REQUEST FOR QUOTATIONS



Similar documents
Guidelines for Preparing for a Temporary Steam Plant

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

PLP - TERMS AND CONDITIONS

INSTRUCTIONS, REQUIREMENTS

RFQ No. 4856B /MD. REQUEST FOR QUOTATION City of Norfolk. Vendor: Issued: 11/06/2015 Due: 2:00 PM

SIOUX HYBRID WATER HEATER

Solicitation Addendum One (1) RFQ CARPET CLEANING SERVICES

GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Energy Efficient Operations and Maintenance Strategies for Boilers

SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN AGREEMENT. A. Silver Plan

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

610-6-MURPHY PRIORITY SERVICE AGREEMENTS PLUMBING HEATING COOLING DUCT CLEANING BATHS TILE Thank You. Richard G.

How To Buy A Government Contract

IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL

Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.

The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC October 15, 2008 BOILER PLANT OPERATIONS

Boiler and Burner Cleaning and Servicing Specifications

REQUEST FOR QUOTATIONS (THIS IS NOT AN ORDER) 1. REQUEST NO. 2. DATE ISSUED 3. REQUISITION/PURCH. REQUEST NO.

Factory owners must ensure the boiler is:

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

FLASH TANK ECONOMIZER PRODUCT GUIDE

Steam System Efficiency. Bill Lumsden Leidos Engineering

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Form P ITEM DESCRIPTION UNIT ESTIMATED 12 MONTH QUANTITY

HOW TO DO BUSINESS WITH THE STATE OF ALASKA


Washington County School District Request for Proposal School Bus Fleet Tracking System RFP #TD 1011

CITY OF URBANA, ILLINOIS REQUEST FOR QUOTE GENERAL TERMS, CONDITIONS AND SPECIFICATIONS FOR: ONE (1) ELECTRIC PASSENGER VEHICLE RFQ #

Request for Qualifications. For Heating, Ventilating and Air Conditioning Contractor Services

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

REQUEST FOR SEALED, COMPETITIVE QUOTES FOR TEMPORARY PERSONNEL SERVICES COMPOST SITE GATEKEEPERS. January 19, 2016

REQUEST FOR QUOTATIONS (RFQ) Open Market Lowest Price, Technically Acceptable

Richardson Independent School District Purchasing Department 970 Security Row Richardson, Texas 75081

GENERAL TERMS & CONDITIONS OF QUOTE

REQUEST FOR QUOTES (RFQ) FOR HVAC MAINTENANCE AND REPAIR SERVICES. RFQ Release Date: August 3, Quote Due Date: August 21, 2015 at 5:00 p.m.

Provided and Administered by CornerStone United, Inc. Eastway Plaza 1899 Tate Boulevard SE, Suite 2110 Hickory, NC FAX

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

City of Statesboro. Request for Qualifications: Life Insurance Brokerage Services

Action Plan Template HVAC Page 1

ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Quik Lining Systems Heater Owners Guide

THIS ADDENDUM MUST BE ACKNOWLEDGED. THIS ADDENDUM SHALL BECOME A PART OF THIS SOLICITATION. Amend Invitation to Bid 14-MC-2194 as follows:

ELECTRICAL ORDER KAY BAILEY HUTCHISON CONVENTION CENTER DALLAS

VACUUM REFRIGERATION SYSTEMS

REQUEST FOR BIDS HVAC PREVENTATIVE MAINTENANCE AND SERVICE JANUARY 18, Issued by: NH Liquor Commission. PO Box 503, Concord, NH 03302

I. STEAM GENERATION, BOILER TYPES

INSTRUCTIONS TO BIDDERS

CITY OF MARTINSVILLE REQUEST FOR PROPOSALS UTILITY BILL PRINTING & MAILING SERVICES SEPTEMBER 22, 2015

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

COLOCATION SERVICE SCHEDULE

a. Proposals shall be submitted in a sealed envelope and addressed as follows:

