De Jaeger, Emmanuel ; Du Bois, Arnaud ; Martin, Benoît. Document type : Communication à un colloque (Conference Paper)

Similar documents
VOLTAGE CONTROL IN DISTRIBUTION SYSTEMS AS A LIMITATION OF THE HOSTING CAPACITY FOR DISTRIBUTED ENERGY RESOURCES

Modeling of PV Based Distributed Generator Systems with Diverse Load Patterns

Three phase circuits

7. Reactive energy compensation

APPLICATION NOTE. Increasing PV Hosting Capacity on LV Secondary Circuits with the Gridco System empower TM Solution

Voltage regulation in distribution systems - Tap changer and Wind Power

Network Hosting Capacity and Distributed Generation

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS

Chapter 24. Three-Phase Voltage Generation

VOLATILITY AND DEVIATION OF DISTRIBUTED SOLAR

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

LOW-COST ACTIVE SHIELD FOR MV/LV SUBSTATIONS

Experimental Verification of Advanced Voltage Control for Penetration of PV in Distribution System with IT Sectionalizing Switches

Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture phase System 4

Three-phase analysis of unbalanced systems

SIMULATING HYBRID ENERGY GRIDS IN SMART CITIES FOCUS ON ELECTRIC ENERGY SYSTEMS

Neutral to Earth Voltage Reduction Methods in Three-Phase Four Wire Distribution Systems

Phase Balancing of Distribution Systems Using a Heuristic Search Approach

Measuring leakage currents in electromedical devices in accordance with IEC EN 62353

Size template. Grid Connection Masterclass Energex John Lansley Senior Network Solutions Engineer

Chapter 12 Three-Phase Circuit

Tutorial One: Calculation of leakage inductance of transformer using FEM MVA, 132 kv/33kv, Y/, Ampere-turns: , No.

LV4MV: A CONCEPT FOR OPTIMAL POWER FLOW MANAGEMENT IN DISTRIBUTION GRIDS, USING DER FLEXIBILITY

Three-Phase Electric Power Distribution for Computer Data Centers

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

Medium-voltage Transformers

Radial Distribution Test Feeders

Open Phase Conditions in Transformers Analysis and Protection Algorithm

Distributed Generation and Power Quality Case Study

How To Improve Power Quality

Electricity Meter in the age of Photovoltaic

THREE-PHASE POWER SYSTEMS ECE 454/554: Power Systems Laboratory

MANAGEMENT OF ELECTRIC VEHICLES CHARGING PROCESSES IN A DSO CONTROL CENTER

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

DG Modeling Challenges & Results. Jens Schoene

BALANCED THREE-PHASE CIRCUITS

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

415V DISTRIBUTION FOR GREEN DATA CENTERS

8 Speed control of Induction Machines

Kinetic energy recovery on railway systems with feedback to the grid

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Solar Power Plant Design and Interconnection

Modeling of Transmission Lines

Introduction to Paralleling of LTC Transformers by the Circulating Current Method

Integration of Distributed Generation in the Power System. IEEE Press Series on Power Engineering

Modeling and Testing of Unbalanced Loading and Voltage Regulation

RENEWABLE ENERGY INFEED R Herman, M Malengret and CT Gaunt University of Cape Town, South Africa

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

SHORT CIRCUIT CURRENT CALCULATION AND PREVENTION IN HIGH VOLTAGE POWER NETS

Measurement of Power in single and 3-Phase Circuits. by : N.K.Bhati

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Scholars Research Library

Structural Axial, Shear and Bending Moments

The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM

EVALUATION OF CURRENTS AND CHARGE IN SURGE PROTECTIVE DEVICES IN LOW-VOLTAGE DISTRIBUTION NETWORKS DUE TO DIRECT LIGHTNING STRIKES

AP1 Electricity. 1. A student wearing shoes stands on a tile floor. The students shoes do not fall into the tile floor due to

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current

Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process

3.0 Results and Discussions

Physical Address: City: State: Zip Code:

Lecture Notes ELE A6

INTERFACES FOR RENEWABLE ENERGY SOURCES WITH ELECTRIC POWER SYSTEMS

Introduction to Engineering System Dynamics

CURRENT TRANSFORMERS INSTALLATION GUIDE

Impact of electric vehicles on the IEEE 34 node distribution infrastructure

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

Understanding Delta Conversion Online "Power Regulation" - Part 2

415V DISTRIBUTION FOR GREEN DATA CENTERS

MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS

Data center power dynamics within the settings of regional power grid

Genetic Algorithm approach to find excitation capacitances for 3- phase smseig operating single phase loads

Power Quality Centre VOLTAGE FLUCTUATIONS IN THE ELECTRIC SUPPLY SYSTEM. Technical Note No. 7 August 2003

