CEE 370 Fall 2015. Laboratory #3 Open Channel Flow

Similar documents
Experiment (13): Flow channel

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology

Chapter 13 OPEN-CHANNEL FLOW

...Eq(11.6) The energy loss in the jump is dependent on the two depths y 1 and y 2 3 = E =...Eq(11.7)

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

Civil Engineering Hydraulics Open Channel Flow. Adult: Where s your costume? What are you supposed to be?

OPEN-CHANNEL FLOW. Free surface. P atm

Open channel flow Basic principle

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

Chapter 10. Open- Channel Flow

EXAMPLES (OPEN-CHANNEL FLOW) AUTUMN 2015

Open Channel Flow 2F-2. A. Introduction. B. Definitions. Design Manual Chapter 2 - Stormwater 2F - Open Channel Flow

CHAPTER 9 CHANNELS APPENDIX A. Hydraulic Design Equations for Open Channel Flow

Experiment 3 Pipe Friction

FUNDAMENTALS OF FLUID MECHANICS Chapter 10 Flow in Open Channels

Lecture 24 Flumes & Channel Transitions. I. General Characteristics of Flumes. Flumes are often used:

Appendix 4-C. Open Channel Theory

M6a: Open Channel Flow (Manning s Equation, Partially Flowing Pipes, and Specific Energy)

CHAPTER 4 OPEN CHANNEL HYDRAULICS

Exercise (4): Open Channel Flow - Gradually Varied Flow

EVALUATION OF UNSTEADY OPEN CHANNEL FLOW CHARACTERISTICS OVER A CRUMP WEIR

Broad Crested Weirs. I. Introduction

FLOW CONDITIONER DESIGN FOR IMPROVING OPEN CHANNEL FLOW MEASUREMENT ACCURACY FROM A SONTEK ARGONAUT-SW

CITY UTILITIES DESIGN STANDARDS MANUAL

Backwater Rise and Drag Characteristics of Bridge Piers under Subcritical

Open Channel Flow Measurement Weirs and Flumes

Note: first and second stops will be reversed. Bring clothing and shoes suitable for walking on rough ground.

Chapter 9. Steady Flow in Open channels

2O-1 Channel Types and Structures

Lecture 22 Example Culvert Design Much of the following is based on the USBR technical publication Design of Small Canal Structures (1978)

21. Channel flow III ( )

Flow Over Weirs. By John Fuller. Fluid Mechanics Lab. Wednesday(1-345pm) Group member: Abdur Rahaman

Chapter 2. Derivation of the Equations of Open Channel Flow. 2.1 General Considerations

LECTURE 9: Open channel flow: Uniform flow, best hydraulic sections, energy principles, Froude number

Hydraulic Jumps and Non-uniform Open Channel Flow, Course #507. Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC

Design Charts for Open-Channel Flow HDS 3 August 1961

CIVE2400 Fluid Mechanics Section 2: Open Channel Hydraulics

Equipment for Engineering Education

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION DRAINAGE HANDBOOK OPEN CHANNEL. OFFICE OF DESIGN, DRAINAGE SECTION November 2009 TALLAHASSEE, FLORIDA

Basic Hydraulic Principles

1 Fundamentals of. open-channel flow 1.1 GEOMETRIC ELEMENTS OF OPEN CHANNELS

A Verification of Open Channel Flow Relations and Flow Straightening

Sharp-Crested Weirs for Open Channel Flow Measurement, Course #506. Presented by:

FLUID FLOW Introduction General Description

Natural Convection. Buoyancy force

CHAPTER 5 OPEN-CHANNEL FLOW

The Viscosity of Fluids

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Lecture 25 Design Example for a Channel Transition. I. Introduction

L r = L m /L p. L r = L p /L m

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Topic 8: Open Channel Flow

Chapter 8: Flow in Pipes

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

du u U 0 U dy y b 0 b

The University of Toledo Soil Mechanics Laboratory

Scattergraph Principles and Practice Practical Application of the Froude Number to Flow Monitor Data

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Floodplain Hydraulics! Hydrology and Floodplain Analysis Dr. Philip Bedient

Storm Drainage Systems

Emergency Spillways (Sediment basins)

Proceeding of International Seminar on Application of Science Matehmatics 2011 (ISASM2011) PWTC, KL, Nov, 1-3, 2011

The Viscosity of Fluids

MODELING FLUID FLOW IN OPEN CHANNEL WITH CIRCULAR CROSS SECTION DADDY PETER TSOMBE MASTER OF SCIENCE. (Applied Mathematics)

CHAPTER 3 STORM DRAINAGE SYSTEMS

Urban Hydraulics. 2.1 Basic Fluid Mechanics

Part 654 Stream Restoration Design National Engineering Handbook

Fluids and Solids: Fundamentals

CE415L Applied Fluid Mechanics Laboratory. Experiment: No. 5 Open Channel Flow Measurements and Grade Lines

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

Lecture 6. Jump as energy dissipation Control of jump.

