Application Guide Selection of Type Enclosures



Similar documents
NEMA Enclosure Types

JIC CONTINUOUS HINGE BOXES

PAINT BOOTH LIGHTING

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

T R A N S F E R A B L E F U L LY

Low Voltage Transformers Sealed, General Purpose, Dry Type

Basics of Explosion Protection

HAZARDOUS AREA TECHNICAL GUIDE

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Good Housekeeping BMP

IP Rating Chart. 910 East Orangefair Lane Anaheim, CA USA , Fax

A. Work on this project shall consist of, but is not limited to, the following:

Scepter PVC Molded Junction Boxes

ENVIRONMENTAL EFFECTS ON COATINGS

BLACK JACK ALL WEATHER ROOF COATING

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

Metal Rescue Rust Remover Technical Data

CONTENTS. 1 cooling technology white paper

Type 1, 3, & 3R Enclosures

Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 770 alone) 5 minutes 30 sec. at 220 C (maximum curing conditions)

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Autobody/Collision and Repair Technology/Technician CIP Task Grid

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Solving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators.

Division 9. SignaFlor Pad and Pour Flooring System

Colorado State University. Durrell Center Roof Repair

Identifying Your Hazardous Waste

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Introducing an All New Line of Cleaning Chemicals

FIRETEX FX Range. Intumescent protection for steel framed car parks

White rust on galvanized and galvanized pre-painted steel. Technical Information

Screw Plug Immersion Heaters

RAPTOR TRUCK BED LINER - BLACK

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Houston Plating & Coatings

Winnipeg Fire Department Fire Prevention Branch

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Minor Cracks in Horizontal Surfaces

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Profiles for floors of same height Cerfix Projoint

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SECTION GUARDA SECURITY WINDOW SCREENS

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

Protecting Galvanized Steel Sheet Products from Storage Stain Rev 2.1 Aug-03

ASCO SERIES 185 Power Transfer Switches

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

& CLEANING GUIDE MAINTAIN BEAUTY & PERFORMANCE

SECTION CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS

SECTION POLISHED CONCRETE FINISHING

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Concrete Repair. Applications and Procedures

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Ultrasonic support removal tank

INFRARED RADIANT HEATERS. air heaters

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

Technical Data Sheet February 2014

Good Boards = Results

Newfoundland and Labrador Paint Recycling Program Guidelines

SC2000 CEMENT BONDING PROCEDURES

Summit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Anodizing Reference Guide

GUIDELINES FOR HANDLING FABRICATION INSTALLATION AND CLEANING

Vision Home Inspection

Material Safety Data Sheet Ampicillin, sodium salt MSDS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

55 OUTODOOR TOTEM Floorstanding professional Display Enclosure

the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

Tractor Painting Tips

7. Chemical Waste Disposal Procedures

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Material Safety Data Sheet

Company Profile p.3. Product Coding System p.4. Saturated carboxylated polyesters for TGIC systems

Material Safety Data Sheet

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB

GENERAL MAINTENANCE MANUAL

Dehumidification Frequently Asked Questions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

PRODUCT DATA SHEET DESCRIPTION:

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

RUBBER SLEEVE KNIFE GATE VALVE

Technical application guide IP codes in accordance with IEC 60529

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Chemical Reducing Solution CRS

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

Chapter 2 Basis of design and materials

Transcription:

Application Guide Selection of Type Enclosures. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 1

Mission Statement The purpose of this document is to educate the reader with regard to the definitions, performance, and applicability of various NEMA enclosure types. This will assist the specifier in the selection of the appropriate enclosure for their environment and application. Quick reference tables are included where applicable to consolidate data for straightforward comparisons. The goal is to familiarize users and specifiers with all ASCO enclosure offerings and increase comfort level in making the proper recommendations or purchase decisions. This helps eliminate costly modifications and rework potentially required when an improper enclosure is selected for the intended use of a switch switchgear lineup. It is essential that the reader be aware of the environmental conditions that exist at the site in question, understand the capabilities of each type of enclosure, and available ASCO solutions. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 2

