Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
|
|
|
- Francis Booker
- 9 years ago
- Views:
Transcription
1 Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM Ensure that all services are correctly connected and all three phase motors will run in the correct direction. Ensure that there is an adequate air supply to the burner and the exhaust is not restricted. 2. Close blow down valve under Boiler. 3. Close Main stop valve. 4. Open air cock. 5. Switch on main isolator on panel, POWER light will be illuminated and alarm bells will ring. 6. Mute alarm with push button. 7. First and second low lights will stay on because boiler is empty of water. 8. Press START / RESET button. 9. Switch feed pump to AUTO. 10. Boiler will fill with water, as level rises first and second low lights will become extinguished. 11. When first low light is extinguished press START / RESET push button again. 12. When water reaches working level feed pump will stop. 13. Level in sight glass should show between 1/2 and 2/3 full 14. Switch burner to ON, burner light will be illuminated and burner will start pre-fire cycle. 15. Burner will fire. 16. Check fuel pressure on oil fired units, reading should be between Bar depending on type of Burner. 17. Fire the Boiler for intervals of 10 mins on and 10 mins off until the steam pressure gauge shows 50 psig. During this period blow boiler down to maintain correct working water level. 18. Close the air cock, the Boiler is now ready for use. 19. The pressure may be increased to the required working pressure by continuous firing and the stop valve opened slowly to service
2 Guide to Commissioning Boilers 1. Siting a: The Boiler must be placed on a flat level surface. b: Fuel tank and water tank are to be raised to give a positive supply to the fuel and water pumps. c: Ensure that the Flue gasses are not obstructed. d: Adequate weather protection to be given to the equipment. 2. Connecting Services a: Check that the correct power supply is used. b: Pipework between the fuel tank to pump filter and water tank to water pump is not to be reduced. Avoid any bends or restrictions. c: Check the fuel supply is the correct grade. d: Any water softening equipment MUST be connected into the system, 3. Operating Pre Run Checks a: Check water supply to softener, water is soft and the feed tank is full. b: Prime the water pump. c: Check the fuel supply to burner. d: Prime the fuel pump. e: Check power supply and motor direction. Operating checks Low Fire 1. Fire the boiler, blow down 1/2 of water at 3 minute intervals until working pressure is reached. This will circulate the heat in the shell. Close air cock as required. 2. When at working pressure - Put Boiler on Auto / High / Low 3. Blow down the Gauge Glasses and main Boiler blow down 4 hourly Boiler blow down - Blow 1 of water. 4. When the Boiler is off hired - open the blow down and empty.
3 Maintenance and Testing of Water Guages It is Dangerous to operate a steam boiler unless the water gauge or gauges are in good order and the true level of the water within the boiler can be observed at all times. Personnel in charge of boiler plant should be familiar with the operation and testing of the water Gauges. Testing water Gauges directly attached to Boiler The objects of testing are to ensure that there is a clear steam way at the top and also a clear water way at the bottom. With ordinary water gauges the procedure is as follows Open the drain cock (D) allowing a clear blow through of steam and water. Close the steam cock (S). There should be a clear blow through of water, thus testing the water passage. Open the steam cock (S) and close the water cock (W). There should be a clear blow through of steam., thus testing the steam passage. Close the drain cock (D), thus allowing the water gauge to first be filled with steam. Open the water cock (W) and allow the water to return to the proper level in the glass. Check that all cocks are set correctly. Sequence of Operation. 1: Open Drain Cock (D) 2: Close Steam Cock (S) 3: Open Steam Cock (S) 4: Close Water Cock (W) 5: Close Drain Cock (D) 6: Open Water Cock (W) 7: Check that all cocks are set correctly Water Gauges should be tested at least twice each 8 hours shift The Authorised attendant should systematically test the water gauges several times a day and should be provided with suitable protection for the face and hands, as a safeguard against scalding in the event of breakage of glasses Water Gauge Glass Guards The water gauge glass guard should be kept clean. When the guard is being cleaned in place, or removed for cleaning, the water gauge should be temporarily shut off. Make sure there is a satisfactory water level before shutting off the gauge and take care not to touch or knock the water gauge glass. After cleaning, and when the guard has been replaced, the water gauge should be tested and the cocks set in the correct positions. Maintenance The water gauge should be thoroughly overhauled at each annual survey. Lack of maintenance can result in hardening of packings and seizure of cocks. If a cock handle becomes bent or distorted special care is necessary