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

1. Carry water under the canal 2. Carry water over the canal 3. Carry water into the canal

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Hydraulics Laboratory Experiment Report

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Chapter 5 MASS, BERNOULLI AND ENERGY EQUATIONS

Sediment Entry Investigation at the 30 Degree Water Intake Installed at a Trapezoidal Channel

Pressure drop in pipes...

OUTCOME 3 TUTORIAL 5 DIMENSIONAL ANALYSIS

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

Basic Principles in Microfluidics

Experiment # 3: Pipe Flow

Flow Measurement Calibration and Measurement

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

Fundamentals of Fluid Mechanics

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

CHAPTER 860 OPEN CHANNELS

For Water to Move a driving force is needed

SECTION 5 - STORM DRAINS

CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK PART - A

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Travel Time. Computation of travel time and time of concentration. Factors affecting time of concentration. Surface roughness

Hydraulics Prof. A. K. Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati. Module No. # 02 Uniform Flow Lecture No.

The ratio of inertial to viscous forces is commonly used to scale fluid flow, and is called the Reynolds number, given as:

Transcription:

CEE 70 Fall 015 Laboratory # Open Channel Flow Objective: The objective of this experiment is to measure the flow of fluid through open channels using a V-notch weir and a hydraulic jump. Introduction: Flow of water in a conduit is of two types: open-channel flow and pipe flow. These types of flows are similar but differ in one important aspect: open channel flow must have a free surface which is exposed to atmospheric pressure whereas pipe flow has no free surface since it if flowing full. Open channel flows are driven by gravity alone, and the pressure gradient at the atmospheric interface is negligible. Thus the basic force balance in an open channel is between gravity and friction. Reynold s number of open channel flow: Figure 1. A sketch of open channel flow As in pipe flow, three states of flow are possible, laminar, turbulent and transitional. The effects of viscosity relative to inertial forces of the flow determine the state of flow. The relative effects of velocity to inertia can be represented by the Reynold s number which is a dimensionless number derived through dimensional analysis of the flow. The Reynold s number for open channel flow is given by: RR = vr h ν Eq. 1 Where, Re is the Reynold s number; v is the mean flow velocity (in m/s); R h is a characteristic length (the characteristic length for open channel flow is the hydraulic radius) (in m), and ν is the kinematic viscosity of the fluid (m /s). Page 1 of 10

R h is calculated using the cross sectional area (A) divided by the wetted perimeter (P) where b is the width of the channel, and y is the depth of water in the channel (Eqs. and ). R h = A P Eq. P = b + y Eq. For a full pipe, hydraulic radius is calculated as (Eq. 4 and Fig. ): R h = 1 4 D h Eq. 4 V-notch weir in open channel flow: Figure. A graphic presentation of a wetted perimeter Weirs are overflow structures built across open flow channels to measure the discharge (or flowrate) (Fig. ). Some general terms pertaining to weirs are: Notch: the opening which water flows through Crest: the edge which water flows over Nappe: the overflowing sheet of water Length: the width of the weir notch Figure 1. A sketch of V-notch weir in open channel The basic principle is that discharge is directly related to the water depth above the bottom of the V; this distance is called head (h). The V-notch design causes small changes in discharge Page of 10

to have a large change in depth allowing more accurate head measurement than with a rectangular weir. To calculate the flow rate of an open channel flow, the Bernoulli equation (Eq. 4) for a 0 surface pressure is used (Eq. 5). Q is fluid discharge at any given point, which is the product of fluid velocity (V) and cross-sectional area (A). The cross-sectional area can be calculated as the product of the width of the free surface and the constant head (Eq. 5). Bernoulli s equation: P 1 ρρ + v g + z 1 = h 1 Eq. 4 Where P 1 v is the pressure head, is the velocity head, and z 1 is the velocity or potential head. ρρ g h 1 = V g Eq. 5 where h 1 is the head associated with velocity at a point in the weir; and g is gravitational constant. A = bh Eq. 6 where b is the width of free surface. b = (h h 1 ) tan α Eq. 7 where h is head associated with the total height of the weir; and α is the angle of the V-notch weir. The values of b and α are used to calculate the cross-sectional area. However, the flowrate changes when hydraulic head changes (Eqs. 8 and 9); dd = VV dh and dd = gh 1 [(h h 1 ) tan α ] dh 1 Eq. 8 h 1 b α h Page of 10

