1 Contactless Smartcard Reader Setup



Similar documents
Digital Keypad Use s Manual

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION MANUAL XM3 Reader

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Model 201 Wiegand Touchpad Reader Installation Guide

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Shunt lock function 3066

SYSTEM 45. C R H Electronics Design

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

SYSTEM 4C. C R H Electronics Design

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Troubleshooting and Diagnostics

AR-721U/721K/661U User s Guide

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Installation Instructions

Advanced Data Capture and Control Systems

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

PAC1 Door Access Controller

WIRELESS INTERNET TROUBLESHOOTING GUIDE Help Desk

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

VARIO PROX CARD READER INSTALLATION MANUAL

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ACCESS CONTROL SYSTEM

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

ViZion Installation Guide

Adaptability to Enhanced Security

Enterphone Solo. User/Installation Manual Part No

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Adaptability to Enhanced Security

Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's

Access Control Using Smartcard And Passcode

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Combi B Alarm box. Mounting instructions

Installation manual. Version

User Manual. Before installation and use, please read the user manual carefully.

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

QSE-CI-NWK-E Control Interface

Business/Home GSM Alarm System. Installation and User Manual

NC-12 Modbus Application

USB Port Extender Kit

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

How to setup a serial Bluetooth adapter Master Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Control Box Wiring For PRSstandard Tool

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

[FAQ] Troubleshooting Access Control Issues

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Setup guide. point to point wall plate extenders

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

Proximity Switches RS (Reed Switch)

4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

RC2200DK Demonstration Kit User Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

DK40 Datasheet & Hardware manual Version 2

IP DSLAM IDL Quick Installation Guide

ABB Drives. User s Manual HTL Encoder Interface FEN-31

PUSH BUTTON START INSTALLATION MANUAL

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Solar monitoring gateway quick start guide

EDI Distributor Control Interface Wiring and Setup Instructions

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

MANUAL FOR RX700 LR and NR

Let s Get Connected. Getting started with your Wireless Modem.

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Secure Keypads for access control

Access Control in Surveillance Station 7.0

Installation and Operating Manual

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

System Tel (Telephones) Ltd Fax Web

connecdim Gateway G1 Ethernet TCP/IP to DALI

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

PEDAL POWER. User s Manual

ACR120 Technical Specifications version 2.9 November 2005

Bluetooth Serial Adapter

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

VOICE RECORDING SYSTEM ISDN PRI / BRI

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

GLOLAB Two Wire Stepper Motor Positioner

EQUIPMENT SPECIFICATIONS

PLC training panel (Twido version)

Roadstar Installation Instruction Manual

Manual Serial PCI Cards

Single Channel Loop Detector

Transcription:

Contactless Smartcard Reader Setup This document covers the wiring and physical setup of the contactless (proximity) card (and tag) readers supported by gymmaster. There are two basic configurations Desktop and Remote Desktop is by far the simpler, the reader is connected to the PC serial port and draws it power from a USB socket. Remote involves a long cable and a separate power-supply for the reader this allows the reader to be positioned next to a doorway for example, it also provides for the reader to participate directly in access control by triggering an electric strike, latch, magnetic lock, turnstile, or sliding door to open.. Choosing the Right Lock. To use the reader for access control the door (or gate, turnstile etc) must be fitted with an electrically operable lock. There are several types of electric which can be used some examples are shown below. We suggest that you contact the person you would contact for maintenance on your door or a locksmith to assist in choosing and to fit your lock. Magnetic Lock MAGNETIC LOCKS (or maglocks) are powerful electromagnets that hold the door closed using a very strong magnetic force (typically equivalent to the weight of several hundred kilograms). When the electric current is interrupted the magnetic force stops and the door can be opened. MAG- NETIC LOCKS are suited to doors that open in one direction only. Controls for ordinary and emergency egress will need to be fitted inside the door. Electric Strike An ELECTRIC STRIKE is suitable for single doors that open with an ordinary latch handle, the outside handle should be lockable and the inside

handle should open the latch while the outside handle is locked, the ELEC- TRIC STRIKE is fitted to the frame of the doorway. When it receives a signal it lets go of the latch allowing the door to open. Electric Lockset In operation an ELECTRIC LOCKSET is much like the electric stricke, it allows unrestricted egress while oly allowing entrance when triggered by an electric signal. the difference is that it is fitted into the door itself. Electric Bolt This device is an electrically operated bolt lock, it is best suited to doors that swing both directions. as with the magnetic lock egress controls will be needed to let people out. Egress Buttons These controls are used to unlock doors from the inside 2