to ensure that the cock is set to full open. A damaged fitting should be replaced or repaired. Water gauge glasses often become discoloured due to water conditions, also they become thin and worn due to erosion. Glasses, therefore, should be renewed at regular intervals. A stock of spare glasses and cone packings should always be on hand. Remember that if the Steam passages are choked a false high water level may be given in the gauge glass. After the gauge has been tested a false high water level may still be indicated. If the Water Passages are choked a false high or low water level may show in the glass. After the glass has been tested it will remain empty for a time unless the actual water level is dangerously high. If the water gauge is connected to a hollow column, when testing the water gauge steam connections, any cock on the connected steam pipe should be closed with the water gauge steam cock and when testing the water guage water connections,any cock on the connected steam pipe should be closed with the water gauge steam cock the Water Gauges should be Well Illuminated
4 Standard Terms & Conditions for the Hire of Shell Type Boilers 1. Hire Rates are based on a minimum period of 1 week or as otherwise stated in our official quotation. 2. Hire charges commence from the date of despatch from our Lye works and payment to be made on receipt of our invoice. 3. A Minimum of 24 hours notice is to be given by the customer for the termination of hire. 4. The customer is responsible for the offloading and loading of our equipment on site unless otherwise agreed in writing. 5. The customer is responsible for ensuring free access on site for transport and crane and for a level hardstanding suitable for accepting the operational weight of a Boiler. 6. Delivery and collection charges will be in accordance with the rates specified in out original quotation. 7. In the event of Boiler failure for whatever reason Bradlee Boilers Ltd must be contacted before any involvement from a third party. Visits requested by the customer during the hire period will be charged to the customer in all cases where evidence is available to show that the failure occurred due to any other reason other than where such visits are occasioned by design, manufacture, workmanship faults or any other reason occasioned by the actions or default of. 7a. The responsibility for failure will be determined at the time of our visit and written agreement will be required by the customers representative. 8. The customer is to arrange for a competent qualified engineer to be available to carry out all daily maintenance procedures as instructed by our commissioning engineer. 8a. Bradlee Boilers service Department will accept emergency breakdown calls between 0800 hrs hrs Monday to Friday. For extended holiday periods, i.e Christmas/New Year the customer can apply for emergency telephone numbers of the duty service engineer. 8b. A Full 24 hour emergency service is not available except by prior written agreement and will only cover periods of up to three days duration in each case. 9. The customer is responsible for the provision of fuel, water treatment chemicals and electrical supplies to our Boiler Unless otherwise agreed in writing. 10. For Burners requiring pilot ignition the customer is responsible for the supply of natural gas or bottled gas supplies. 11. Feed water treatment is the responsibility of the customer using a recognised national companies treatment system. The customer is responsible for any damage to the Boiler and for descaling deposits within the waterways caused by incorrect water treatment. 12. A copy of the insurance certificate will be supplied with each Boiler.
5 Standard Terms & Conditions for the Hire of Shell Type Boilers ( Continued) 12a The customer is to insure through their own insurance company for: 1. Loss or damage to our plant by fire, explosion, frost, or theft. 2. Damage to property belonging to the customer or for which he is responsible. 3. Legal liability for damage to property belonging to the customer or for which he is responsible, directly consequent upon and solely due to explosion collapse or damage to the plant. 4. Legal liability for injury to any person or persons other than the customer and his or her employee. 5. The hirer does indemnify Bradlee Boilers Ltd against direct or consequential losses or third party liability suffered by Bradlee Boilers Ltd. We Bradlee Boilers Ltd cannot hold ourselves responsible in any shape or form for losses either direct or consequential as a result of our activities. 13. The customer is to provide adequate protection from the weather and to accept full responsibility for any failure in this respect. 14. The Boilers in our quotation are based on a equivalent evaporation from at 212oF and is an expression of the thermal rating converting the variables of feed water temperature and steam conditions to an accepted standard. It is the customers final responsibility to ensure that the boilers offered in our quotation are of adequate capacity when the site feed water temperature and pressure conditions are taken into consideration.
