VEAM PowerLock Box. Interconnect Solutions



Similar documents
Cannon Nemesis Connectors. Interconnect Solutions

PowerLock and SnapLock High Current Power Connectors Catalog

400 Series - Mini USB Buccaneer

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

400 Series Buccaneer BUCCANEER POWER. bulgin

SOURIAU s discrete wire sealing

CONEC SnapLock. 1 Introduction

Motion picture, radio, and television equipment, serving laughter and entertainment to millions.

Glenair Military and Industrial Power and Signal Connectors

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Mini USB and USB 2.0-IP67 Connector System

AC SERIES DUAL 1/4 (6.35mm) / XLR

PowerLine. Single Pole Connectors

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

7000 Series Buccaneer

Standard Buccaneer - Ethernet

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Standard Buccaneer - USB

6000 Series Buccaneer

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

AC SERIES-C TYPE DUAL CONNECTORS JACK/XLR

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

MCR1900 Media Converter 19-Slot Chassis

Advantium 2 Plus Alarm

FIREDEX Conventional Fire Panels

How To Build A Powerline Box Powerline Generator

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

A&C Solutions: please contact us.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Plastic-Shelled Waterproof Connectors for Outdoor Use

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

IEC Connectors. Introduction

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Unit 24: Applications of Pneumatics and Hydraulics

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Maestro Processor Backup Battery, CP Server, and CP FPGA Upgrade

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

8146/5 Series Breaker Panelboards

AXIS 291 1U Video Server Rack Installation Guide

IFS SP-PoE Splitter User Manual

EC DECLARATION OF CONFORMITY FOR MACHINES

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

VOYAGER 570G. 744A Sprayer Control

Rack Cabinets. Rack Configuration. 19 inch

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Installation & Operation Manual. Type 1801 External Seahorse Pantograph Wiper. without Control System

Compact pressure switch Flameproof enclosure Ex d Model PCA

UTS discrete wire sealing

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Assembly Instruction CAI- Connector with universal Endbell

Anderson Power Products

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Home Signal Distribution Kit for Satellite TV Plus SIRIUS

Directory chapter 04

Proportional pressure regulators VPPE

Wireless Router Setup Manual

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

The Wild Children of D38999

CU-950 Installation Guide

08. SEK IDC CONNECTORS

EPIC CIRCON M23 Series Circular Signal Connectors

AXIS T81B22 DC 30W Midspan

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

BX7000 Multi-Access Gateway Getting Started Guide

I STAR COMPUTER CO., LTD

Agilent 87421A/87422A Power Supply

Indoor / Outdoor Antenna

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Applications SS 26 V- R

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

Source Four Mini LED Gallery: 90+ CRI ETC. Source Four Mini Series. General information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

picomax The Pluggable Connection System

GAE953 Electrical Alarm Unit 19" with Indicator

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

Quick Reference Guide Euro Style Terminal Blocks

DVI DA2 and DVI DA 4 User Guide

Agilent 4339B/4349B High Resistance Meters

Transcription:

VEAM PowerLock Box Interconnect Solutions

Features & Benefits Following the highly successful ITT Veam NRG Box, the new PowerLock Box offers an economical option with many of the same functions contained within a facia profile that is reduced by 50%. For use in low voltage networks (1500 volt DC), and capable of handling a continuous current of up to 660 amps, the PowerLock Box, with patented sequential connecting system, comes in a 19" x 2U rack mounting format that guarantees the correct sequence of connecting and disconnecting a set of PowerLock connectors (Ground, Neutral, Line 1, Line 2 & Line 3) is followed. Connect with standard Powerlock connectors Sequential connecting ensures Ground/Earth is connected first 400 amp & 660 amp continuous current options Source and Drain (Power out or Power in) options Environmentally sealed to IP65 All ports keyed to prevent incorrect connection Sealed Security lid optional IP2X Finger protected Lock to prevent interference Colour coded to suit European, North American, and Australian 3 phase standards Operation of the PowerLock Box Each connector port has an M12 threaded post with nut and spring washer on the rear for the fixed cabling of the PowerLock Box. In addition there is a 2 pole connector on the rear of the box, connected to a micro-switch that is activated once all cable connectors are inserted into PowerLock Box. The box is then operated as follows: For a box fitted with a sealed lid, first unlock the lid using the key provided, for the un-lidded go straight to the next step Insert the Ground/Earth connector into the green port on the left and turn 45 to the right to lock Insert in sequence, from left to right, the Neutral followed by the 3 phases Once the Line 3 connector is in place, using the key provided, lock the box as indicated on the front panel The box is now connected and ready to be powered up Never attempt to uncouple the connectors whilst under load.

