WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels



Similar documents
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels

Your Simple Guide to Battery. Replacement. Customer Care:

Battery Replacement Instructions First Alert 148 & 168, Vista- 10, Vista- 20, DSC 1555 and DSC 1616 Residential Control Panels. Battery Safety Warning

GE Wireless Devices Battery Replacement

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

WIRELESS HOME ALARM SYSTEM (WHA1)

Wireless Home Security Alarm System AM 500

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Wireless Indoor/ Outdoor Thermometer

Total Protection Alarm System

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Quick Installation Guide LCD GSM ALARM SYSTEM LH

CS848E Receiver for 868GEN2 Devices Installation Sheet

User Guide. Model: MAS-WA-SYS

GE Concord 4 Quick User Guide

PiSector Land Line Auto Dial Professional Wireless Alarm System

SECURITY SYSTEM MANUAL

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

System User s Manual

2.1 Battery Installation Powering On & Off Pairing Mount Installation 5

Ademco Vista-20P/First Alert FA-168C Basic Commands

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Model: Manual DC: WIRELESS COLOR FORECAST STATION

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

INSTALLATION AND OPERATION MANUAL

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Wireless Alarm system s manual

Changes or modifications not expressly approved by Interlogix, Inc. can void the user s authority to operate the equipment.

PA500II Enterprise Mobile Computer

Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user s authority to operate the equipment.

1161/1162 Residential Wireless Detectors

Important Safety Instructions

Passive Infrared Sensor Alarm

MELALEUCA SECURITY QUICK START GUIDE PROTECTION YOU CAN COUNT ON FROM PEOPLE YOU CAN TRUST

GE Simon XT Quick User Guide

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

BODY-12, Door Handle - Removal, Installation, and Adjustment

Memory Modules User Guide

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Emergency Dialer DIAL-ALERT MODEL: AD

LED Security Spotlight User Manual

5800 Wireless Series INFORMATION FOR DEALERS: WIRELESS SOLUTIONS FOR EVERY HOME OR BUSINESS. Quicker Installs... Higher Profits

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Digital Life User Guide

Upgrading and Servicing Guide

NOTE: The home screen always displays the day and month, time, & P1 (Partition 1)

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

5800 Temperature Sensor Cable Assembly

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Front Panel Board Cable Replacement Instructions

Drayton Digistat +2RF/+3RF

Quick Setup Guide DIRECTV Cellular System

Replacing the Gateway M320 Keyboard

Using Your GEM-P400 Security System

2013 VTech Printed in China US

GSM ALARM SYSTEM USER MANUAL

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

PAR Tablet 10 Quick Start Guide

Residential & Commercial Alarm Systems by Gross Security, LLC

Service Guide. Gateway M275

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Alarm Security Kit - NVR

EasyNote TJ Series. Disassembly Manual

PiSector GSM Cellular Wireless Alarm System

HWS100 Wireless Home Security System

HILLS Series LED Code Pad User Manual

User Manual CN2HK LIMITED. Complete Wireless Home Alarm Security System (CK-8806) ENG. Please read this manual before operating this product.

Treasure Cove Metal Detector

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

UPGRADING AND SERVICING GUIDE

KEYPAD LOCK RETROFIT KIT

Model 70A00-1. GSM Cellular Communications Center

Home Security Alarm System

WIRELESS WATER LEAK DETECTOR

Service. FCC Notices. Certification Number: B4Z-USA AL-T

Control Center User s Manual

Wireless Alarm System

PK5500 v1.1 Installation Instructions

Triac Printed Circuit Board Replacement

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

SEC-ALARM200 WIRELESS ALARM SYSTEM

Hills wireless security alarm DIY range

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Owner s Manual & Safety Instructions

Inspiron 15. Service Manual Series

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

ADEMCO LYNXR-I Security Systems

ALARM SYSTEM INSTALLATION GUIDE

Total Protection Alarm System

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Owner s Manual & Safety Instructions

