Fact sheet 6: for farmers



Similar documents
Fact sheet 6: for farmers

PPG2. Pollution Prevention Guidelines. Above Ground Oil Storage Tanks: PPG2. 1. Introduction. 2. The storage container.

Domestic heating Fuel storage tanks

ABOVE GROUND OIL STORAGE TANKS: PPG2

Get to know your oil tank. A guide to looking after an oil storage tank and avoiding pollution

Environmental Management System Procedures

GUERNSEY OIL INSTALLATION GUIDELINES

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

Spill Prevention, Control and Countermeasure (SPCC) Rule

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

Civil Engineering Sector Labour-Management Health and Safety Committee

APPENDIX O. Spill Prevention and Emergency Response Plan. G3 Terminal Vancouver Port Metro Vancouver Project Permit Application APPENDIX O


E. Fowler & Sons Ltd.

Pesticide Spills. Chapter 26. In This Chapter. Keywords. Accidents. Pesticides Act and Environmental Protection Act

GUIDANCE NOTE FOR THE WATER ENVIRONMENT (OIL STORAGE) (SCOTLAND) REGULATIONS 2006

Intelligent Spill Control. & Containment Solutions

Underground Storage Tanks

ANNEX 2 Emergency / Pollution Incident Response Plan

Spill Control Prevention Plan (SCPP)

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

Farm Fuel Tank Safety Guide

History of the SPCC Rule

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

How to comply with your environmental permit

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

Best Practice Guide BPGCS005

TECHNICAL BULLETIN. Location of the system. Percolation tests for drainage fields. Cesspool sizing. Suggested Information notices

The Fuel Storage Tank Regulations 2009

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Fuel Storage Who to ask: tank farm owners/operators

Spill Containment. Contents

Appendix J3 - Outline Fuel Spill Contingency Response Plan. Control room receives call on fuel spill from staff or public

Spill Containment control it before it controls you!

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

Spill Containment. Contents

SPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN PREPARED FOR: ARKANSAS STATE UNIVERSITY JONESBORO, ARKANSAS ORIGINAL DATE OF PLAN: APRIL 2005

PPG21. Pollution Prevention Guidelines. pollution incident response planning: PPG Introduction

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

FUELING AND FUEL STORAGE

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

TECHNICAL REVIEW OF SECONDARY CONTAINMENT SYSTEM TECHNOLOGY FOR ALASKA

Suffolk County Department of Health Services. Division of Environmental Quality

OREGON FIRE CODE Interpretations and Technical Advisories

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

Good Housekeeping Practices for DPW/Fleet Maintenance Facilities

PCB STORAGE. 1) 2-drum unit (4 x 2 x 4 ) 2) 4-drum unit (4 x 4 x 4 ) 3) 8-drum unit (8 x 4 x 4 ) 4) 16-drum unit (8 x 8 x 10 )

ABOVE-GROUND STORAGE TANKS

Construction Management Statement. Residential development at Bywell House, St Mary s Hill, Ascot

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

OIL CONTAINMENT AND SPILL MITIGATION M-04 ISSUE: F SEPTEMBER 2001

SPILL PREVENTION PLAN

Examples of pressure systems and equipment are:

Environmental Management Plan

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Kurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Managing Floor Drains and Flammable Traps

NFPA31FuelOilPiping 1 Revised

UNIVERSITY OF WISCONSIN MADISON

Temporary Batch Plants

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Essential Water. Customer Charter

Petroleum (Consolidation) Regulations 2014

The following definitions apply with regard to requirements specified in this document:

UltraTech International, Inc. Canadian Secondary Containment Requirements

Chapter 2 Stormwater Pollution Prevention Plan (SWPPP) for Park Operations

BEHANS LAND RESTORATION LIMITED RESTORATION OF FORMER QUARRY BLACKHALL, CO. KILDARE OUTLINE CONTINGENCY PLAN MAY 2008

DEALING WITH PLUMBING AND HEATING EMERGENCIES

Chemical Storage and Spill Response Guidelines

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

APPENDIX 7-B. Hazardous Materials Management Plan

Pollution Prevention Guidelines: PPG1 July 2013

Outdoor Liquid Container Storage

APPENDIX G Materials Storage and Handling Guidelines

Rutgers Environmental Health and Safety

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

Outdoor Storage of Raw Materials SC-33

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

Attachment N o F.2. Please find attached the following procedure: EP-907 Handling Hazardous spills

HYDROCARBON SPILLS PROCEDURE SIG-ENV-PR003

Drainage. Information for those with problem drains

MPM. Customer Service Representative Training. Class C Fuel Spill Handling

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE

Waste Oil Collection / Storage

How To Safely Handle A Spill

Transcription:

