Condition Based Monitoring of Gas Turbine Combustion Components Program Review



Similar documents
BB-18 Black Body High Vacuum System Technical Description

Tube Control Measurement, Sorting Modular System for Glass Tube

How To Use A Ds340 (Dsp)

The Do s and Don ts of Pressure Transducers

INFRARED PARTS MANUAL

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Fiber Optic Distributed Temperature Sensor (B-DTS)

The Design of a Low-Cost and Robust Linkage Position Sensor

Current Probes. User Manual

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Continuous Thermal Monitoring to Minimise Slag Carry-Over in Steel Production. Slag Detection System

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Practical Application of Industrial Fiber Optic Sensing Systems

Fundamentals of Mass Flow Control

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Project 2B Building a Solar Cell (2): Solar Cell Performance

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

E190Q Lecture 5 Autonomous Robot Navigation

Computerized Micro Jet Engine Test Facility

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Combustion Dynamics Instrumentation

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

Polymer Coated Fiber Cable (PCF)

Amplified High Speed Fiber Photodetectors

Optical Power Meter. Specification & User Manual

Owner s Manual

Experiment 5. Strain Gage Measurements

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

1 WATERFLUX - Comparisonon COO Rectangular Magmeter in water applications

The Unique Accelabar Flow Meter


PRODUCT SPECIFICATION

Low Load Operational Flexibility for Siemens G-class Gas Turbines

PRODUCT SHEET OUT1 SPECIFICATIONS

Unmatched Metal Hardness Testing

Impedance 50 (75 connectors via adapters)

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

Certificate: _01 / 29 April 2014

HYDROMATRIX Jebel Aulia - Sudan

Certificate: / 20 August 2013

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Series 6000 Torque measured metal bellow coupling

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

OPERATION MANUAL INFRARED THERMOMETER

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

Real-Time Temperature Monitoring of 13.7 kv Breaker Outputs Using Fiber Optic

Advances in Thermal Dispersion Mass Flow Meter Accuracy

75 Ω Transmission System

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Department of Aerospace Engineering Indian Institute of Science Bangalore

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

9000 Series Accelerometers Specifications

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Physical Specifications (Custom design available.)

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

MEASUREMENT SET-UP FOR TRAPS

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

ST Series POWER SUPPLIES USER INSTRUCTIONS

A Simple Fiber Optic displacement Sensor for Measurement of Light Intensity with the Displacement

Highly efficient flue gas analyzer

We bring quality to light. ISP Series Integrating Spheres

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

SGT5-8000H SCC5-8000H 1S. Experience of Commercial Operation at Irsching 4. ANIMP-ATI, Sesto San Giovanni 26 June 2012

THERMAL RADIATION (THERM)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Model 1210C Battery Powered Pump Shown. Description

Low Frequency Velocity Sensor

Cosasco Wireless System

Table of Contents. TransformerIQ FAQs 1

Calibration of Dallas sensors

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Various Technics of Liquids and Solids Level Measurements. (Part 3)

EVALUATING SOLAR ENERGY PLANTS TO SUPPORT INVESTMENT DECISIONS

1701/22 FieldMonitor Management Interface Module

Intelligent Mould Flow Monitoring

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Multifunction HVAC and IAQ Meter

Product Overview 9100D

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

User checks and maintenance of laboratory balances

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Pin & Vee Block Test Machine

Wahl C50 Calibrator FEATURES

Transcription:

Condition Based Monitoring of Gas Turbine Combustion Components Program Review DoE Funding Opportunity No. DE-PS26-08NT00440-1B DoE Award Cooperative Agreement No. DE-NT0006833 March 2012 Nancy Ulerich Ph.D. Getnet Kidane Nikolai Tevs Ph.D.