Transcription:

www.adt.ca WIRELESS SENSOR For Safewatch Residential Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential security system may be installed with wireless sensors, such as door and window contacts, motion detectors, glassbreak detectors, smoke/heat detectors and carbon monoxide detectors, that are self powered by internal batteries. The batteries inside these wireless sensors, much like a car s battery, must be replaced from time to time due to age and usage. The battery in a wireless sensor needs to be replaced when the keypad displays a BAT or LO BAT message along with the sensor s point or zone. In most cases you can replace the battery in these wireless sensors yourself, typically saving you time and money. The process requires that the wireless sensor be identified and the removal and replacement of the battery (or batteries) according the Battery Replacement Instructions shown below. Please read these instructions carefully, including the Battery Safety Warning instructions below. Battery Safety Warning This section on Battery Safety should be read in its entirety and its contents understood before handling or using a non rechargeable metallic lithium battery. MSDS (Material Safety Data Sheets) are available upon request. Due to the potential energy stored in a non rechargeable metallic lithium battery, improper handling or use of the battery or failure to observe the precautions listed in this document may result in bodily injury caused by electrolyte leakage, heat generation or explosion. USE ELECTRICALLY INSULATED TOOLS. Use of un insulated tools may cause a short circuit and the heat or sparks generated by the short circuit can result in burns, damage to the battery or sensor, or an explosion. Metallic tools may be insulated using vinyl or electrician s tape. When unpacking the battery, make sure to handle it gently. Check that the battery is free from dents or leakage. Excessive force should not be used to free a battery lodged inside the sensor and the battery should not be forced into the sensor housing. These may cause an internal short circuit in the battery. If at any time you feel uncertain that you can follow these instructions or want to have the battery replaced by an ADT service technician, contact the ADT Customer Care Department at 1-800-ADT-ASAP and schedule a service appointment. In most cases, ADT s standard service charge will apply. Requesting a Replacement Battery If you choose to replace the battery yourself, contact ADT at 1-800-ADT-ASAP to have replacement CR123A batteries sent to you or you can purchase them at a local battery supply store. 1

Battery Replacement Steps Step Action 1 Determine which wireless sensor is causing the LO BAT or BAT message on the keypad display by the description or point/zone number of the sensor that is shown on the keypad s display. 2 After you have located the wireless sensor, identify the model number of the sensor by comparing the sensor with the photographs shown below in the Table of Contents on Page 3. If you cannot identify the model number of the sensor, call 1 800 ADT ASAP to schedule a service call. If you can identify the model number of the sensor proceed to Step 3. 3 If after reviewing the specific Battery Replacement Instructions given below for that model of sensor, and the Battery Safety Warning at the beginning of these instructions, you then choose to replace the battery yourself, contact ADT at 1 800 ADT ASAP to have a replacement battery sent to you or you can purchase a CR123A battery at a local battery supply store. 4 Upon receipt of the battery you can proceed to replace the battery: Ensure you have your Personal Identification Code (PIC) and then call the ADT Customer Care Department at 1 800 ADT ASAP to request that your security system be placed on test. Caution: Be sure to read the Battery Safety Warning at the beginning of these instructions before changing the battery. With the system on test replace the battery, or batteries, following the steps in the specific Battery Replacement Instructions shown below for that model of sensor. Then proceed to Step 5. 5 Go to your alarm system keypad to make sure that it no longer displays a BAT or LO BATTERY message. Does your security system display either one of these messages? If no, go to step 6. If either the BAT or LO BATTERY message is still displayed please call ADT at 1 800 ADT ASAP to schedule a service call for a service technician to inspect your security system. 6 Test your security system to make sure it is working properly. Follow the instructions in the control panels User s Guide in the Testing the System section. User s Guides are available for downloading at www.adt.ca Did you experience any issues during the system test? If no, go to step 7. If yes, please call ADT at 1 800 ADT ASAP to schedule a service call for a service technician to inspect your security system. Note: Testing of your security system should be conducted each week, and this step tests overall system functionality, and is not specific to low battery signals. 7 Ensure you have your Personal Identification Code (PIC) and then call the ADT Customer Care Department at 1 800 ADT ASAP to request that your security system be placed removed from test. 8 Please dispose of the battery appropriately. ADT wants to make customers for life and believes in sustainability and protecting the environment. In pursuit of these goals, ADT is constantly looking for ways to decrease our impact on the environment. We encourage you to do your part and properly recycle the old non rechargeable lithium battery being replaced in your alarm system. For information regarding recycling your old battery, please go to www.call2recycle.org TABLE OF CONTENTS 2