Fact sheet 6: for farmers Fuel Oil Storage February 2011 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The Water Resources (Control of Pollution)(Silage, Slurry and Agricultural Fuel Oil) Regulations 2010. These are commonly referred to as SSAFO, and apply in England and Wales. If after reading these notes you're still unsure about your fuel oil management or any other aspect of your farming operation which may be affected by these regulations, please contact us before starting any works. Mistakes can be expensive, or result in additional works being required. Compliant gravity fed system What is a fuel oil store? A fuel oil store can be a single tank, multiple tanks, or drums. They can be in one area or spread across your farm. Mobile bowsers or drums temporarily stored alongside mobile plant are exempt from the Regulations but you should still take precautions to prevent and contain spillages. Providing it is stored separately, oil used exclusively for domestic heating or power is covered by other regulations and advice can be obtained from www.oftec.org. Oil stored and used for non-agricultural activities in England, may be subject to The Control of Pollution (Oil Storage) (England) Regulations 2001. See the 'Where can I get further help?' section on how to get more information. What do the Regulations mean for my oil storage? You have to comply with the SSAFO Regulations where the total quantity of agricultural fuel oil stored on the farm is more than 1,500 litres. You may be exempt if your oil storage was in place before 1991 but please consider bringing your storage up to the regulatory standard. You must notify us in writing about any new, substantially enlarged or substantially reconstructed fuel oil storage at least 14 days before it is first used, but we encourage you to contact us at the design stage. Your notification must include the type of structure and its location. We can provide a form to help you do this or you can download one from our website. Requirements that apply to fuel oil stores The basic requirement is for tanks or drums to be surrounded by an impermeable secondary containment structure or bund. The size of the secondary containment / bund is shown in the table below.

No part of the system can be within 10 metres of inland freshwaters or coastal waters that fuel oil could enter. This includes yard drains and dry ditches, and land drains. The walls and the base of the secondary containment must be impermeable to oil and water and not have a drain down pipe. Every part of the oil container must be within the bund. This includes sight gauges, tank draindown valves and shut-off valves associated with fixed or flexible draw-off delivery pipes. Taps and valves through which oil can be discharged must be within the bund. They must be directed down into it and locked shut when not in use. Flexible delivery pipes permanently attached to the primary tank must be fitted with a self-closing tap or valve at the end. They must be locked inside the bund when not in use. The secondary containment / bund, when new, must have a 20-year life expectancy with maintenance. Storage type Single tank Multi-tanks Drum(s) Capacity of secondary containment / bund 110% capacity of the tank 110% of the capacity of the largest tank or 25% of total volume that could be stored in all tanks in the area, whichever is the greater. At least 25% of the total volume that could be stored at any time. What are the different tanks available for oil storage? Not all makes of tank or tank systems meet the requirements of the regulations. Tanks are sold under a variety of names (single skin, double skin, integrally bunded, tank system, or fuel stations etc) and are available in both plastic and metal. The principles of compliance apply to both materials. Plastic tanks are becoming the most commonly installed products on farms. Tank manufacturing and quality standards There are recognised British Standard and trade association tank standards for different types of tank. Tanks should comply with BS EN ISO 9001, and plastic and steel tanks and tank systems manufactured to OFTEC Standards OFS T100 and OFS T200 respectively, meet the British Standard.

Your tank manufacturer, supplier or installer should advise you on the minimum design and manufacturing standards under the appropriate accredited quality assurance scheme, but please note that compliance with standards for construction and manufacture doesn t guarantee compliance with SSAFO. How can the different tank designs comply with the regulations? Single-skinned tanks A single-skin tank or primary container always requires secondary containment (a separate bund) to comply. It must be constructed in-situ, enclosing the container and its ancillary equipment. Where a bund is constructed from brick or concrete block, it should be reinforced, and must be rendered on the inside with waterproof oil resistant material. You can find more information in the 'masonry bunds for oil storage tanks' document. We can provide you with a free copy on request, or you can download it from our website. Double-skinned tanks A double-skinned or twin walled tank is a primary container with another skin around it with a small gap in between. The second skin often provides some structural support to the inner container, and none of the pipe work or ancillary equipment is contained, so isn't a bund. Double-skinned tanks therefore don't comply with the SSAFO regulations unless a separate bund is provided around the tank and ancillary equipment. Underground tanks are not governed by the SSAFO regulations. Where tanks have to be installed underground, we recommended double-skinned tanks are used for underground installations. The space between the tank skins can be monitored for leaks of oil or petrol. Underground installations should also have twin-walled, non-corrosive pipe work specified, and need to follow the Defra Groundwater Protection Code. Self bunded or integrally bunded tanks, and fuel stations etc They are specifically-designed and manufactured oil storage containers with an integral bund that protects the container and its ancillary equipment. They will come in various designs from several manufacturers. Manufacturers and suppliers may make claims about the environmental performance of their products but some tank systems may not comply with all the SSAFO regulations. Here are some factors to look out for: Bottom off take tanks These tanks have the outlet from the primary tank at the bottom. Where they rely on a gravity feed to an external factory-fitted off-take point fitted with a flexible delivery hose, it does not meet the SSAFO regulations and requires additional containment with a bund.