Figure 4. A sketch of discharge calculation The result of integration is represented by Eq. 8: Q = C D g tan α h 5 aaa C D = 8 15 Eq. 9 where C D is discharge coefficient. The theoretical value represented by Equation 9 precludes losses, upstream kinetic energy, and jet contraction. Neat, handwritten calculations are appropriate, with inclusion of a control volume sketch. State all assumptions. Hydraulic jump: In an open channel flow, a supercritical flow can change rapidly to a subcritical flow by passing through a hydraulic jump (Figure 5). The dimensionless number which indicates the relative effects of gravity and inertial forces on the state of flow is the Froude number. It is also derived through dimensional analysis and is defined as (Eq. 10): Fr = V gg Eq. 10 Where v is the average flow velocity, g is the gravitational constant, and y is the channel depth. Figure. A sketch of hydraulic jump in open channel flow The Froude number defines three regimes of flow in open channels: critical, subcritical, and supercritical flow (Table 1). Table 1. The three regimes in an open channel Fr Type of flow Criteria 1 Critical flow Y = y c ; V= V c <1 Sub-critical flow Y>y c, V<V c >1 Super-critical flow (fast flow-high energy state) Y<y c, V>V c The critical depth (y c in m) and critical velocity (V c in m/s) are calculated as follows (Eqs. 10-1): Page 4 of 10

FF c = V c gy c = 1 Eq. 10 Where Fr c is the critical Froude number. where V c = Q A c = A cg b Eq. 11 and A c = ( bq g )1 Eq. 1 and y c = ( Q b g )1 Eq. 1 Figure 6. A picture and schematic of a sluice gate for a hydraulic jump For this experiment, the discharge per unit width of a rectangular channel is calculated as (Eq. 14): q = Q b = VV Eq. 14 where q is the discharge per unit width of a rectangular channel. To get the sluice gate force, F eee is calculated as (Eq. 15): F eee = ρρq 1 y 1 y 1 + ρρ b (y y 1 ) Eq. 15 Page 5 of 10

Examples of Froude number is given in Table 1. Table 1. Description of Froude number Fr Jump Dissipation 1 Impossible 1-1.7 Standing wave (undular jump) about 4 y long <5 % 1.7-.5 Weak jump 5-15%.5-4.5 Unstable, oscillating 15-45% 4.5-9 Stable, well-balanced, steady jump 45-70% >9 Rough jump-intermittant and strong 70-85% For Today s Experiment: Apparatus: The apparatus consists of the following equipment, manufactured by G. Cussons, Limited, of Great Britain, and maintained in Marston 10: Hydraulic bench (P. 6100) Hook gauge and scale (P. 6107) Rectangular open channel (P. 645) 90 degree (α) V-notch weir Stop watch and scale Procedure: Part 1: V-Notch Weir 1. Note the water temperature in the hydraulic bench.. The cross sectional area of the drainage canal approaching the weir should be noted.. Measure the height of the bottom of the V to the bottom of the weir, as well as the cross sectional area that will be used to measure the volume of flow. (Referring to the low and high flow regions in the stepped measuring tank of the hydraulic bench). 4. Establish a low recirculating flow in the bench by turning the pump on and maintaining a low setting on the rheostat, with the measuring tank drain open. The discharge should be sufficient to create a free jet through the V-notch weir. Observe the progression of flow through the drainage canal, V-notch weir, and into the measuring tank and sump. 5. Record the water surface elevation in the drainage canal using the hook gauge 6. Be ready with a stopwatch. When measuring the flow rate, select a volume in the lower step of the tank (as well as the high step if chosen to do so). Turn the knob at the sump horizontal to stop drainage and allow for flow to accumulate to the selected volume. The timer should start at the time the drainage of the sump is stopped. There should be a total of replicates for this flow. Page 6 of 10

