Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: Application Note 51270 (Revision NEW, 11/2005) Original Instructions



Similar documents
EGCP-3 LS Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294

EGCP-3 MC Revision H Software Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298

Network Attached Storage System Recovery Procedure

Upgrade Guide. Platform Compatibility. Dell Secure Mobile Access Upgrade Guide

Plena Voice Alarm System Firmware update

Vicon Flash Upgrade Software

Vicon Flash Upgrade Software

EDI Distributor Control Interface Wiring and Setup Instructions

DataLINE Data Retrieval

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Application Note (Revision A) Original Instructions. Visual C++ Installation

File Management Utility. T u t o r i a l

Digital Controllers ACTUATOR COMPATABILITY

DCS DCS 6000 Digital Conference System Firmware Upgrade & Feature License Key Manual. Upgrade Manual. Digital Conference System

Intel Matrix Storage Console

Updating MNS-6K software on Magnum 6K Switches

Multi-Master DF1 Protocol User Guide

Upgrade your Software

IPMI Firmware Update (AMI) In WEB-GUI/DOS/WIN/Linux

H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

Honeywell Internet Connection Module

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Shearwater Research Dive Computer Software Manual

APNT#1168 Modbus - Establishing Communications Hints

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

File Transfers. Contents

FortiOS Handbook - Hardening your FortiGate VERSION 5.2.3

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

Release Notes: PowerChute plus for Windows 95 and Windows 98

Polycom CMA System Upgrade Guide

Basic Router and Switch Instructions (Cisco Devices)

Model 288B Charge Plate Graphing Software Operators Guide

INSTRUCTION MANUAL. Installing the Software NO. XX NOTES Refer to XX134 REV. 510 SEC. 3

The Helios Microsoft Windows Server

LifeSize Networker Installation Guide

Universal Serial Bus Implementers Forum EHCI and xhci High-speed Electrical Test Tool Setup Instruction

Converting SSG 300M-series and SSG 500M-series Security Devices to J-series Services Routers with a USB Storage Device

File Transfers. Contents

If anything is damaged or missing, contact your dealer.

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Quick Start Guide FLIR Firmware Update Tool

Motorola Phone Tools. Quick Start

Modbus RTU (RS-485) TCP/IP (Ethernet)

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

Software Release Notice Rev A

Centurion C4 Transfer Guide using C4 File Transfer Utility

Device Installer User Guide

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Controller Automation, Model II+

Application/Connection Examples

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

4 Networking Generators

Gauge Drawing Tool Slider Drawing Tool Toggle Button Drawing Tool One-Way List Drawing Tool... 8

AT89C5131A Starter Kit... Software User Guide

In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM

ReadyNAS OS 6 Desktop Storage Systems

User Manual. Thermo Scientific Orion

Modbus Communications for PanelView Terminals

How to downgrade Samsung Galaxy Tab 2 back to original V4.1.1 Android OS

N300 WiFi Range Extender

SFTP Server User Login Instructions. Open Internet explorer and enter the following url:

Supplemental User Guide

KVM-1501/ KVM-1508/ KVM-1516 KVM-1701/ KVM-1708/ KVM-1716 USER MANUAL

SecureLinx Spider Duo Quick Start Guide

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

GSC/VRC IP Converter. Installation and Operation Manual

Starting a Management Session

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

IP Office Essential Edition IP Office Essential Edition - Quick Version Phone Based Administration

Kurz MODBUS Client User s Guide

TFTP Firmware upgrade

IP Office Basic Edition IP Office Basic Edition - Quick Mode Phone Based Administration

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Parallels Virtuozzo Containers 4.6 for Windows

VTO6xxx. IP door stations. User manual

INSTALLING AND USING ENTEL PROGRAMMER IN WINDOWS 7 Technical Support Bulletin

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

USB External Hard Disk Drive

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Intel Matrix Storage Manager 8.x

Hydras 3 LT Quick Start

Intel Dialogic System Release 6.1 CompactPCI for Windows

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Axel Remote Management

PowerPanel Business Edition USER MANUAL

Intel Rapid Storage Technology

Temperature & Humidity SMS Alert Controller


SETX SFX Dial-Up Program

Guide to Installing BBL Crystal MIND on Windows 7

Infiniium Upgrade and Recovery Guide

Digi Connect Wan 3G Application Guide Update the firmware, backup and restore the configuration of a Digi Connect Wan 3G using a USB flash drive.