LIFE SAFETY DEVICES 5800CO Carbon Monoxide (CO) Detector with Built In Wireless Transmitter.. Page 5 5808 Photoelectronic Smoke/Heat Detector with Built in Wireless Transmitter..Page 6 5808LST Photoelectronic Smoke/Heat Detector with Built in Wireless Transmitter..Page 6 5808W3 / W3 ADT Photoelectronic Smoke/Temperature Detector with Built in Wireless Transmitter...Page 7 5809 Rate Of Rise Heat Detector with Built In Wireless Transmitter.......Page 8 DOOR, WINDOW & TEMPERATURE SENSORS 5816 Door/Window Transmitter Page 9 5816WMBR Door /Window Transmitter (Brown)....Page 9 5816WMWH Door /Window Transmitter (White)...Page 9 5816MN Miniature Door Window Transmitter....Page 10 5817 Multi Point Universal Transmitter Page 11 5817CB Commercial Burglary Transmitter.....Page 11 5819 Shock Processor Transmitter... Page 12 5819BRS/5819WHS Shock Processor Transmitter....Page 12 TABLE OF CONTENTS (Cont d) 3

GLASSBREAK DETECTOR 5853 Glassbreak Detector with Built In Wireless Transmitter. Page 13 MOTION DETECTORS 5800PIR Indoor PIR Motion Detector with Built In Wireless Transmitter..Page 14 5800PIR RES Residential PIR Motion Detector with Built In Wireless Transmitter...Page 14 5890 PIR Motion Detector with Built In Wireless Transmitter.......Page 15 5890PI PIR Motion Detector with Pet Immunity with Built In Wireless Transmitter....Page 15 4

5800CO Carbon Monoxide (CO) Detector with Built In Wireless Transmitter Battery: CR123A 3-volt Lithium 1. Put your alarm system into TEST mode (Typically by entering your user code plus the number 5 2. Remove the detector from its mounting base by twisting the detector counterclockwise. Remove the battery and dispose of properly. 3. Wait at least 30 seconds before installing the new battery. 4. Install a new CR123A Lithium battery in the battery compartment. Follow the polarity diagram inside the compartment. 5. Reinstall the detector onto the mounting base by turning the detector clockwise. 6. The green LED should blink about once every 10 seconds to indicate normal operation. If the battery is not installed correctly, the detector will not operate and the battery may be damaged. If the detector does not appear to be sending a signal during any of the tests, check for correct battery installation and for a fully charged battery. 5

5808 Photoelectronic Smoke/Heat Detector with Built in Wireless Transmitter 5808LST Photoelectronic Smoke/Heat Detector with Built in Wireless Transmitter The smoke detector checks for low batteries at least every 60 minutes. If a low battery is detected, the transmitter sends a low battery message to the control panel, which beeps and displays the detector's ID. This condition will exist for a minimum of seven days, and then the detector's horn will "chirp" about every 40 seconds. The batteries should be replaced BEFORE the chirps begin. BE SURE TO REPLACE BOTH BATTERIES WITH FRESH ONES. Battery: CR123A 3-volt Lithium (two required) 2. Remove the smoke detector body from its mounting base by turning the detector body counterclockwise approximately ½ -inch. 3. Remove the battery, and dispose properly. Wait at least 30 seconds before installing a new battery. 4. Install new CR123A Lithium batteries in the battery compartment. Follow the polarity diagram inside the compartment. 5. Replace the smoke detector by aligning the ridge on the body with the raised arrow on the base and turning the detector clockwise approximately ½ -inch. 6. Press the test button. Hold until touchpad activates (about 30 seconds), then release. 6

5808W3 / W3 ADT Photoelectronic Smoke/Temperature Detector with Built in Wireless Transmitter The detector checks for a low battery at least every 65 minutes. If a low battery is detected, the transmitter sends a low battery message to the control panel, which beeps and displays the detector s zone number. In addition, the red LED of the will blink every 45 seconds and the test switch will be disabled. This condition will exist for a minimum of 7 days, and then the detector s horn will chirp about every 45 seconds. Pressing the test switch during this time will silence the chirps for 12 hours. The battery should be replaced BEFORE the chirps begin. Be sure to replace the battery with a fresh one. Battery: CR123A 3-volt Lithium 2. Remove the smoke detector body from its mounting base by turning the detector body counterclockwise approximately ½ -inch. 3. Remove the battery, and dispose properly. Wait at least 30 seconds before installing a new battery. 4. Install new CR123A Lithium batteries in the battery compartment. Follow the polarity diagram inside the compartment. 5. Replace the smoke detector by aligning the ridge on the body with the raised arrow on the base and turning the detector clockwise approximately ½ -inch. 6. Press the test button. Hold until touchpad activates (about 30 seconds), then release. 7

