MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)



Similar documents
STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

SECTION STANDING SEAM METAL ROOF

PRODUCT CONTROL SECTION

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Metal Roofing Practical Design

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

GUIDELINE SPECIFICATIONS

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

VERTICAL LOCK Table of Contents

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Standing Seam Roof Systems

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

PBR & R Panel. Table of Contents

SECTION PREFORMED METAL STANDING SEAM ROOFING

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL ROOFING PERMIT APPLICATION

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Design No. P736 September 26, Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

metals LLC Metal roofing ON-DEMAND

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

SECTION STANDING SEAM METAL ROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING

CHAPTER 7: Building Systems ROOFING SYSTEMS

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Preformed Metal Roofing and Siding

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

Detached accessory structures that contain no conditioned floor area are exempt.

SECTION METAL ROOF & WALL PANELS

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Installation Manual for STANDING SEAM ROOFING

Slim Seam Architectural Design Manual

238T Standing Seam Metal Roof System (SSMRS)

Residential Roofing Guide

SECTION PREFORMED METAL ROOF PANELS

DENVER MODEL 30 X 30 SPECIFICATIONS

APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE

Metal Roof Systems in High-Wind Regions

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Wind Mitigation Inspection

Iinterviewed with a school district

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Classic Products, Inc. ClickLock Standing Seam Installation Manual

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS

PART 1 GENERAL 1.1 SECTION INCLUDES

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Asphalt Shingle Application Requirements

Fire Barrier Duct Wrap 15A

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

metal Duil~ing manufacturers Association

PRODUCT SPECIFICATIONS

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

VAIL Metal Shingles. Application Instructions. Custom-Bilt Metals Magnolia Ave. Chino, CA 91710

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

DETAIL MANUAL. for Standing Seam East 23rd Street Chattanooga, TN South Lee Hwy. Cleveland, TN 37311

STANDING SEAM METAL ROOFING DETAILS PDF

Residential Decks. Planning and Development Services Department

STAY. Residential & Light Commercial INSTALLATION MANUAL

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

TARRANT COUNTY DETAIL STANDARDS

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

STRUCTURAL STANDING SEAM ROOF SYSTEMS

SECTION METAL ROOF SYSTEM

SECTION STANDING SEAM METAL ROOFING

Window Installation Instructions

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

Global Hybrid Roofing Solutions (Delaware) LLC

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Double-Lok. Technical/Installation Information

Florida Building Code Approval

SECTION THERMOPLASTIC MEMBRANE ROOFING

SL-16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information

SL 16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Transcription:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) Firestone Building Products Company, LLC. 250 W 96 th Street Indianapolis, IN. 46260 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: UC-3 Steel Standing Seam Metal Roof Panels on 22 ga. B-Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#11-0210.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. Page 1 of 7

ROOFING ASSEMBLY APPROVAL: Category: Sub-Category: Material: Deck Type: Maximum Design Pressure Roofing Non-Structural Metal Roofing Steel 22 ga. (0.032 min.) G90 galvanized Steel B-Deck. -101 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: UC-3 Trim Pieces Panel Clips Product Dimensions Test Specifications l = various w = 16 or 20 h = 1.50 Min. 24 ga. (57.20 ksi min. yield) l = varies w = varies min. 24 ga. Clip base 1.0" wide x 0.420 high x 5.0 long 0.0275 thick galvanized (ASTM G90) Steel, 50 ksi (min. yield) Clip top 0.412" wide x 1.870 high x 3.0 long 0.0235 thick galvanized (ASTM G90) Steel, 50 ksi (min. yield) TAS 110 TAS 110 TAS 114 Appendix E TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS: Product Dimensions Test Specifications Bostik 70-05A Sealant MANUFACTURING LOCATION: 1. College Park, GA. 2. Jackson, MS. 3. Anoka, MN. Product Description Corrosion resistant, galvalume or galvanized, preformed, standing seam, coated, prefinished, metal panels. Standard flashing and trim pieces. Manufactured for each panel width. Corrosion resistant, formed, painted or unpainted steel clips for metal panel installation. Manufacturer N/A N/A Bostik, Inc. Page 2 of 7

EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center For Applied Engineering, Inc. MTS 257364 PA 100 Sept. 1995 Akzo Coatings ASTM G 23 ASTM B 117 Valspar Corporation Hurricane Test Laboratory, Inc. Hurricane Test Laboratory, LLC 435B187 435A871 ASTM G 23 ASTM B 117 0227-0226-04 TAS 125 06/29/04 0227-1207-05 TAS 125 04/20/06 Architectural Testing C7712.01-450-18 TAS 125 09/11/13 Page 3 of 7

