Ocean Engineering Technical Data Sheet Stuffing Tubes



Similar documents
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

50 TO 60 INSTALLATION INSTRUCTIONS v1.0

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation Instructions

Flue Installation. High Efficiency Condensing Boilers

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Fiberstars Lighted Laminar Flow Fountain Installation Manual

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

with installation dynafact boost GAUGE this manual is for use with systems

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

INSTALLATION OF A BAY WINDOW

Installation Instructions S

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

AM/FM ANTENNA RELOCATION KIT

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

Build Your Own Solar Car Teach build learn renewable Energy! Page 1 of 1

MGB Chrome Bumper Conversion

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Installation Instructions

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

How To Replace A Reverse Osmosis Water Tank

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

INSTALLATION INSTRUCTIONS BL-8704

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Carlon Carflex Liquidtight Flexible Tubing

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

REPAIR AND MAINTENANCE MANUAL

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

INSTALLATION INSTRUCTIONS MK-8704

ILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

AMPSEAL* Automotive Plug Connector and Header Assembly

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

Beautifully Traditional

Installation guide Nordic mixer taps. Before installing read this guide first

2100 AD Mirror Elevator Ball Nut Replacement Procedure

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

HOME GYM. Model. Retain This Manual for Reference OWNER'S MANUAL.

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Fixtures - Parts - Accessories to shampoo bowls

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

MODEL G300 BRAKE BLEEDER

9,000lb capacity 4 Post Lift Installation Manual

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Post Mount Light Installation*

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

CHROME FRONT BRAKE MASTER CYLINDER KIT

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Pipe Thread Types and Designations

NELSON HEAT TRACING SYSTEMS

ALBINS SEQUENTIAL SHIFTER

Installation of Rear View Camera in a 1995 Roadtrek 190 Popular

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Installation Instructions for Water Methanol Stage 1

Watts Pure Water Systems

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

WAVELET WATER QUALITY MONITORING KIT

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at


Arctic Leash Instruction Manual Alaskan Products Company LLC.

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Suzuki Katana Fender Eliminator

TY-FLO Needle Valves

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

Rollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Step by step guide to installing your own Ku Band satellite dish

Installation Instructions

Your safety and the safety of others are very important.

TSP-LL2 Magnetostrictive Probe

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Standard Sleep Pod Side Entry Assembly Instructions

Industrial Strength Rocket Launcher

Installation Instructions

Stainless Steel Single and Dual Circulation Kits

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS

Transcription:

Ocean Engineering Technical Data Sheet Stuffing Tubes Stuffing tubes are devices used to allow a wire or cable to pass through a wall or bulkhead and protect components from the outside environment. Many units have problems selecting the right stuffing tube or assembling them correctly which leads to component failure due to moisture intrusion. The following is a primer on stuffing tubes. One of the most important tasks is identifying the type of stuffing tube to use. Thin-wall bulkheads (up to 3/16 thick with through holes) like enclosures or boxes use the straight-through models. Thick wall bulkheads (3/16 or thicker with tapped holes) use the NPT model (NPT stands for American Standard Taper Pipe Threads) like lantern bases, range lights, etc. The correct stuffing tube must be used or it will leak. NPT stuffing tubes can not be used in thin boxes with through holes and a nut to secure them (I have seen this happen). A box using a NPT stuffing tube will always have a threaded hole. The watertight seal is maintained by the interference fit of the tapered pipe threads. Wall Thickness: 3/16 3/4 NPT or Lantern NPT Stuffing Tube Likewise, a straight-through stuffing tube can not be used in a threaded hole. The watertight seal is maintained by an O-ring sandwiched between the locknut, body and enclosure. Wall Thickness 3/16 Max. Straight Through Stuffing Tube You have to select a stuffing tube that fits the enclosure and can accept the packing assembly for the cable passing through it. Both versions of stuffing tubes come in many sizes; we generally use only use three sizes, as detailed on the next page:

Dorn Equipment Corporation Stuffing Tubes (available via MILSTRIP) Cable Range Hole Size Size Style (jacket outside diameter) (diameter or NPT) NSN 5975-00- 1 Straight* 0.077 0.296 0.885 296-4092 1 NPT 0.077 0.296 ½ NPT 808-4063 2 Straight* 0.275 0.472 1.010 296-4093 2 NPT 0.275 0.472 ¾ NPT 808-4064 4 Straight* 0.450 0.777 1.260 296-4095 4T Straight* 0.450 0.777 1.385 989-5046 4T NPT 0.450 0.777 1 NPT 892-9259 Dorn stuffing tubes have the size imprinted on the cap. * Straight Stuffing Tubes do not come with an ; see last page. The packing assembly is the heart of the stuffing tube. They are not included with stuffing tubes and must be ordered separately. The packing must be correctly sized to tightly grip the cable. Determine the outside diameter of the cable using a set of dial calipers. If none are available, use a ruler to approximate the diameter to a 32 nd of an inch. Convert to decimal using the chart below and find a packing assembly to fit the stuffing tube. Decimal Equivalents 1/4 0.250 3/8 0.375 1/2 0.500 5/8 0.625 9/32 0.281 13/32 0.406 17/32 0.531 21/32 0.656 5/16 0.313 7/16 0.438 9/16 0.563 11/16 0.688 11/32 0.344 15/32 0.469 19/32 0.594 23/32 0.719 Each stuffing tube assembly uses a range of packings to accommodate the different cable sizes *. The correct packing must be used because if it s too large it will not seal around the cable and if it s too small it will be difficult to slide over the jacket. Assemblies for Size 1 Stuffing Tubes Cable Range NSN 1A 0.137-0.187 202-2580 1A1 0.077-0.127 202-2581 1A2 0.100-0.150 202-2582 1B 0.184-0.234 202-2583 1B1 0.228-0.278 202-2594 1C 0.244-0.296 202-2585 Assemblies for Size 2 Stuffing Tubes Cable Range NSN 2A 0.275-0.325 202-2586 2B 0.317-0.367 202-2587 2C 0.340-0.390 202-2588 2D 0.375-0.425 202-2589 2E 0.422-0.472 202-2590 * Size 3 stuffing tubes are not used because they have a very limited range. Many of our enclosures contain Size 2 stuffing tubes, and our lanterns are tapped for 3/4 NPT threads which require a Size 2 stuffing tube. However, our standard solar panel wire is smaller (0.240 ) than the range specified for a 2A packing assembly, but the packing will compress and seal around this wire. Continue to use Size 2 stuffing tubes in marine lanterns and Size 1 for new

bulkhead enclosures and apparatus with a ½ NPT threads when sealing solar panel cable. An alternative for NPT applications is to use the Tideland NavGrip cable gland, discussed below. Other Sources. Assemblies for Size 4 & 4T Stuffing Tubes Cable Range NSN 4A 0.450-0.500 202-2591 4B 0.497-0.547 202-2592 4C 0.534-0.584 202-2593 4D 0.559-0.609 202-2594 4E 0.610-0.665 202-2595 4E1 0.650-0.700 202-2596 4F 0.669-0.719 202-2597 4F 0.710-0.760 202-2598 4G 0.727-0.777 202-2599 Tideland Signal Corporation manufactures its own line of stuffing tubes called NavGrip/GMU Cable Glands. They are only available in the NPT version for 3/16 or thicker threaded enclosures/lanterns. Glands and replacement grommets (packing) may be purchased via Tideland s GSA schedule: GS-07F- 6104P, phone: 337-269-9113, website: www.tidelandsignal.com. Assembly. Tideland NavGrip/GMU Cable Glands Cable Cable Gland & Replacement Gland Size Cable Range Grommet Assy Grommet Assy 3/4 NPT 0.250 0.375 620.1004-04 303.1071-04 3/4 NPT 0.375 0.500 620.1004-02 303.1071-02 3/4 NPT 0.500 0.625 620.1004-01 303.1071-01 3/4 NPT 0.625 0.750 620.1004-03 303.1071-03 (1/2 NPT sizes are also available). Correct assembly of the stuffing tube is very important to ensure a leak-free seal. For NPT stuffing tubes, Teflon tape or pipe joint compound should be used to seal the threads between the stuffing tube and housing. Tapered pipe threads will tighten as the stuffing tube is inserted, so tighten gradually, but firmly to seat the threads. Likewise, the straight-through stuffing tube must be installed properly. First, remove the cap and then the locknut. Slide the O-ring off the body of the tube and insert it through the hole from inside the enclosure. The hole in the enclosure must be sized properly and free of burrs. Slide the O-ring over the body against the outside of the enclosure, screw on the locknut and tighten using a spanner wrench (McMaster-Carr is a good source for spanner wrenches), as shown below:

. The packing assembly is the most important component of the stuffing tube, and often installed incorrectly. First, determine the wire size, then which size stuffing tube is being used (size 1, 2, 4) and then choose the correct packing/gland assembly. Dorn assemblies come packaged in a small envelope and contain the rubber packing and three plastic washers (Tideland glands only have one washer). Two of the washers are the same size, one may be smaller. The smaller washer is inserted into the stuffing tube first to prevent the packing from being squeezed through the body. The two same-sized washers are installed on top of the packing beneath the cap. For Tideland s NavGrip glands, only one washer is used between the cap and grommet (packing). The washers are very important because as the cap is tightened, they slip and prevent the packing from twisting. If the packing twists, voids will be made along the wire allowing water to wick into the enclosure. The packing is installed the same for both the straight-through and NPT stuffing tubes, as shown below: Cable Drip Loop The cap should be tightened so that the cable can not be forcibly pulled or pushed through the packing. A drip loop will prevent water from traveling down the outside of the cable and gathering on the stuffing tube. Additionally, water can travel inside the cable into the enclosure if the jacket is cut or the opposite end is not terminated properly. Unique problems. If you have unused Dorn stuffing tubes in an enclosure, a neoprene plug can be inserted in place of the packing. are not required (nor supplied) when using the plug. Popular sizes are listed below: Plugs for Dorn Stuffing Tubes Plug NSN Size 5975-00- 1 296-3863 2 296-3862 4 & 4T 296-3861 Angled Stuffing Tubes. Wire connections that require a 90 degree angle to enter the enclosure can use the Dorn angled stuffing tubes. However, they are only available in the straight-through design and are not suitable for enclosures with NPT threaded holes. Dorn 90 Degree Stuffing Tube Sizes Cable Range Hole Size Size (jacket outside diameter) (diameter) NSN 5975-00- 1 0.077 0.296 0.885 503-4694 2 0.275 0.472 0.885 503-4693 4T 0.450 0.777 1.260 989-5045

Y Stuffing Tubes. Trying to stuff two wires into a box with only one stuffing tube? Instead of drilling another hole, use the Y stuffing tube. They are available from Dorn, but only in the straight-through design and are not suitable for enclosures with NPT threaded holes. Dorn Y Stuffing Tube Sizes Cable Range Hole Size Size (jacket outside diameter) (diameter) NSN 5975-00- 1 0.077 0.296 0.885 782-6139 2 0.275 0.472 1.010 782-6140 4T 0.450 0.777 1.260 782-6142 s for Straight-Through Stuffing Tubes. s for straight-through stuffing tubes ordered via MILSTRIP must be ordered separately. s for Straight-Through Stuffing Tubes Size NSN 5331-1 00-640-9161 2 00-580-5056 3 00-641-0231 4 & 4T 01-121-0192 Spanner Wrench. An adjustable spanner wrench for tightening the cap and lock nut without marring it is available from McMaster-Carr (http://www.mcmaster.com) for use with 1 through 4T stuffing tubes, part number 5471A11. Additional information is available on the Dorn website: www.dornequipment.com.