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS

Introduction to PowerWorld Simulator: Interface and Common Tools

Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid

Chapter 12: Three Phase Circuits

FUNCTIONS AND CAPABILITIES OF PV INVERTERS TO BE PART OF A SMART GRID

Chapter 9 Balanced Faults

The following table shows approximate percentage wise the

Executive summary. by Michel Clemence, Renzo Coccioni, and Alain Glatigny

WHITEPAPER CABLE CONDUCTOR SIZING

Modeling Simulation Technology Research for Distribution Network Planning *

CARBON ASSESSMENT TICKETING DELIVERY SYSTEMS

K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

6 Scalar, Stochastic, Discrete Dynamic Systems

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

Educational solutions. MV/LV power grid design and operation laboratory

CHAPTER 28 ELECTRIC CIRCUITS

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

GPS Interfacing of Banediya Feeder (M.P) Using MI Power Software

A progressive method to solve large-scale AC Optimal Power Flow with discrete variables and control of the feasibility

TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION. Micro Generation & Small Generation, 3-phase, less than 30 kw

Chapter 14: Inductor design

Modelling framework for power systems. Juha Kiviluoma Erkka Rinne Niina Helistö Miguel Azevedo

Transcription:

"Hosting capacity of LV distribution grids for small distributed generation units, referring to voltage level and unbalance" De Jaeger, Emmanuel ; Du Bois, Arnaud ; Martin, Benoît Abstract This paper revisits the mechanism of overvoltage and voltage unbalance production in the context of the connection of small single-phase DG units to LV distribution grids. Based on quite simplified models of typical LV distribution feeders, the phenomenon is illustrated and quantified, through the introduction of a new index (distribution factor). Finally, some mitigation solutions are investigated. Document type : Communication à un colloque (Conference Paper) Référence bibliographique De Jaeger, Emmanuel ; Du Bois, Arnaud ; Martin, Benoît. Hosting capacity of LV distribution grids for small distributed generation units, referring to voltage level and unbalance.22nd International Conference on Electricity Distribution (CIRED 2013) (Stockholm). Available at: http://hdl.handle.net/2078.1/165491 [Downloaded 2016/06/25 at 01:48:07 ]

HOSTING CAPACITY OF LV DISTRIBUTION GRIDS FOR SMALL DISTRIBUTED GENERATION UNITS, REFERRING TO VOLTAGE LEVEL AND UNBALANCE Emmanuel DE JAEGER Arnaud DU BOIS Benoît MARTIN UCL (University of Louvain) - Belgium UCL - Belgium UCL - Belgium emmanuel.dejaeger@uclouvain.be ABSTRACT This paper revisits the mechanism of overvoltage and voltage unbalance production in the context of the connection of small single-phase DG units to LV distribution grids. Based on quite simplified models of typical LV distribution feeders, the phenomenon is illustrated and quantified, through the introduction of a new index (distribution factor). Finally, some mitigation solutions are investigated. INTRODUCTION Distributed generation (DG) units, especially photovoltaic generators (PV), are nowadays commonly and even more and more present in the low-voltage (LV) distribution grids of many countries. In this context, small size units (i.e. a few kw peak) are usually singlephase connected. The connection of these generators to the public distribution grids is generally not submitted to profound preliminary technical investigations. However, their influence on the system may become non negligible, particularly when the number of such connected devices becomes important. For instance, it appears that some problems regularly occur at the post-connection stage. These problems are especially related to the voltage level on some phases (overvoltage) and voltage unbalance [1]. This paper will first revisit the mechanism of overvoltage and voltage unbalance production in the context of the connection of small single-phase DG units to LV distribution grids. Based on quite simplified models of typical LV distribution feeders, the phenomenon will be illustrated and quantified. Some mitigation solutions will also be investigated. almost the same for all the units, while the local consumption (or load) is rather low (e.g. typically when the sun is shining in a deep blue sky, at noon on a regular week day, in a residential area with many PV installations, most of the inhabitants being at work). Let s first consider the very simple case of the feeder with only one 5 kw PV installation connected at its end. Such a small power unit is generally single-phase (connected between one phase and the neutral conductor). The distribution feeder can be modelled by its series resistance and reactance while the PV unit is modelled by a current source, as illustrated in Figure 1. Figure 1 Simplified case of a feeder with a single-phase PV installation connected at the end The current injected in the grid by the PV installation flows in the phase (i.e. phase b, in this particular case) and neutral conductors, causing voltage variations which are actually observed on all the three phases, according to the phasor diagram shown in Figure 2. INFLUENCE OF DG ON THE VOLTAGE PROFILE OF LV DISTRIBUTION GRIDS Basics In this paper, we deal with voluntarily simplified cases highlighting the worst situations from the overvoltage and voltage unbalance perspective. We typically consider a 1km long overhead LV distribution feeder made of 95mm copper conductors. It is further assumed that the nodes where energy consumers/producers are connected are equidistant along the feeder. 5 kw single-phase DG units are injecting their power in this feeder and the other loads (power consumption) are neglected. This situation is mainly reached when the generation level is high and Figure 2 Phasor diagram of the three-phase voltage at the end of the feeder In this simple illustrative case, it can easily be seen that the phase-to-neutral voltage level is increased for two of the phases (especially the one on which the PV installation is connected), while decreased for the third one, due to the phasor voltage drop on the neutral conductor.