5809 Rate Of Rise Heat Detector with Built In Wireless Transmitter Battery: CR123A 3-Volt Lithium 2. Remove the heat detector from its base by turning the detector body counterclockwise approximately 3/4 inch. 3. Remove the battery, and dispose properly. Wait at least 30 seconds before installing a new battery. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Make sure the battery is seated firmly. 5. Replace the heat detector back onto its base by aligning the exposed corner of the C board with the tamper switch on the base and turning the detector clockwise approximately ¾-inch. 6. Exit the alarm system TEST mode by entering your user code plus the number 1 (OFF). Enter your user code plus the number 1 (OFF) again. 7. The low battery message should clear within 90 minutes. 8

5816 Door/Window Transmitter 5816WMBR Door/Window Transmitter (Brown) 5816WMWH Door/Window Transmitter (White) Battery: Battery: CR123A 3-volt Lithium 2. Remove the transmitter s cover using the finger latch (some older models may require inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit on the right side closest to the cover s decorative ribs and twisting). 3. Remove existing battery from the transmitter, carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Activate the transmitter by opening and shutting the door or window. The touchpad will beep 3 times confirming reception. 9

5816MN Miniature Door Window Transmitter Battery: CR123A 2. Remove the transmitter s cover by inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit on the right side closest to the cover s decorative ribs and twisting. 3. Remove existing battery from the transmitter, carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Activate the transmitter by opening and shutting the door or window. The touchpad will beep 3 times confirming reception. 10

5817 Multi Point Universal Transmitter 5817CB Commercial Burglary Transmitter Battery: CR123A 3-Volt Lithium 2. Remove the transmitter s cover by inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit on the right side closest to the cover s decorative ribs and twisting. 3. Remove existing battery from the transmitter, carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Activate the transmitter by opening and shutting the door or window. The touchpad will beep 3 times confirming reception. 11

5819 Shock Processor Transmitter 5819BRS/5819WHS Shock Processor Transmitter Battery: CR123A 3-Volt Lithium 2. Remove the transmitter s cover by inserting the flat blade of a small screwdriver into the pry-off slot at the bottom end of the unit on the right side closest to the cover s decorative ribs and twisting. 3. Remove existing battery from the transmitter, carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Activate the transmitter by opening and shutting the door or window. The touchpad will beep 3 times confirming reception. 12

5853 Glassbreak Detector with Built In Wireless Transmitter Battery: CR123A 3-volt Lithium (2 required) NOTE: In some cases a cover screw may have been use. Prior to opening the case, remove this screw is present. 2. Remove the transmitter s cover by inserting the flat blade of a small screwdriver into the pry-off slot at one end of the unit (see Figure for location), and slightly twisting the blade until the cover disengages. IMPORTANT: DO NOT REMOVE the circuit board from the back case plastic 3. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 4. To replace the cover, engage the hooks along one edge and snap shut. 5. Exit the alarm system TEST mode by entering your user code plus the number 1 (OFF). Enter your 13

5800PIR Indoor PIR Motion Detector with Built In Wireless Transmitter 5800PIR RES Residential PIR Motion Detector with Built In Wireless Transmitter Battery: CR123A 3-volt Lithium 2. Open the detector by pressing on finger tab as shown in the Figure. 3. Remove existing battery by carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). Take care not to bend the antenna. 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Allow the motion detector to re-set by leaving the room for at least 4 minutes; then walk past the detector to activate it. The touchpad will beep 3 times confirming reception. 14

5890 PIR Motion Detector/Transmitter with Built In Wireless Transmitter 5890PI PIR Motion Detector/Transmitter with Pet Immunity with Built In Wireless Transmitter Battery: CR123A 3-volt Lithium (2 required) 2. Remove front cover by inserting a large screwdriver blade (or small coin) in groove between cover and base at the location shown in Figure 1; rotate blade to override snap fit then lift cover off. 3. Remove existing battery by carefully lifting it out with a small screwdriver. 4. Observe correct polarity and install a new CR123A Lithium battery in the battery compartment (see diagram below). 5. To replace the cover, engage the hooks along one edge and snap shut. 6. Allow the motion detector to re-set by leaving the room for at least 4 minutes; then walk past the detector to activate it. The touchpad will beep 3 times confirming reception. 15