Table of Contents Industry Standards Page 4 5 Glossary of Terms Used In Industry Standard Documents Definitions Page 6-7 Definitions of Environmental Conditions, from Non-hazardous to Severe Typical Enclosure Applications Page 8 Examples of Typical Applications and Use Reference Tables: Indoor & Outdoor Locations Page 9-10 Comparison of Specific Non Hazardous Applications Enclosure Type vs. IP Rating Page 11 Comparison of U.S. Standards to European Materials, Paint, and Finishes Page 12-13 Paint Processes, Chemical Resistance Chart ASCO Enclosure Solutions Page 14-16 Indoor/Outdoor Paint Finish and Steel Gauge Options Performance Matrix Page 17 Price vs. Performance Based On Enclosure Type Enclosure Selection Fast Facts Page 18-20 Examples of Questions and Answers Related to Enclosure Specification ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 3

Industry Standard Terms Corrosion-Resistant Constructed to provide a degree of protection against exposure to corrosive agents such as salt spray. Type 3RX and 4X enclosures meet this requirement. Damp Locations Locations protected from weather and not subject to saturation with water or other liquids but subject to moderate degrees of moisture. Examples of such locations include partially protected locations under canopies, marquees, roofed open porches, and like locations, and interior locations subject to moderate degrees of moisture, such as some basements, some barns, and some cold storage warehouses. Indoor enclosure types with a rating type that fits the specific application are typically acceptable. Dust Tight Constructed to prevent circulating or airborne dust from entering the enclosure under specified test conditions. Type 1A enclosures formerly addressed these conditions, but that classification has become obsolete. Type 12 enclosures are now typically used for this purpose. Type 4 and 4X will also comply, but at a premium cost. Drip Tight Constructed so falling moisture or dirt does not enter the enclosures under specified test conditions. Type 4, 4X, and 12 enclosures meet this requirement. Indoor Not to be exposed to weather. Type 1 and 12 enclosures meet this requirement. Oil Resistant Constructed so that oil will not interfere with successful operation of equipment. Type 12 enclosures meet this requirement ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 4

Outdoor Constructed or protected so that exposure to the weather will not interfere with successful operation of equipment. Type 3R, 3RX, 4, and 4X enclosures meet this requirement. Enclosures with these ratings may also be used indoors if desired. Rainprooof Constructed, protected, or treated to prevent beating rain from interfering with the successful operation of the apparatus, or resulting in wetting of live parts and wiring within the enclosure under specified test conditions. Type 3R and 3RX enclosures meet this requirement. Rain Tight Constructed or protected so beating rain will not result in water entering the enclosure under specified test conditions. Type 4 and 4X enclosures meet this requirement. Water Tight Constructed so moisture will not enter the enclosure when it is subjected to a stream of water under specified test conditions. Type 4 and 4X enclosures meet this requirement. Weatherproof Constructed or protected so exposure to the weather will not interfere with successful operation of the equipment. Rainproof, rain tight, or water tight equipment can fulfill the requirements for weatherproof where varying weather conditions other than wetness, such as snow, ice, dust, or temperature extremes, are not a factor. Wet Locations Installations underground or in concrete slabs or masonry in direct contact with the earth; in locations subject to saturation with water or other liquids, such as vehicle washing areas; and in unprotected locations exposed to weather. Use weatherproof enclosures with a type rating that fits the specific application. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 5

There are other types of enclosures not covered by this glossary of definitions. The focus of this document is on enclosures applicable to equipment of the types supplied by ASCO. Definitions (From UL 50 Twelfth Edition 2007) Enclosure definitions are listed in order of their applicability, from the least hazardous environmental conditions to the most severe: Type 1 Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt. Type 12 Constructed (without knockouts) for indoor use to provide protection against falling dirt; against circulating dust, lint, fibers, and flyings; against dripping and light splashing of non corrosive liquids; and against light splashing and consequent seepage of oil and non corrosive coolants Type 12 enclosures are oil resistant, and constructed so oil will not interfere with successful operation of equipment. They are not oil tight, which means oil could enter a Type 12 enclosure under certain conditions. Type 3R Constructed (with knockouts on the sides and bottom) for either indoor or outdoor use to provide protection against falling dirt, rain, sleet, snow, and windblown dust. Will be undamaged by the external formation of ice on the enclosure. Type 3R enclosures are rainproof which means they are constructed, protected, or treated to prevent beating rain from interfering with the successful operation of the apparatus or result in wetting of live parts and wiring within the enclosure under specified conditions. They are not rain tight, which means exposure to beating rain could result in water entering a Type 3R enclosure under certain conditions; nor are they water tight, which means moisture could enter a Type 3R enclosure when subjected to a stream of water under certain conditions ASCO standard Type 3R enclosures are fabricated from cold rolled steel, a low - carbon, cold finished steel produced by passing bar stock through a set of rollers. Type 3RX Similar to Type 3R, except for additional provisions for a degree of protection against corrosion. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 6