Voltage unbalance : influence of the distribution The distribution of the various PV installations among the three phases is of course the primary influencing element regarding voltage unbalance. When more than one PV installation has to be connected to the system, the situation will indeed be improved if the installations are connected in a balanced way on the different phases. This is illustrated in Figure 3 and in Figure 4, in the particular cases of a 10 nodes radial feeder hosting respectively 4 and 10 PV installations. In the first situation (Figure 3), the installations are all connected to the same phase (phase a), at nodes n 1, 4, 7 and 10 (the nodes being increasingly numbered from 1 to 10, towards the end of the feeder). In the second situation (Figure 4), one installation is connected at each node with a cyclic distribution among the three phases. It is the magnitude of the sum of three vectors having sizes corresponding to the relative proportion of DG units connected to each phase. The relative phase shift of these vectors with each other is 120. This factor is obviously equal to zero if the same amount of DG units is connected to each phase. It is equal to 0.5 when two phases host the same amount of DG units while there is nothing connected to the third one. Finally, it is equal to unity in the case of one phase hosting all the DG units. It is worth noting that this definition is formally similar to the one of the zero-sequence component, in the frame of the Fortescue transformation for three-phase systems. For a given N nodes three-phase feeder hosting n tot single-phase DG installations, there is a discrete relationship between the number of DG (n tot ) and the distribution factor (f D ). There are only a finite number of possible DG combinations on the different phases. Moreover, different (n a, n b, n c ) combinations can lead to the same distribution factor. For instance, the combination (n a, n b, n c ) = (4, 2, 1) leads to the same distribution factor as (2, 4, 1) or (2, 1, 4). As an example, all the possible (n tot, f D ) pairs are plotted in the Figure 5, in the particular case of a 30 nodes radial feeder. Figure 3 Voltage profile along a 10 nodes radial feeder (1km long) with 4 PV installations connected to the same phase (phase a) at nodes 1, 4, 7 and 10 Figure 5 Possible (n tot, f D ) pairs for a 30 nodes radial feeder Figure 4 Voltage profile along a 10 nodes radial feeder (1 km long) with PV installations connected at each node. PV installations are connected to phase a at nodes n 1, 4, 7 and 10; to phase b at nodes n 2, 5 and 8; to phase c at nodes n 3, 6 and 9 Distribution factor In order to take into account the distribution of the connected DG among the three phases, the distribution factor f D is introduced [2]. This factor is defined as: where n a, n b and n c are the number of DG units connected respectively to phase a, b and c, n tot being their sum. GRID HOSTING CAPACITY The 1km radial three-phase feeder has been investigated as a typical case (e.g. rural LV distribution feeder). Multiple simulations have been performed about this feeder assuming 5, 10 or 30 equidistant nodes. Again the further assumption was made that the single-phase grid users are cyclically connected along the feeder. The simulations were made by using a dedicated MATLAB Simulink model [2]. As there are obviously various possibilities of practically realizing a given (n tot, f D ) pair, by positioning the DG installations at different nodes along the feeder, this study was intentionally limited to the worst cases (i.e. the ones leading to the highest overvoltage). Therefore, for the performed simulations, DG installations were systematically placed by starting, for each phase, from the end of the feeder. For example, in the particular case of a 10 nodes feeder, the pair (n tot, f D ) = (3, 1) (corresponding to 3 units all connected to the same phase) was obtained with DG units positioned at nodes 4,