CALL MANAGER INSTALLATION

Dell NetVault Bare Metal Recovery User s Guide

Transcription:

Application Note 51270 (Revision NEW, 11/2005) Original Instructions Software Upgrade Instructions for Field Conversion of EGCP-2 Controls: 8406-120 A, B, C, D, E, and F to 8406-120 G 8406-121 A, B, C, D, E, F, and G to 8406-121 H 8406-123 New, A, and B to 8406-123 C Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless otherwise expressly undertaken. Copyright Woodward 2005 All Rights Reserved

EGCP-2 Software Upgrade Kit Application Note 51270 EGCP-2 Software Upgrade Kit Download the latest software for controls 8406-120, -121, -123 Introduction Woodward is releasing application software 149G_app.hex for upgrading existing EGCP-2 controls in the field. This application note explains how to download the software and describes all the changes made in the software. The software can be used to upgrade only these existing controls. 8406-120 A, B, C, D, E, or F can be upgraded to 8406-120 G o Upgrades software 5418-149 A, B, C, D, E or F to 5418-149 G. 8406-121 A, B, C, D, E, F, or G can be upgraded to 8406-121 H o Upgrades software 5418-149 A, B, C, D, E, or F to 5418-149 G. 8406-123 New, A, or B can be upgraded to 8406-123 C o Upgrades software 5418-149 D, E, or F to 5418-149 G. Woodward recommends that all existing stock be upgraded. This is only an Application software upgrade, 149G_app.hex, and will not affect any of your configuration or calibration settings. The download takes approximately 14 minutes. A Communication Cable, Woodward part number 5417-551, can be used to download the new software. NEW EGCP-2 PART NUMBERS 8406-120 8406-121 8406-123 DESCRIPTION 150 300 Vac PT 50 150 Vac PT 50 150 Vac PT INSTALLATION & OPERATION APPLICATION COMMUNICATIO N SECURITY LEVELS 26174 26175 26181 26108 26174 26175 26181 26108 26174 26175 26181 26108 Description of Software Changes 1. Loss of Start_All command caused by removing the Auto discrete input of the Master EGCP-2 while the Engine Control state is in the Run mode a. Present software - Configuration of the Auto Sequencing setting i. Enabled 1. The Start_All command can be left in a false state if the Master unit has the Auto discrete input removed after sequencing a slave unit off. The EGCP-2 must be in an Engine Control state of Run when Auto is removed. 2. This would result in the Master unit not issuing a Start_All command on the next Loss of Mains event. In a multiple generator standby application this would cause only the Master to start, no Slave units would start. ii. Disabled 1. The Start_All command can only be left in a false state if the Master unit has the Auto discrete input removed within a 200-millisecond window of the Mains Aux Feedback being received. 2 Woodward