ASCO standard Type 3RX enclosures are fabricated from 304 grade stainless steel for both ATS and SEATS products. 316 grade stainless steel, which offers additional corrosion protection for severe environments, is an option. Type 4 Constructed for either indoor or outdoor use to provide protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose directed water. Will be undamaged by the external formation of ice on the enclosure. Type 4X Same as Type 4 except constructed from corrosion-resistant material. Corrosion-resistant as defined by industry standards is: Constructed to provide a degree of protection against exposure to corrosive agents such as salt spray. Stainless steel is the strongest of the corrosion resistant materials. It exhibits many of the same resistances attributed to fiberglass materials as well as resistance to highly polar solvents such as acetone and MEK. 316 grade stainless steel is an option that provides improved resistance to salt, some acids, and high temperature. 316 grade is a strongly recommended choice for marine environments which are within 5 miles of salt water or otherwise subject to exposure to salt spray. Note that 316 grade resistance to sulfates and chorine is less than that provided by 304 grade.. Fiberglass is also an option that meets Type 4X criteria. Cautionary note: Stainless steel of any type is not stain free, and while it offers a high degree of performance, under certain environmental conditions it remains susceptible to rust deposits on the surface. These deposits are often created by contamination resulting from rain or marine environments. Periodic cleaning of the surfaces of stainless steel enclosures with a neutral solution is recommended to avoid tea staining. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 7

Typical Enclosure Applications Type 1 Climate Controlled Indoor Shelters Indoor Security and Fire Applications Low Contamination Electrical Rooms Office and Indoor Warehouse Environments Type 3R / Type 12 Wireless Telecommunications Security and Fire Applications Utility Applications Type 4 Cement Plants Diaper Manufacturing Outdoor Plants, Buildings in Dry, Desert, Arid Areas Military Bases Rubber Tire Manufacturing and Retreading Industrial Plants Type 4X Marine Duty Applications Waste Water Treatment Facilities Bottling Plants Pulp and Paper Applications Pharmaceuticals, and Clean Room Production Rooms Health and Hospital Cosmetic Compounding and Manufacturing Petroleum and Chemical Processing ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 8

Reference Tables For Indoor And Outdoor Locations Comparison of Specific Non-Hazardous Applications in Indoor Locations Provides a Degree of Protection Against Enclosure Type the Following Environmental Conditions 1 1 4 4X 12 Incidental contact with the enclosed equipment Falling Dirt Falling Liquids and Light Splashing Dust, Lint, Fibers, and Flyings 2 Hose - Down and Splashing Water Oil and Coolant Seepage Oil or Coolant Spraying and Splashing Corrosive Agents Occasional Temporary Submersion 1. These enclosures may be ventilated, however Type 1 may not provide protection against small particles of falling dirt when ventilation is provided in the enclosure top. 2. These fibers and flyings are non - hazardous materials and are not considered Class II type ignitable fibers or combustible flyings. For Class III type ignitable fibers or combustible flyings see the National Eletcrical Code Section 505. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 9

Reference Tables For Indoor And Outdoor Locations Comparison of Specific Non-Hazardous Applications in Outdoor Locations Provides a Degree of Protection Against the Following Environmental Conditions 3R 1 3RX 1 4 4X Incidental contact with the enclosed equipment Rain, Snow, and Sleet 2 Sleet 3 Windblown Dust Hose - Down Corrosive Agents Occasional Temporary Submersion Enclosure Type 1. These enclosures may be ventilated 2. External operating mechanisms are not required to be operated when the enclosure is ice covered 3. External operating mechanisms are operable when the enclosure is ice covered The preceding tables are excerpts from the National Electrical Manufactures Association (NEMA) Standards Publication 250 Enclosures for Electrical Equipment (1000 Volts Maximum), and UL 50 Twelfth Edition Dated September 4, 2007 Enclosures for Electrical Equipment, Non Environmental Considerations. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 10

