DataLINE Data Retrieval
|
|
- Sandra Benson
- 8 years ago
- Views:
Transcription
1 Container Refrigeration INSTALLATION GUIDE for DataLINE Data Retrieval Rev B
2 INSTALLATION GUIDE CONTAINER REFRIGERATION UNIT DataLINE Data Retrieval
3 CONTENTS Paragraph Number Page 1. Introduction Version Support PC Requirements Installation and Start Up Procedures Windows 95/98/NT/XP Installation Service Pack Installation Initial Start Up Procedure Install USB to Serial Adaptor Change Settings Main Features Program Options Interrogate System Tools Probe Calibration Monitor Download Files Data Set View Data (Report Generation) Data Manager Help... 21
4 1. Introduction This guide has been prepared for users of the DataLINE PC software. It provides an overview of the following: PC system configuration requirements Program installation procedures Main features Help This User s Guide is written for users familiar with working in the Windows Operating System, including Windows 95, Windows 98, Windows XP and Windows NT. Operating Instructions for DataLINE are available in the Literature\Manuals section of the Carrier Transicold web site at NOTE: Not all PROGRAM OPTIONS are available. When they become available future service pack upgrades can be obtained free of charge at 2. Version Support The DataLINE software will support ML2, ML2i, ML2i cs (Scroll), ML2/2i CA (Controlled Atmosphere), and ML3 units. Note: Data from Microlink 1 (ML1) units must be retrieved using the Carrier DataReader hand held device (P/N ). DataLINE can then be used to transfer the data from the DataReader to a P.C. TABLE 1 DataLINE Software PART NUMBER DESCRIPTION APPLICATION ## DataLINE Software CD PC/Windows Updates to the software will be posted on the Carrier Transicold web site as new versions are released. These updates are called Service Packs. To protect software ownership, a Service Pack can only be loaded onto a P.C. that already has the DataLINE software installed
5 3. PC Requirements Table 2 PC Requirements Minimum PC System Configuration Processor 486 Pentium Operating System Windows 95, 98SE, NT 4.0 or higher, Windows XP Version 3.0 or higher Recommended PC System Configuration Internet Explorer RAM 8MB 16MB Hard Drive 30MB (Free Space) Disk Drive CD ROM Video VGA Video Resolution 640X x600 or higher Serial Port One RS 232 port (Com 1 or 2 only) 1 RS 232 Printer Port None Printers supported by Windows 95, 98SE, NT & XP Using a PC with at least the recommended system configuration will provide the best overall performance of the DataLINE software. 4. Installation and Start Up Procedures 4.1 Windows 95/98/NT/XP Installation The DataLINE application is delivered to users on CDROM. All Users To begin installation of the DataLINE application, perform the following: 1. Place the DataLINE CD in the CD drive. 2. The primary method for loading the program is to access the appropriate drive and double click on the Setup.exe file. The application installation screen is automatically launched
6 An alternative method for loading the program is to click on the Start button and then click on Run to display following the Run screen. Enter the path name for the appropriate drive as instructed, e.g. D:\Setup.exe with D representing the CD drive. Click OK to launch the application installation screen. Windows 95 Users Only The application will search for the presence of DCOM95 (an update to the operating system) on the PC. If DCOM95 is not found, the user is prompted with the following screen
7 The user should click OK to begin the installation of DCOM95. After DCOM95 has been installed, the following screen is displayed prompting the user to reboot the PC. The user should click OK to begin the reboot. All Users The user should perform the following tasks to complete setup and installation of the application. The Welcome screen is displayed to begin setup of the application
8 Click Next to display the Language screen. The default language is English. Click Next to display the Choose Destination Location screen. The user can specify into which directory the system should store the application. The default directory is C:\DataLine. The user can click on the Browse button to choose an alternate directory
9 Click Next to display the Select Program Manager Group screen. The user can manually enter a name for the program, which appears on the desktop, or use the default name of DataLine. Click Next to display the Start Installation screen
10 Click Next to start the installation of the application. NOTE: If an association does not exist between the DCX file and any application, the following DCX File Registry screen is displayed before the Installation Complete screen. The user is alerted and asked if they want to automatically create the association. Click Yes to create the association. Click Finish to complete the installation
