ScottishPower Distribution Cables & Equipment. Metal Theft



Similar documents
Cables, Cable Laying & Accessories Manual

EDS KV TRIPLEX CABLE

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Network Standard Advice No. 1420C 9/6/2011

Fault location on power cables. Fault location on power cables

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

CONFLEX ELECTRIC CABLE

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

The Quality Connection. BETAflam Fire Resistant Safety Cables

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables /15 kv XLPE insulated cables /20 kv XLPE insulated cables 35

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Electrical Safety Products

Important Information: Complete Terms and Conditions are printed on sales invoices

Contents. All Rights Reserved

Gulf Cable & Electrical Ind. Co.

Specializing in the cable business for over 38 years, PT. SUPREME CABLE

Handling and Installation of Cables up to and including 33kV

Removal of EP SP High Voltage Cable

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

INTERNATIONAL STANDARD

Power and Wiring Cables

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

Catalogue Câbles d Energie

CLEVELAND CABLE LOCATIONS

FIRE RESISTANT CABLES FP200 GOLD

MEDIUM VOLTAGE CABLES Up to and including 36 KV

International Electrotechnical Commission Standards

Volume 1 NJUG GUIDELINES ON THE POSITIONING AND COLOUR CODING OF UNDERGROUND UTILITIES APPARATUS

Stephen G. Whitley, Senior Vice President & Chief Operating Officer

Utilities and existing services

UGVCL/SP/591/11KV HT AB CABLE

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

APPLICATION ORIENTED DESIGN OF CABLES

MEDIUM VOLTAGE POWER CABLES

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

KNOW YOUR OPTIONS: 230 KV POWER CABLES

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

How To Safely Dig For Natural Gas

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

environment briefing02

High Voltage Systems. Today. The history of cables

A. Shop Drawing submittals shall include, but not be limited to, the following:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

Flexible Control Cables

Flexible cables for submersible products

Section kv Power Cables

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

Chemical resistance Accidental

Earthing Guidance Notes

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

LOW VOLTAGE POWER CABLES

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

High Voltage Cable Systems

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

HINDUSTAN PETROLEUM CORPORATION LIMITED ENGINEERING & PROJECTS GRESHAM ASSURANCE HOUSE, 2 ND FLOOR, A-1595(3) 1-A, SIR P M ROAD, FORT MUMBAI

TABLE OF CONTENT

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

ECS INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

VIPERFLEX ELECTRIC CABLE

Session 14 Cable Support Systems

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

The evolution of medium voltage power cables up to 36 kv

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

Current Ratings. TABLE BEC 107. (Continued) Current ratings for 6350/11000 volts grade PILC/SWA/PVC cable to BS6480/69

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

CURRENT RATINGS MORE THAN A CABLE

For business. Wiring your business for broadband. What happens when copper is required?

Global cable expertise for rolling stock

Catalog May Cable Accessories < 1 kv

Fire Resistant Cables

Medium-voltage cables for reliable windpark infrastructure

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Undergrounding high voltage electricity transmission. The technical issues

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

XLPE Land Cable Systems User s Guide. Rev 5

Screened cable and data cable segregation

The original heating cable just got better

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR SINGLE CORE,UNARMOURED L.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA

Tri-Rated Flexible PVC Equipment Wire

Gulf Cable & Electrical Ind. Co.

Cables and Accessories Selection Guide

The Handbook 2013 EDITION

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

Document No Amendment No Approved By Approval Date Review Date NS112 DESIGN STANDARDS FOR INDUSTRIAL AND COMMERCIAL DEVELOPMENTS

Transcription:

ScottishPower Distribution Cables & Equipment Metal Theft April 2012

As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated underground equipment stolen from the ScottishPower network. Contents Page Abbreviations 3 Cable Identification 4,5,6 33,000 Volt Plastic Cables 7,8 33,000 Volt Paper Insulated Cables 9 11,000 Volt Three Core Plastic Cables 10 11,000 Volt Single Core Plastic Cables 11,12 11,000 Volt Three Core Paper Insulated Cables 13,14 Low Voltage Plastic Mains Cables 15,16,17 Low Voltage Paper Insulated Mains Cables 18 Low voltage Plastic Service Cables 19 Low voltage Paper Insulated Service Cables 20 Alternative Cable Designs (LSOH) 21 Earth Cable & Tape 22,23 Substation Equipment 24 ScottishPower Contact Details 25 Page 2 of 25

