PXL-250: Network Wiring



Similar documents
No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

No Phone Line II-48 System

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Troubleshooting and Diagnostics

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Chapter 9. Bonding and Grounding

HSG Engineering Tech Bulletin

Telebyte 209 Short Haul Modem

LocoNet, the Digitrax Difference

PXL-500 / PXL-510 Tiger Controller Quick Start Guide

Installation instructions for Series NRX INCOM communications adapter module

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Wiring RS-485 Networks

KERI SYSTEMS Keri System Components. Keri System Components

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

ELCOMPONENT LTD. User Manual

Access control designed simply for you

Fire Fighter Phone System Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

MechoNet TM Network Interface (MNI) Specification Submittal

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

BACnet Automation Interface Module (Network Version)

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

STREETLIGHT SYSTEM GROUNDING AND BONDING

Video Camera Installation Guide

Troubleshooting and Diagnostics

TAC1 Telephone Entry System Installation and Programming Manual

Crown Jewel Telephone entry system

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

TC Grounding and Bonding for Telecommunications Systems

Model 201 Wiegand Touchpad Reader Installation Guide

David Brender Copper Development Association Inc. Miramar, March 8, 2013

How To Fix A Cbus Network From A Power Supply To A Power Source

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

EQUIPMENT SPECIFICATIONS

ISHIDA BC Scale to Scale Communications

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Canopy Surge. User Manual

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

ATS Communication Overview

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Lightning Arresters P KVA P KVA. Description & Installation

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

WIRELESS READER INTERFACE - INDOOR

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

SECTION FIRE ALARM AND DETECTION SYSTEMS

Security Cameras, CATV, GPS & Satellite Protection. White Paper

Troubleshooting accelerometer installations

DS A 07/99 MN MI I/A SERIES MICRONET INTERFACE APPLICATION SPECIFICATION

Parallel Redundant Uninterruptible Power Supply

Audio, power, and control data

Grounding & Bonding Why it is done And How to Install Properly

Communication Setup Application Note

How To Wire Wire Wire For A Decoder System

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Structured Cabling, Earthing & Equipotential Bonding

The Basics of Loop Vehicle Detection

EoVDSL: A Cost-Effective Solution for Transmitting Ethernet Data Over Existing Copper Wiring for ITS and Traffi c Applications

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

White Paper: Electrical Ground Rules

Installation manual. Version

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL

800 Communications Circuits

What is BACnet MS/TP?

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Ethernet Patch Cord Wiring

Lightning Protection Guide. PTP 400 and 600 SERIES

ST Series POWER SUPPLIES USER INSTRUCTIONS

SECTION 22 LIGHTNING PROTECTION SYSTEM

LOXONE 12 Channel Amplifier

Installation Instructions

Network Operation and Troubleshooting

Operating Instructions

Introduction to Data Centre Design

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

GEU Port Gigabit Switch

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

Network Cabling Guide

Applied Electronics. Commercial Dimming System UPDATE NOTICE

ASC and N2 Bus Networking and Troubleshooting Guide

Nexus Technology Review -- Exhibit A

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

INTERIM MARKET DOCUMENT CHANGE

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Transcription:

This document provides the network wiring requirements for a PXL-250 access control network. Network Requirements The PXL-250 uses a half-duplex, RS-485 communication bus. Per the RS-485 specification, the access network communication bus is guaranteed to communicate with a total network cable length of up to 4,000 feet and with the controllers connected in a single, continuous daisy chain. However, Keri Systems has identified specific extended network configurations that could be used to wire a controller network communication bus (subject to certain limitations defined on page 2). These configurations include a star pattern network communication bus, a spur cable length of up to 5,000 feet, and a total network cable length of up to 16,000 feet. Lab tested extended network configurations are presented beginning on page 2. Cable Requirements The RS-485 network should be wired using a cable with the following characteristics: twisted, shielded pair of stranded AWG 24 conductors (such as Belden 9501 or a larger gauge). Earth Ground Requirements A quality earth ground connection to the master controller is required to ensure the best possible operating conditions. Without a quality earth ground connection, an access control network may appear to operate correctly, but will be extremely susceptible to transients and electromagnetic interference. An earth ground brings all electrically neutral lines to the earth s surface potential (essentially a zero potential) providing three benefits. 1. An earth ground protects the network from electrical transients such as power surges and lightning strikes (also providing a degree of safety for an operator). 2. An earth ground provides a path to ground for electrical interference, minimizing data and communication problems for the reader data and network communication lines. 3. Through a feature on the PXL-250 controller, the shield for the entire RS-485 network is automatically grounded at the master controller minimizing communication problems. Possible earth ground sources: 1. copper shrouded ground rod 2. cold water pipe (must be a metal pipe not PVC) 3. steel building frame member (if the building s frame is embedded in the earth) 4. electrical system ground (at the breaker/fuse box) 5. telephone system ground NOTE: Communication buses such as RS-485 often appear to work when installed incorrectly, but can have intermittent communication problems. This intermittence can make diagnosing a problem difficult. Failure to properly install an RS-485 network can result in network communication errors and can cause the access control system to lock up. Application Note PXL-250 (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 1 of 6