Gas Turbine Combustion Section Online Condition Monitoring Needs Hot section combustion components of gas turbine engine are exposed to harsh operating conditions and high temperatures. As a result, combustion parts have shorter design lives and more frequent maintenance inspection interval requirements than other parts of the turbine engine. Frequent maintenance inspection outages affect engine availability and reliability. Use of sensor technology that directly detect and monitor hardware life online can help to optimize maintenance outage intervals. At present, there are no proven high temperature sensors available to continuously monitor the two primary lifelimiting issues of combustion parts: cracking and wearing. Compressor Combustor Turbine Siemens SGT6-5000F Turbine 03-14-2012 2

Project Overview Project Goal: The project goal is to develop wear and crack monitoring technologies to enable real-time condition monitoring and assessment of critical hot section combustion parts. The project develops hot component sensors and an integrated system to use the sensors to enhance plant and component reliability with a robust condition monitoring network. Project Objectives: 1) Develop a Magnetic Crack Sensor: Design, develop, and demonstrate a high temperature multifunction magnetic sensor to monitor cracking and temperature in hot section combustion components 2) Develop a Fiber Optic Wear Sensor: Design, develop, and demonstrate a high temperature sensor to monitor wear of hot section combustion components Compressor Combustor Turbine Siemens SGT6-5000F Turbine 03-14-2012 3

Program Tasks Task 7 Program Management Task 1 Monitoring System Configuration and Specifications Task 2 (K Sciences) Develop High Temperature Wear Monitoring Sensor Task 3 (JENTEK Sensors) Develop Multi-Functional Online Monitoring Sensor for Crack, Crack Growth, and Temperature Task 4 Develop Parts Condition Assessment Model for Remaining Life Determination and Maintenance Interval Optimization Task 5 Implement Integrated Combustion Components Online Monitoring System Task 6 Engine Demonstration Test 03-14-2012 4

Participants and Roles Participants Role of Participants Added Vendor Program Management Combustion Monitoring System Specification Design Integrated Combustion Condition Based Monitoring System Prototype Sensor System Tests in Simulated Engine Environment System Validation Testing in Demonstration Engine Laboratory Proof of Concept Tests Sensor Redesigns Added Scope Philtec Inc. K Sciences GP, LLC Design High Temperature Wear Sensor Fabricate Wear Sensor and Electronics Laboratory Proof of Concept Tests and Prototype Tests JENTEK Sensors, Inc. Design Multifunction Magnetic Crack and Temperature Sensor Fabricate Multifunction Sensor and Electronics Laboratory Proof of Concept Tests and Prototype Tests 03-14-2012 5

Development Status: Key Milestones and Deliverables Sensors passed two formal R2 conceptual design reviews. Wear sensor passed a final R5 engine design review Wear sensor approved for engine installation in March to April Outage Technical Progress Milestone Go / No-Go Milestone M1 1.4 Task Description Status Develop Online Combustion Monitoring System Specification for the Wear and Crack Sensors Completed M2 2.2 Concept Design of Wear Sensor Completed M3 2.5 Lab Proof of Concept Wear Sensor Test Completed Milestones Status M4 3.2 Concept Design of Crack and Crack Growth Monitoring Sensor Completed M5 3.3 Concept Design of Temperature Monitoring Sensor Completed Integrate Crack and Temperature Monitoring Capabilities within a Single M6 3.4 Sensor Completed M7 3.7 Lab Proof of Concept Crack Detection Test Completed M8 4.4 Develop Crack and Wear Monitoring Algorithms for Online Monitoring Completed M9 5.4 Wear and Crack Condition Monitoring Software Prototype Completed M10 6.1 Identify Engine Unit for the Prototype System Demonstration Test Completed M11 6.3 Design Review of Integrated System Specification Completed Installation March-April M12 6.6 Perform Demonstration Test 2012 M13 6.6 Final Report - Test Results Sep-2012 03-14-2012 6