Abbreviations used in booklet Al Aluminium BS British Standard CNE Combined Neutral Earth CSA Cross Sectional Area (mm 2 ) Cu Copper H Hochstadter - screened 33kV paper cable HSL Hochstadter - screened separately lead sheathed 33kV paper cable kv kilo-volt LSOH Low Smoke Zero Halogen LV Low Voltage MDPE Medium Density PolyEthylene PICAS Paper Insulated Corrugated Aluminium Sheath PILCSTA Paper Insulated Lead Covered Steel Tape Armoured PILCSWA Paper Insulated Lead Covered Steel Wire Armoured PVC Polyvinyl Chloride SNE Separate Neutral Earth XLPE Cross Linked PolyEthylene N.B. All cable measurements given as an aide to identification are nominal sizes taken from British Standards or supplier specifications, actual cable sizes will vary slightly depending on the manufacturer and material quality. Page 3 of 25

Identification To assist in identifying cable types and equipment the booklet is laid out in sections covering: How to identify cable types from their external markings. Depth LV, 11kV & 33kV cables are buried in the ground. Types of identification / warning marker tapes placed over cables. Range of LV, 11kV & 33kV cables currently being installed on the network, and previous versions used. Earth wire & tapes Associated equipment Substation LV distribution board, transformer winding. External Markings All cables with a plastic covering (oversheath) will have the information below embossed or indented onto it for identification purposes. ScottishPower current list of approved manufacturers for the supply of power cables up to and including 33kV: Copper Cable Company Ericsson Nexans NKT Prysmian Cabelte Page 4 of 25

Cable Identification Depth of Cover Cables and ducts (pipes containing cables) shall be installed so as to provide the minimum depth of cover. Standard depths for each voltage category in the footway are highlighted below. Protective Tiles / Warning Tapes The following tapes and tiles are installed over cables and ducted installations, with the high visibility colours providing a warning of danger when excavating. LV Tape Thin polythene marker tape 0.1mm thick, 150mm wide 11kV Tape Marker tape laminated onto polyethylene 2.5mm thick, 200mm wide Page 5 of 25

Cable Identification 33kV Tile Thick tiles supplied with a plastic pin interlocking system 1000mm long x 244mm wide x 12mm thick Older Design Protective Tiles Before the use of plastic warning tape & tiles the brick versions below where used, for covering cables. LV - Small tiles (230 x 110 x 50mm) linked together with U-shaped metal pins. 11kV - Large tile (325 x 195 x 60mm) with inter-linking design built in. 33kV - (not shown) Large concrete tiles, approx 1 metre in length. Page 6 of 25

ScottishPower 33,000 Volt Cables Single Core Copper XLPE Cable The single core XLPE cable shown below in fig.1 was used as the standard circuit cable for 33kV up until March 2011. It is still available for repairs or deviations to existing Cu. cables, but has now been replaced by an aluminium version. The cables in figs. 2,3 & 4 are used on windfarm and connection from the grid applications. All single core 33 & 11kV cables should be laid in touching trefoil (triangular) formation and tied together. A. Copper conductor stranded round, range available shown in figs.1,2,3,4. Recently a 800mm 2 version of this cable has been installed on a windfarm job in Scotland. B. XLPE insulation thickness 8mm C. Copper wire earth screen - 50mm 2 CSA on all sizes of cable D. MDPE oversheath Page 7 of 25

ScottishPower 33,000 Volt Cables Single Core Aluminium XLPE Cable Aluminium single core XLPE cables are now used as the standard circuit cables for 33kV, as from March 2011. The introduction of these aluminium cables was due to the large rise in copper prices in recent years, even taking into account the larger conductor sizes required to carry the same power. 240mm 2 Al replacing 150mm 2 Cu 400mm 2 AL replacing 240mm 2 Cu A. Aluminium conductor stranded round, range 240 & 400mm 2 B. XLPE insulation thickness 8mm C. Copper wire earth screen - 50mm 2 CSA on all sizes of cable D. MDPE oversheath Page 8 of 25