Lab Tested Extended Network Configurations PXL-250: Network Wiring Application Note Specific extended network wiring configurations have been lab tested to be compatible with the PXL-250 controller. The extended network configurations described in this section have been verified in the lab to provide proper, reliable communication between all controllers in an access control network. Extended Network Guidelines There are several guidelines for installing an extended network. 1. The network uses a star pattern communication bus. Keri Systems defines a star pattern as a communication network with sets of daisy chained controllers all connected to the master controller at the center of the star. 2. Any daisy chain off the star can have a maximum cable length of 5,000 feet. 3. The total cable length of all daisy chains can be no more than 16,000 feet. 4. Any number of daisy chains can be installed as long as the cabling for these daisy chains meets the above guidelines. 5. Any number of controllers can be installed in any daisy chain (up to the 128-controller limit for the entire network). The Master For the best operating conditions the master controller for the access control network should be at center of the star. If an existing network is being upgraded to an extended network or when installing a new extended network, the master controller printed circuit board must be at level 002 Rev. A or greater to ensure proper network termination. The printed circuit board level information is at the lower right corner of the board (see Figure 1). Lithium Battery PXL-250 04174-002 REV A Figure 1 Location of Printed Circuit Board Level NOTE: Keri Systems has tested the functionality and data integrity of the extended network configurations presented in this document under lab conditions. Because of the nature of extended networks, the operation of extended networks in the field is strongly dependent upon the quality of the installation. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 2 of 6

Generic Extended Network Wiring Diagram Figure 2 is a generic drawing for an extended network, meeting the guidelines listed above. *L1 *L2 Last Last * Total Cable Length for all Daisy Chains in the Network = 16,000 feet (L1 + L2 + L3 + L4 + Lx) Master Last Last Maximum Cable Length for 1 Daisy Chain = 5,000 feet Figure 2 Generic Extended Network Diagram Using Jumper Blocks to Attach Multiple Spurs to a Master The individual wiring locations on the terminal blocks on the PXL-250 controller can reliably hold a small number of wires. Certain star networks may have more spurs to be wired than can be held by the wiring locations. External jumper blocks can be used to make these connections. Perform the following steps to make an external jumper block. 1. Count how many spurs have been run to the master controller. 2. Provide jumper blocks with enough connector points to support three times the number of spurs (each spur has three wires:,, and ). This can be individual jumper blocks with three connectors for each spur or one large jumper block with enough connectors to handle all 3 sets of wires from all spurs (see Figure 3). 4 spurs x 3 wires per spur = 12 wire connection points Figure 3 Determining the Number of Jumper Block Connector Points OR *L3 *L4 Application Note PXL-250 NOTE: The remaining figures assume one large jumper block with enough connectors to handle all 3 sets of wires from all spurs has been provided for connecting wires. 3. On one side of the jumper block connect all three wires from each spur (see Figure 4). (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 3 of 6

Application Note Figure 4 Connecting the Spur Wires to One Side of the Jumper Block 4. On the other side of the jumper block connect jumper wires between each of the Txconnectors (see Figure 5). 5. Connect jumper wires between each of the connectors. 6. Connect jumper wires between each of the connectors. All s All Lines All Lines PXL-250 Figure 5 Jumpering Like Wires Together 7. Connect a single line from one of the connectors to TB-1/Pin-1 on the master controller (see Figure 6). 8. Connect a single line from one of the connectors to TB-1/Pin-2 on the master controller. 9. Connect a single line from one of the connectors to TB-1/Pin-3 on the master controller. (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 4 of 6

All Lines All Lines All s Figure 6 Connecting Jumpered Wires to the The completed star network wiring should look similar to Figure 7. All Lines All Lines All s Figure 7 Multiple Star Spurs Attached to a Master Once the network has been wired, all controllers have been addressed, and the network has been auto-configured by the Doors32 software, the network communication error rate can be viewed from the diagnostics routine in the master controller. Instructions are provided in the Troubleshooting and Diagnostics reference document (p/n 01841-001, Rev. E or greater). Application Note PXL-250 (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 5 of 6

This page is intentionally left blank. PXL-250 Application Note (800) 260-5265 (408) 451-2520 FAX (408) 441-0309 Page 6 of 6