Alarm and Detection/Suppression



Similar documents
University of Houston Master Construction Specifications Insert Project Name

SPECIFICATION FOR A TOTAL FLOOD HFC-227ea CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE Cheetah Xi CONTROL PANEL SYSTEM

Module 5. Fire and Emergency Alarm System Part I- Basics

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

ENGINEERING SPECIFICATIONS

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

E2-E3: ELECTRICAL CHAPTER-13 FIRE PROTECTION SYSTEM- EVOLVING TRENDS AND APPLICABILITY TO DATA CENTRE

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

EXHIBIT A SCOPE OF WORK

Conventional Fire Detection and Extinguishant Control System Specification

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Standard Message Library

Using your LED Plus keypad

CBD-233. Fire Alarm and Detection Systems

DCSS (DCL) Data Center Fire Suppression Procedures

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

melbourne//australia data center specifications internet + intellectual property + intelligence tel: fax:

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

The Mission Critical Fire Protection Experts

Manual for Fire Suppression & Methane Detection System

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

616, 626, 636 & 646 Keypads

PLAN REVIEW GUIDE FOR FIRE ALARM

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

3M Novec 1230 Fire Protection Fluid For Telecommunications and Data Center Applications. Stay

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

How intelligent must an extinguishing solution be to keep fire virtual?

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling

CO 2. fire extinguishing systems

Fire Protection Options for Data Centres

For Data Center and Control Room Applications

DATA CENTER FIRE PROTECTION

FIRE ALARM SYSTEM RECORD OF COMPLETION

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE SUPPRESSION & DETECTION SYSTEMS

FIRE DETECTION/INERGEN SUPPRESSION SYSTEM ENGINEERING SPECIFICATIONS

FIRE DETECTION AND FM-200 SUPPRESSION SYSTEM

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Release Control Fire Alarm Systems

DCSS (ACB) Data Center Fire Suppression Procedures

SECURIT 800L+ CONTROL PANEL

Certificate of Conformity Certificate num. Registration date Version Valid until

SECURITY SYSTEM NOTES

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

P/N Rev D

SECURITY SYSTEM NOTES

NetworX NX-6V2. LED Keypad User Manual

Ammonia Detection System Codes and Design Specifications

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

User Guide for the DS7060 Control/Communicator

Maximum uptime and optimum fire safety for your data center

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

DETERMINE THE HAZARD VOLUME. The first step is to calculate the total volume of the hazard being protected.

SECTION FIRE ALARM AND DETECTION SYSTEM

Maximum uptime and optimum fire safety for your data center

For Data Center and Control Room Applications

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

SECTION FIRE ALARM AND DETECTION SYSTEM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

User s Guide. Security Systems D220

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

conventional system operation

ICC CODE CORNER 2012 IFC Code & Commentary

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Control/Communicator Installation Manual

Contact ID Event Definition Codes

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

User s Information Guide R1A

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

FIRE PROTECTION. FOR COMPUTER ROOMS By Mark L. Robin CLEAN AGENT. FS-World.com. 8 ire & Safety Magazine

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

rpsa FIRE PROTECTION ENGINEERS

Contact ID as of 2/2/2015

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

EKOS Cart. Instructions for Use

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

Control panel software versions 2.00 and beyond.

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

SECURITY SYSTEM NOTES. Security System Configuration

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

SECTION DETECTION AND ALARM

ACTIVE 5 ENGINEERING MANUAL

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Fire detection equipment

Enhanced. Commercial Burglary Partitioned Security System with Scheduling. User Guide. K4970-1V3 4/09 Rev. B FA560 3 STAY 2 AWAY 1 OFF 5 TEST 9 CHIME

Transcription:

Alarm and Detection/Suppression

Fire Safety

American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services

Clean Agent What are our goals today? How does a Clean Agent extinguish a fire Types of Clean Agents systems Halon? Design Considerations of a Clean Agent System System Components Sequence of Operation

How Does a Clean Agent System Work? Most clean agent s work by chemically extinguishing a fire at the molecular level. In order to extinguish a fire, the agent decomposes. When a Clean Agent decomposes, toxic gases are released. (Does not apply to inert gasses: CO2, Inergen) To avoid high levels of decomposed gasses, systems are designed for quick discharges (UL requires <10 seconds).

How Does a Clean Agent System Work? (cont) Agent Storage Agent is a liquid, stored in cylinders, pressurized with N2. Agent is super pressurized with N2 to a pressure of 360 psi. Agent is distributed to discharge nozzles, drilled to allow a specific flow rate. Discharge nozzles are located in the room area and below under floors. Cylinders are furnished with low-pressure switches to monitor agent pressure.