ScottishPower 33,000 Volt Cables Paper Insulated Lead Covered 33kV Cables Fig. 1 Single core cable was generally used for switchgear connections within large substation sites. Fig. 2 - This cable was the main 33kV circuit cable installed on the network up to the mid 1990 s, prior to the introduction of XLPE cables. The standard conductor size used was 185mm. Fig.3 3 core HSL cable was installed in short sections for connections up poles to overhead lines. A. Copper or aluminium conductors 3 core range of conductor sizes on the network 70-300mm 2 with a diameter range between 80.9 107.2mm B. Layers of paper insulation impregnated with mineral oil compound thickness 6.8mm C. Conductive layer on each core - insulation screening D. Lead sheath with bitumen coating E. PVC oversheath F. Bitumen coated paper and hessian bedding layers G. Steel wire armours H. Bitumen coated hessian tape serving (oversheath) I. Separate lead sheath around each core, on 3 core HSL cable Page 9 of 25

ScottishPower 11,000 Volt Cables Three Core XLPE Cable ScottishPower began installing this type of cable in October 2003, as a replacement for PICAS, paper insulated cable. The three core XLPE cable shown below is currently used as the standard underground circuit cable on the 11kV network. It can also be found connected to terminations on overhead line poles. A. Aluminium conductors 3 x 95, 185, 300mm 2 solid round B. XLPE insulation thickness 3.4mm on each core C. Copper wire earth screen Fig.1-70mm 2 CSA on 95mm 2 cable Figs. 2 & 3-95mm 2 CSA on 185 & 300mm 2 cables D. Red MDPE oversheath Page 10 of 25

ScottishPower 11,000 Volt Cables Single Core XLPE Cable ScottishPower began installing this type of cable in October 2003. The single core XLPE cable shown below is only used within 25 metres of a substation, for connections to switchgear or pole terminations. A. Aluminium conductor 95, 185, 300mm 2 solid round B. XLPE insulation thickness 3.4mm C. Copper wire earth screen - 35mm 2 CSA on all 3 sizes of cable D. Red MDPE oversheath Page 11 of 25

ScottishPower 11,000 Volt Cables Single Core XLPE Cable The single core XLPE cables shown below figs.1 & 2 are used for connections between transformers and switchgear at primary substation sites. A. Copper conductor stranded round 300 & 500mm 2 B. XLPE insulation thickness 3.4mm C. Copper wire earth screen - 35mm 2 CSA on both sizes of cable D. Red MDPE oversheath Figs 3 & 4 show an older Paper Insulated Lead Covered (PILC) cable used for the same application. Page 12 of 25

ScottishPower 11,000 Volt Cables Paper Insulated Corrugated Aluminium Sheath (PICAS) PICAS cable was installed on the 11kV network up to October 2003, when it was replaced by 3 core XLPE as the standard circuit cable. A. Aluminium conductor 3 x stranded sector shaped, range available in figs1,2 & 3 B. Layers of paper insulation impregnated with mineral oil compound thickness 3.4mm between conductor and sheath C. Corrugated Aluminium sheath (bitumen coated) D. Red PVC oversheath Page 13 of 25

ScottishPower 11,000 Volt Cables Paper Insulated Lead Covered Steel Wire Armoured (PILCSWA) This was the main 11kV circuit cable installed on the network up to the early 1980 s, prior to the introduction of PICAS cable. A. Aluminium or Copper conductors 3 x stranded sector shaped on 70mm 2 cable and above, round conductors below 70mm 2. Large range of conductor sizes on the network 16-300mm 2 with an overall diameter range between 40.3-71.6mm B. Layers of paper insulation impregnated with mineral oil compound C. Figs. 1 & 2 Additional (belt) insulation layer D. Lead sheath, covered with bitumen coated paper and hessian layers, as a bedding for the armour wires E. Steel wire armours F. Bitumen coated hessian tape serving (oversheath) G. Fig 3. Shows a screened cable with a conductive layer applied over each core. Page 14 of 25

