FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Similar documents
Electrical Resonance

Inductors in AC Circuits

11: AUDIO AMPLIFIER I. INTRODUCTION

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Lab 1: The Digital Oscilloscope

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Lab #9: AC Steady State Analysis

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Electronic Circuits Spring 2007

INTERFERENCE OF SOUND WAVES

RLC Series Resonance

Annex: VISIR Remote Laboratory

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Kit Watt Audio Amplifier

= V peak 2 = 0.707V peak

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Using an Oscilloscope

Lab 3: Introduction to Data Acquisition Cards

Lab 3 - DC Circuits and Ohm s Law

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Chapter 19 Operational Amplifiers

Lab E1: Introduction to Circuits

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide

13. Diode Rectifiers, Filters, and Power Supplies

Lock - in Amplifier and Applications

The basic set up for your K2 to run PSK31 By Glenn Maclean WA7SPY

MATERIALS. Multisim screen shots sent to TA.

CX Zoner Installation & User Guide

The Sonometer The Resonant String and Timbre Change after plucking

Oscilloscope, Function Generator, and Voltage Division

Electronic WorkBench tutorial

ECEN 1400, Introduction to Analog and Digital Electronics

THE ELEMENT SUPPORT OPERATING INSTRUCTIONS AMP+DACS ONLINE BY PHONE BY MAIL

Reading: HH Sections , (pgs , )

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Lab 4 - Data Acquisition

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

ARRL Morse Code Oscillator, How It Works By: Mark Spencer, WA8SME

Electromagnetic Induction: Faraday's Law

Lab 3 Rectifier Circuits

Lab Exercise 1: Acoustic Waves

Sound Pressure Measurement

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

SERIES-PARALLEL DC CIRCUITS

K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

Lab 1: Introduction to PSpice

Dash 18X / Dash 18 Data Acquisition Recorder

Reading assignment: All students should read the Appendix about using oscilloscopes.

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Frequency Response of Filters

Lab 5 Operational Amplifiers

Manual for the sound card oscilloscope V1.24 C. Zeitnitz english translation by P. van Gemmeren and K. Grady

Measuring Impedance and Frequency Response of Guitar Pickups

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

RGB for ZX Spectrum 128, +2, +2A, +3

The RIDZ 8x2 Audio Switcher

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

F(t) Forssell Technologies Inc

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Hands On ECG. Sean Hubber and Crystal Lu

Scaling and Biasing Analog Signals

Pulse Width Modulation (PWM) LED Dimmer Circuit. Using a 555 Timer Chip

RC Circuits and The Oscilloscope Physics Lab X

Building the AMP Amplifier

Dash 8Xe / Dash 8X Data Acquisition Recorder

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

What you will do. Build a 3-band equalizer. Connect to a music source (mp3 player) Low pass filter High pass filter Band pass filter

Electricity & Electronics 5: Alternating Current and Voltage

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

LAB 12: ACTIVE FILTERS

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

Interactive Logging with FlukeView Forms

Current Monitoring Kit

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

Experiment # (4) AM Demodulator

Timing Errors and Jitter

MODEL 2202IQ (1991-MSRP $549.00)

6.101 Final Project Proposal Class G Audio Amplifier. Mark Spatz

Operational Amplifier - IC 741

SYSTEM 4C. C R H Electronics Design

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Laboratory 4: Feedback and Compensation

WOO AUDIO WA3. Stereo Headphone Amplifier. Single-Ended OTL, Class A Vacuum Tube Headphone & Pre Amplifier. Owner s Manual

Trigonometric functions and sound

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Parts of a Computer. Preparation. Objectives. Standards. Materials Micron Technology Foundation, Inc. All Rights Reserved

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Features, Benefits, and Operation

Step Response of RC Circuits

Routinely DIYers opt to make themselves a passive preamp - just an input selector and a volume control.

Prepared by: Paul Lee ON Semiconductor

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

HIGH PERFORMANCE CAR AUDIO MODEL:CR-82 8 CHANNEL ELECTRONIC CROSSOVER NETWORK SYSTEM.

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

Transcription:

2014 Amplifier - 1 FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER The objectives of this experiment are: To understand the concept of HI-FI audio equipment To generate a frequency response curve for an audio amplifier To thoroughly bore you APPARATUS: Audio Amplifier (Circuit Chip), Computer with FFTScope software, Speaker, Power supply, Interconnecting Cables A good high fidelity amplifier will have frequency specifications flat to within ± 1 db from 20 Hz to 20 khz at a specified power. Under the best conditions the human ear can barely detect a 1 db change in sound level, and only a very young child can hear frequencies as high as 20 khz. So an amplifier this good probably won't introduce any audible distortion of its own into your sound system. On the other hand, a 1 db change in amplifier output voltage corresponds to about a 12% change in voltage

2014 Amplifier - 2 which is easily measured with an oscilloscope. In this experiment you will study the frequency response of an inexpensive audio amplifier and obtain a response curve. The equipment should already be set up and all connections should be in place. The general premise of the set-up is that an AC comes into the Drive side of the wooden board. The jack labeled Gnd is just a ground to prevent damage to the equipment or the people handling it. The Signal input splits with one branch connecting to the amplifier chip, and the other to the jack labeled right on the Read side of the wooden board. Therefore the input signal is being fed back into the computer to be read directly, and is also going through the amplifier. After the current passes through the chip and gets amplified, it passes through the speaker which emits sound. The wiring from the speaker then continues to the Read side and connects to the Gnd and left jacks, returning to the PC speaker to be read as output voltage by the FFTScope software. The diagram below indicates the connections between the various components of the system.