11 After the installation is complete, the following screen appears. In order for DataLINE to operate properly, it is recommended that the user restart the computer. Click OK to restart the computer. 4.2 Service Pack Installation In order to install the service pack, the user MUST already have DataLINE installed on the computer. The most recent Service Pack for DataLINE can be downloaded at Products\Software\DataLINE. If a previous version of DataLINE is not installed, the following screen is displayed. Click OK and the installation will abort
12 If a previous version of DataLINE is installed, the Welcome screen is displayed to begin setup of the application. Click Next to display the Start Installation screen. Click Next to start the installation of the application
13 NOTE: If an association does not exist between the DCX file and any application, the DCX file registry screen is displayed before the Installation Complete screen. The user is alerted and asked if they want to automatically create the association. Click Yes to create the association. While the service pack is installing, the following Installing screen is launched
14 When DataLINE has successfully installed, the following Installation Complete screen is launched. Click Finish to the complete service pack installation. After the installation is complete, the following screen appears. In order for DataLINE to operate properly, it is recommended that the user restart the computer. Click OK to restart the computer
15 4.3 Initial Start Up Procedure On initial start up, the installer should set the Program Options to be used in this application. To start the DataLINE application and set the options, do the following: 1. Click on the Start button 2. Highlight Programs 3. Highlight DataLINE 4. Click on Launch Pad ( ViewData is selected to generate reports using data files that have previously been stored in the P.C.) The following Launch Pad screen is displayed when the DataLINE application is started. The Application Launch Pad is the user s entry point into the DataLINE program. INTERROGATOR SYSTEM TOOLS MONITOR PROBE CALIBRATION DOWNLOAD FILES DATA SET VIEW DATA DATA MANAGER PROGRAM OPTIONS DATALINE HELP CONTENTS EXIT DATALINE ABOUT DATALINE When the cursor is moved over each button, the name of the feature associated with that button is displayed. Clicking on a button will launch the feature. Each feature is described in Section
16 4.4 Install USB to Serial Adaptor For computers without an available serial port (RS 232) a USB to serial adaptor is available through Carrier Transicold Performance Parts group, part number , Keyspan adaptor. To use the Keyspan adaptor, the Carrier USB driver setupdl_usb.exe must be installed. This driver is provided on the CD that comes with the Keyspan adaptor: NOTE: Before installing the Carrier USB driver, make sure that there are no versions of USB to serial drivers currently installed. To check, go to Start\Settings\Control Panel\System\Add or Remove Programs to verify and remove any currently installed USB to serial drivers. 1. If DataLINE version 1.0 software is not currently installed, install it. 2. Upgrade to the latest DataLINE Service Pack. Service Pack upgrades for DataLINE are available for download at Products\Software\DataLINE. NOTE: Do not insert the Keyspan adaptor in the USB port until the Carrier USB driver is installed. 3. Insert the Keyspan installation CD into the CD Drive and double click the USB to serial driver SetupDL_USB.exe. Follow the on screen commands to properly load the driver. 4. Restart your system. 5. After system restart, insert the Keyspan adaptor into an open USB port; allow the computer a moment to recognize the Keyspan adaptor. NOTE: Always insert the Keyspan adaptor in the same USB port
17 6. Check to make sure the Keyspan adaptor is properly installed by opening the Windows Device Manager, Start\Settings\Control Panel\System\Hardware\Device manager\ports: Make sure Keyspan USB Serial Port is assigned to COM3. If not, double click the Keyspan USB Serial Port to open the properties window. Click Advanced... and reset to COM Port
18 7. From Windows Explorer, open C:\Common Files\Carrier Shared\USB and click the driverconfig file, the following screen will appear: 8. Select Keyspan USB Port (COM3) and click configure, it should now read Driver installed for the device. 9. Click the Test button, the Success window should appear: NOTE: If the Success window does not appear, disconnect and then reconnect the Keyspan adaptor. Always connect the Keyspan adaptor to the same USB port. Click the Test button again. 10.Open DataLINE and go to the Program options menu (Globe button), select COM3, Save and Exit. DataLINE should now be ready for communication through the USB Keyspan Adaptor
19 4.5 Change Settings The user can change settings at any time using the Program Options screen, and the application remembers the settings from one execution of the program to the next. Any changes made to the settings are reflected in the Interrogator screen within 30 seconds of the user saving the change. To launch the Program Options screen, Click on the PROGRAM OPTIONS button (globe) in the Launch Pad. Select the Com Port: If the Interrogator does not connect using Com1, try changing to Com2 or changing the physical connection at the back of the PC. For those computers fitted with an Infrared Port, there may be a conflict between the Infrared Port and the Com Port used by DataLINE for communication. If there is a conflict, then interrogation of the unit will not be possible. If DataLINE is using COM1, then the Infrared Port cannot be set to COM1 or COM3. If DataLINE is using COM2, then the Infrared Port cannot be set to COM2 or COM4. Many PC s only have one Com Port