ScottishPower Low Voltage Cables 3 Core Waveform CNE Mains Cable This is the standard low voltage cable used to construct all new extensions to the network. The term waveform refers to the neutral/earth wires (D) in the cable which are laid in a wave formation (not wrapped around the cable) to assist stripping, when accessing the live conductors inside. A. Aluminium conductor 3 x solid sector shaped, range available shown in figs. 1,2,3 B. XLPE insulation thickness 95mm 2 cable = 1.1mm, 185 mm 2 cable = 1.6mm, 300 mm 2 cable = 1.8mm Live cores coloured: Brown, Black, Grey C. Rubber bedding layer D. Copper neutral / earth wires 70mm 2 CSA on 95mm 2 cable, fig.1 120mm 2 CSA on 185 & 300mm 2 cable, figs.2 & 3 E. PVC oversheath Page 15 of 25

ScottishPower Low Voltage Cables 4 Core Waveform SNE Mains Cable Use of this cable type on the network is limited to repairs and deviations on existing PILC LV cable. A. Aluminium conductor 4 x solid sector shaped, range available shown in figs. 1,2,3 B. XLPE insulation thickness 95 mm 2 cable = 1.1mm, 185 mm 2 cable = 1.6mm, 240mm 2 cable = 1.7mm Live cores coloured: Brown, Black, Grey. Neutral: core Blue C. Rubber bedding layer D. Copper earth wires 70mm 2 CSA on 95mm 2 cable, fig.1 120mm 2 CSA on 185 & 240mm 2 cables, figs.2 & 3 E. PVC oversheath Page 16 of 25

ScottishPower Low Voltage Cables Older Examples of Waveform CNE Mains Cable The picture below shows previous colours used to identify the conductors of low voltage cables, and the new colours which came into force in March 2006 as part of harmonisation across Europe. Fig. 2 shows waveform cable with aluminium neutral / earth (N/E) wires used before the copper version in fig.1 Fig. 3 shows one of the first designs of waveform cable introduced with black numbered cores, and aluminium N/E wires. Page 17 of 25

ScottishPower Low Voltage Cables Paper Insulated Lead Covered Steel Tape Armoured (PILCSTA) This type of LV cable was installed on the network up to the mid 1970 s, prior to the introduction of waveform cable. A. Copper or aluminium conductors 4 x stranded sector shaped Large range of conductor sizes on the network 70-300mm 2 with an overall diameter range between 38.4 66.9mm B. Layers of paper insulation impregnated with mineral oil compound thickness 1.2 to 1.6mm between the conductor and sheath C. Additional (belt) insulation layer D. Lead sheath, covered with bitumen coated paper and hessian layers, as a bedding for the armour wires E. Steel tape armours F. Bitumen coated hessian tape serving (oversheath) Page 18 of 25

ScottishPower Low Voltage Cables Plastic Service Cables The service cables below are used on the network to supply street lighting columns - fig.3, houses - figs. 1 & 4, small blocks of flats, small factory / commercial units - figs. 2,5,6. Figs. 1 & 2 show combined neutral earth (CNE) cables used on new build installations, to latest wiring regulations. Figs.3,4,5,6 show separate neutral earth (SNE) cables used on older installations. A. Aluminium conductor sizes available 25 & 35 mm 2 Fig 6. Shows a copper cable available, but not commonly used B. XLPE insulation C. Copper wire neutral / earth D. PVC oversheath E. Covered neutral conductor F. Copper earth wire Page 19 of 25

ScottishPower Low Voltage Cables Paper Insulated Lead Covered Service Cables The service cables below where used on the network prior to the introduction of plastic cables. A. Copper conductors 2 or 4 core versions Range of conductor sizes on the network 4-35mm 2 2 core overall diameter range between 19 24.6mm 4 core overall diameter range between 22 31.9mm B. Layers of paper insulation impregnated with mineral oil compound thickness 1.0 to 1.2mm between the conductor and sheath C. Additional (belt) insulation layer D. Lead sheath, covered with bitumen coated paper and hessian layers, as a bedding for the armour wires E. Steel tape armours F. Bitumen coated hessian tape serving (oversheath) Page 20 of 25