6 Important Notice to all Users of Steam Raising Plant and Associated Equipment hired to them by Bradlee Boilers Ltd Statutory Instrument No Health & Safety The pressure systems and transportable gas containers regulations 1989 Part III Pressure Systems Your Attention is drawn to the section relating to operation 11-2 which states: The user of a pressure system shall ensure that it is not operated except in accordance with the instructions provided in respect of that system.
7 Statutory Instrument No The Pressure systems and transportable gas containers regulations 1989 Steam Raising Plant and Associated Equipment Hired By Bradlee Boilers Ltd In Accordance with the requirements of the above regulations part III ( Pressure systems) Section II ( Operation ) it is the responsibility of the plant owners to provide for any person operating the system adequate and suitable instructions for: (a) The safe operation of the system and (b) The action to be taken in the event of an emergency. It is therefore important that the following information is made available to all users of Bradlee Boilers Ltd Equipment.
8 Instructions for the safe operation of the System 1. Condition of Plant Suitable for Safe Operation When taking delivery, ensure that the equipment is sound and in good order and had not suffered any damage during Transit. Damage to water level sight glasses, safety valves and similar equipment can result in unsafe operation of the plant. (If in doubt notify the owners immediately) 2. Siting Steam Boilers rely on correct water levels for safe operation. Ensure that the boiler is placed on a level and stable standing. Temporary standing should not be affected by any subsequent climatic conditions i.e high rain falls. 3. Electricity Supply Ensure the correct electricity supply is available and that the requirements of suitable neutrals and earths are complied with. It is recommended that all electrical supply connections be carried out by fully qualified personnel and that the installation be in strict accordance with the necessary electrical safety standards. All three phase motors must be checked for correct rotation. 4. Fuel Supply The Quality of Fuel should be in accordance with that specified by the owners and all feed pipes and tanks to be installed in such a manner to prevent fire or hazards to operating personnel. 5. Commissioning Commissioning must be carried out in strict accordance with the owners instructions and any defects notified immediately. As supplied the equipment is in good order and safe to operate, however it is the responsibility of the user to ensure that correct and safe commissioning is carried out and subsequent day to day operation is safe and without hazard. Should the user be unable to accept such responsibility the owners must be informed immediately 6. Normal Operation Detailed operational instructions are supplied with each item of equipment and the plant should be operated in accordance with these. On no account operate at higher pressures then the working pressure shown on the Plant In relation to the safe operation of steam boilers particular attention must be paid to water level sight glasses and water level controls. 7. Water Level Sight Glass Gauges Details relating to the correct operation and maintenance of these items is supplied with the boiler and should be strictly adhered to. It is important that water gauges are tested at least once every 24 hours and where shift working is in progress every shift
9 8. Water Level Controls Details relating to the testing of this equipment is supplied with the Boiler It is Important that the water level is lowered every 24 hours and the controls tested to ensure continued safe operation of the boiler. Any defect should be notified to the owners immediately. 9. Records When possible it is recommended daily records be kept relating to plant operation particularly in relation to safety tests carried out. Such information will show trends relating to a change of operation or any possible faults developing within the plant. The keeping of such records helps to enforce the discipline of daily testing and greatly assist if problems occur. 10. Associated Documentation The following documents should be read in conjunction with these notes. 1. Guide to Commissioning Boilers 2. Instructions for starting up Bradlee Hire Boilers from Cold. 3. Maintenance and testing of water gauges. 4. Testing of water level controls. 5. H.S.E Guidance note PM5 6. Standard terms and conditions for the hire of shell type boilers 7. The action to be taken in the event of an emergency
10 The Action to be Taken in the Event of an Emergency 1. Disconnect Equipment from Electricity Supply 2. Disconnect or Isolate Equipment from Fuel Supply 3. Keep Personnel away from hazardous area 4. Inform owners as soon as possible giving as much information as possible
11 Test Procedure for Checking Bradlee Type Boiler Water Level Controls 1. Switch the feed pump OFF The following tests should be carried out under normal steaming conditions 2. Open blow down valve and allow water level to drop with burner firing. 3. When water level reaches first low level burner will be extinguished and first low level indicator light will be illuminated together with audible warning press mute button to stop bell. 4. Allow water level to fall down to second low level when second low level indicator light will be illuminated, together with audible warning - press mute button to stop bell. 5. Close blow down valve. 6. Switch feed pump to Auto and observe rising water level. when water recovers above first second low - light will extinguish 7. Continue to observe rising water level, when water recovers above first low - light will extinguish and burner will refire. 8. Continue to observe rising water until normal working level is reached when pump will automatically stop. 9. Press Reset Button. 10. Boiler will now be returned to normal operation.