20 The best way to avoid a conflict is to disable the Infrared Port. The Infrared Port is typically disabled using the BIOS (Basic Input Output System) on the PC, and may also need to be disabled using the Control Panel utility in Windows. CAUTION Changes to the BIOS should only be attempted by trained personnel. Failure to properly configure the BIOS can lead to a loss of system operation. For help disabling the Infrared Port, please contact your qualified local Information Systems (IS) representative, or PC manufacturer. Select the Working Directory: This feature is used to specify the directory to which all downloaded interrogation data will be stored. The user can manually change the directory by entering the directory path in the list box. Users can also change the directory by clicking on the Browse button in the Working Directory Group Box. The Select Directory screen is displayed and users can specify the path of the directory where the application should store the data. The default directory is <DataLine Install Path>\Datafile. The user cannot download data to any removable storage medium (e.g. floppy disks). The working directory should be a local drive on the user s PC or a network drive mapped to the user s PC. The application does not automatically move data stored from the previous working directory into the newly specified working directory. The user must manually move the previously stored data to the new directory via the PC s file system. Select Report Directory: This feature is used to specify the directory to which all reports will be stored. The user can manually change the directory by entering the directory path in the list box. Users can also change the directory by clicking on the Browse button in the Report Directory Group Box. The Select Directory screen is displayed and users can specify the path of the directory where the application should store the data. The default directory is <DataLine Install Path>\Reports. The user cannot download data to any removable storage medium (e.g. floppy disks). The report directory should be a local drive on the user s PC or a network drive mapped to the user s PC. The application does not automatically move data stored from the previous report directory into the newly specified report directory. The user must manually move the previously stored data to the new directory via the PC s file system
21 Select Temperature Units: This feature is used to specify the temperature units in which the temperature data appears on the application screen. The application uses this setting to convert temperature data to the proper temperature units and display it on the screen as well as in reports. The setting also effects the display of pressure values in the Monitor utility. Select Date Format: This feature is used to to specify the format in which the date appears on the application screen. The application uses this setting to only control the appearance of the DataLINE screens. This completes the Program Option set up procedure. The DataLINE software and PC are now ready for use. 5. Main Features A brief description of the DataLINE features is provided in the following sub paragraphs. 5.1 Program Options This feature allows the user to configure the following program options: 1. Com Port Selects the Com Port that will be used to communicate with the refrigeration unit or the DataReader. 2. Date Format Selects the format in which all dates will be displayed 3. Temperature Selects the units in which all temperature values will be displayed. 4. Working Directory Identifies the directory into which all downloaded interrogation data will be stored. 5. Report Directory Identifies the directory into which all reports will be stored. 5.2 Interrogate This feature allows the user to extract sensor, event, alarm, pre trip test, and probe calibration data from the DataCORDER by connecting a PC to the refrigeration unit. There are four options for extracting this data: 1. By Trip 2. By Date 3. Last 30 Days 4. All Data