ScottishPower Cables Low Smoke Zero Halogen Cables (LSOH) For all the plastic low voltage service, mains and 11kV cables shown on the previous pages ScottishPower also buy versions with a LSOH oversheath, coloured orange. These are used where significant cable runs inside buildings are required, and have the advantage of not giving off toxic fumes in the event of a fire. Examples of LSOH service and mains cables below, identical to standard cable construction apart from the oversheath material: Page 21 of 25

ScottishPower Earth Cables & Tape Earth Cable The earth cables below can be found in sub-stations, up poles and fig.1 in customers houses. A. Copper conductor stranded round Also available (but not shown) are 10mm 2 & 6mm 2 cables B. PVC Oversheath green / yellow Earth Tape The copper & aluminium earth tapes are used to connect all the metalwork / switchgear within substation buildings and outdoor compounds. Page 22 of 25

ScottishPower Earth Cables & Tape In addition to the sizes on previous page 1.1/2" X 3/16" copper tape was used, with 25mm x 3mm & 40mm x 4mm copper now available as standard from stores. Examples of earth cable & tape installations within a substation Fig.1 Fig.2 Fig.3 Fig.1 3 x Copper earth cables connected to main aluminium substation earth tape. Fig.2 Copper earth tape connected to main aluminium earth tape. Fig.3 Aluminium to aluminium tape connection. N.B. Copper earth tape and cable has been a major target for theft in a number of areas. To help combat this there have been a number of increased security measures introduced into the company: Use of `identifiable` aluminium earth tape in place of copper where possible At selected sites the use of a high security steel pin fixing system for copper earth tape Superior high security steel padlocks and `lock-keeper` devices for installation at vulnerable sites. Page 23 of 25

Examples of Substation Equipment Fig.1 shows a transformer removed from a substation building in an attempt to dismantle it, for the copper inside. There are not only huge risks electrically from this type of activity but because this equipment is oil filled a spill could also have a big environmental impact. Fig.2 shows the copper winding from inside a transformer. Figs.3 & 4 show an un-insulated LV board with exposed copper busbars and 4 x LV mains cables attached. Fig.1 Fig.2 Fig.3 Fig.4 Page 24 of 25

ScottishPower Contact Details WHAT TO DO IF YOU FIND CABLES OR FOR QUERIES ABOUT EMPLOYEES OR CONTRACTORS (24/7) If you find cables or earth tape which you believe may belong to ScottishPower (SP) or wish to ask about employees or contractors please contact the ScottishPower Grid Control room at Kirkintilloch. The Grid Control Room will not always know whether someone is employed as a contractor but it is the best place to start. Tel: 0141 776 4185 Email: SWITCH1@ScottishPower.com. TO CONTACT SP ALARM RECEIVING CENTRE (ARC) (24/7) If, for any reason, you cannot get hold of Grid Control the Cathcart ARC is also manned 24/7. From Autumn 2012 ARC security staff will have access to records of all staff and contractors with photo passes. Tel: 0141 568 2024/2025 OTHER USEFUL CONTACTS (NOT 24/7) Charlie Hendrie (Security Manager Scotland and Ireland) Tel: 0141 568 4725 Email: Charles.Hendrie@scottishpower.com Harry Lees (Energy Networks) Tel: 0141 614 1473 Email: Harry.Lees@scottishpower.com PERSONAL PROTECTIVE EQUIPMENT (PPE) Many genuine SP employees still use PPE with old SP logos on. Equally the ownership of PPE with current or former SP logos on does not prove the person works for SP. By the end of 2012 all current SP staff should have a green photo pass with their name on it to prove their identity. Long-term contractors will also have an orange photo pass but contractors working off-site or in new sites where there is no access control system fitted will not necessarily have such passes. Page 25 of 25