Introduction. Methods. Sample Processing



Similar documents
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Multifunctional Autosampler AOC-6000 C146-E272A

Analytical Test Method Validation Report Template

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

High Sensitivity MS Determination of Carryover in a New Autosampler Design

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

How To Test For Contamination In Large Volume Water

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082B

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Analysis of Phthalate Esters in Children's Toys Using GC-MS

A Novel Approach to Low Volume Sample Preparation

A Complete Solution for Method Linearity in HPLC and UHPLC

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Quantitative Analysis of Explosives in Surface Water Comparing Off-Line Solid Phase Extraction and Direct Injection LC/MS/MS

Overview. Purpose. Methods. Results

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Validation and Calibration. Definitions and Terminology

Oasis HLB Cartridges and 96-Well Plates

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Multi Pesticides Residue analysis in Ayurvedic cough Syrup by GCMS/MS using QuEChERS extraction method

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Guidance for Industry

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

一 Development of microchip integrated with electrochemical sensor in conjunction with indium tin oxide electrode

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

ProteinPilot Report for ProteinPilot Software

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

The Theory of HPLC. Gradient HPLC

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

D-Facts. Vitamin D Competitive Evaluation

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

High-Throughput 3-D Chromatography Through Ion Exchange SPE

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

ApplicationNOTE Introduction

CORESTA RECOMMENDED METHOD N 72

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

Transcription:

PO-CON1656 High-sensitivity, high-throughput quantitation of catecholamines and metanephrine in plasma by automated WCX-SP coupled to LC/MS/MS for clinical research ASMS 2016 MP-080 Ichiro HIRANO 1, Atsuhiko TOYAMA 1, Kumie SATOU 2, Yuki NAKAMURA 2, Jun WATANAB 1 (1) Shimadzu Corporation, Kyoto, Japan. (2) LSI Medience Corporation, Tokyo, Japan.

Introduction Catecholamine levels in plasma, namely norepinephrine (), epinephrine () and dopamine (), give indication of disease states and are routinely measured for clinical research. Recently, plasma catecholamine metabolites such as metanephrine (MN) and normetanephrine (NMN) are increasingly studied as an alternative of or to complement catecholamine levels. Therefore high-sensitivity and high-throughput analytical system that covers all of these compounds is warranted. Methods Sample Processing In order to detect plasma catecholamines with high sensitivity and accuracy, and minimize instrument maintenance intervals, plasma samples need preparation to remove interfering molecules such as proteins. Such routine work is best multiplexed and automated to maximize efficiency. Fig. 1 describes the 96-plex sample preparation protocol using VOLUT WCX extraction plate and xtrahera, a positive-pressure liquid handling device for automation of solid phase extraction. WCX Solid Phase xtraction Transfer collection plate Pretreatment : Add to 300 μl plasma sample 300 μl of 0.05% formic acid containing deuterated IS compounds Conditioning : 900 μl methanol quilibration : 50 mm ammonium acetate ph 6.0 Sample Apply : Pipette-mix and apply 500 μl to wells Wash 1 : 300 μl 10% methanol Wash 2 : 300 μl isopropanol lution : 250 μl 30% isopropanol 0.5% formic acid Direct LC/MS/MS analysis using the LCMS-8060 Fig. 1 Plasma sample preparation for high-throughput catecholamine and metanephrine determination 2

Analytical conditions Table 1 MRM Transitions Compound Polarity Precursor m/z Product m/z C (V) 152.1 77.1-32 -d6 158.1 81.1-32 184.1 107.1 -d6 190.1 112.1 154.1 137.1-14 -d4 158.1 141.1-14 MN 180.0 148.1-20 MN-d3 183.0 151.1-20 NMN 166.0 106.1 NMN-d3 169.0 109.1 Table 2 HPLC Conditions Column : Shimpack MAqC-ODS I (150 mm x 2.0 mm, 5 μm) Mobile phase A : 0.05% formic acid in water Mobile phase B : Methanol Flow rate : 0.2 ml/min Time program : 1% B (0-0.5 min) 50% B (3 min) 99% B (3.1-6 min) 1% B (7.1-10 min) Column temp. : 40 ºC Injection volume : 5 μl Results Calibration range We first evaluated sensitivity and quantitative range of catecholamine determination using freshly fortified neat standard solution. Table 3 summarizes the quantitative range; this calibration curve fulfilled the criteria of %RSD <15% and relative error <15% (<20% for LLOQ) for all calibration points in 5 repeat measurements. Table 3 Quantitative range of neat standard detection Compound MN NMN Calibration range (pg/ml) 6.8 3380 7.4 3680 6.1 3060 4.4 2190 4.8 2400 R 2 0.9995 0.9998 0.9994 0.9991 0.9994 3