Develop Specifications for Sensors Fuel Nozzles/Basket Swirler Bore Assembly Interface Fuel Nozzle Stem and Basket Swirler Bore contact surfaces Basket/Transition Assembly Interface Basket Spring Clip and Transition Inlet Ring contact surfaces Transition/Stage-1 Vane Assembly Interface Transition Floating Exit Rails Seal and and Floating Vane Seal Assembly contact Interface interface Transition Floating Seal and Stage-1 Vane assembly interface Identify Critical Combustion Parts for Monitoring - Identify locations - Define monitoring needs Driving factors and operating conditions contributing to wearing and cracking Develop online combustion monitoring system specification for the wear and crack monitoring (Milestone 1) 03-14-2012 7

Wear Sensor Development Specification Requirements Sensor Maximum Operating Temperature Fiber Optic Transmission Cable Operating Temperature Wear Measurement Resolution Wear Measurement Range Sensor System Operating Life Target 1000 o C (1832 o F) 500 o C (932 o F) +/-0.025 mm (0.001 inch) 0 to 10 mm Minimum of 2000 hrs for prototype sensor demonstration test Note * Very high target for a new sensor development. * Transmission cable used from the sensor location to outside of engine casing. * Very high resolution target, information valuable if resolution is 0.25mm * Prototype sensor target * Ultimate goal is to have a sensor with design life equal to combustion parts inspection interval cycle measured in thousands of hours. 03-14-2012 8

Magnetic Sensor Development Specification Requirements Sensor Maximum Operating Temperature Transmission Cable Operating Temperature Crack Detection Resolution Crack Growth Monitoring Range (max crack length) Temperature Measurement Accuracy Sensor System Operating Life Target 1000 o C (1832 o F) 500 o C (932 o F) Minimum of 0.50mm crack length by 0.25mm crack depth 0 to 30 mm +/-15 o C (27 o F) Minimum of 2000 hrs for prototype sensor demonstration test Note * Very high target for a new sensor development. * Transmission cable used from the sensor location to outside of engine casing. * Prototype sensor target * Secondary objective to use the sensor for dual use (temperature and crack monitoring). * Ultimate goal is to have a sensor with design life equal to combustion parts inspection interval cycle measured in thousands of hours. 03-14-2012 9

Sensor Development Progress Wear Sensor K Sciences Baseline Design Inadequate measurement stability in wearing environment R2 Concept Design Concept Design and Tests Alternative Design with Philtec Probe Crack Sensor R2 Concept Design Concept Design and Tests Concept Design and Tests R3 Design R5 Engine Design Failed to develop an integrated system with measurement capability for prototyping Installation SGT6-5000F Frame JENTEK Sensors Inc. Proposed development needs too large to continue 03-14-2012 10

Validation Tests: Key Success Factors Obtained from Various Testing Levels Key Success Factor Vender Test Siemens Lab Tests Engine Test Measurement resolution and accurcy NA Measurement in actual materials and reflection environment of an engine NA NA Measurement repeatability Wears with contacting part Temperature cabability, short term Temperatuer capability, long term NA NA Engine robustness NA NA Installation capability NA NA Engine impact acceptable NA NA NA NA R2 Concept Design R3 Design R5 Final Design Details Siemens developed specialized laboratory tests to go beyond vendor capabilities 03-14-2012 11

Develop High Temperature Wear Monitoring Sensor (Baseline Sensor) Fiber optic sensor technology, initially developed by K-Sciences, monitored wear by determining sensor length directly as the sensor tip erodes with the wearing layer. Sensor development target: operating temperature of up to 1000C, and wear rate measurement resolution of +/-0.025mm (0.001inch). To Signal Processing Electronics Wearing Layers Fiber Optic Cable Sensor Element Raw Output, mv Average Intensity, mv 70 65 60 55 50 45 40 Schematic of wear sensor instrumentation 35 2.50 3.00 3.50 4.00 4.50 5.00 5.50 Fiber Length, Inch Sensing Element Length, mm Raw output correlation to sensing element length Application Example 03-14-2012 12