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
Routine and Emergency Boiler Operation
Routine and Emergency Boiler Operation Learning Outcome When you complete this module you will be able to: Describe the routine safe and efficient operation of a packaged boiler. Learning Objectives Here
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant
Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Safe management of industrial steam and
Look after your boiler so it can look after you
Look after your boiler so it can look after you This guide covers the steps you can take to ensure that your Vokèra boiler continues to operate efficiently and safely. No-one knows your boiler better than
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
HomeServices Terms and Conditions
HomeServices Terms and Conditions Contents Definitions 03 The Contract 04 Start date 04 General Exclusions 11 Payment 12 Cancellation 13 Appointments 16 Product Renewal 16 Changes to contract 16 Safety
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
HOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
Boiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
REQUEST FOR QUOTATIONS
Metropolitan Washington Airports Authority Materials Management, MA-133 Terminal A, Room 278 Washington, DC 20001-4901 REQUEST FOR QUOTATIONS 1. FOR INFORMATION CONTACT NAME: Regina Leigh 2. REQUEST FOR
service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear
3in1 Plan Dear As per our recent conversation, the SGS Service Plan offers complete peace of mind because for a small premium your central heating equipment will be serviced and covered in the event of
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Please read and keep these instructions. Run water through your machine before first use
47070 Rev 1 24/3/05 2:23 PM Page 1 12 cup filter coffee maker Please read and keep these instructions getting the best from your new coffee maker Safety first Caution must be used when handling hot water,
COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23
COMMERCIAL REPORT / STOCK CONDITION SURVEY For Sydenham Hill Estate Sydenham Hill London SE 23 Submission Prepared by Gas Advisory Services Limited Date: 4 th June 2013 Gas Advisory Services Limited Phoenix
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Getting the best from your urn
444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual
QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Chicago Stationary Engineer Licensure Examination Information
Chicago Stationary Engineer Licensure Examination Information This candidate guide should help you prepare for the Chicago Stationary Engineer licensure examination. Part I contains general information
1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
VW Camper Van Hire, Pembrokeshire, Wales. Booking can be arranged through the website, email, or telephone call.
Terms and Conditions of Hire Our aim is to provide customers with a vehicle in prime condition so you can have the best, relaxing holiday you wish for. Here are our terms and conditions of hire. Booking
Risk Engineering Guideline
www.hdi.global HDI Risk Consulting Risk Engineering Guideline Impairment of fire protection systems Basic protection systems should not be impaired without adequate replace compensation with provisions.