How Does a Clean Agent System Work? (cont) Halon HFC s Inert Gas Oxygen Depletion Primary Heat Absorption Secondary Primary Reaction Interruption Primary Secondary Chemical Reaction Heat Oxygen Fuel

How Does a Clean Agent System Work? (cont) Physical Heat absorption - remove heat faster than generated Reduces flame temperature below that necessary to maintain combustion Chemical Interruption of chemical chain reactions of combustion process by halogenated atoms (Fl, Cl, Br)

Physical Properties Property Halon 1301 FE-25 HFC-227ea Novec Inergin Chemical Formula CF3Br CHF2CF3 CF3CHFCF3 Molecular Weight 148.9 120.02 170.0 316.4 34 Boiling Point -72º F -55º F 3º F 120º F Vapor Pressure 200 psi 195 psi 66 psi 5.87 psi 2175 ODP 12 0 0 0 0 GWP 6900 2800 2900 1 0 Zero Ozone Depletion Potential (ODP) Very low Global Warming Potential (GWP) GWP is calculated of a 100 year time horizon and represents mass of CO2 equivalent to emission of one unit of this compound

Different Types of Fire Suppression Systems FM-200 (HFC-227ea) CF3CHFCF3 Most common agent used. Works by chemically inhibiting fire propagation. Poor flow characteristics. Supports 12 nozzles max

Different Types of Fire Suppression Systems (cont) Novec 1230 (Sapphire) CF3CF2C(o)CF(CF3)2 Fairly new agent. Works the same as FM-200. Short after life in the atmosphere (days). Poor flow characteristics. Pressurized with Nitrogen

Different Types of Fire Suppression Systems (cont) Ecaro 25 (Dupont FE-25) CHF2CF3 Closest to replacing Halon 1301 Works by removing O2 at the molecular level. Superior flow characteristics. Required 25% less agent than FM-200. Most economical of Clean Agents. No pressurization concerns No venting required Support 30 to 40 Nozzles

Different Types of Fire Suppression Systems (cont) Inergen (Argonite. Same as Inergen without any CO2) Inert gas (52% nitrogen, 40% argon, and 8% carbon dioxide) Lowers the oxygen in the room to a level that won t support a fire, but still enough oxygen to breath. Design is critical. Must vent room due to pressure build up. Doesn t leak from the room because of low density. Economical to recharge (Hard to find recharge locations).

Different Types of Fire Suppression Systems (cont) Water Mist (Micro Mist) Non-Chemical. Micron size water droplets. Best used for generator rooms or areas with high leakage. Very economical to recharge.

Different Types of Fire Suppression Systems (cont) CO2 (Carbon Dioxide) Not classified as a Clean Agent. Can be lethal to humans. Operates by removing the oxygen from the air. Good for non-occupied hazards.

United States Position - Halon Montreal Protocol - ban on Halon production - 12/31/93 No current restrictions on use of reclaimed or recycled Halon No current restrictions on existing installed systems Halon market value decreasing

Halon Retrofit Objectives Maintain an equivalent level of protection Utilize the existing Halon 1301 piping network Minimize business interruption Environmentally preferred Realize the most cost effective solutio Is Green important?

Halon Replacement No reason to remove Halon, but difficult to recharge if dumps FM200/Ecaro/Inert Gases/Green Gases Ecaro best one for one replacement.

Define Hazard System Design Determine volume of area(s) (L X W X H). Areas may include room, under-floor, and above ceiling.

Agent/Quantity Determine which agent to use. Try to use the same agent/mfg that is currently used in the facility. Determine quantity of agent to use.

Design Concentrations Comparison ECARO-25 8.0% 685 lb. 1 Halon 1301 6.0% 623 lb. 1 HFC-227ea 6.25% 765 lb. 1 Inergen 37% 357 m 3 21 Novec 4% 948 lb. 2

Systems Design Automatic and Manual Operation Smoke Detectors are used for automatic operation Manual release stations are used for manual operation. System Alarms Alarm bells Horn strobes Strobes

Releasing Panels System controls Systems Design Main Control Panel ( UL9th Must be listed to release specific) Operates on 24 volts DC from a 120-volt AC input power source. Contains batteries for DC back up. Monitors and controls all input and output circuits. Includes replays for connections to building alarm panels and remote monitoring

Discharge Nozzles Systems Design Determine quantity and location for nozzles. Limit nozzles to a maximum flow of 20lbs./second. Locate nozzles in each protected area (Room/U/Floor). Try to locate nozzles away from exit doors.

Main Control Panel System Components Is Conventional or Intelligent. Used to monitor and control input and output devices. Supplies power to the field devices. Supervises field wiring INPUTS Opens, Grounds OUTPUTS Opens, Grounds, shorts Displays alarms and troubles. Contains timers for time delays for agent release.

System Components (cont) Ionization Smoke Detector Detects 1-2 micron particle size. Should be used in room areas only (airflow issues)

System Components (cont) Photoelectric Smoke Detector Detects visible particles (4+ microns) (Visible) Good for under floor areas. Normally not as sensitive as an ionization detector.

System Components (cont) Heat (Thermal Detector) Operates when temperature reaches set point. Not good for early warning detection Best suited for harsh areas (Smokey/Dirty).

System Components (cont) Air Sampling System Detects Sub-micron size particles. Good for ultra early warning of a fire condition. Detects Thermal degradation of the item. Allows you to be Pro-Active to alarms. You can find the source of the problem before needing the suppression system. Fairly expensive, but could save the cost of a systems recharge.

