated Analog Voltage/Current Output module IC695ALG728 both provide eight configurable voltage or current output channels Module IC695ALG728 also features HART version 50 communications capability on each channel Analog channels can be configured for these output ranges: Current: 0 to 20mA, 4 to 20mA Voltage: +/- 10V, 0 to 10V On module IC695ALG728, channels that will use HART communications must be configured for the 4-20mA range These modules must be located in an RX3i Universal Backplane Modules IC695ALG704 and IC695ALG708 require an RX3i CPU with firmware version 30 or later Module IC695ALG728 requires an RX3i CPU with firmware version 35 or later Machine Edition Version 50 SP3 Logic Developer-PLC or later must be used for configuration These modules can be used with a Box-style (IC694TBB032), Extended Box-style (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) Terminal Block Extended terminal blocks provide the extra shroud depth needed for shielded wiring See the PACSystems RX3i System Manual, GFK-2314 revision B or later for more information about Terminal Blocks Terminal Blocks are ordered separately Isolated +24 VDC Power The module must receive 24 VDC field power from an external source The external source must be connected directly to the module s terminal block It cannot be connected via the TB1 connector on the RX3i Universal Backplane Module Features Completely software-configurable, no module jumpers to set Individually enable or disable channels Clamping and Alarm Limits Latching of Alarms Configurable output bias Rapid channel acquisition times based on filter frequency Full autocalibration On-board error-checking Configurable scaling and offsets per channel High alarm, low alarm, high-high alarm, low-low alarm detection and reporting selectable per channel Module fault reporting Configurable Hold Last State or Output Defaults Version 50 HART communications supported on module IC695ALG728 * indicates a trademark of GE Intelligent Platforms, Inc and/or its affiliates All other trademarks are the property of their respective owners

2 RX3i Non-Isolated Analog Output Module with HART Communications RX3i Non-Isolated Analog Output Modules Release History Version IC695ALG704-AA IC695ALG708-AA Firmware Upgrade Kit Revision 106 None Initial Release IC695ALG728-AA 100 None Initial Release Comments IC695ALG704-AB IC695ALG708-AB 108 44A753281-G01 44A753282-G01 IC695ALG728-AB 101 44A753283-G01 IC695ALG704-BB IC695ALG708-BB 108 44A753281-G01 44A753282-G01 IC695ALG728-BB 101 44A753283-G01 IC695ALG704-CB 108 44A753281-G01 IC695ALG708-CB 44A753282-G01 IC695ALG728-CB 101 44A753283-G01 Modified the terminal block detector switch to increase the size of the switch lever The increased size of the switch lever allows additional tolerance to assure contact with the terminal block actuator Label change only No change in functionality, performance or compatibility Upgrades This release of the module firmware replaces all previous versions The modules can be upgraded using the upgrade kits listed above Upgrade kits can be downloaded from the Support website, 0H1H2H3Hhttp://wwwge-ipcom/support Operating Notes 1 These modules have separate enable/disable options for Diagnostic Reporting and Interrupts Normally, disabling a diagnostic (such as Low/High Alarm or Over/Under range) in the configuration means that its diagnostic bit is never set However, if interrupts are enabled for a condition and that interrupt occurs, the diagnostic bit for that condition is also set during the same PLC scan The next PLC input scan always clears this interrupt status bit back to 0, because Diagnostic Reporting has it disabled 2 When using Winloader to update the firmware on module IC695ALG728, field power must be present The module s HART daughterboard is powered by field power and also has flash memory that is updated during the firmware update process Thus, to successfully update the HART daughterboard flash, field power must be present Problems Resolved in Firmware Revisions 110 and 108 When backplane power is lost and restored, the module receives its initial configuration but does NOT immediately change any output values (it holds the last state on the outputs, regardless of whether or not the module is configured for Default or Hold Last State) If field power is also lost and restored, outputs remain at their initial field powerup values of 0V/0mA After the PLC CPU goes to an Outputs Enabled mode (such as I/O Scan mode enabled), the module sends the first set of values to the outputs The Default/Hold Last State configuration options are used for CPU transitions between Outputs Disabled/Enabled and for reconfiguration, but not for initial configuration If field power is lost and restored without losing backplane power while the PLC system is in Outputs Enabled mode, outputs will start at 0v/0mA and immediately be set to (or ramped to if ramping configured) the output set values If field power is lost and restored without losing backplane power while the PLC system is in Outputs Disabled mode, outputs remain at their initial field power up values of 0V/0mA until the PLC system is placed in Outputs Enabled mode