Detection of endogenous catecholamines in plasma sample Next, human plasma samples were processed with xtrahera as described above and the endogenous catecholamine and metabolite compounds were determined by LC/MS/MS for research purpose. The MRM chromatograms acquired (Fig. 2) showed no apparent interference from plasma components, demonstrating low pg/ml sensitivity in real sample. (218 pg/ml) (30 pg/ml) (8 pg/ml) MN (62 pg/ml) NMN (70 pg/ml) 2:152.00>77.10() 2:170.00>107.10() 4:184.00>166.10() 4:184.00>107.10() 8:154.10>91.20() 8:154.10>137.20() 10:180.00>148.10() 10:198.00>148.10() 6:166.00>106.10() 6:166.00>134.10() 0 1.0 2.0 3.0 2.0 3.0 3.0 4.0 3.0 4.0 2.0 3.0 4.0 Fig. 2 Representative MRM chromatograms acquired from a non-spiked, human plasma. Concentrations in parenthesis were determined by the standard calibration curve. Data correlation with a predicate device To evaluate whether the present LC/MS/MS platform gives consistent results relative to conventional methods, the same aggregate of samples were analyzed side-by-side using an established predicate device available in Japan, which is based on fluorescent HPLC detection. Results were summarized in Table 5 and represented as scatter plots shown in Fig. 3. Given on the scatter plots are the equation for linear regression (assumed to pass through the origin). For norepinephrine and epinephrine, both regression slope and correlation coefficient (r 2 ) were close to 1; the data acquired by the present LC/MS/MS method may be regarded equivalent to those given by conventional methods. Norepinephrine pinephrine MS HPLC pg/ml pg/ml Fig. 3 Scatter plots showing the correlation between quantitation given by a predicate device (HPLC) and LC/MS/MS method presented herein (MS). Left panels show the full-scale plot for each compound and right panels are the same plots but enlarging about the origin. Within the enlarged image, color coding of the data points represent sample process batch. 4

In contrast, we observed a strong negative bias in dopamine quantitation by LC/MS/MS (Fig. 4). This may be attributed to the difference in sample pretreatment. While WCX-SP involves mild ph change, conventional methods employ protein precipitation by perchloric acid that causes acid-driven hydrolysis of dopamine conjugates, thus elevating the apparent level of plasma dopamine. Dopamine (x10,000) 4.0 3.0 2.0 1 (x10,000) 2 Acid 5.0 1 ppt. 4.0 3.0 2 2.0 1.0 1.0 0.0 0.0 pg/ml 2.50 2.75 3.00 3.25 2.50 2.75 3.00 3.25 1: Dopamine peak (correct RT) increases by strong acid precipitation. 2: Unknown peak showing same MS/MS response as dopamine decreases by acid precipitation Fig. 4 Scatter plot displayed in the same format as Fig.3 that demonstrates limited correlation for dopamine. Right panel shows pilot result that suggests possible explanation to the observed discrepancy. Table 4 Summary of catecholamine quantitation by HPLC and MS. Group Conc. Range (HPLC) n Mean (HPLC) Mean (LCMS) Bias by LCMS x. Low < 100 16 76.6 78.1 2.0% Low 101-300 116 214.3 188.8-11.9% Mid 301-1000 148 468.0 431.6-7.8% High 1001-5000 9 1622.7 1495.6-7.8% x. High > 5000 1 5313.0 4724.0-11.1% x. Low < 10 42 7.1 10.6 49.3% Low 11-30 136 18.8 21.1 12.2% Mid 31-50 56 39.2 40.1 2.3% High 51-200 45 80.9 81.1 0.2% x. High > 200 7 553.1 561.5 1.5% x. Low < 10 39 7.9 7.4-6.8% Low 11-30 190 18.0 13.9-23.2% Mid 31-50 26 37.7 21.8-42.2% High 51-200 16 102.6 59.3-42.2% x. High > 200 5 1293.0 1044.5-19.2% Samples were grouped according to concentrations determined by HPLC 5

Conclusion The described high-throughput method achieved sufficient sensitivity and linearity to cover biologically relevant concentration range in plasma and was demonstrated for robustness and consistency with conventional methodology. Disclaimer: LCMS-8060 is intended for Research Use Only (RUO). Not for use in diagnostic procedures. First dition: June, 2016 For Research Use Only. Not for use in diagnostic procedure. Not available in the USA, Canada, and China. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. www.shimadzu.com/an/ The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Shimadzu Corporation, 2016