Operating instructions
Operating instructions Gas condensing boilers MGK-130 MGK-170 MGK-210 MGK-250 MGK-300 Wolf GmbH Postfach 1380 D-84048 Mainburg Tel. +49 8751/74-0 Fax +49 8751/741600 Internet: www.wolf-heiztechnik.de Document
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website www.iomfire.com
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK Website www.iomfire.com ADDRESS OF PREMISES FIRE CERTIFICATE No. (where applicable).. LOCATION OF LOG BOOK. CONTENTS OF LOG BOOK Useful telephone
3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: [email protected] Website: www.kellogg-american.com
Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor
the Soft Top Breville Customer Service Center www.breville.com Instruction Book - Livret d instructions
Breville Customer Service Center the Soft Top Instruction Book - Livret d instructions US Customers Mail: Breville USA 19400 S. Western Ave Torrance CA CA 90501-1119 Phone: Customer Service 1 (866) BREVILLE
Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
BoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
Restaurant & café guide
'Helping our customers stay in business by reducing risk' NZI Risk Solutions TM About NZI Risk Solutions NZI has extensive experience in providing expert risk management advice to help our commercial customers
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
Cowley Resident Management Organisation Ltd Cowley House, 147 Brixton Road London SW9 6LZ
Cowley Resident Management Organisation Ltd Cowley House, 147 Brixton Road London SW9 6LZ Tel: 020-7926 0690 Fax 020-7926 0692 www.cowleyrmo.org Gas Central Heating Contract for Homeowners Basic Service
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product
Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.
Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement. The benefits of a Home Service Agreement Provides peace of mind Regularly scheduled maintenance will keep
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Service Level Agreement/Specification
Service Level Agreement/Specification For Maintenance and Associated Risk Management Services at New College Campus and Associated properties May 2007 INDEX 1. SCOPE 2. MAINTENANCE SERVICE LEVELS a. Staffing
Energy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
Your Boiler Room: A Time Bomb?
Your Boiler Room: A Time Bomb? Is you boiler room a potential Time Bomb? A few basics you need to know to work safely in the boiler room: Two potentials for explosions in a boiler room: Water/steam side
2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL 'J' SERIES - GAS FIRED STEAM BOILERS (6J - 60J)
INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL 'J' SERIES - GAS FIRED STEAM BOILERS (6J - 60J) This Manual must be available to the boiler operator at all times. JGAS-E-10 2008 In case of Emergency
Vaillant s plain English guide to. simple, concise and precise
Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers Table of Contents Introduction... 1 Intention... 2 Authority and responsibility letter... 3 Organizational
DEALING WITH PLUMBING AND HEATING EMERGENCIES
DEALING WITH PLUMBING AND HEATING EMERGENCIES This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential
Hot Water Urns. all models. Helpline. v3.0
Hot Water Urns all models Helpline 01384 573999 instructions.indd 1 v3.0 02/06/2014 14:50 IMPORTANT INFORMATION - RETAIN FOR FUTURE USE When using any electrical appliance, basic safety precautions should
Winnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
Landlord Insurance. Summary of cover
Landlord Insurance Summary of cover March 2013 Why choose AXA s Landlord Insurance policy? The Landlord Insurance offers a range of covers and caters for a variety of customers, from individuals who own
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustrations in this book.
Kambrook 461 Plummer Street, Port Melbourne 3207, Australia Customer Service Line (free call) 1800 800 634 Customer Service Fax 1800 621 337 Kambrook New Zealand, Private Bag 94411, Greenmount, Auckland,
Landlord Insurance. Summary of cover. October 2013. 35039_ACLD0520ZB_BRO_A5.indd 1 23/10/2013 16:20
Landlord Insurance Summary of cover October 2013 35039_ACLD0520ZB_BRO_A5.indd 1 23/10/2013 16:20 Why choose AXA s Landlord Insurance policy? The Landlord Insurance offers a range of covers and caters for
Restaurant and Café Risk Management Guide. Don t Risk It!
