Computational Fluid Dynamics (CFD) Modeling Service

Similar documents
Statement Of Work Professional Services

Rack Hygiene. Data Center White Paper. Executive Summary

Airflow Simulation Solves Data Centre Cooling Problem

Energy Management Services

FNT EXPERT PAPER. // Data Center Efficiency AUTHOR. Using CFD to Optimize Cooling in Design and Operation.

Data Center Power Consumption

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Data Center Optimization Services. Maximize Your Data Center

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Thermal Management of Datacenter

Managing Cooling Capacity & Redundancy In Data Centers Today

APC APPLICATION NOTE #92

FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager

Airflow Management Solutions

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Using CFD for optimal thermal management and cooling design in data centers

DATA CENTER ASSESSMENT SERVICES

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

W H I T E P A P E R. Computational Fluid Dynamics Modeling for Operational Data Centers

Choosing Close-Coupled IT Cooling Solutions

How To Run A Data Center Efficiently

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Data Centres at the core of your business

Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment

Green Data Centre Design

Modeling Rack and Server Heat Capacity in a Physics Based Dynamic CFD Model of Data Centers. Sami Alkharabsheh, Bahgat Sammakia 10/28/2013

POWER. Your Partners in Availability POWER

Technology Corporation

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Specialty Environment Design Mission Critical Facilities

Boosting the Energy efficiency of a Server Room: experimental + virtual approach.

Design Best Practices for Data Centers

An Introduction to Cold Aisle Containment Systems in the Data Centre

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Data center upgrade proposal. (phase one)

Data centers have been cooled for many years by delivering

Analysis of the UNH Data Center Using CFD Modeling

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

DATA CENTER INCENTIVES

National Grid Your Partner in Energy Solutions

The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers

Server Room Thermal Assessment

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

Application of CFD modelling to the Design of Modern Data Centres

Data center management suite. Providing optimal control and efficiency to data center management.

Data Center Lifecycle and Energy Efficiency

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

Managing Data Centre Heat Issues

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

How To Improve Energy Efficiency Through Raising Inlet Temperatures

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Centre/Server Room Containment: How to Get More Cooling Capacity without Adding Additional AC

Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens.

Overview brochure. Power management solutions for network closets, server rooms and data center environments

Increasing Data Center Resilience While Lowering PUE

Can Your Data Center Infrastructure Handle the Heat of High Density? 5 Ways to Test Your Data Center Infrastructure before Installing Blades

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

Introducing the. Virtual Facility

Benefits of. Air Flow Management. Data Center

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Airflow Management Solutions

Benefits of Cold Aisle Containment During Cooling Failure

Anixter ipassured SM for Data Centres. Products. Technology. Services. Delivered Globally.

How Row-based Data Center Cooling Works

Strategies for Deploying Blade Servers in Existing Data Centers

Introducing AUDIT- BUDDY

Reducing Data Center Energy Consumption

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Reducing the Annual Cost of a Telecommunications Data Center

The New Data Center Cooling Paradigm The Tiered Approach

Data Centre Testing and Commissioning

Energy Efficiency and Availability Management in Consolidated Data Centers

Using Simulation to Improve Data Center Efficiency

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

Using Simulation to Improve Data Center Efficiency

CDW Technology Services

Statement of Work Server Migration & Cable Management. Installation Services. Table of Contents. 1.0 Executive Summary. 2.0 Features & Benefits

Best Practices for Wire-free Environmental Monitoring in the Data Center

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

APC APPLICATION NOTE #112

Bridging the gap for optimized efficiencies and smarter decisions

Scalable. Affordable. Flexible. Fast.

Rethinking Data Center Design

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

WHITEPAPER THE FUTURE IS CUSTOM: A TOTAL COST OF OWNERSHIP APPROACH TO DATA CENTER INFRASTRUCTURE DESIGN

DESIGN YOUR DATA CENTER FOR TODAY & TOMORROW.

Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.

Best Practices for Wire-free Environmental Monitoring in the Data Center

Power and Cooling for Ultra-High Density Racks and Blade Servers

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Transcription:

Eaton Data Center Services Computational Fluid Dynamics (CFD) Modeling Service Executive Summary Improve data center energy performance As organizations fill data center enclosures with increasing numbers of high density servers, our customers are looking to us for help and advice on: How to add high density servers and increase rack density in an energy efficient way. Analyzing data center energy performance and potential improvements. Determining efficient data center cooling methods. Discovering problems with energy profiles of existing data centers and predicting design limitations of new or expanding facilities. It all adds up to increased performance and a more energy efficient data center with the added benefit of knowing that Eaton has energy efficiency and savings at the core of our service delivery and expertise. What you don t know can hurt you By modeling the airflow, temperature, static pressure, and energy profiles of various dynamic critical environments, the CFD Services provided by Eaton can compare and substantiate which design decisions will maximize your data center flexibility, scalability, and resilience. Creating a CFD baseline model addresses your existing facility concerns today, and more importantly your baseline can be revisited and quickly updated in the future. This valuable service allows you to explore your best options for IT and facility growth, create a calculated plan, and avoid major capital commitments or costly design or implementation mistakes. Measurement is the key. There is no question that the correct approach to reducing energy consumption is to begin by measuring, establishing a baseline, and tracking performance for your facility. Computational Fluid Dynamics (CFD) Modeling The Eaton CFD Service constructs a virtual representation of your data center, modeling the impact of load distribution within the facility as well as the flow of hot and cool air within the space. The CFD modeling analysis is essential for fine tuning your current facility to optimize its efficiency, and can demonstrate how to increase your rack densities and server installations without creating additional hot spot and airflow issues. Eaton is assisting data center operators to make science-based decisions aimed at improving operational efficiency and reliability. SERVICE OVERVIEW Trained and Certified CFD Service Professionals Experienced and Knowledgeable Team World Class Manufacturing Support Predictive Analysis Details of Service Ensure that the customer s CFD requirements and schedules are met on or ahead of time. The CFD Service Team is comprised of personnel with cross-disciplinary experience that has made us leading experts at working in live critical environments. The CFD Service Team is backed by the entire manufacturing and engineering capability of Eaton to meet demands in short cycle times and keep project schedules intact. The CFD Service Team is engaged to deliver a focused plan for improving the lifecycle of your data center environment and resolving potential problems before they arise. Eaton s experienced team is certified and trained on state-of-the-art CFD modeling software. The Eaton CFD Service offers customers a virtual three-dimensional model of their data centers, individual rooms, rows, and/or racks. Eaton s computational fluid dynamics service lets customers choose from preset service levels or customize the service to meet their specific needs. The level of CFD Service determines how much information is available about the performance of your data center environment and accuracy of recommended data center solutions. A thorough and detailed site audit provides better analysis of current conditions and more precise modeling of proposed changes. Service levels and deliverables are detailed in the following pages.

CFD 1.0 SCOPE OF WORK Customer Provided Site Audit Major obstructions including posts and columns within the internal space only (not including plenum space). Models will be based on power consumptions on a per rack/enclosure basis only. Customer validation of data. based on the existing data center design, with the following information: Eaton Data Center Audit form. Eaton : 2 EATON CORPORATION

CFD 1.1 SCOPE OF WORK Eaton Site Audit Major obstructions including posts and columns within the internal space only (not including plenum space). Models will be based on power consumptions on a per rack/enclosure basis only. Customer validation of data. based on the existing data center design, with the following information: Eaton Data Center Audit form. Unrestricted access should be made available to all areas of the facility to accommodate the site audit and measurement information where required. Eaton : Schedule an onsite visit to validate and collect facility data for CFD Service. 3 EATON CORPORATION

CFD 2.0 SCOPE OF WORK Customer Provided Site Audit Major obstructions including posts and columns within the internal space only (not including plenum space). Models will be based on power consumptions for each rackmounted device within the rack/enclosure. based on the existing data center design with the following information: Eaton Data Center Audit form. Eaton : 4 EATON CORPORATION

CFD 2.1 SCOPE OF WORK Eaton Site Audit Device Details: Manufacturer and Model. Rack units height. Rack unit location within which rack. Major obstructions including posts and columns within the internal space only (not including plenum space). Models will be based on power consumptions for each rackmounted device within the rack/enclosure. Customer validation of data. based on the existing data center design, with the following information: Eaton Data Center Audit form. Unrestricted access should be made available to all areas of the facility to accommodate the site audit and measurement information where required. Eaton : Schedule an on-site visit to validate and collect facility data for CFD Service. 5 EATON CORPORATION

Custom CFD Services Eaton offers other customized CFD services. Some sample services are listed below but other services may be offered through consultation with Eaton professional services. Failure Mode Analysis Failing component(s) within baseline model and indentifying steady state thermal properties and capacities with respect to the changes. Simulated Solution Modeling Modeling a recommended or alternative solution as a retrofit or upgrade to existing baseline model. Validation of Measured Data Gather measured data within data center and compare to existing baseline model Application of Measured Data Rework baseline models based on captured measured data Transient Behavior Calculate real time thermal behavior from baseline models if either a CRAC(s) or Chiller were to fail. Virtual Walk Through An animated walk through illustrating the airflow dynamics within the data center. Other Services Eaton offers the following services, which can be integrated with the installation process: Removal and disposal of old enclosure and equipment Anti-Tip Anchoring Seismic Bracing Warranty Validation Product Moving and Reconfiguration Pricing Pricing for Eaton CFD Services is available on an order by order basis. A pre-quote consultation and/or walk-through by an Eaton Service Team member may be advised to determine the scope and level of CFD service. Changes in the CFD Service agreement or changes in the assumptions or CFD Service specifics after the original Eaton scope/statement of work is set may require a new CFD Service agreement. Contact your Eaton Sales Representative for a quote according to your specific requirements. Terms and Conditions Standard Eaton terms and conditions apply, available in the sales quote package, at www.eaton.com/wrightline, or by contacting your Eaton Sales Representative. Eaton Corporation Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved Publication No. SER100FXA/0212 To contact an Eaton salesperson or local distributor, please visit www.eaton.com/wrightline or call 800-225-7348