Enclosure Type vs. IP Rating (U.S, Standard vs. European) Electrical enclosures are rated by type, either (NEMA 250/UL50) and/or IP rated (IEC 60529). Type ratings and IP ratings have only the following in common: 1 A degree of protection for persons from hazardous components inside the enclosure 2 A degree of protection for equipment inside the enclosure from ingress (entrance/access) of solid foreign objects, including dust 3 A degree of protection for equipment inside the enclosure from ingress (entrance/access) of water NEMA 250 and UL 50 type-rating documentation defines additional requirements a type rated enclosure must meet. These include: Mechanical impact on enclosure walls Gasket aging and oil resistance Corrosion resistance Door and cover latching requirements Sheet metal gauge construction requirements (UL 50 only) Electrical enclosures that carry only an IP rating have not been designed to meet additional type rating requirements. Therefore, a type rating cannot be assigned to an enclosure that has only been IP rated. ASCO does not provide enclosures designed only to IP rating requirements. The preceding paragraphs are excerpts from the Industry Standard s section of the Hoffman Enclosure Specifier s Guide, Volume 21. For more detailed information refer to the Hoffman Specifier s Guide Volume 21, available at http://www.hoffmanonline.com/ ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 11

Material and Paint Finishes Powder Paint Process Flow The following describes the powder paint procedure utilized for enclosures fabricated in-house by ASCO and not third party suppliers. Enclosure parts enter a seven stage washing system consisting of three chemical treatments and four rinsing baths. Stages of chemical treatment are: First Stage: Fourth Stage: Seventh Stage: ParcoCleaner ZX4 4% Solution Bonderite NTI 3% Solution Parcolene 7100 Sealer 5% Solution A rinse is performed after each above chemical treatment. Upon completion of the wash/chemical treatment the parts go through a dry off oven, which removes all excess moisture and prepares the parts for the application of powder paint. Paint can either be applied manually or automatically. ASCO standard ANSI 61 gray is applied on an automated line. For other colors, an operator applies the paint to conveyor-fed parts in a manual spray booth, evenly coating all surfaces. Line speed is dependent upon the oven cure temperature, and can be slowed down to allow the operator to ensure the parts are uniformly coated. There is no re-use of excess powder, so paint color can be changed without the risk of contamination of subsequent parts. The majority of powder painted parts are treated in an automated paint booth. As conveyor-fed parts proceed through the booth, electric sensors determine the approximate size and shape of the part and select an appropriate paint gun to spray the part, minimizing excess discharge of paint. Based on a timed sequence, the powder paint guns begin to discharge the paint. Discharge remains continuous until the part has completely passed the last gun, ensuring total and uniform coverage. Parts then enter the curing oven; temperature is set appropriately with the paint manufacturer s specifications. The heat transforms the powder into a semi liquid state which flows to uniformly coat the parts. Parts air cool before being removed from the conveyor, allowing the paint to completely solidify. The following quality tests are performed at specified sampling intervals, to assure process qualification and consistency: Visual Quality Paint Adhesion Paint Thickness Curing Oven Temperature Impact Test (Performed by powder paint supplier or manufacturer) Neutral Salt Spray (Performed by outside source) ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 12

Chemical Resistance Chart Solvents Alkalis Acid Stainless Steel Grade 316 Polyster Polycarbonate Recommended Stainless Steel Grade 304 ABS ABS Aluminum Stainless Steel Grade 316 Stainless Steel Grade 316 Steel Epoxy ed Stainless Steel Grade 304 Stainless Steel Grade 304 Fiberglass Fiberglass Satisfactory Polycarbonate Polycarbonate ABS Steel, Epoxy ed Limited Use Steel, Epoxy ed Aluminum Aluminum The chart above is intended to provide a brief overview of enclosure performance in resisting corrosion from three classes of chemicals, solvents and organics, alkalis, and oxidizers, and acids and neutral salts. Materials are rated on a scale from Recommended to Limited Use. For detailed chemical resistance charts refer to the Hoffman enclosure catalog under Technical Information, pages T1-11 found at www.hoffmanonline.com The preceding chart is excerpted from the Hoffman Enclosure Specifier s Guide, Volume 2 ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 13