System Components (cont) Manual Release Station Used to manually discharge the system. Instant release, bypassing any time delays. Normally located near exit doors. Code requires every system to have a manual release.

System Components (cont) Abort Station Used to bypass a pending discharge. Located next to the manual release station. Must be depressed (operated) in order to bypass a discharge. Must be operated prior to a system release.

System Components (cont) Alarm Devices Alarm Bells. Used for 1 st detection zone alarms. Used for Air sampling system alarms.

System Components (cont) Horn Strobes Can be used for 1 st / 2 nd / Discharge alarms Normally are pulsed to indicate type of alarm. Slow pulse 1 st zone alarm Fast pulse 2 nd zone alarm (pre-discharge Steady Discharge alarm.

System Components (cont) Strobe Lights Normally used to indicate a system discharge. Located outside exit doors. Attached to a horn inside the hazard area, a strobe indicates a general alarm condition.

System Components (cont) Agent Storage Cylinders Used to store Clean Agent. Is supplied with pressure gauges and lowpressure switches. Are supplied with valves or bursting disc. Solenoids used to actuate valves. Actuators used for bursting disc type.

System Components (cont) Discharge nozzles. Used for distribution of agent. Located in protected areas. Sidewall and center room type. Maximum flow rate of 200 lbs (20 lbs. second)

Actuators System Components (cont) GCA (Compressed Gas Actuator). Triggered by small charge. Requires special handling. Used on cylinders with rupture disc. Solenoid Activated by applying voltage to coil. Used on cylinders with valves. Can also be used on N2 (Nitrogen Actuators)

System Components (cont) Special Detection Systems Early Warning Fire Alarms (VESDA/SAFE) Used for very early warning of a fire. Monitors particle size of.01 micron (Invisible) Works by taking air samples in the room and counting the particulate. Allow personnel to be pro-active in finding a potential fire hazard and eliminating the need to use the suppression system.

EARLY WARNING SMOKE DETECTOR Particles of Combustion are Found in Air Samples Control Panel Indicates Pre/Alarm Condition Control Bar Graph Indicates Level of Particle Count Control Panel Alarm Level Contacts Operate Alarm Bells in Ground Floor Area Are Activated

Detection Devices Determine quantity of smoke detectors. Use a spacing of 250 sq. ft. per detector. In room areas use a combination of ionization and photoelectric smoke detectors. In under-floor spaces, only use photoelectric smoke detectors. Located a manual release and abort station at the primary room exits. Normally, these are installed inside the hazard area. Locate audible and visual devices in the room so all personnel can hear/see the alarms. Locate discharge strobes outside of the main exit doors.

Sequence of Operation Single Smoke Detector In Alarm Control Panel Indicates Alarm Condition Control Panel Alarm Contacts Operate Control Panel Displays Device and Location of Alarm L.E.D. On Smoke Detector Illuminates Steady On Alarm Horn in Hazard Area Starts a Slow Pulse Signal Alarm Strobe in Hazard Area is Activated

Sequence of Operation (cont) Two Smoke Detectors in Alarm (Same Hazard Area) Control Panel Displays Device and Location of Alarm L.E.D. on Smoke Detector Illuminates Steady On Alarm Horn in Hazard Area Changes to a Fast Pulse Signal Control Panel Pre-Discharge Delay Timer is Activated Equipment Shutdown Contacts Are Activated

Note: Sequence of Operation (cont) At the end of 30 seconds, the system is discharged into the hazard area. If the abort station is operated prior to the 30- time delay, the system will not discharge. The abort is a Dead Man type, and must be continually depressed in order to bypass a discharge. Releasing the abort station will cause the time delay to restart.

Sequence of Operation (cont) System Discharge Control Panel Displays System Has Released Discharge Strobe Outside Exit Door is Activated Alarm Horn in Hazard Area Changes to a Steady Tone Discharge Strobe Outside of Exit Door is Activated Shutdown Relays are Energized

Sequence of Operation (cont) System Alarms and Troubles Control Panel will Display Either Alarm or Trouble Control Panel will Display Cause of the Alarm or Trouble Control Panel Sonalert Will Sound

Note: Sequence of Operation (cont) Depressing Acknowledge button on front panel can silence the control panel sounder. Alarm devices in the field can be silenced by depressing the Alarm Silence button on front panel. Depressing Reset button will return panel to Normal condition.

Sequence of Operation (cont) FIRE ALARM Operation of Any Smoke Detector or Fire Alarm Pull Station Control Panel Indicates Alarm Condition Control Panel Alarm Contacts Operate Control Panel Displays Device and Location of Alarm L.E.D. on Smoke Detector Illuminates Steady On Alarm Horns in Hazard Area Starts a Pulse Signal Shutdown Contacts Operate

Sequence of Operation (cont) NOTE: Depressing Alarm Silence button on control panel door will silence alarm bells. Depressing Reset button will reset panel to normal condition.

Clean Agent The End Thanks For Taking The Time To See This!! We Hope This Will Help

Questions? Leave me your card/email or email me if you would like additional information on any of the additional detail paulh@americanfiretech.com