RX3i Non-Isolated Analog Output Module with HART Communications RX3i Non-Isolated Analog Output Modules 3 Known Restrictions and Open Issues for Modules IC695ALG704 and IC695ALG708 1 Problem: The module should generate a Loss of Terminal Block fault if its terminal block is not present or not properly locked when the module is hot-inserted and power-cycled When the module is operating with its first configuration, it generates the Loss of Terminal Block fault properly However, after the module is reconfigured, it does not Recommendation: To restore operation of this fault message you can: A Clear the hardware configuration from the PLC s memory then download a new configuration B Power cycle the PLC without a battery and configure the module 2 Problem: Using a SVC_REQ 24 to reset an ALG704 or ALG708 module causes the module to lose its configuration and become inoperable Recommendations: To restore the configuration and resume module operation, reset or power cycle the module To prevent problems, use SVC_REQ 24 only as a one-shot and wait at least 5 seconds between re-execution of a SVC_REQ 24 reset request to the same module Installation in Hazardous Locations EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV 2 HAZARDOUS LOCATIONS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2; WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS

4 RX3i Non-Isolated Analog Output Module with HART Communications RX3i Non-Isolated Analog Output Modules Specifications Output Ranges Current: 0 to 20mA, 4 to 20mA Voltage: +/- 10V, 0 to 10V Backplane Power Requirements IC695ALG704, IC695ALG708: 355mA maximum at 33V IC605ALG728 with HART enabled: 380mA maximum at 33V Power Dissipation within Module Thermal Derating External +Power Supply Resolution HART Communications Output Data Format Analog Update Rate (Determined by I/O scan time, application dependent) IC695ALG704: 48 Watts maximum (Vuser=24V) IC695ALG708, IC695ALG728: 725 Watts maximum (Vuser=24V) IC695ALG704: no derating IC695ALG708, see derating curves later in this document IC695ALG728: please refer to the RX3i System Manual, GFK-2314C or later for derating information Voltage Range: 192V to 30V (24V nominal) Current required for ALG704: 150mA maximum Current required for ALG708, ALG728: 250mA maximum +/-10V: 159 bits, 0 to 10V: 149 bits, 0 to 20mA: 159 bits, 4 to 20mA : 156 bits Version 50 HART protocol supported on module IC695ALG728 Configurable as floating point IEEE 32 bit or 16-bit integer in a 32-bit field IC695ALG704 and ALG708: 8 milliseconds (approximate, all eight channels) ALG728: 16mS with HART (approximate, all eight channels) 8mS without HART (approximate, all eight channels) HART Data Scan Time (in seconds) The HART data scan can consist of up to four acquisition cycles (similar but asynchronous to the analog scan time) Each cycle includes a specific set of channels Total HART scan time depends on the number of channels enabed for HART within a specific set of channels, number of retries, enabling/disabling of slot variables, and use and configuration settings of pass-thru commands One HART Channel in Group Each HART Data channel updates every 07 second (typical) Two HART Channels in Group Each HART Data channel updates every 19 seconds (typical) Three HART Channels in Group Each HART Data channel updates every 30 seconds (typical) Four HART Channels in Group Each HART Data channel updates every 40 seconds (typical) Output Overvoltage Protection Current outputs only: -30V for 60 seconds, +30V for one hour Calibrated Accuracy Accurate to within 015% of full scale at 25 C Accurate to within 0 25% of full scale at 60 C In the presence of severe RF interference (IC 801-3, 10V/M), accuracy may be degraded to +/-1% FS Output Load Reactance Current: 10µH maximum, Voltage: 1µF maximum Maximmum Output Load Current: 850 Ohms maximum at V user = 20V Voltage: 2 Kohms minimum Output Gain Drift Voltage output: 20ppm per degree C typical Current output: 35ppm per degree C typical Output Settling Time ALG704, ALG708: Voltage or current output: 2ms, 0 to 95% ALG728: Voltage Output: 2ms, 0 to 95% Current output with HART: 70mS, 0 to 95% Current output without HART: 23ms, 0 to 95% Isolation, Field to Backplane 2550VDC for one second Maximum Compliance Voltage V user 3V (minimum) to V user (maximum)