22 5.3 System Tools This set of features will allow the user to: 1. View/Edit the Container ID number. 2. View/Edit the following controller information: Controller Setpoint Compressor Hour Meter value 3. View/Modify the current configuration of the controller: The controller can be configured using one of the OEM configurations A custom configuration can be created and saved by modifying one of the OEM configurations, or by modifying a previously created custom configuration. 4. View/Edit the following Controller Parameters: Defrost Interval In Range Band Current Limit Units (temperature) Stagger Start Shutdown Mode 5. View/Modify the DataCORDER Configuration: The DataCORDER can be configured using one of the OEM configurations (for ML2i and ML2i cs units only). A custom configuration can be created and saved by modifying one of the OEM configurations, or by modifying a previously created custom configuration. View/Edit the DataCORDER Date/Time. The DataCORDER Date/Time can be synchronized with the PC Date/Time. Start a new trip (with or without a USDA trip comment). Modify the ISO Trip Header. 5.4 Probe Calibration This feature allows the user to calibrate the USDA and Cargo probes using one of the following methods: 1. Auto Calibration The DataCORDER will automatically calculate the proper offsets of the selected probes from a fixed ice bath temperature of C, and calibrate with these offsets
23 2. Internal Calibration The user selects a fixed ice bath temperature between and C that applies to all probes. The Data- CORDER will then calculate the difference between the selected bath temperature and the actual bath temperature, and set the offsets of the selected probes to those values. 3. External Calibration The user will specify the offset of each probe to be calibrated. The user must confirm that the actual probe readings (with offset) match the corresponding ice bath temperature for that probe. 5.5 Monitor This feature allows the user to monitor the status of the refrigeration unit s analog inputs (sensors), and discrete Inputs/Outputs (switches, protectors, component status). The Set Point and the percent opening of the SMV can also be monitored. 5.6 Download Files This feature allows the user to download interrogation files from the DataReader to the PC (this feature is also called DataReader Download). 5.7 Data Set This feature allows the user to define and upload configuration files from the PC to the DataReader, and also to download configuration files from the DataReader to the PC. The user also has the ability to modify or delete container configurations that are stored on the DataReader or PC. 5.8 View Data (Report Generation) This feature allows the user to generate, preview, and print reports using the data extracted by interrogating the DataCORDER. There are seven standard reports that may be generated. 1. Alarm Summary Report will display the controller, DataCORD- ER, and CA alarms over a selectable range of dates. 2. Event Report will display the event data over a selectable range of dates. 3. Sensor Report will display the sensor data over a selectable range of dates. 4. Cold Treatment Summary Report will display the activity of the USDA sensors with respect to their operation within predefined temperature ranges. 5. Controller Pretrip Report will display the pre trip results over a selectable range of dates
24 6. Raw Data Report will display the event and sensor data over a selectable range of dates. This report will also display sensor configuration information. 7. Graphical Report will allow the user to view sensor data over a selectable range of dates in a graphical format. A custom report template can be created using the following standard reports. These templates can then be used to generate reports using extracted data. 1. Alarm Summary Report 2. Event Report 3. Sensor Report 4. Graphical Report 5.9 Data Manager A data management system for DCX interrogation files. 6. Help On-line help is available on each screen of the DataLINE program. Each screen contains a help button. Pressing the F1 key will also start on-line help. This feature is presented in the standard Windows help format, including contents, index and find options. Operating Instructions for DataLINE are available in the Literature section of the Carrier Transicold web site
25 Carrier Transicold Division, Carrier Corporation Truck/Trailer Products Group P.O. Box 4805 Syracuse, N.Y U.S A A member of the United Technologies Corporation family. Stock symbol UTX 2011 Carrier Corporation Printed in USA 0611
File Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
More informationKorosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
More informationSOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
More informationUser Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
More informationCOMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
More informationSTATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS
data analysis data mining quality improvement web-based analytics Notes STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS 1. The installation of the Concurrent network
More informationAnalyzer 2.0. Installation Guide. Contents
Analyzer 2.0 Analyzer 2.0 is a comprehensive suite of tools designed to help you analyze complex aqueous and multisolvent electrolyte solution chemistry, thermophysical properties, phase behavior and corrosion
More informationSTATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable
More informationWindows 98 Workstation Install
Windows 98 Workstation Install To install the Oracle Client Software on a Windows 98 workstation you need to do a manual install installing the Oracle Client Software first then the Infinitime software.
More informationGUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 info@guard1.com www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
More informationMotorola Phone Tools. Quick Start
Motorola Phone Tools Quick Start Contents Minimum Requirements...2 Before Installing Motorola Phone Tools...3 Installing Motorola Phone Tools...4 Mobile Device Installation and Configuration...5 Online
More informationCashFlow Programming Module CPM
CashFlow Programming Module CPM Installation & User Guide GB REV G4 08/08/2006 Table of Content Table of Content... 2 CashFlow Programming Module (CPM)... 4 What is a CPM?... 4 CPM Identification... 4
More informationChapter 3 Software Installation
Software Installation Chapter 3 Software Installation This chapter provides information on how to install the CyberSerial PCI s drivers and utilities for the following operating systems: Windows 95/98
More informationBioWin Network Installation
BioWin Network Installation Introduction This document outlines procedures and options for installing the network version of BioWin. There are two parts to the network version installation: 1. The installation
More informationInstallation Instruction STATISTICA Enterprise Small Business
Installation Instruction STATISTICA Enterprise Small Business Notes: ❶ The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b) workstation installations
More informationJEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP
AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,
More informationGuide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
More informationBillQuick Agent 2010 Getting Started Guide
Time Billing and Project Management Software Built With Your Industry Knowledge BillQuick Agent 2010 Getting Started Guide BQE Software, Inc. 2601 Airport Drive Suite 380 Torrance CA 90505 Support: (310)
More informationOFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES
OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES Thank you for purchasing OFFICE KEYBOARD. This User s manual contains all information that helps you to operate your keyboard. Please keep the software
More informationSAS 9.1.3 Installation Instructions Windows 2003, XP, 2000, NT. SAS 9.1.3 Client Server Installation. Introduction:
UCit Instructional and Research Computing, Software Distribution Office, 303B Zimmer Hall, Cincinnati, OH 45221-0088. Phone: (513) 556 9068 Email: Software@uc.edu SAS 9.1.3 Installation Instructions Windows
More informationBioWin Network Installation
BioWin Network Installation Introduction This document outlines the procedures for installing the network version of BioWin. There are three parts to the network version installation: 1. The installation
More informationRichmond Systems. SupportDesk Quick Start Guide
Richmond Systems SupportDesk Quick Start Guide Table of Contents SupportDesk Quick Start Guide...1 Introduction...1 Pre-requisites...2 Installation at a Glance...2 Installation...3 Setup Console...13
More informationIntroduction 1-1 Installing FAS 500 Asset Accounting the First Time 2-1 Installing FAS 500 Asset Accounting: Upgrading from a Prior Version 3-1
Contents 1. Introduction 1-1 Supported Operating Environments................ 1-1 System Requirements............................. 1-2 Security Requirements........................ 1-3 Installing Server
More informationUser s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
More informationTable of Contents. 2 Getting Started Guide
Table of Contents Welcome... 3 Training & Support... 3 Accessing the online support center... 4 1. System Requirements... 5 2. Installing the Free Evaluation Version... 7 3. Software Download Instructions...
More informationElo 1725L 17 Touch Screen Monitor Installation Guide. Product Name: Elo 1725L 17- inch Monitor
Elo 1725L 17 Touch Screen Monitor Installation Guide Product Name: Elo 1725L 17- inch Monitor 0621407 Copyright 2007 McKesson Corporation. All rights reserved. This documentation is an unpublished work
More informationQuick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
More informationUSB DRIVER INSTALLATION GUIDE
USB DRIVER INSTALLATION GUIDE Use these instructions to install the USB and Microsoft ActiveSync synchronization software for your Monarch Pathfinder Ultra Platinum 6039 printer and computer to communicate.
More informationKCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7
KCU-02 Monitor Software Installation User Manual For Windows XP and Windows 7 Headquarters : No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775
More informationSTATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS
STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS Notes 1. The installation of STATISTICA Enterprise Small Business entails two parts: a) a server installation, and b)
More information1 Minimum system requirements
Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Installation MagIC Net 2.x 1 Minimum system requirements Operating system RAM Memory
More informationBatch Eligibility Long Term Care claims
Hewlett Packard Enterprise Provider Electronic Solutions software lets Connecticut Medical Assistance Program providers verify patient s eligibility and submit and correct claims for services all electronically.
More informationThuraya XT-DUAL. Software Upgrade Manual
Thuraya XT-DUAL Software Upgrade Manual Version 1 / February 2012 1. INTRODUCTION... 3 2. SOFTWARE UPGRADE WITH WINDOWS 7... 4 2.1 Installation of the Upgrader Package... 4 2.2 Manual detection (optional
More informationSA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
More informationDriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186
DriveRight Fleet Management Software Getting Started Guide CarChip DriveRight Drivers Vehicles Product #8186 DriveRight Fleet Management Software Getting Started Guide; P/N 8186 Davis Instruments Part
More informationRSLogix Guard PLUS! Programming Software
Installation Instructions RSLogix Guard PLUS! Programming Software Catalog Numbers 1753-PCS-PAR and 1753-PCS-USB Before You Begin 1. Make sure your personal computer meets the system requirements below.