Technical overview The PowerLock Box is designed for use in high current applications and offers many safety and security benefits when compared with a set of individual connectors. Performance Current rating Voltage rating Contact material Housing material Endurance Environmental protection Electrical protection Flammability rating Operating temperature Colour coding RoHS & WEEE Safety notice 400 amp or 660 amp continuous 1000V AC / 1500V DC Brass (400 amp) or high conductivity Copper (660 amp), silver plated High temperature thermoplastic 500 connection cycles Un-lidded version IP65 when connectors are fitted Lidded version IP65 with lid locked or when connectors are fitted IP2X (finger safe) UL94-V0-30ºC to +85ºC European, North American & Australian 3 phase colour coding Compliant The PowerLock Box should only be installed and operated by suitably qualified persons

Ordering information PBX XX XX XX XXX Box type SL = Sealed Lid NL = No Lid Contact type PS = Source PD = Drain Regional colour code EU = Europe US = North American AU = Australia Power rating 400 = 400 amp 660 = 660 amp Example A 660 amp box with a sealed lid and Drain contacts with European colour coding is: PBX-SL-PD-EU-660 Powerlock connectors available in colours to suit regional colour coding systems. With Crimp or Set-Screw contacts to suit copper and aluminium cables up to 300mm 2. Snaplock 250 amp connectors available with either crimp or set screw contacts are smaller and suitable for lower current applications. NRG Box (4U high) and PowerLock Box (2U high) For more information on the range of PowerLock connectors and accessories, see our catalogue at or call your nearest ITT Interconnect Solutions office

Applications Why use the PowerLock Box? Whenever you need to link a generator into a low voltage network, the PowerLock Box offers a safe and convenient system, indoors or outdoors, there is a PowerLock Box to suit your needs. All Powerlock devices are keyed to eliminate the possibility of connecting with the wrong line. When all connectors are correctly fitted to the PowerLock Box, the unit can be locked to prevent unauthorised disconnection. This lock also activates a micro-switch that is connected to a 2 pin connector on the back of the unit that can be connected to a circuit breaker or alarm circuit for additional safety. Keep running during planned power outages Bring in a generator during an emergency, connect to the PowerLock Box and you are quickly up and running again Typical uses include Mobile Generators Outdoor events Welding equipment Residential estates Dockside/Riverside power plant Theatres Theme park rides Factories & Shops Hospitals Hotels & Offices Apartment blocks Alternative energy installations Holiday complexes When ever you need a flexible source of low voltage power, with a PowerLock Box installed, you have a safe and secure connection point. The ITT Veam NRG box was introduced in 1999 and has been successfully deployed in installations throughout the world. Now the PowerLock Box builds on that experience with a more compact unit.

Customer Support Locations CHINA Tuopandun Industrial Area, Jinda Cheng, Xiner Village, Shajing Town, Baoan District, Shenzhen City, Guangdong, China 518125 phone: +86.755.2726.7238 fax: +86.755.2726.7515 GERMANY Cannonstrasse 1 Weinstadt, 71384 phone: +49.7151.699.0 fax: +49.7151.699.217 FRANCE 15, Boulevard Robert Thiboust Serris, France 77700 phone: +33.1.60.04.93.93 fax: +33.1.60.04.93.90 HONG KONG Units 2405-6, 24/F, ING Tower 308 Des Voeux Road Central Hong Kong phone: +852.2732.2720 fax: +852.2732.2919 ITALY Corso Europa 41/43 Lainate (MI), Italy 20020 phone: +39.02938721 fax: +39.0293872300 JAPAN 11-3, 5 Chome,Hibarigaoka, Zama-shi Kanagawa, Japan 228-0003 phone: +81.462.57.2010 fax: +81.462.57.1680 UK Jays Close, Viables Estate Basingstoke, RG22 4BA phone: +44.1256.311200 fax: +44.1256.323356 USA 100 New Wood Road Watertown, CT 06795 phone: +1.860.274.9681 fax: +1.860.274.4963 2008 ITT Corporation. Engineered for life and Cannon are registered trademarks of ITT Corporation. Specification and other data are based on information available at the time of printing, and are subject to change without notice.