RX3i Non-Isolated Analog Output Module with HART Communications RX3i Non-Isolated Analog Output Modules 5 Output Points vs Temperature, Current Mode Module IC695ALG704 has no thermal derating Thermal deratings for module IC695ALG708 are shown below Thermal derating information for module IC695ALG728 was not available when this document was released Please refer to the RX3i System Manual, GFK-2314C or later for, for details Vuser = 265V Vuser = 30V Ambient (Degrees C) 60 59 58 57 56 55 54 53 52 51 50 1 2 3 4 5 6 7 8 Shorted 250 Ohms 500 Ohms 850 Ohms Ambient (Degrees C) 60 59 58 57 56 55 54 53 52 51 50 1 2 3 4 5 6 7 8 Shorted 250 Ohms 500 Ohms 850 Ohms Channels Channels LEDs The Module OK LED indicates module status The Field Status LED indicates whether the external +24 VDC power supply is present and is above the minimum level and whether or not faults are present All LEDs are powered from the backplane power bus LED Module OK Field Status TB Indicates ON Green: Module OK and configured Quick Flashing Green: Module performing powerup sequence Slow Flashing Green or Amber: Module OK but not configured OFF: Module is defective or no backplane power present ON Green No faults on any enabled channel, Terminal Block is present, and field power is present ON Amber and TB Green: Terminal Block is installed, fault on at least one channel, or field power is not present ON Amber and TB Red: Terminal Block not fully removed, field power still detected OFF and TB Red: Terminal block not present and no field power is detected ON Red: Terminal block not present or not fully seated See above ON Green: Terminal block is present See above OFF: No backplane power to module

6 RX3i Non-Isolated Analog Output Module with HART Communications RX3i Non-Isolated Analog Output Modules Field Wiring The table below lists wiring connections for the Non-Isolated Analog Output Modules There are no shield terminals Terminal 4 Channel Modules 8 Channel Modules 4 Channel Modules 8 Channel Modules Terminal 1 Channel 2 Voltage Out Channel 1 Voltage Out 19 2 Channel 2 Current Out Channel 1 Current Out 20 3 (COM) (COM) 21 4 Channel 4 Voltage Out Channel 3 Voltage Out 22 5 Channel 4 Current Out Channel 3 Current Out 23 6 (COM) (COM) 24 7 No Connection Channel 6 Voltage Out No Connection Channel 5 Voltage Out 25 8 No Connection Channel 6 Current Out No Connection Channel 5 Current Out 26 9 (COM) (COM) 27 10 No Connection Channel 8 Voltage Out No Connection Channel 7 Voltage Out 28 11 No Connection Channel 8 Current Out No Connection Channel 7 Current Out 29 12 (COM) (COM) 30 13 (COM) (COM) 31 14 (COM) (COM) 32 15 (COM) (COM) 33 16 (COM) (COM) 34 17 (COM) (COM) 35 18 (COM) External + Power Supply (+24V In) 36 Each channel can be individually configured to operate as a voltage output or a current output - not both simultaneously All the common terminals are connected together internally, so any common terminal can be used for the negative lead of the external power supply Channel 2 Voltage Out 1 Current Output 19 Channel 1 Voltage Out Channel 2 Current Out Channel 4 Voltage Out Channel 4 Current Out 2 3 4 5 6 Voltage Output + V _ + I _ 20 21 22 23 24 Channel 1 Current Out Channel 3 Voltage Out Channel 3 Current Out 18 24VDC - + 36 There are no shield terminals on these modules For shielding, tie cable shields to the ground bar along the bottom of the backplane M3 tapped holes are provided in the ground bar for this purpose