More informationInstallation Instruction STATISTICA. Concurrent Network License with Borrowing Domain Based Registration
Installation Instruction STATISTICA Concurrent Network License with Borrowing Domain Based Registration Notes: ❶ The installation of the Concurrent network version entails two parts: a) a server installation,
More informationClient Program Installation Guide
Siku Quanshu (Wenyuange Edition) Online Subscription Services Client Program Installation Guide 1. System Requirements The minimum requirements of the Siku Quanshu (Wenyuange Edition) Online Subscription
More informationSECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions
TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote
More informationVicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
More informationDiamond II v2.3 Service Pack 4 Installation Manual
Diamond II v2.3 Service Pack 4 Installation Manual P/N 460987001B ISS 26APR11 Copyright Disclaimer Trademarks and patents Intended use Software license agreement FCC compliance Certification and compliance
More informationTopaz Installation Sheet
Topaz Installation Sheet P/N 460924001E ISS 08FEB12 Content Introduction... 3 Recommended minimum requirements... 3 Setup for Internet Explorer:... 4 Topaz installation... 10 Technical support... 14 Copyright
More informationUpdated: May 2008. Copyright 2005-2008 DBA Software Inc. All rights reserved. 2 Getting Started Guide
Updated: May 2008 Copyright 2005-2008 DBA Software Inc. All rights reserved. 2 Getting Started Guide Table of Contents Welcome 4 Support Center Subscription 5 1. System Requirements 7 2. Installing the
More informationIXP120 Alarm Monitor Utility
IXP120 Alarm Monitor Utility SOFTWARE MANUAL Scope of Document This document provides a brief overview of the Alarm Monitor Utility and its interaction with the IXP120 Software. Document Conventions We
More informationKI6501 Data Manager. Software User Manual
KI6501 Data Manager Software User Manual CONTENTS 1. Installation of USB Virtual COM Port driver software... 2 2. Installation of KI6501 Manager Software... 2 3. Connecting KI6501 to PC (Personal Computer)
More informationUser Guide Win7Zilla
User Guide Win7Zilla Table of contents Section 1: Installation... 3 1.1 System Requirements... 3 1.2 Software Installation... 3 1.3 Uninstalling Win7Zilla software... 3 Section 2: Navigation... 4 2.1 Main
More informationTufts VPN Client User Guide for Windows
Tufts VPN Client User Guide for Windows Introduction The Tufts Virtual Private Network (VPN) implementation is a service that is provided to the faculty and staff of Tufts University to enable secure access
More informationNOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.
INLINE 5 Software INSTALL BULLETIN Page 2: Installing INLINE 5 Page 6: Removing INLINE 5 NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT. IMPROPER INSTALLATION OR USE CAN
More informationGX-2009 Data Logger Management Program Operator s Manual
GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: C Released: 3/19/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by
More informationDUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
More informationPrinter Support Guide. FedEx Ship Manager Software
Printer Support Guide FedEx Ship Manager Software Printer FAQs Installing Printer Drivers How do I download and install the Zebra printer drivers? To download and install the current Zebra printer drivers
More informationRemote Management System
RMS Copyright and Distribution Notice November 2009 Copyright 2009 ARTROMICK International, Inc. ALL RIGHTS RESERVED. Published 2009. Printed in the United States of America WARNING: ANY UNAUTHORIZED
More informationNetwork DK2 DESkey Installation Guide
VenturiOne Getting Started Network DK2 DESkey Installation Guide PD-056-306 DESkey Network Server Manual Applied Cytometry CONTENTS 1 DK2 Network Server Overview... 2 2 DK2 Network Server Installation...