2014 Amplifier - 3 The amplifier chip itself is kit 48 from DIY Electronics. It is made up of resistors, capacitors, transistors, and other electronic components (see kitsrus.com for details if you are interested). The chip is pictured below. PROCEDURE A. CAUTION: Initially, keep the volume of the sound very low by setting both the PC speaker volume and potentiometer (metal knob on chip) at a low level. Place your hand near the chip (but do not touch) periodically to determine whether the chip is becoming too hot. If so, turn down the PC speaker volume and/or blow on the chip to cool it. Turn on the power supply by pressing the green on/off button and, using the Voltage Fine knob, set it to approximately 18 V. Only use the Coarse knob if the Fine knob doesn t bring you close enough to 18 V. The chip should say 18 V DC which indicates that this is the appropriate voltage. Switch the black ON/OFF switch on the circuit board to ON.

2014 Amplifier - 4 Open the FFTScope software in the Lab Apps folder on the desktop. Set the Signal generator to Sine. Select Oscilloscope dual channels on the bottom. There should be two traces visible now, a red one and a blue one. Autoscale and click-and-drag if necessary. The units of the red trace are on the left and those of the blue trace on the right. The units are in mv, but the values may not be meaningful in anything more than a relative way (i.e. you can compare the traces, and the values at different driving frequencies, but the numbers may not give the actual voltage due to absence of calibration). The L and R values at bottom will give the values at the position of the cursor. The L trace should be red and the R trace blue. The speaker (hardware) and Mac (software) volume controls will control the voltage input to the amplifier, whereas the potentiometer knob will control the voltage output by the amplifier. Both traces will respond to adjusting the speaker/mac levels, while only the L (red) trace will respond to adjusting the potentiometer level. Remember to keep the volume low as you experiment with the set-up. B. Usually manufacturers of audio equipment give the frequency response of an amplifier in db relative to its response at a particular frequency. Use 1 khz as the reference frequency. With the signal generator on Sine set the Frequency to 1 khz and check that the input level (trace R, blue) is 20 mv. Watch the L trace (red) which displays the amplifier output voltage and slowly increase the amplifier volume until the output level reaches about 100 mv. The peak-to-peak amplitude value at the bottom data box will tell you twice the amplitude of the left trace, succeeded by the right trace. If the numbers fluctuate too rapidly, you may stop data collection by pressing the space bar; however, you ll have C. Measure the amplifier output voltage (trace L, red) at each of the frequencies from 20 to 16,000 Hz as indicated in the table below. Since the input voltage (i.e. the voltage provided by the function generator) can drop at higher frequencies, before recording your data check that the input voltage (trace R, blue) is within a few mv of 20. Readjust the speaker/mac volume level if necessary to insure a 20 mv input signal. Watch the red trace and note the output level. Record the input and output voltage in columns 2 and 3 in the table below using view peak-to-peak amplitude as above. Be careful not to change the potentiometer control while recording your data. If you accidentally change it, start over. D. To calculate the response in db, use the equation: Response (db) = 20 log [V output / 0.1] Use the data in column 3 for the Output and record your Response in column 4. This procedure converts the voltage output to a decibel response relative to 0 db at 1 khz. This is (as noted above) because manufacturers give the frequency response of an amplifier in db relative to its response at a particular frequency. We decided to use 1 khz as our reference frequency, where the amplifier's output voltage was adjusted to give 0.1 V. You can easily see that for this frequency 20 log[0.1/0.1] = 20 log[1] = 0 = Response (db).

2014 Amplifier - 5 E. Make a plot of the Response (db) versus Frequency (Hz) with Logger Pro or Graphical Analysis software. Connect your data with a smooth hand drawn or computer generated curve. Include your data table and clearly label your graph. F. Now to do things the simple way (which is how it is done in real life). Select the fft on left channel option. Set the Signal generator to White noise, and also select the FFT averaging on option by clicking its box. You can turn averaging off when the curves are smooth (i.e. noise has died out) by unchecking the box. The red trace will give you the frequency response curve which you meticulously assembled above (here with hardly any effort). Go to File >Print to print out your trace. FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

2014 Amplifier - 6 LAB REPORT FORM NAME: DATE: PARTNERS: Frequency Input Output Response (Hz) (V) (V) (db) 20 50 100 500 1 k 5 k 10 k 16 k Please attach graph for part E. and screen shot for part F. Question 1: What is the range of frequencies (highest and lowest) for which the amplifier's response is constant within 3 db? This is called the 3 db frequency response of the amplifier and is often quoted by the manufacturer. Question 2: Does this amplifier qualify as high fidelity equipment? Explain.

2014 Amplifier - 7 Question 3: Within the range of frequencies typically encountered in music is the frequency response flat? Is this desirable for audio experience? How would the response observed affect the aural effect of recorded music?