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

Sub.: Request for Quotation of

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

BID REQUEST. BID SUBMITTAL DEADLINE: November 21, 2014, AT 2:00 PM Or

Evaluate, Clean, and Tune Guidance

REQUEST FOR PROPOSAL FOR DORCHESTER COUNTY COUNCIL HVAC SERVICES DCG Due Date December 6, 2011

COLOCATION SERVICE SCHEDULE

Saving Boiler Fuel. Figure 1: Boiler System Operation Costs

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION INTERSTATE TRANSPORTATION OF GOODS (FREIGHT) SERVICES PUBLICATION

Tender document Estate Maintenance Department Web : Phone :

Regional Council of Goyder

Utility Department City/ Province. State, ZIP, Country

a. Proposals shall be submitted in a sealed envelope and addressed as follows:

Flood Checklist ACTION TO BE TAKEN BEFORE THE FLOOD SEASON

Solicitation Web Hosting Services for the Disaster Volunteer Network. State of California

Split System Air Conditioning System Replacement at Area 3 Maintenance Facility

REQUEST FOR PROPOSAL: PRT LIVE STREAMING WEBCAMS

Routine and Emergency Boiler Operation

Energy Efficiency in Steam Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ATLANTA PUBLIC SCHOOLS

Recover Heat from Boiler Blowdown Water

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Metropolitan Washington Airports Authority Office of Public Safety Fire & Rescue Department. Fire Code Enforcement Division

Request for Proposals BUILDING DEMOLITION SERVICES

REQUEST FOR PROPOSAL NO. RFP09503 MIDDLE SCHOOL AND HIGH SCHOOL YEARBOOKS. Submittal Deadline: October 29, Time: 10:00 a.m.

How To Bid On A Building Project In San Jose

REQUEST FOR QUOTATIONS (RFQ) Drainage / Cleaning of Septic Well for CCI Kabul office

BOSCH General Delivery Specifications for Machinery and Equipment Apr. 1, 2005

Chapter 10 Receiving, Inspection, Acceptance Testing and Acceptance or Rejection

To qualify for discount rate, request and payment must be received 21 days prior to show/ event opening. Payment in U.S. currency only.

Transcription:

Metropolitan Washington Airports Authority Materials Management, MA-133 Terminal A, Room 278 Washington, DC 20001-4901 REQUEST FOR QUOTATIONS 1. FOR INFORMATION CONTACT NAME: Regina Leigh 2. REQUEST FOR QUOTATIONS NUMBER 3. DATE ISSUED August 15, 2011 4. DESCRIPTION OF GOODS OR SERVICES TELEPHONE NUMBER: (No Collect Calls) 703-417-8108 Page 1 The intent of this Request for Quotation (RFQ) is to obtain competitive quotations to provide all adequate supervision, manpower, expertise, and technical service necessary for the safe operation of a 150 H.P portable rental steam boiler system for a period of seven (7) months mounted and piped in an enclosed trailer for Ronald Reagan Washington National Airport. All questions concerning this solicitation must be submitted by 3:00 PM August 26, 2011 via the Airports Authority's website at: http://www.mwaa.com/4238.htm 5. LOCAL DISADVANTAGED BUSINESS ENTERPRISE PARTICIPATION REQUIREMENT This Request for Quotations has a 0% LDBE participation requirement. 6. DEADLINE FOR QUOTATION SUBMISSION Sealed quotations in original are due at the place specified at the top of this form by 4:00 P.M. local time, September 12, 2011. Sealed envelopes containing quotations shall be marked to show the quoter s name and address, the RFQ number, and the date and time quotations are due. The Authority reserves the right to make an award based on this solicitation. NOTE: Quoters are responsible for verifying number and dates of amendments prior to submitting a quotation. Failure to acknowledge an amendment may result in quotation being determined non-responsive. 7. NAME AND ADDRESS OF QUOTER (Include Zip Code) 9. REMITTANCE ADDRESS (If different than Item 7) 10A. E-MAIL ADDRESS 8A. TELEPHONE NUMBER 8B. FAX NUMBER 10B. COMPANY INTERNET WEBSITE NOTICE: Quotation shall be valid for 60 days 11. ACKNOWLEDGMENT OF AMENDMENTS (This quoter acknowledges receipt of amendments to this Request for Quotations - give number and date of each) 12A. NAME & TITLE OF PERSON AUTHORIZED TO SIGN AMENDMENT NO. 12B. SIGNATURE 12C. DATE DATE (2/2006)