More informationLotus Notes 6.x Client Installation Guide for Windows. Information Technology Services. CSULB
The goal of this document This document was created by the Information Technology Services department to assist the Lotus Notes Coordinators in the successful installation of Lotus Notes release 6 (R6)
More informationInstalling a fresh version of Windows 95b
What you will need Page 2 Summary of what will be involved Page 3 Configuring the BIOS to boot from A: Page 4 Partitioning and formatting the hard disk Partitioning the hard disk (FDISK) Page 5 Formatting
More informationNetwork Scanner Tool R3.1. User s Guide Version 3.0.04
Network Scanner Tool R3.1 User s Guide Version 3.0.04 Copyright 2000-2004 by Sharp Corporation. All rights reserved. Reproduction, adaptation or translation without prior written permission is prohibited,
More informationHistory of Revisions. Ordering Information
No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is
More informationWelch Allyn Vital Signs Monitor 300 Series
Welch Allyn Vital Signs Monitor 300 Series Upgrade Installation Guide Vital Signs Monitor 300 Series Service Utility Tool Version 2.0.0 ii Welch Allyn Vital Signs Monitor 300 Series Copyright 2007, Welch
More informatione-dpp 4.0.2 May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database
e-dpp 4.0.2 May 2013 Microsoft Windows 2003 Server, XP, Vista, 7 Access Database ELTECHS Engineering and Consulting Co., Ltd., Japan www.eltechs.co.jp Tel No. +81 (47) 490-1010 Fax No. +81 (47) 490-1011
More informationAXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
More informationPP8X Printer Driver Installation Instruction
PP8X Printer Driver Installation Instruction Pinnacle Technology Corp. CONTENTS 1 BT Device Installation... 1 2 Printer Driver Installation... 6 3 How to Know the Connecting Port... 10 4 How to Configure
More informationChapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
More informationInstalling a printer in Windows 95.
Installing a printer in Windows 95. Click on Start - Settings - Printers In the Printers Folder double click on the Add Printer Icon Click on the Next Button to start the installation process of your printer
More informationKeystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS
The following instructions are required for installation of Best Access System s Keystone 600N5 (KS600N) network key control software for the server side. Please see the system requirements on the Keystone
More informationGuest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.
Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual
More informationInstallation Instruction STATISTICA Enterprise Server
Installation Instruction STATISTICA Enterprise Server Notes: ❶ The installation of STATISTICA Enterprise Server entails two parts: a) a server installation, and b) workstation installations on each of
More informationFAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1 2011 Sage Software, Inc. All rights reserved. Published by Sage 2325 Dulles Corner
More informationVolume AIG. AGKSOFT ActiveSync Inventory Guide. ActiveSync Inventory Guide
Volume AIG AGKSOFT ActiveSync Inventory Guide ActiveSync Inventory Guide Introduction T he Microsoft ActiveSync or Windows Mobile Device Center can be used to synchronize your Windows PC with your Portable
More informationHost Connectivity Kit PVCAM for PI Cameras Installation
4411-0074 v1b Host Connectivity Kit PVCAM for PI Cameras Installation Introduction After confirming that your computer meets all hardware and software requirements, install the Host Connectivity Kit (HCK)
More informationUser s Manual For Installation of Imposa Software. Version: V1.0
User s Manual For Installation of Imposa Software Version: V1.0 Special Notes All rights reserved. Any part of this manual is not allowed to be reproduced or transmitted in any form or by any means, electronic
More informationFrontDesk Installation And Configuration
Chapter 2 FrontDesk Installation And Configuration FrontDesk v4.1.25 FrontDesk Software Install Online Software Activation Installing State Related Databases Setting up a Workstation Internet Transfer
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationCM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1
CM HOST CM CardTransporter Fuel Communication and Management Software 10.10.06 Software version up to 3.1 CM Host Manual For CardMaster Fuel Control www.cardlockvending.com customers call 888-487-5040
More informationInstallation Instructions for 9555 USB Driver
Prior to using the data modem features of your 9555 handset; you must first install the VCOMPORT 9555 USB Driver. This driver is compatible with: Windows XP Service Pack 2, Windows 2000 Service Pack 4,
More informationTR-3 Channel Editor. Software Manual
TR-3 Channel Editor Software Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed
More informationDSG SoftPhone & USB Phone Series User Guide
DSG SoftPhone & USB Phone Series User Guide Table of Contents Overview Before You Start Installation Step 1. Installing DSG SoftPhone Step 2. Installing USB Phone Step 3. System Check First Time Use Step
More informationAdditional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