Concept Design of Fiber Optic Wear Sensor (Baseline Design) The fiber optic wear sensor works using optical light transmission principle governed by Beer-Lambert Law. The optical light transmission intensity through a fiber can be related to the fiber length as shown below. Light in Optical fiber with attenuation coefficient, α, and length, L I 0 I 1 Light out I 1 = I 0 e α L Beer Lambert Transmissivity of Light as It Travels through an Optical Fiber Using dual fiber optic elements with different attenuation coefficients allows the monitoring of sensor length or wear Optical energy from wearing layer or fiber illuminated (LED), I o Wearing surface (mating surface) Part-1 Part-2 Optical fiber with attenuation α 1 Optical fiber with attenuation α 2 Sensor probe imbedded in the part Transmission fibers (sensing element to electronics) Sensing element length, L Optical signal processing electronics Optical emission Solve for length L Light intensity of sensing element-1 I = I * -α 1*L 1 0 I = I * -α 2*L 2 0 Light intensity of sensing element-2 => L = ln I 1 I I I 2 α 2 -α 1 α 2 Note: I 0 is the same for both sensing elements (same light source) 03-14-2012 13

Laboratory Proof of Concept Tests K Science Wear Sensor Signal Repeatability and Sensing Element Length Determination Experiments 17.0 16.0 K Sciences and Siemens conducted initial lab proof of concept tests Detector Output, mv 15.0 14.0 13.0 12.0 * 0.5 db/cm fiber exposed to incandescent lamp light source. * InGaAs Detector with an operating wavelength range of 700-1800nm (near infrared region) used. * Gain Setting: 50dB (gain of 4.75 x 10 5 V/A +/-2%) Test Run-1 Test Run-2 Test Run-3 Test Run-4 Test Run-5 Test Run-6 Test Run-7 Test Run-8 Test Run-9 Test Run-10 70 60 (Experimen t Set #2 D ata, In GaA s detector) 11.0 10.0 40 0 20 40 60 80 100 120 Time, s 30 Measurement Stability and Repeatability Tests Intensity Output, mv 50 20 10 4.977, 0.5dB/cm fiber 4.602", 0.5dB/cm fiber 4.086, 0.5dB/cm fiber 0 0 60 120 180 240 300 360 420 480 540 600 Time in seconds 3.571, 0.5dB/cm fiber Scaled fiber length representation 2.993, 0.5dB/cm fiber Detector Output versus Sensing Element Length Test 03-14-2012 14

Laboratory Proof of Concept Tests Wear Compatibility Test Wear Probe Wear Probe High speed wear simulation test on a lathe (wear probe rubbing against spinning metallic surface). High speed wear simulation test on a grinder (wear probe rubbing against spinning abrasive surface). Sensing fibers assembled in this grove using high temperature cement glue 03-14-2012 15

Baseline Sensor Wear Demonstration Test Metal-to-Metal Wear Simulation Test: created wide uncertainty band in measurement Measured by Sensor Uncertainty band = 1.5 mm Target resolution 0.25 mm Wearing the fiber created cracks that reflected light and made the measurement very noisy Actual Feed rate (dial gage indicator) Siemens and K Sciences spent a great deal of effort to resolve issues Fiber bundle designs Siemens Data Energy, averaging Inc. 03-14-2012 16

Baseline Wear Sensor Replaced with an Alternate Wear Sensor Concept Fiber cable Fiber cable Wear probe Wearing parts Sensing elements in contact with wearing surface Wear probe Wearing parts Sensing elements Optical guide in contact with the wearing surface Baseline Fiber Optic Wear Sensor Design (K Sciences) The Baseline Sensor performed marginally in static tests. When the fibers were exposed to wear, the measurements became unusable Alternate Optical Wear Sensor Design (Siemens) Philtec Gap Measurement Technology Integrated with a Siemens Wear Probe Concept - Performs better in aggressive wear environment - Closer to practical demonstration than the K Sciences concept 03-14-2012 17