7 and 10. The main observed simulation results were the voltage level and unbalance at the last node (i.e. the end) of the feeder. Figure 6 summarises the results obtained for a 10 nodes feeder. of connected DG units Similar trends are confirmed in the case of the 30 nodes feeder, as shown in Figure 8. Figure 6 Overvoltage at the end (last node) of a 10 nodes feeder, in function of the number of connected DG installations, for various distribution factors For a specified amount of DG units, the overvoltage increases with the distribution factor. For instance, with 6 DG units, it is seen from Figure 6 that the overvoltage is almost doubled when f D goes from 0 (i.e., in this case, 2 units on each phase) to 0.5 (i.e. 3 units on two phases and nothing on the third one). For a given distribution factor, the overvoltage increases with the amount of connected DG units which is intuitively quite understandable. However, there is clearly a limitation to this reasoning. The overvoltage corresponding to (n tot, f D ) = (9, 0) is even lightly smaller than for (n tot, f D ) = (6, 0). As mentioned above, f D is a global (i.e. macroscopic) quantity which does not take into account the physical location of the generation units along the feeder. In this particular case of f D = 0, the compensation of currents in the neutral conductor is better in the configuration n tot = 9 compared with the configuration n tot = 6, leading to a reduced voltage drop and hence a reduced overvoltage (although the worst case was considered in both configurations). The evolution of the negative sequence voltage at the end of the feeder, in function of the amount of DG units and for various values of f D, is given in Figure 7. It qualitatively illustrates the good correlation observed between the overvoltage and the unbalance at the same location. Figure 7 - Negative sequence voltage unbalance factor at the last node of the radial10 nodes feeder, in function of the amount Figure 8 - Overvoltage at the end (last node) of a 30 nodes feeder, in function of the number of connected DG installations, for various distribution factors Note that due to the already mentioned discrete nature of f D in function of n tot (Figure 5), we can only have up to 10 connected DG units for f D = 1 and 20 units for f D = 0.5. Some configurations for which f D = 0.5 appear to be significantly more severe than those corresponding to f D = 1 (which was not observed in the 10 nodes feeder). The evolution of the maximum overvoltage in function of the distribution factor is given in Figure 9. Figure 9 - Maximum overvoltage in function of the distribution factor (30 nodes feeder) VOLTAGE QUALITY ENHANCEMENT Reactive power consumption The inverters connecting PV installations to the grid could be operated in such a way that they inject or consume reactive power, instead of working with a unity power factor, as it is the usual practice. Consuming reactive power will positively impact the overvoltage (Figure 10) but, on the other hand, negatively influence voltage unbalance (Figure 11). The points in these figures represent simulation results obtained for various (n tot, f D ) configurations. They are simply ranked in such a way that the overvoltage (resp. unbalance) curve is monotonically increasing with the configuration No., when cos = 1 (blue curve). The corresponding configurations in the case cos < 1 are then superimposed (red curve).

Figure 10 Positive impact of reactive power consumption on the maximum overvoltage observed for various configurations Figure 11 Increase of the voltage unbalance due to reactive power consumption for various configurations Feeder loop configuration Transforming the radial structure of a feeder into a loop could be beneficial as well. Two possible configurations, depicted in Figure 12, have been investigated. Figure 12 Looping a radial feeder: two possible topological configurations In the left-hand case of Figure 12, L loop, the length of the loop connection line (i.e. the piece of line added in order to loop the feeder) is equal to the distance between two (supposed equidistant) nodes along the feeder while in the right-hand situation, it has the same length as the whole feeder itself. The benefit of looping the feeder is illustrated in Figure 13. The points corresponding to different (n tot, f D ) configurations are again ranked in order to get a monotonically increasing curve, for the case of the initial radial feeder (without loop). Figure 13 Overvoltage reduction by looping the feeder Similar results are obtained for the voltage unbalance, with a reduction factor up to 5. CONCLUSIONS AND PERSPECTIVES The influence of single-phase DG units in LV distribution feeders has been highlighted by thorough simulations. Relying on the fact that voltage level and unbalance problems are not only arising due to the number of connected DG units, but also due to their distribution among the three phases, a new index was introduced in order to quantify this distribution effect (the so-called distribution factor ). This index is well suitable for the description of overvoltage and voltage unbalance in radial LV distribution feeders. It can be used for the investigation and further quantification of the hosting capacity of a given grid. From a very practical point of view, the connection of new single phase units could be assessed in order to minimize this index, knowing the actual distribution of already connected ones. It could be considered in the frame of future standardization works. Finally, some possible mitigation solutions were investigated (other than balancing the DG units over the phases), either in the topology and operation mode of the grid or at the DG side. Controlling the DG units in order to consume reactive power can appear to be a solution to reduce the maximum overvoltage but it has a negative impact on the voltage unbalance. Looping radial feeders can also be a valuable option. The proposed approach and obtained results, corresponding to simple worst cases, should be extended and further refined, by considering more realistic feeder topologies and taking the actual load into account. REFERENCES [1] C. Reese, L. Hofmann, Analysis and reduction of effects of single-phase loads and generators on low voltage distribution grids, 21st International Conference on Electricity Distribution (CIRED 2011), Paper 1226 [2] A. Du Bois, B. Martin, Capacité d hébergement des réseaux publics de distribution basse tension pour des petites installations photovoltaïques, MSc thesis (in French), Université catholique de Louvain, 2012.