More informationAcer LCD Monitor Driver Installation Guide
1 Contents 1 Contents... 1 2 Introduction... 2 3 Installation Guide... 2 3.1 PC requirements... 2 3.2 Installing the Acer LCD Monitor Driver on Windows Vista... 3 3.2.1 Hardware first install... 3 3.2.2
More informationNetwork Server for Windows. Overview of the Sequencher Network Page 2. Installing Sequencher Server for the First Time Page 3
Network Server for Windows Installation Instructions Overview of the Sequencher Network Page 2 Installing Sequencher Server for the First Time Page 3 Adding Sequencher licenses to KeyServer Page 4 Updating
More informationAIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE
AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE CONTENTS AIM software and USB Driver installation Chapter 1 Installing AIM software and AIM USB driver... 2 Chapter 2 Installation under Microsoft Windows
More informationSystem Manager Software Installation Notes
System Manager Software Installation Notes Version 4.0 Service Update 2 63220-060-241B1 Retain for future use. Use this instruction sheet when you install the System Manager Software version 4.0, Service
More informationConfig software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
More informationInstalling ABACUS ELECTRICS USB Optical Probes under Windows 7
Installing ABACUS ELECTRICS USB Optical Probes under Windows 7 AN17a This note assumes that you are installing the drivers on to a clean system, i.e. one on which ABACUS ELECTRICS Optical Probe drivers
More informationOWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
More informationModel 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
More informationSoftware Installation Procedure (MS Windows)
Software Installation Procedure (MS Windows) E9970-96005 Rev. A 02/2004 (3070 05.30p 0603 WN) In this guide... Introduction, 1 Agilent 3070 Tech Support Web Site, 2 Time for Installation, 2 PC Specifications
More informationMicrosoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers
Integration Note October 2000 Prepared by OS Integration Engineering Compaq Computer Corporation Contents Introduction...3 Requirements...3 Minimum Requirements...4 Required Information...5 Additional
More informationInstruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
More informationSMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
More informationFedEx Ship Manager TM
FedEx Ship Manager TM Quick Reference Guide Your Meter Number: Technical Support: 1.877.339.2774 FedEx Ship Manager Installation Instructions FedEx Ship Manager is a desktop shipping solution that automates
More informationPoint of Sale 2015 Enterprise. Installation Guide
Point of Sale 2015 Enterprise Installation Guide Contents About this guide 3 System Requirements - Microsoft SQL Server 2008 R2 Express 3 System Requirements - POS Enterprise 2015 (Administrator) 3 System
More informationMGC WebCommander Web Server Manager
MGC WebCommander Web Server Manager Installation and Configuration Guide Version 8.0 Copyright 2006 Polycom, Inc. All Rights Reserved Catalog No. DOC2138B Version 8.0 Proprietary and Confidential The information
More informationVERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes
More informationVicon Flash Upgrade Software
NOTES NO. REV. SEC. INSTRUCTION MANUAL Refer to XX134-11-00 1108 3 XX134 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT through a PC using the Flash Upgrade software.
More informationLOREX CLIENT Remote Software 4.0
LOREX CLIENT Remote Software 4.0 Instruction Manual English Version 2.0 MODEL: L20WD800 Series www.lorexcctv.com Copyright 2008 LOREX Technology Inc. Table of Contents Table of Contents Software Installation...
More informationQIAsymphony Management Console User Manual
April 2012 QIAsymphony Management Console User Manual For use with software version 4.0 Sample & Assay Technologies Trademarks QIAGEN, QIAsymphony, Rotor-Gene (QIAGEN Group). InstallShield (Informer Technologies,
More informationFedEx Ship Manager Software. Installation Guide
FedEx Ship Manager Software Installation Guide Before you start Check here to see that your PC has what it needs to run FedEx Ship Manager Software: Minimum System and Hardware Requirements Intel Pentium
More informationUpdated: April 2010. Copyright 2005-2010 DBA Software Inc. All rights reserved. 2 Getting Started Guide
Updated: April 2010 Copyright 2005-2010 DBA Software Inc. All rights reserved. 2 Getting Started Guide Table of Contents Welcome 4 Support Center Subscription 5 1. System Requirements 8 2. Installing the
More informationJuniper NetScreen IPSec Dial Client. Installation Guide for Windows 2000 Windows XP Windows Vista
Juniper NetScreen IPSec Dial Client Installation Guide for Windows 2000 Windows XP Windows Vista Revision 2.0 NetScreen is a registered trademark of Juniper, Inc. Windows is a registered trademark of Microsoft
More informationJVC Monitor Calibration 2 User's Guide
JVC Monitor Calibration 2 User's Guide Table of Contents 1. What is JVC Monitor Calibration 2? 2. System Requirement 3. Installation (JVC Monitor Calibration 2) 4. Uninstall 5. Installation (EyeOne Display
More information