1. SCOPE OF CONTRACT: The intent of this solicitation is to obtain competitive quotations to provide the Metropolitan Washington Airports Authority with a 150HP portable rental steam boiler system for a period of 7 months. 2. SCOPE OF WORK: The contractor shall provide all adequate supervision, manpower, expertise, and technical service necessary for the safe operation of a 150 hp portable rental steam boiler system mounted and piped in an enclosed trailer consisting of the following components: 1. A fire tube gas-fired boiler with operation use set at 45lbs steam pressure with a burner that shall be for natural gas minimum pressure requirement of 2psig (56 W.C.) to the gas pressure regulator of boiler. Electrical requirement shall Be 100 amps service rated at 208V/3ph/60Hz. 2. A duplex packaged feed water system with two feed water pumps, feed water/condensate/chemical feed tank with steam pre-heater assembly. 3. One packaged water softener with brine tank/softener tank with makeup feed system. 4. One bottom blow down tank to include after cooler assembly. 5. One boiler tandem bottom blow down valve set. The contractor shall also provide safe parking and leveling. The technical service shall include but limited to burner service, controls maintenance inspections, boiler preventive maintenance, operational maintenance inspections, emergency service rates, start-up and testing, pictures of boiler interior prior to testing, and china (rain) cap for boiler stack. SPECIFICATIONS: 1. High-pressure steam boiler to be gas-oil fired with gas as primary fuel. Size to be 150 HP 2. Mounted on total enclosed trailer, or meet the following: A. Capable of enclosing controls and forced draft gas for inlet B. Total and completely weather tight and meant for outside use 3. Trailerized boiler shall be the plant. It shall be equipped with deaerator and boiler feed pumps, condensate tank/makeup tank with steam pre-heater assembly, chemical feed system, gas-oil piping and valves, forced draft system, and all operating controls for automatic operation. System shall have capability to operate steam system at 150 psi for continuous use. (Set at 45psi) 4. Trailer and equipment use shall not exceed 48 long and 8 wide. 5. Transport, setup, and start up of equipment shall be included in contract price. However, all connections to the existing building steam system will be by others. Start-up will occur approximately 2-3 weeks after delivery. Set up to include blocking up and securing the trailer. 6. The owner is responsible to start-up the boiler, bring up to operating range and ensure automatic operation of all equipment including boiler and auxiliaries. Any malfunctioning components shall be corrected. Page 2 of 5