Application Note 51270 EGCP-2 Software Upgrade Kit b. New software - The Start_All command is now reset when the Auto discrete input is opened. i. Reference Service Bulletin 01361 2. Unexpected Reboot when generator set is decelerating, Spindown mode a. Present software This can only occur on engines that are decelerating at 1 hertz per second or slower. The EGCP-2 would reboot when going through the 21.35 to 21.50 hertz range. The EGCP-2 will be in the Spindown mode at this time. i. A parameter was found to be out of range causing an excessive interrupt rate on the processor. This prevented the toggling of a watchdog timer, which timed out and reset the processor. b. New software - The parameter is now limited to prevent excessive interrupts from happening. i. The applications were tested at 50 and 60-hertz settings, from 10 to 120 hertz, at a rate of 0.25 hertz per second. Description of New Boot Code 2.0 Changes The Boot code was changed from version 1.1 to version 2.0. The new Boot code was released in June of 2005. 8406-120 Rev F, Application software 5418-149 Rev F 8406-121 Rev G, Application software 5418-149 Rev F 8406-123 Rev B, Application software 5418-149 Rev F Boot code 2.0 will allow the EGCP-2 to boot up even with a Modbus * signal present on the 422 port. The previous boot code would lock up while in the boot up phase if a Modbus signal were present. * Modbus is a trademark of Modicon, Inc. The EGCP-2 will go through a boot up phase whenever power is cycled. The Boot code number appears on the left display for 2 to 3 seconds while booting up. The Boot code 2.0 CANNOT be downloaded in the field. If you wish to have a control upgraded there are two options: 1. Contact your Woodward customer service representative for a return authorization number (RAN) and return the unit(s) to Woodward 2. If a return is not feasible, contact your Woodward customer service representative to discuss the availability of replacement/exchange unit(s). Compatibility with Existing Controls The new software, 5418-149 G, will operate with all existing EGCP-2 and EGCP-1 controls. Download Instructions This section provides instructions for downloading the 149G_app.hex software needed to upgrade the 8406-120, -121 or -123 controls. The software in the control after the download will now be 5418-149 Rev G. Loading the Application software will not affect any Configuration or Calibration set points. An unsafe condition could occur with improper use of these software tools. Only trained personnel should have access to these tools. Woodward 3

EGCP-2 Software Upgrade Kit Application Note 51270 Downloading the 149G_app.hex Software Requirements EGCP Download Cable, Woodward part number 5417-551 (includes RS-232 RS-422 converter) or equivalent. Download_d.exe, part number 9926-113 Rev B or greater (download_d is a DOS-based freeware program that can upload and download configuration files through the RS-422 serial port on the EGCP-2. This program is available on the Woodward website at: www.woodward.com/software. Select EGCP-2 Tools, then Go. Download the EGCP Download Program. The Download_D.exe file should be saved on your hard drive (C:/). It is suggested to save it in a directory labeled EGCP2. Instructions In the following example, showing the 149G_app.hex, the file is saved in a directory called EGCP2 on the C:\ drive. Store the EGCP-2 software files in the same location. Software 149G_app.hex The EGCP-2 control that is being upgraded will have software 5418-149 already loaded. To view the software number that is programmed in the EGCP-2 control, press the CONFIG key and then press the ENTER key. The software can be Rev A, B, C, D, E, or F. Here s an example of a control installed with 5418-149 Rev C software. Using a DOS command prompt, go to the directory where the download_d.exe file is stored and type download_d h (or?) for a complete list of the command-line options. 4 Woodward

Application Note 51270 EGCP-2 Software Upgrade Kit Establishing a Connection: Connect the RS-232 / RS-422 cable between the EGCP-2 and the computer. Only one EGCP-2 can be connected to the RS-422 communication network when uploading or downloading set points. If a multidrop network has been set up (linking more than one EGCP-2 on the RS- 422 communication port network), it will be necessary to separate the control from the network in order to upload or download. Downloading 149G_app.hex file from the Computer to the Control: Using a DOS command prompt, go to the directory where the download_d.exe file is stored and type "download_d 149G_app.hex" at the DOS command prompt (see below). When the message appears as in the example below complete steps 1-6, (examples show 149E_app.hex). 1. Cycle power to the EGCP-2. 2. When the power is restored to the control, the download will begin. 3. On the EGCP-2s left screen, the text APPLICATION will be displayed. 4. A scroll bar will appear on the computer screen showing the progress of the download. Woodward 5

EGCP-2 Software Upgrade Kit Application Note 51270 5. After the download is complete, the control is ready to operate. The set points and calibration adjustments have not been changed. 6. The EGCP-2 will display software part number, 5418-149 Rev G. We appreciate your comments about the content of our publications. Send comments to: icinfo@woodward.com Please reference publication 51270. PO Box 1519, Fort Collins CO 80522-1519, USA 1000 East Drake Road, Fort Collins CO 80525, USA Phone +1 (970) 482-5811 Fax +1 (970) 498-3058 Email and Website www.woodward.com Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address / phone / fax / email information for all locations is available on our website. 6 Woodward