Where the off-take is to serve fixed plant such as a grain dryer via a solid feed pipe, they do meet the regulations. Most tanks are supplied with a pre-installed coupling for this purpose. It's good practice to specify a tank system that has an accessible shut-off valve inside the bund, that you can use in the event of a leak, plant maintenance, or periods of plant shut-down. A variation of this is where a flexible delivery hose is fitted but it's kept in a lockable cabinet fitted to the end of the tank. Although they provide some extra protection because the cabinet has a built-in drip tray and the flexible delivery hose can be locked away from vandals, they do not meet the SSAFO regulations. If the tank delivers fuel using a pumped system and the flexible delivery hose can be kept inside the bund after use, then it does meet the SSAFO regulations. It also has the benefit that the facility can be sited at ground level avoiding risks with high-level supports, and allows easy access for filling and inspection: it does not rely on gravity for the fuel delivery, and everything is contained. A further alternative has the pump-set external to the tank, connected to the tank by a fixed pipe. The flexible delivery hose doesn't need to sit within the bunded area to be compliant with the SSAFO regulations, but it should have its own protection from spillage and unauthorised use. Top off take tanks Compliant Pumped system These tanks draw the fuel from an outlet at the top of the tank. This means that a pump and non-return valve is required to dispense fuel, making them inherently safer. Tank systems are available as complete fuelling stations with all valves and pipe work within the bund. They comply with the SSAFO regulations. How do I meet the 20-year life expectancy requirement for bunds? Bunds designed and constructed from masonry or reinforced concrete, and rendered with waterproof material, should readily meet this requirement with routine maintenance. See the other information section. Where integrally bunded plastic tanks are concerned the life expectancy of the bund is essentially the same as the tank. Some tanks have a 10-year guarantee, others have only one year which is renewable after inspection. Evaluating these tanks against the 20-year life expectancy is therefore difficult. You should seek assurance from the manufacturer about the likely maximum life of the product and what maintenance should be undertaken to ensure this. Where the manufacturer can t provide this information you should consider replacing the facility at the end of the guarantee, or at the end of the guarantee period, seek an annual independent verification that it is suitable for continued use.

What happens after I submit proposals to the Environment Agency? We will assess your proposals and the site. In some cases we will visit the site and meet with you or your agent. We will make our assessment clear to you in writing. What happens if an oil spill occurs? Keep a spill kit with commercial sorbent products close to your oil storage to deal with spills, and make sure you or your staff know how to use it safely. Alternatively use sand, or earth. If you have a spill, take immediate action to stop the oil getting into any drains or watercourses. Notify us by calling the incident hotline below; If you can, soak up the spilt oil with the contents of your spill kit, without putting yourself in danger; Don t hose the spillage down or use any detergents to try to get rid of it as you could make the pollution worse. If oil soaks into the ground, the soil soaked in oil should be removed, by a professional company, so it doesn t cause long term pollution. Store any materials that are soaked in oil in containers that won t let the oil run away until it can be correctly and legally disposed of. What happens if pollution occurs? The responsibility for preventing pollution falls to the person with custody or control of the installation. Normally that is you, the farmer. If pollution occurs you may be liable, even if we have agreed to the system installed. Great care is therefore essential in the construction, operation and maintenance of the system to ensure it continues to perform properly. We recommend all your oil storage tanks have an Oil Care Campaign sticker that tells you what to do if you have an oil leak or spill. Call our customer service line to ask for a free sticker. Where can I find further help? You can find further information in the Guidance Notes for Farmers documents we have prepared with Defra and Welsh Assembly Government. We can provide you with free copies of these and other general information on oil storage, and masonry bunds for oil storage tanks, on request to our customer service line, or you can download information from our website - enter 'agriculture' in the search facility. Also see: BS 799-5:1987 Oil burning equipment - Specification for oil storage tanks. Groundwater Protection Code: Petrol Stations & Other Fuel Dispensing Facilities Involving Underground Storage Tanks If you are still unsure please contact your local Environment Agency office via the customer service line.