2 Desktop Reader: Desktop card readers are suitable for issuing cards and identifying members at a computer terminal. Desktop reader. The desktop reader has a two-colour LED indicator light and sounds a tone and indicates with the light when it recognises a card (or tag). It connects to a USB socket. PC Deskttop Card reader 3

2. 25kHz Desktop Reader The reader for 25kHz tags has a different connection method. It connects to a RS232 Serial poert to send the tag ID and to a USB socket for power. both connections are neccessary for operation. Both ends of the cable look the same but they are not interchangable. Connect the long end to the reader and both plugs on the short end to your computer. PC Deskttop Card reader 2.. USB-serial If your PC does not have a 9-pin serial port you can use a USB-to-serial adaptor cable. Connect the adaptor to the 9-pin on the reader cable and plug both USB plugs into your computer. Long end Connect Serial adaptor to reader cable Short end Plug in both USB plugs Desktop Card reader 4

3 Remote readers. remote readers can perform all the functions of desktop readers, but in addition have the ability to be connected electrically to a door, gate, or turnstile to control access.. control device wall mount card reader PC Cable upto 2m Relay unit Reader Power supply 2V DC control power supply Max. 28V DC 5

3. RS232 readers on gatekeeper control device wall mount card reader Internet router upto 2m cable USB RS232 cable external relay unit Database Server small Gatekeeper computer Ethernet switch These RFID reader do not contain a relay to activate the access control, instead an external relay unit is used which connectes to the gatekeeper using a USB to RS232 cable. Power supplies not shown. Gatekeepers will sometime be used to operate desktop readers, the readers connecto to the USB ports. Not shown: all power connections. 6

4 The Relay Unit This Illustration shows the Relay Unit (Model DC3) (open the case by carefully prying off the base) the Screw terminals A are for connection to the RFID device the screw terminals B are for the access control system socket C is for connection to an RS232 serial port socket D is for connection to a 2V DC supply to power the RFID device (2.mm inner 5.5mm outer center positive ). LED E (green) indicates that the Serial port is signaling to unlock the door LED F (red) indicates presence of the 2V supply. A B D C E F 7

4. RFID terminals These terminals are for connection to the RFID device. The Tx terminal connects to the green wire on the RFID, the Rx terminal with the white wire, the +2 with the red wire and the GND with the black. Up to m of cable can be used between the relay unit and the RFID device, we recommend CAT5 network cable for this purpose Tx Connect the green wire from the reader to here Rx Connect the white wire from the reader to here +2 Connect the red reader wire here, may also be used as an alternative DC 2V supply positive input Gnd Connect the black wire from the reader here, may also be used as alternative DC 2V supply common Using Cat-x Cable When using twisted-pair cable (eg:cat-5, or Cat-6) correct pairing of the signal wires to the reader is important, especially on long runs. Put the reader red and green wires on one pair and the reader white and black on another pair We have consistent good results with the following mapping signal RFID Cat.X Ground black green +2V red orange TXD white white-green RXD green white-orange The other conductors in the cable (not shown) can be connected to the relay terminals to opeate the lock circuit. 4.2 Relay terminals These Terminals are for signaling the access control device. We recommend loads of over 2A are not connected directly to these terminals but a second relay used as a buffer instead. NO relay normally open contact 8