Sensor Design: Alternative Wear Sensor Mating part reflects light through Plug back to Probe Sensor Probe Transmission Line Optoelectronic Module Data Analyzer Result Display Emits light into Plug and receives reflected light Transmit light through hot zone, up to 500C (high temperature fiber cable) Transmit light outside of engine (low temperature fiber cable) Generates probing light (880nm diode) Receives reflected light and converts it into electrical signals. Digitizes and preprocesses signals Data Processing and Storage System Mating part surface Optoelectronic Module User Interface PC Fiber Cable Background reflection measured with no light source Plug Ratiometric method used to measure distance from fiber end to wearing part Probe 03-14-2012 18

Alternate Sensor Wear Simulation Test Separating the optical fiber with an optical wear plug greatly improved the measurement stability 5.0 Preliminary probe measured uncertainty of 0.3mm 4.5 Sensor Output, Volt Raw Output, V 4.0 3.5 3.0 2.5 Time, S 2.0 0 2 4 6 8 10 Wear, mm Optical Guide Wear, mm Wear simulation test using bench grinding machine Alternate sensor design improved wear monitoring capability over the Baseline (K Sciences) design in a dynamic wear simulation environment (b) Sensor output correlation to probe tip wear progression Uncertainty achieved = +/-0.3mm. 03-14-2012 19

Alternative Wear Probe Improvement Baseline/ K Science Alternative/ Philtec Criteria Specifictions Distance operating range, mm 0-10 0-10 0.2-12.7 Maximum operating temperature, C 1000 1000 800 Instability, room temperature, um 25-250 740 2 Instability, operating temperature, um 25-250 XX 30 Uncertainty during wear, um 25-250 1500 300 At room temperature the sensor output Optical properties of the quartz media and drifted less than 2 um during 48 hours. reflective surfaces are temperature dependent; so calibration at operating temperatures is needed. 03-14-2012 20

Alternative Wear Probe High Temperature Tests Test Objective: Evaluate sensor response and integrity in high temperature environment Philtec Test Results: 1. Probe materials (fused silica fiber, optical guide, ceramic cement, and Hast-x probe housing) are capable to operate up to 1000C. 2. Probe performance stable for up to 600C. 3. Small drift observed at 800C and up due to thermal radiation noises and other setup issues. PC Data File Philtec Sensor Electronics A vertical stack of heaters used to heat the sensor tip plus one meter of cable length. 03-14-2012 21

Alternative Wear Probe: High Temperature Test - Probe tip exposed to 450C for 12 hrs Before heating After 450C heating Sensor response before exposed to high temperature test Sensor response after heated to 450 o C for more than 12 hours The calibration curve before and after heating remained the same and the response during heating was as expected. 03-14-2012 22

High Temperature Test: Probe tip exposed to 780C for 4 hrs Temperature during the heating cycles Sensor SNR Voltage Sensor calibration curve before the high temperature test. The linear range spanned 78 to 171 mils (2mm to 4.3 mm) Sensor response shifted due to background radiation that is now compensated Target Gap, mils Test data with the sensor set to 2 volt, middle of the linear range Some drift observed at 800C and up due to thermal radiation noises and other setup issues. Work in progress to resolve the issues. 03-14-2012 23

Transition Floating Seal Wear Monitoring Application Example of prototype sensor application configuration Wear Monitoring Algorithms wear probe Fiber optic transmission cable Transition Exit Floating Seal Wear Signal processing electronics PC / Data Processing / Storage Device 03-14-2012 24

Materials and Installation Fiber Cable: Stainless Steel, Quartz Fiber Probe Tip: Hastelloy, Quartz Fiber Wear Plug: Quartz Measuring outer seal wear 03-14-2012 25