APPROVED ASSEMBLIES: System A: Deck Type: Deck Description: Slope Range: Maximum Uplift Pressure: Deck Attachment: Insulation: UC-3 Standing Seam 16 wide Steel Roof Panels Steel, Insulated 22 ga. (0.032 min.) G90 galvanized Steel B-Deck. 2": 12" or greater See Table A below Deck shall be attached in accordance with applicable Building Code, but in no case shall it be less than 5/8 diameter puddle welds 12 o.c. to the supports that spaced at 48 maximum, 5/8 diameter puddle welds 6 o.c. around deck perimeter to the supports, ¼ x ¾ HH stitch screws at 12 o.c. at the deck sidelaps. Minimum ¾ thick maximum 4 thick of an approved rigid board insulation with current NOA having a minimum 20psi compressive strength fastened with approved #12 pan head self tapping screws, with insulation plates, long enough to penetrate the deck. Fastening density shall be in compliance with applicable Building Code and Roofing Application Standard RAS 117. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4 side-lap and 6 end-laps. Underlayment shall be fastened with #12 x 4 truss head screws with insulation plate spaced 24 on center in the field of the roll and its perimeter. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Firestone Metal Products current published installation instructions. Metal Panels and Accessories: Install the "UC-3 Standing Seam 16 wide Steel Roof Panels" and accessories in compliance with Firestone Metal Products current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Each roof panel is mechanically attached to the Steel B-Deck along it s male rib using the approved clips (5.0 long x 1-5/16 wide x 1-15/16 tall) located 6 from each panel end and 12 o.c. (Roof s Field) and 6 o.c. (Roof s Perimeter and Corner) thereafter. Each clip is attached to B-Deck substrate with two corrosion resistant #12 x 3 Pancake Head SMS screws of sufficient length to penetrate through the B-Deck. The adjacent panel is placed over the male rib/clips then mechanically seamed 90 degrees. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner 2 Maximum Design Pressures 71 psf 101 psf Maximum Clip Spacing 12 o.c. 6 o.c. 1. Extrapolation shall not be allowed Page 4 of 7

System B: Deck Type: Deck Description: Slope Range: Maximum Uplift Pressure: Deck Attachment: Insulation: UC-3 Standing Seam 20 wide Steel Roof Panels Steel, Insulated 22 ga. (0.030 min.) ASTM A653, SS GRD 33, G60 galvanized Steel B-Deck. 2": 12" or greater See Table B below Deck shall be attached in accordance with applicable Building Code, but in no case shall it be less than #12 x 2 Tek 3 screws spaced 6 o.c. to the supports that spaced at 60 maximum. Overlaps are secured with #12 x 2 Tek 3 screws spaced at 6 o.c. Minimum ¾ thick maximum 4 thick of an approved rigid board insulation with current NOA having a minimum 32psi compressive strength fastened with approved #12 pan head self tapping screws, through a 2-7/8 diameter insulation plate, long enough to penetrate the deck. Fastening density shall be in compliance with applicable Building Code and Roofing Application Standard RAS 117. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4 side-lap and 6 end-laps. Underlayment shall be fastened with #12 x 4 truss head screws with insulation plate spaced 24 on center in the field of the roll and its perimeter. Or, any approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Firestone Metal Products current published installation instructions. Metal Panels and Accessories: Install the "UC-3 Standing Seam 20 wide Steel Roof Panels" and accessories in compliance with Firestone Metal Products current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Each roof panel is mechanically attached to the Steel B-Deck along it s male rib using the approved clips (5.0 long x 1-5/16 wide x 1-15/16 tall) located 5 from each panel end and then as per Table B below thereafter. Each clip is attached to B-Deck substrate with two corrosion resistant #12 Pancake Head SMS screws of sufficient length to penetrate through the B-Deck. The adjacent panel is placed over the male rib/clips then mechanically seamed 90 degrees. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner 2 Maximum Design Pressures 71 psf 161 psf Maximum Clip Spacing 16 o.c. 6 o.c. 2. Extrapolation shall not be allowed Page 5 of 7

SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer s name and/or logo, city, state, and the following statement: Miami-Dade County Product Control Approved or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer s name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. Page 6 of 7

PROFILE DRAWINGS UC 3 PANEL (STIFFENING RIBS OPTIONAL) PANEL CLIP END OF THIS ACCEPTANCE Page 7 of 7