COM relay common terminal NC relay normally closed contact No provision is made for an entry/exit delay for inputs other than from the card reader. If an exit delay is needed for an exit button that must be provided separately. As access control devices are often inductive switching off the curren can cause a voltage spike on the wires to the access control, this can couple to the reader s wires and destroy it. A snubber should be fitted near any switch or relay contacts, for DC circuits a silicon recitifer diode such as IN4 is well suited. 4.3 RS232 socket This socket is for connection to the computer via an RS232 cable or an RS232 to USB adapter. the RXD and TXD and ground pins of this socket are connected internally to the corresponding A terminals. the RTS pin is used to activate the relay. Thus any serial cable used must connect at-least pins 2,3,5,and 7. 4.4 2V supply Connect a 2V supply capable of atleast 3mA, the socket suits a 2.x5.5mm barrel connector with the centre positive. This socket is connected directly to the +2 and Gnd pins of connector A so that multiple units can be powered from a single 2V supply by connecting the 2+ and Gnd of the additional unit(s) to the +2 and Gnd of the first (allow an additional 3mA more power supply capacity for each additional connected unit) 4.5 Green LED This lights when the RTS signal on socket C is asserted, indicating a signal that should open the door, 4.6 Red LED This is the power LED. It indicates presence of power 9

5 The RFID reader The RFID reader has several wires but only 4 of them are used by our system the unused wires should be insulated from one another. The 4 wires that are used are coloured red, black, white, and green. 5. RFID Readers with screw terminals Some readers have screw terminals instead of wires. use the following key to interpret the diagrams. All other terminals are not used. Terminal wire colour VCC red GND black TXD white RXD green 5.2 Three-wire RFID readers Some readers use only three wires, If you are supplied readers with only three wires, connect the red, and black wires as illustrated, and connect the third wire as the white wire is shown in the illustrations. We recommend that you install the green wire shown in the diagrams but leave it unconnected at the reader end, as it may be needed for future RFID readers. 6 Sample Wiring diagrams These wiring diagrams are intended as examples of how he relay unit and RFID device may be installed. If you are using CAT-5 cable to the reader be sure to followin the pairing isntructions at 4. on page 8

6. Fail Secure For a fail-secure access control device like electric strike, where there is a mechanical exit method. If they are the fail safe type which requires electric current to unlock and locks when not powered wire the circuit as follows. Reader Control eg. electric strike control supply Diode (Snubber) Relay Unit

6.. Fail secure with emergency exit For a fail-secure access control device like electric strike or electric bolt where there is a need for an electric door release control on the inside of the door wire the circuit as follows. Emergency exit switch Reader NC Com No Control eg. electric bolt Exit Delay switch NC Com No + 2V control supply Diode (Snubber) Relay Unit 2

6.2 Fail safe For a fail-safe access control device like electric strike, or electric latch. If it is the fail safe type which requires electric current to lock and unlocks when not powered wire the circuit is as follows. Reader Control eg. magnetic lock control supply Diode (Snubber) Relay Unit 3

6.2. Fail safe with emergency exit For a fail-safe access control device like magnetic lock or electric bolt. If they are the fail safe type which requires electric current to lock and unlocks when not powered and an exit button is required the circuit is as follows. Reader Emergency exit switch NC Com No Diode (Snubber) Control eg. magnetic lock Exit Delay switch NC Com No + 2V control supply Diode (Snubber) Relay Unit 4

7 Combinations of relay units there are several useful ways in which multiple relay unit can be interconnected. in these illustrations the connections to the reader and PC are not shown. 7. multi-relay units for sites with several RFID stations a multiple controller unit may be supplied consisting of several relay units, with a single DC input socket. A power supply capable of at least 3mA multiplied by the number of RFID units should be used. Alternatively multiple single units may be interconnected to share a single 2V supply. Link to other unit(s) single 2V Supply Alternatively the powersupply can be connected to the screw terminals instead of to the socket 7.2 Shared lock power supply If the access control operates from 2V it can be powered from the same supply as the reader as long as the 2V supply for the reader is powerful enough to operate both devices at the same time. In this case to connect access control (+) to +2V supply access control (-) to GND Shared power, fail secure Shared power, fail safe Note: the brown wire only used for fail safe with exit button 5