property & liability Restaurant and Café Risk Management Guide Don t Risk It! About Lumley Insurance Lumley Insurance has extensive experience in restaurant insurance and risk management. This experience
The client organisation that was best at meeting residents needs in the provision of a maintenance service
Wolverhampton Homes NHMF Best Practice Awards 2009 Submission for: - The client organisation that was best at meeting residents needs in the provision of a maintenance service Leaseholders gas maintenance
How To Handle An Emergency At A Strata Corporation
24 HOUR ANSWERING SERVICE The regular office hours at our firm are 9:00 am to 5:00 pm Monday to Friday. After these regular hours, the same telephone number is answered by a Telephone Answering Service,
User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII
MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII Operator s Manual INTRODUCTION Thank you for selecting this power washer from Simpson. Your power washer has been manufactured using the most advanced components
OPTIMA TRADE PLUS SUMMARY OF COVER
ABC OPTIMA TRADE PLUS SUMMARY OF COVER This document provides a guide to the cover provided. It is however only a summary of the terms of cover and does not contain full details of the insurance policy
Guidance on Safe Operation of Boilers
Guidance on Safe Operation of Boilers Ref: BG01 A joint document by the Safety Assessment Federation and Combustion Engineering Association produced in consultation with the Health & Safety Executive.
Call us toll free at: 1-800-GEVALIA (1-800-438-2542)
LIMITED WARRANTY: This appliance shall be free from defects in materials and workmanship under normal home use for a period of one year from the date of receipt. During that period, defects will be repaired
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
SPECIAL CLAUSES/WARRANTIES THESE ARE OPERATIVE ONLY IF SHOWN IN THE SCHEDULE OR IN AN ENDORSEMENTFORMING PART OF THE SCHEDULE
SPECIAL CLAUSES/WARRANTIES THESE ARE OPERATIVE ONLY IF SHOWN IN THE SCHEDULE OR IN AN ENDORSEMENTFORMING PART OF THE SCHEDULE CL2 - Pipe and Tank Lagging Warranty Underwriters will not be liable for loss
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales SPECIFICATION FOR LAUNDRY EQUIPMENT MAINTENANCE Maintenance Module 32 March 2011 issue This document has been compiled by the Engineering
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
How to use your Water Heater
How to use your Water Heater Infinity 32 HD 250 E Infinity 26 HD 200 E Infinity 26 Internal HD 200 I Infinity 24 Your installer is responsible for correct installation. Installation instructions are located
Owner s Guide and Installation Instructions
Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 874, 876 series 612 to 620, E16 models This water heater must be installed and serviced by a qualified person. Please leave
Administered on behalf of your dealer by: Gold Dealer Care Extended Guarantee Effective from 20/05/2015
Administered on behalf of your dealer by: Gold Dealer Care Extended Guarantee Effective from 20/05/2015 2 Contents Section Page Contents... 2 Welcome... 3 Gold Guarantee... 4 Optional additional items...
Boiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
GREENSTAR HEATSLAVE 12/18, 18/25, 25/32
8 716 106 253f 30/3/10 12:59 Page 1 USER INSTRUCTIONS & CUSTOMER CARE GUIDE FLOOR STANDING OIL FIRED CONDENSING COMBINATION BOILER CONVENTIONAL FLUE & ROOM SEALED FLUE GREENSTAR HEATSLAVE 12/18, 18/25,
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives
DOCUMENT: ECSEQ6-0 EFFECTIVE: 09/23/10 SUPERSEDES: Operational Overview and Controls Guide Two or Three Pump IronHeart Lite with Variable Frequency Drives 6700 Best Friend Road. Norcross, GA 30071. (770)
Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service
Housing Solutions Limited Terms and Conditions Fixmy Boiler Service Housing Solutions Limited Crown House, Crown Square Waldeck Road Maidenhead SL6 8BY Tel: 0800 876 6060 Web: www.fixmy.org.uk Terms and
A Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
Continuous Flow Water Heaters
Operation Manual Continuous Flow Water Heaters For Rinnai continuous flow water heaters manufactured from 2010 onwards (serial number 09.12 xxxxxx) Internal Rinnai continuous flow water heaters must be
PACKAGED FIRE TUBE BOILER
SAMPLE PREVENTIVE MAINTENANCE MANUAL PACKAGED FIRE TUBE BOILER 1 CONTENTS Introduction 1 Intention 2 Organisational setup 3 Boiler Fault reporting & Repair progression 4 Preventive Maintenance Schedules
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety