Wideband Optical Splitters FOS Series



Similar documents
4RU High Density Shelf Installation Instructions

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

GSM-EXT Cable Assembly Installation Guide

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

Power Supply Guide Version 1.0 for D-Show

Backup Scanner Module

How To Use The Visifault Visual Fault Locator

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Buffalo, New York Garland, Texas

GIGABIT GATEWAY TECHNOTE

16/32 Channel 1U Rack Mount CCTV Power Supply

DVI DA2 and DVI DA 4 User Guide

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

767 Diagnostic System

Changing the SIM in a BANDIT Product s GSM Card

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

ASKING FOR ASSISTANCE

Tyan Computer. Transport PX22. Service Engineer s Manual

Installing Cisco TelePresence MX200 G2 - Wheel Base

MCR1900 Media Converter 19-Slot Chassis

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Module Connectors and Cable Specifications

Rack Installation Instructions

FUSION R400 RAID USB 3.0

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Serial ATA to Serial ATA

Installing Your 960 or 980 Server into a Rackmount Cabinet

Perle 10/100/1000 Ethernet Media Converter Module

Sun Enterprise Optional Power Sequencer Installation Guide

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Agilent X/P/K281C Adapters

Optical Power Meter. Specification & User Manual

Installation Instructions

Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

About the BitStorm 6051 POTS Splitter

Direct AC Wiring Option Installation Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Measuring of optical output and attenuation

VG4 Fiber Optic Media Converter

Perle Protocol Transparent Media Converter Modules

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

First Data FD130 Terminal. Quick Set-up Guide

Antenna Splitter ASA 1. Instruction manual

About the HotWire Slot Standalone Shelf

Rack installation instructions

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

AU-110 racking guide NBXPN: 023

Perle 10/100 Ethernet Media Converters

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Cable Cubby 1200 and 1400 Installation Guide

HDO700 P FIBRE OPTIC TRANSMITTER

How To Use A Network Instrument Ntap

Removing memory and option cards

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Amphenol Fiber Systems International

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

HP UPS R1500 Generation 3

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

WARNING CANADIAN D.O.C. WARNING

Un-cooled Multimode Pump Laser Module for Telecom Applications

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Raritan LCD KVM Console (T1700/T1900)

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Uninterruptible Power Supply. 500 kva kva

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Regulatory Compliance Statement

DeltaV SISnet Repeater

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

StorTrends 3400 Hardware Guide for Onsite Support

V Installation instructions, accessories. Digital radio DAB. Volvo Car Corporation Gothenburg, Sweden. V70 (08-) 2011 Volvo Cars Europe

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Server Remote Control

HP Port Switches Quick Setup Guide

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

V94 BULK TAPE DEGAUSSER

Hard disk drive mounting bracket Instruction Manual

Remote Deposit Service Online

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

How To Set Up An Inverter

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

HP ProLiant DL165 G7 Server. Installation Instructions

Pretium EDGE HD Solutions

Fiber Optic Distributed Temperature Sensor (B-DTS)

Inspiron 15. Service Manual Series

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Transcription:

Wideband Optical Splitters FOS Series Guide to Installation and Operation M949-9100-103 13 Mar 2014 Miranda Technologies 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com 2014 Miranda Technologies

How to contact us: For technical assistance, please contact the Miranda Technical support centre nearest you: Americas 9:00 am 9:00 pm EST Tel: +1 800 224 7882 Fax: +1 514 335 1614 support@miranda.com France 9:00 am 5:00 pm GMT+1 Tel: +33 1 55 86 87 88 Fax: +33 1 55 86 00 29 Asia 9:30 am 6:00 pm GMT+8 Tel: +852 2539 6987 Fax: +852 2539 0804 asiatech@miranda.com China 9:30 am 6:00 pm GMT+8 Tel: +86 10 5873 1814 Europe, UK, Middle East, Africa 9:00 am 6:00 pm GMT Tel: +44 118 952 3444 Fax: +44 118 952 3401 eurotech@miranda.com (Playout Automation Only) 9:00 am 5:30 pm GMT Tel: +44 8705 004 350 Fax: +44 8705 004 333 Emergency After Hours (worldwide) Tel: 1 800 224 7882 -or- Tel: 1 514 333 1772 and choose menu option 2 eurotech@miranda.com asiatech@miranda.com automationsupport@miranda.com Visit our web site at www.miranda.com Optical Splitters

Table of Contents 1. FOS-series Wideband Optical Splitters... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Available Modules... 2 2 Installation... 3 3 Operation... 4 4 Specifications... 5 Optical Splitters

Optical Splitters

1. FOS-series Wideband Optical Splitters 1.1 Introduction Miranda s optical splitters are wideband, passive and very efficient signal splitters that split an incoming signal on optical fiber into two or more output signals on separate fibers. They function equally well at any bit rate. Models are available for signal distribution, with multiple equal-energy outputs, or for monitoring with a single low-power tap off the main signal. The splitters are packaged in modular form, with all modules the same size, and configured to install in a convenient 1RU tray that holds up to ten modules. 1.2 Features Supports triple 1x2, dual 1x4 and single 1x8 configurations Wideband operation from 1260nm - 1650nm Passive optical splitter design for any bit rate Hot swappable Long distance and high data rate coverage on single mode fiber Equally-distributed optical splitters or monitoring (80/20) optical splitters Convenient 1RU tray for up to 10 Splitter modules Optical Splitters 1

1.3 Available Modules The following modules are available in this series: FOS-T2-50-LC FOS-T2-80/20-LC Triple 1-to-2 (50/50) splitters Triple 1-to-2 (80/20) splitters 3 x 1x2 Splitters FOS-D4-25-LC Double 1-to-4 (25/25/25/25) splitters 2 x 1x4 Splitters FOS-S8-12-LC Single 1-to-8 (8x12.5) splitter 1x8 Splitter 2 Optical Splitters

2 Installation Install the tray into a standard 19 rack using 4 standard rack-mounting screws through the four holes in the corners of the mounting flanges. An available support bracket extending from the front of the tray provides physical support for the fiber cables, minimizing strain on the connectors. Several different configurations are available for the support bracket and mounting flanges, to accommodate different installation set-ups. Slide each module into an empty bay in the tray, and secure it in position with the two captive screws on the front flanges. Optical Splitters 3

3 Operation Warning: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating connector or optical fiber to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. Do not assume laser power is turned off or the fiber is disconnected at the other end. Avertissement: Le rayonnement infrarouge est invisible et peut sérieusement endommager la rétine de l'œil. Ne regardez pas dans l'extrémité d'une fibre active. Un capuchon de protection propre doit être immédiatement placé sur n'importe quel connecteur rayonnant pour fibre optique pour éviter l'exposition à des quantités potentiellement dangereuses de rayonnement. Cette pratique permet également de prévenir la contamination des connecteurs et adaptateurs. Ne présumez pas que la puissance du laser est désactivée ou la fibre est déconnectée à l'autre extrémité. Caution: Class 1M Laser radiation when fiber connector is unplugged. Mise en garde: Rayonnement laser de la classe 1M lorsque le connecteur de fibre est débranché. These optical splitters are entirely passive there is no power connection to the modules. To operate the splitters: 1. Route the appropriate input and output fibers to the location of the optical splitter module. The fibers must have LC connectors, to match the module s sockets. 2. Remove any dust plugs from the optical connectors that you will be using 3. Examine each connector for debris, and clean if necessary 4. Plug the LC connector on the end of the fiber cable into the appropriate connector on the splitter module. Push the fiber connector straight into the module socket until it clicks into place The sockets are labeled to identify inputs and outputs To disconnect a fiber from the module: NEVER pull on the cable itself to disconnect a fiber; ALWAYS grip the connector, push in the release tab and pull straight out ALWAYS place a plug into any unused fiber ports, to keep out dust and debris Notes: 1. Equal ratio splitters (FOS-T2-50-LC, FOS-D4-25-LC or FOS-S8-12-LC) are wideband devices, specified over the full 1260 to 1620 nm spectrum. 2. Unequal ratio splitters (FOS-T2-80/20-LC) are dual windows devices, specified in both the 1260 to 1360 nm and the 1460 to 1620 nm windows. Those splitters aren t completely blind to the 1360 to 1460 nm signals, but they may be slightly out of specifications for that region. Note 80% on OUT 1; 20% on OUT 2 3. The spacing between the LC connectors does not allow the use of duplex fiber cable assemblies with this product 4 Optical Splitters

4 Specifications CONNECTORS LC/UPC female housing OPTICAL FOS-T2-50-LC FOS-D4-25-LC FOS-S8-12-LC FOS-T2-80/20-LC 80% CHANNEL (OUT 1) 20% CHANNEL (OUT 2) Operating Wavelength 1260-1620 nm 1260~1360 nm & 1460~1620 nm Number of Ports 1 input, 2 outputs 1 input, 4 outputs 1 input, 8 outputs 1 input, 2 outputs Insertion Loss with Connector 3.9 db 7.6 db 10.4 db 1.8 db 8.3 db Uniformity 0.8 db 0.8 db 0.8 db NA Return Loss with Connector 50 db MECHANICAL Dimensions: 1 RU tray Length: 5.84 without fiber support 14.25 with fiber support Width: 17.120 tray 18.660 tray plus rack mount brackets Height: 1.728 Weight: 2.4 kg Modules Length: 5.8" module body 6.35 including connector and mounting screws Width: 2.96" module body 3.72 including mounting ears Height: 0.775" Weight: 220g ENVIRONMENTAL Operating Temperature Operating Humidity -40 C to +85 C 95% RH Optical Splitters 5