ASCO Enclosure Solutions Enclosure Type Product 185 185SE Indoor Outdoor 1 12 3R 4 4X 14 Gauge Steel N/A 12 Gauge N/A N/A Aluminum Alloy for 100 230A Finish: RAL 7035 Light Gray Polyester 14 Gauge Steel Finish: RAL 7035 Light Gray Polyester N/A 0.102 thick for 260 400A. Finish: RAL 7035 Light Gray Polyester 0.10 thick Aluminum Alloy for 200A 0.102 thick for 400A Finish: RAL 7035 Light Gray Polyester N/A N/A 300 12/14 Gauge Steel for 600A 12 Gauge Steel for 800 2000A Steel For Switch Ampere Sizes 30 230, 260 400, 2600 3000A 14 Gauge Steel for 600A 12 Gauge Steel for 800 1600A N/A for 2000 3000A Steel For Switch Ampere Sizes 30 230, 260 400A 14 Gauge Steel for 600A 12 Gauge Steel for 800 2000A N/A for 2600 3000A Steel For Switch Ampere Sizes 30 230, 260 400A 14 Gauge Steel for 600A 12 Gauge Steel for 800 1200A N/A for 2000 3000A Steel For Switch Ampere Sizes 30 230, 260 400, and 1600A 14 Gauge 304 Stainless Steel for 230 400A, 600A 12 Gauge 304 Stainless Steel for 800 1000A. N/A for 1200 3000A 304 Stainless Steel For Switch Ampere Sizes 30 230A Finish: Light Gray (ANSI 61) Finish: Light Gray (ANSI 61) Finish: Light Gray (ANSI 61) Finish: Light Gray (ANSI 61) 316 Grade Stainless Steel optional Finish: Polish ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 14

Enclosure Type Product Steel for 70 3000A Indoor Outdoor 1 12 3R 4 4X N/A Steel for Steel for (Use Type 3R) 70 3000A 70 1000A N/A 1200 3000A 316 1 Stainless Steel for 70 1000A N/A 1200 3000A Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: Polish 300SE 4000/7000 12 Gauge Steel for 1200A Steel for 30 1000 & 1600 4000A Finish: Light Gray (ANSI 61) 14 Gauge Steel for 260 600A 12 Gauge Steel for 800 1000A Steel for 30 230, 1200, & 1600A N/A 2000 4000A Finish: Light Gray (ANSI 61) 14 Gauge Steel for 260 600A 12 Gauge for 800 1000A Steel for 30 230 & 1200 4000A Finish: Light Gray (ANSI 61) 14 Gauge Steel for 260 600A 12 Gauge Steel for 800 1000A Steel for 30 230, 1200, & 1600A N/A 2000 4000A Finish: Light Gray (ANSI 61) 14 Gauge 304 Stainless Steel for 260 600A 12 Gauge 304 Stainless Steel for 800 1000A 304 Stainless for 30 230, 1200, & 1600A N/A 2000 4000A 316 Stainless is Optional Finish: Polish Steel for 70 4000A N/A (Use Type 3R) Steel for 70 4000A Steel for 70 1000A N/A 1200 4000A 316 1 Stainless Steel for 70 1000A N/A 1200 3000A 7000SE Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: ANSI 61 Gray Polyester Semi Gloss Electrostatic Finish: Polish ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 15