7. The owner shall provide the following information: A. History of use: B. History of repairs C. Year, Make, Model, of equipment D. Current Virginia State Inspection Certification: E. Any applicable test performed on the pressure vessel: 8. The Authority requires that the suppliers be capable of replacing the boiler on short notice in the event of failure to the boiler where as repairs cannot be made immediately. 9. Final acceptance is subject to the repairs made to all defects noted during start-up and those noted by our insurance carrier. 10. The Authority agrees to provide operational services, water treatment and analysis, preventive maintenance services. PM to include leak detection on all equipment, valve packing, small replacements, greasing, lubricating and cleaning of parts and equipment. 11. The boiler and equipment will only be required for October 1, 2011 through April 1, 2011(7 months annually), and the contract shall be based on those months. However; if heat is still required in May the 8 th month shall be added at the Authority s option. 12. Removal of the equipment shall be included in contract price. Disconnect of all external connections will be done by others. The contractor must remove all equipment within a seven (7) day period of official notification of such by the Authority. 3. APPLICABLE CLAUSES: 3.1 PREPARATION FOR SHIPMENT The supplies shall be packaged and packed for shipment in accordance with manufacturer's standard commercial practice in a manner that will ensure proper and safe delivery to destination. 3.2 DELIVERY The supplies shall be delivered F.O.B. DESTINATION to the Metropolitan Washington Airports Authority, not later than 20 Calendar days after receipt of order. When an earlier delivery schedule is offered, the Authority reserves the right to award the contract in accordance with the schedule offered by the quoter. If the quoter offers no delivery schedule of his own, the Authority's schedule stated above will apply. DELIVERY ADDRESS: DELIVERY HOURS: Metropolitan Washington Airports Authority Ronald Reagan Washington National Airport Warehouse Building, MA-134 Washington, DC 20001 8:00 A.M. TO 3:30 P.M., Monday through Friday, except federal holidays. 3.3 ALTERNATE DELIVERY In the event satisfactory quotations are not received in accordance with the Authority's Delivery schedule, alternate quotations will be considered and award made as determined to be in the best interest of the Page 3 of 5

Authority, price and other factors considered. Therefore, if quoting on an alternate delivery, Quoters must state that earliest possible delivery schedule they can guarantee to the Authority. QUOTER S PROPOSED DELIVERY SCHEDULE QUOTER WILL DELIVER F.O.B. DESTINATION WITHIN CALENDAR DAYS AFTER RECEIPT OF AN ORDER. 3.4 INSPECTION AND ACCEPTANCE Final inspection and acceptance will be made at DESTINATION by responsible Metropolitan Washington Airports Authority personnel. 3.5 FACSIMILE QUOTATIONS Definition: "Facsimile Quotation", as used in this solicitation, means a quotation, modification of a quotation, or withdrawal of a quotation that is transmitted to and received by the Authority via electronic equipment that communicates and reproduces both printed and handwritten material. Quoters may submit facsimile quotation as responses to this solicitation. The response must arrive at the place and by the time, specified in the solicitation. Facsimile quotation that fail to furnish required representations or information or that reject any of the terms, conditions, and provisions of the solicitation may be excluded from consideration. Facsimile quotations must contain the required signatures. The Authority reserves the right to make award solely on the facsimile quotation; however, the entire, completed original signed quotation must be submitted. Facsimile receiving data and compatibility characteristics are as follows: 1. Fax number (703) 417-8438 2. Compatibility characteristics of receiving facsimile equipment Model: Canon 7500 -receiving speed: ECM 3 seconds per page If the quoter chooses to transmit a facsimile quotation, the Authority will not be responsible for any failure attributable to the transmission or receipt of the facsimile quotation including, but not limited to, the following: 1. Receipt of garbled or incomplete quotation. 2. Availability or condition of the receiving facsimile equipment. 3. Incompatibility between the sending and receiving equipment. 4. Delay in transmission or receipt of quotation. 5. Failure of the quoter to properly identify the quotation. 6. Illegibility of quotation. Page 4 of 5

REQUEST FOR QUOTATION PRICING SCHEDULE NAME OF OFFEROR OR CONTRACTOR SOLICITATION OR CONTRACT NUMBER PAGE 5 of 5 ITEM NO. SUPPLIES/SERVICES QTY UNIT UNIT PRICE AMOUNT SCOPE OF WORK: The Contractor shall provide all adequate supervision, manpower, expertise, and technical service necessary for the safe operation of a 150 H.P portable rental steam boiler system for a period of seven (7) months mounted and piped in an enclosed trailer for Ronald Reagan Washington National Airport. A. Pricing (October 1, 2011 April 1, 2012) Rental of Temporary Steam Boiler Per Month Total Price Per Month 7 Month $ $ Total Price $ BASIS OF AWARD: Award will be made to the lowest, responsible Offeror whose quotation is in conformance with the solicitation. MWAA Form PR-15