7.3 bi-directional When you want to have readers both sides of the door you need to combine the relay contacts. These wiring patterns can be used in combination with the powersupply shairing wiring pattern above. the wiring pattern you shoukd use depends on which relay contacts are being used. 7.3. Normally Open contacts In arrangements where the normally open (NO) contacts are used wire the relays in parallel Change ths: To this: 7.3.2 normally closed contacts In arrangements where the normally closed (NC) contacts are used wire the relays in series Change ths: To this: 6

8 Prox rex. Prox-Rex is a New Zealand made exit button, emergency exit button and timer unit that can be used in fail-safe settings. the following is one way to set it up. Control eg. magnetic lock Diode (Snubber) Reader control supply Diode (Snubber) 7

9 Troubleshooting 9. Relay unit 9.. Red Led not lit. The red LED on the control indicates that the power supply to the reader is operating, it should normally be Lit. if it is not lit: disconnect the powersupply and check that it the powersupply works. eg: unplug the powersupply from the socket on the relay unit the powersupplies we send have a red LED that should light up if it is wirking if the powersupply is not working check that it is plugged into a working outlet having confirmed that the powersupply works re-connect it to the relay unit. eg: plug it back in if the RED led on the relay unit comes on, it is working. If nothing happens the cable from the powersupply to the relay unit is faulty, or the plug has incorrect polarity the polarity of the plug can be changed by removing the tip and rotating it 8 degrees about its long axis. The arrow should indicate this symbol: If the LED on the powersupply goes out there is an electrical fault, it could be one of. wiring fault (short circuit) somewhere on the card reader cable. 2. something on the card reader cable is consuming too much power. 3. a bad powersupply 4. a faulty relay unit (unlikely) 9..2 Green LED won t extinguish, and door remiains unlocked confirm that gymmaster is seeing the tags the green led should only light when the door should unlock, if it is on permanently there is some sort of software problem, check that the cardsentry for the door is using one of the access control reader types eg: TE25, ASCII Control (25kHz tags), or TE5 (3.56MHz Mifare tags) 8

check that some other software is not usiong the serial port check that the door is not set to open/unlocked in gymmaster. 9..3 Green LED wont light and door won t unlock check that the RFID tags are being read correctly check that the reader is funtioning correctly and that gymmaster is interpreting the codes correctly check that all plugs are connected correctly check that the cable between the serial port and the relay unit connects pin 7 check that the door is not set to locked and that the current time is within the facility s open hours. Any cable used to connect the relay unit to a serial port must connect at-least RXD,TXD,SG, and RTS (pins 2,3,5, and 7) 9.2 Power supply The power suply must provide 2V DC, It is recommended that an uninteruptable powersupply is used to back it up. 9.3 Interactiion with gymmaster 9.3. RFID tags not seen by gymmaster if the reader is connecte to your gymmaster computer check that cardsentry is installed and configured correctly,. gymmaster settings 2. gymmaster preferences 3. card readers 4. cardreader hardware setup 5. restart gymmaster after making changes. 9.3.2 Rfid tags interpreted incorrectly check that the correct type of RFID reader is selected. for 25Khz EM4 tags ASCII Control is recommended except where there are existing cards using the TE25 system, if the card numbers come out different try swapping the new reader to the other system. 9

Revision history. Jan 2. Original. 2. Jul 2. Corrected wiring for fail secure exit button, updated relay unit graphic. 3. Jun 2. relay unit model DC3 released. graphics updated, more detail added. 4. Oct 2. Combinations of relay units, indicate RFID wiring colours on DC3 detail 5. Mar 22. On the importance of snubbers. 6. Nov 22. serial port pin 7 essential. 7. July 23 rename control unit to relay unit 8. Aug 23 clean up text, reorder document sections. 9. june 25 changed cyan wire to brown, fail safe without exit button, diagrams for share power with lock. RFID readers with 3 wires or with screw terminals. Copyright Copyright 2-25 Treshna Enterprises all rights reserved. 2