Note 1: The ASCO standard Type 4X enclosures are fabricated from 304 stainless steel. This is a Corrosion resistant iron based alloy containing between 18% and 20% chromium. 316 grade stainless steel is the ASCO standard for 4X enclosures for 3AUS and 7AUS Service Entrance switches. 316 grade stainless steel has a higher chemical composition of nickel, chromium, and molybdenum than 304 grade, providing increased corrosion resistance to chlorides and many common industrial chemicals. It is frequently specified by customers, especially for waste water treatment plant requirements. 316 grade stainless steel is ideal for wet locations, and in areas where caustic elements are present, since it is a superior material choice for these types of environments and ideal for marine applications. It is strongly recommended for any outdoor application which is within 5 miles of salt water or otherwise subject to salt spray. 2. The ASCO standard Type 3R enclosures are fabricated from cold rolled steel, a low carbon, cold finished steel produced by passing bar stock through a set of rollers. The ASCO standard Type 3RX enclosures are fabricated from 304 grade steel for both ATS, and SEATS products. 316 grade stainless steel, which offers additional corrosion protection for severe environments, is an option.. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 16

Performance Matrix Price vs. Performance Enclosure Type Matrix Price High Medium Low Enclosure Type Performance High Medium Type 4X Secure Type 4X Non- Secure Type 3R/12/4 Secure Type 4 Non-secure Type 3R/12 Non Secure Low Type 1 ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 17

Enclosure Selection Fast Facts Examples Of Answers To Frequently Asked Specification Questions Example 1 Is the enclosure intended to be mounted in an indoor location? Yes What type of environmental conditions exist? - Incidental contact with the enclosed equipment - Falling dirt Enclosure Recommendation: Specify Type 1 Note: Type 4, 4X, and 12 will also meet these requirements, but are not necessary since they exceed the environmental conditions indicated.. Example 2 Is the enclosure intended to be mounted in an indoor location? Yes What type of environmental conditions exist? - Incidental contact with the enclosed equipment - Falling Dirt - Falling Liquids and Light Splashing - Dust, Lint, Fibers, and Fyings - Hose Down and Splashing Water Enclosure Recommendation: Specify Type 4 Note: Type 4X (Stainless Steel) will also meet the requirements and provide additional protection against Corrosive Agents. Type 12 will also meet the requirements except for the Hose Down and Splashing Water, but will provide added protection against Oil and Coolant Seepage. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 18

Example 3 Is the enclosure intended to be mounted in an indoor location? Yes What type of environmental conditions exist? - Incidental contact with the enclosed equipment - Falling Dirt - Falling Liquids and Light Splashing - Dust, Lint, Fibers, and Fyings - Hose Down and Splashing Water - Corrosive Agents Enclosure Recommendation: Specify Type 4X (304 Grade Stainless Steel) Note: The ASCO standard grade of stainless steel is 304. 316 is optional but not necessarily required for indoor applications, except where exposure to harsh chemical, acid, or alkali conditions may apply. Example 4 Is the enclosure intended to be mounted in an indoor location? Yes What type of environmental conditions exist? - Incidental contact with the enclosed equipment - Falling Dirt - Falling Liquids and Light Splashing - Dust, Lint, Fibers, and Fyings - Oil and Coolant Seepage Enclosure Recommendation: Specify Type 12 Example 5 Is the enclosure intended to be mounted in an outdoor location? Yes What type of environmental conditions exist? ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 19

- Incidental Contact with the Enclosed Equipment - Rain, snow, and sleet Enclosure Recommendation: Specify Type 3R Note: Type 3RX, 4, and 4X will also meet the requirements, but not are necessary since they exceed the environmental conditions indicated. Example 6 Is the enclosure going to be mounted in an outdoor location? Yes What type of environmental conditions exist? - Incidental Contact with the Enclosed Equipment - Rain, snow, and sleet - Windblown Dust - Hose Down Enclosure Recommendation: Specify Type 4 Note: Type 4X (Stainless Steel) will also meet these requirements, and provide additional protection against Corrosive Agents Example 7 Is the enclosure going to be mounted in an outdoor location? Yes What type of environmental conditions exist? - Incidental Contact with the Enclosed Equipment - Rain, snow, and sleet - Windblown Dust - Hose Down - Located 4 Miles From Salt Marsh Shoreline Enclosure Recommendation: Specify Type 4X (316 Grade Stainless Steel) Note: The ASCO standard grade of stainless steel is 304. 316 is optional but highly recommended for outdoor applications where exposure to marine air may be present, to avoid discoloration. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 20