Transition Floating Seal Wear Monitoring Application Route the cable along inside casing wall (or route straight-up using tube) Probe can be mounted on the floating seal with the probe tip flesh against the wearing surface. - Threaded probe tip, 0.375 diameter - Flex hose cable, 0.25 diameter The cable will be routed using a guide tube to the outside casing For simple illustration purpose only 03-14-2012 26

Installation Design: Optical Wear Sensor Routing Access Proposed routing to outer seal Requested installation of 4 sensors, but only 2 sensors were approved by customer Outer seal high-temperature cable length is 1.5 m 03-14-2012 27

Risk Assessment: FMEA Performed and Presented to Customer Highest Risk Item: wear location does not wear Moderate risk is sensor liberation, but it is mitigated by the cable holding onto the sensor 03-14-2012 28

Demonstration Engine Sensor Validation Tasks: Component instrumentation drawings (part modification, instrumentation routing, etc.) Risk assessment Design review for installation Customer acceptance - Level of Authority (LOA) Component and engine instrumentation installation Monitor and evaluate sensors performance Final test result report Basket 2 is installation location Wear Sensor Being Installed in a Siemens SGT6-5000F Turbine During Current March Outage (US Location) 03-14-2012 29

Develop Multi-Function Crack and Temperature Monitoring Sensor (JENTEK) The multifunction magnetic sensor is an eddy current sensor based on JENTEK s Meandering Winding Magnetometer (MWM-Array) technology that determines cracking and surface temperature by monitoring changes in the electrical conductivity of the material under the sensor. The MWM-Array technology has especially arranged conducting windings that consist of a drive winding to create a magnetic field and multiple sensing elements. To monitor cracks, a time varying magnetic field is created by applying a current at a prescribed frequency to the drive winding; the resulting material dependent response is processed using a multivariate inverse method and pre-computed sensor response database to allow the conductivity to be measured independently over a wide dynamic range of nonlinear sensor responses. The change in conductivity can be related to temperature or crack initiation. When a crack, corrosion damage, an inclusion, surface roughness, or an internal geometric feature alters the flow of the eddy currents, then the inductive sensing coils sense an absolute magnetic field that is altered locally by the presence of the crack or other flaw. The measured quantities are absolute, and they are automatically compensated for lift-off (proximity) 03-14-2012 30

JENTEK Magnetic Sensor System High temperature transmission cable Spec: 500C, ~2m long, ~5mm cable bundle diameter Probe-to- Instrument Cable Instrument-tocomputer (USB) Cable MWM-Array Sensor Spec: 1000C, ~ 30mm x 30mm size, detects crack size of ~30mm long with a sensitivity of 0.5mm length by 0.25mm deep crack Probe Electronics Unit (can be placed next to the engine, from the outside) Impedance Instrument (can be placed away from the engine, such as the control room) Laptop with GridStation Software (PC/laptop sensor data access can be arranged to be done remotely ) These system components did not require that much development work. Directly adapted from existing system (prototype unit). Challenges: High temperature MWM array High temperature cable and attachments Signal to noise ratio in long (>1m) cable system 03-14-2012 31

Crack Sensor Transmission Cable Fabrication Cable material selection, twisted pair cable packaging, cable-to-probe unit adapter, and cable-to-sensor lead wire connection requires significant improvement. 03-14-2012 32

Online Parts Condition Monitoring System Parts Condition Monitoring Software / User Interface Wear Monitoring Module (wear assessment) Crack Monitoring Module (crack damage assessment) Wear Depth Measurement (convert voltage to wear in mm using sensor calibration curve) Wear Assessment Model (Task 4) Crack and Temperature Measurement (convert conductivity and lift off to crack and temperature reading - measurement grid calibration) Crack Assessment Model (Task 4) Data Acquisition System (BNC Connector) Data Acquisition System (BNC Connector) Photo Detector Impedance Instrument Unit (convert voltage/phase to conductivity and lift off) Optical Wear Sensor (optical signal) Multifunction Magnetic Sensor (voltage and phase angle) 03-14-2012 33