7. Increase the discharge for two more values. Make replicate measurements for each new flow, so that you'll have a total of replicated flows for different flows (giving a total of 9 data points) for the V-notch weir experiment. 8. Turn off the pump and open the measuring tank drain. Part : Hydraulic Jump 1. Measure the width of the open channel and the opening under the sluice gate.. Carefully turn on the pump and establish a subcritical depth y 1 upstream of the sluice gate (without flooding the lab), a supercritical jet of depth y downstream of the sluice gate, a hydraulic jump, and a downstream subcritical depth y.. Note the progression of flow from the inlet section of the flume, through the sluice gate, through the exit gate, and into the hydraulic bench measuring tank. Measure the discharge into the tank with a stopwatch and sight glass. Use a ruler to measure y 1, y, and y. 4. Measure the downstream locations of the sluice gate, start of the hydraulic jump and end of the hydraulic jump. 5. Turn off the pump and open the measuring tank drain when you're through. Data Analysis: Part 1: V-notch weir Estimate observed values for C D and the open channel Reynolds number (defined in class, based on upstream section) for the discharges of the V-notch weir. Part : Hydraulic Jump Compute the approach, jet, and exit Froude numbers Fr 1, Fr, and Fr for the jump. Compute the power dissipated across the hydraulic jump and the magnitude of the sluice gate force F EXT. Compute the discharge per unit width q. Results and Discussion: Why would you expect C D observed to be less than the theoretical Eq. (1b)? Does C D vary with Reynolds number? Verify the sub or supercriticality of the three open channel flow regions. Where are the controls located for y 1, y, and y? What fraction of the approach energy is dissipated across the jump? What is the ratio y to the sluice gate opening? Compare the observed y and y values with predicted values and comment. Basic contents of lab report: Introduction Materials and methods Results and discussion Conclusions References Appendix Page 7 of 10

Open Channel Flow Laboratory Part 1 Lab Group: Name: Date: V-Notch Weir Temp (C): Approach width, cm: Height of the bottom of the V to the bottom of the weir, cm: Area high Q section cm : Area low Q, cm : Low Flow Replicate ξ (cm) t (s) Q (cm /s) h 1 (cm) h (cm) C D Mid Flow Replicate ξ (cm) t (s) Q (cm /s) h 1 (cm) h (cm) C D High Flow Replicate ξ (cm) t (s) Q (cm /s) h 1 (cm) h (cm) C D Open Channel Flow Laboratory Part Lab Group: Name: Date: Hydraulic Jump and Sluice Gate Temp (C): Channel width, cm: Sluice gate opening, cm: Channel Depth, Y 1, cm: Distance from flow source, X 1, cm: Channel Depth, Y, cm: Distance from flow source, X, cm: Channel Depth, Y, cm: Distance from flow source, X, cm: Page 8 of 10

Jump start, X START, cm: Jump end X END, cm: X GATE, cm: ξ (cm): t (s): Q, cm /s: Example: Water flows in a wide channel at q = 10 m /(s-m) and y 1 = 8 m. If the flow undergoes a hydraulic jump, compute a) Y b) V c) Fr d) Y e) V f) Fr g) h f h) % dissipation of energy 1. Find the upstream velocity, V 1 q 10m m V 1 = = = 1.5m y1 8m. The upstream Froude number, Fr 1 is V1 1.5m Fr 1 = = = 0.14 (This is a subcritical flow) gy1 (9.8m )(8m). Is the hydraulic jump possible? a. Find the depth y y V 1 g + y 1 y + V 1 y 1 g = 0; y = 0.84 m b. Find the velocity after the gate V1 y1 1.5m 8m V = = = 11.9m y 0.84m c. The supercritical Froude number is Fr d. The depth, y, is V 11.9m (0.84m)(9.8m = = = gy ) Page 9 of 10 4.15

y y = 1+ [1 + 8 ] = y = 1/ 1/ Fr 1 [1 8(4.15) ] 0.84m y = 4. 5m e. The downstream velocity, V, is V y (11.9m )(0.84m) V = = =.m y 4.5m + + f. The downstream Froude number V.m Fr = = gy (9.8m )(4.5m) = 0. g. Dissipation head loss across the jump is ( y y) (4.5m 0.84m) h f = =. m 4y y 4(4.5m)(0.84m) = h. % Dissipation h % loss = f E (100) V (11.9m ) E = y + = 0.84m + = 8. 07m g (9.8m ) (.m) % loss = (100) = 41% 8.07m Page 10 of 10