A basic introduction to steam



Similar documents
ENGINEERING INFORMATION Hot water and steam service

Desuperheater Online Program Sizing Guidance

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

VAD Variable Area Desuperheaters

Heating Water by Direct Steam Injection

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Testing methods applicable to refrigeration components and systems

VAD. Variable Area Desuperheaters

Using meters to measure steam flow

HS-901(A) BASIC STEAM HEATING SYSTEMS

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Refrigeration Basics 101. By: Eric Nelson

C. starting positive displacement pumps with the discharge valve closed.

Rusty Walker, Corporate Trainer Hill PHOENIX

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

How To Calculate The Performance Of A Refrigerator And Heat Pump

Steam System Efficiency. Bill Lumsden Leidos Engineering

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

DET: Mechanical Engineering Thermofluids (Higher)

Factory owners must ensure the boiler is:

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Vaillant s plain English guide to. simple, concise and precise

Chapter 3.4: HVAC & Refrigeration System

Steam System Best Practices Condensate System Piping

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

CO MPa (abs) 20 C

FLUID FLOW Introduction General Description

SAMPLE CHAPTERS UNESCO EOLSS

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

How To Design A Refrigeration System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

UNIT 2 REFRIGERATION CYCLE

Webpage: Volume 3, Issue IV, April 2015 ISSN

ENERGY SAVING WORT BOILING SISTEM IN BREWING FACTORY

PBX Series Quick Fit Connector Bimetallic Steam Traps

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Recover Heat from Boiler Blowdown Water

REGULATING VALVE APPLICATIONS

Hot water supply, distribution and use

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Blowdown vessels Meeting the requirements of HSE PM60

ABB Flowmeters Review of industrial processing flowmeters

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

FLASH TANK ECONOMIZER PRODUCT GUIDE

Characteristics of Evaporators

Thermal Dispersion Mass Flow

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

The soot and scale problems

REFRIGERATION (& HEAT PUMPS)

1 DESCRIPTION OF THE APPLIANCE

OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE. TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS

In-Line Air Separators

5.2. Vaporizers - Types and Usage

DESIGN OF FLUID SYSTEMS STEAM UTILIZATION

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

E-gas Instant Gas Water Heaters

How does solar air conditioning work?

How To Clean Water From An Ammonia Refrigeration System

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Chilled Water HVAC Systems

HEAVY DUTY STORAGE GAS

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

IGEMA BOILER LEVEL & TDS CONTROLS

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Air Eliminators and Combination Air Eliminators Strainers

Boiler Preparation, Start-Up and Shutdown

Float and Thermostatic Traps Series H, C and X

Steam System Design and Best Practices Related to Kiln Drying

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Forgotten savings: Heat recovery from surface blowdown

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

Flow Measurement Options for Pipeline and Open Channel Flow

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Energy Matters Heat. Changes of State

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

GOOD PRACTICE GUIDE THE CALIBRATION OF FLOW METERS

Session 2: Hot Water Supply

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

solarplus solar systems general features

Lesson 36 Selection Of Air Conditioning Systems

Contents and Nomenclature

Transcription:

A basic introduction to steam

FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666

Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable Easy to distribute Easy to control

Steam Wonderful Steam The magic of steam is that pressure and temperature are directly related, it is therefore easy to control temperature by controlling pressure. It is the ideal way to provide exactly the right temperature and thus deliver the right amount of energy for a wide number of applications.

Steam Wonderful Steam An application demands a precise temperature throughout the process. An example might be cooking toffee in a cooking pan. Too cool and the toffee isn t cooked. Too hot and the sugar will burn.

Steam Wonderful Steam A direct source of heat such as a gas flame would create hot spots.

Steam Wonderful Steam A direct source of heat such as a gas flame would create hot spots. With a thermal fluid, oil, or hot water, a temperature gradient would exist across a heat exchanger as the temperature was given up.

Steam Wonderful Steam A direct source of heat such as a gas flame would create hot spots. With a thermal fluid, oil, or hot water, a temperature gradient would exist across a heat exchanger as the temperature was given up. Steam provides the answer. If the process requires a precise temperature, all that is required is to control the pressure accurately.

Sensible Heat & Latent Heat To understand this relationship between temperature and pressure, one needs to understand the concept of Sensible heat and Latent heat Sensible heat can be defined as the energy required to raise a given mass of a liquid to it s boiling point. Latent heat is the amount of energy required to change that same mass of liquid to a vapour.

Sensible Heat & Latent Heat In simple terms, latent heat is the energy required make the molecules of water overcome the mutual attraction that kept them together as a liquid.

Sensible Heat & Latent Heat The liberated molecules retain this added latent energy only giving the latent energy up as the molecules come together as water again.

Sensible Heat & Latent Heat Water boils at 100 Celsius at atmospheric pressure The sensible energy in the water at 100 Celsius at atmospheric pressure is 419 kilo Joules per kilogram. 419 kilo Joules per kilogram

Sensible Heat & Latent Heat The additional latent energy required to turn this boiling water into the dry gas called steam is 2257 kilo joules per kilogram. The total energy in the steam is 2675 kilo Joules per kilogram. 2675 kilo Joules per kilogram = 2257 kilo Joules per kilogram + 419 kilo Joules per kilogram

Sensible Heat & Latent Heat The other major change in our kilo of water is that at 100 Celsius it had a volume of just over 1 litre. 1 kg 1673 ltr When converted to steam it has a volume of 1673 litres!. 1 kg 1 ltr

Sensible Heat & Latent Heat If the pressure is increased, it will require an increase in the sensible heat, in order to liberate the molecules of water.

Sensible Heat & Latent Heat At a 10 bar static pressure, water s s boiling point is 184 Celsius, it would require a 782 kilo Joules of heat energy to bring it to boiling point and an additional 2008 kilo Joules of energy to change it all into a dry saturated vapour. 2790 kilo Joules per kilogram = 2008 kilo Joules per kilogram + 782 kilo Joules per kilogram The total energy is 2790 kilo Joules per kilogram

Sensible Heat & Latent Heat If only 90% of the extra energy is added, then only 90% of the water will be turned into steam

Sensible Heat & Latent Heat Remember that during this process of chemical change from a liquid to a vapour, our kilo of water has remained at a constant temperature. Similarly, having produced a kilo of steam, it will remain at a constant temperature until we have condensed all of the steam back to water and extracted all of the latent heat.

Sensible Heat & Latent Heat Control the pressure very accurately The temperature also will be controlled very accurately.

Sensible Heat & Latent Heat When the steam hits a cool surface, the latent heat is given up and the steam turns back to water The resulting condensate being returned to the boiler for re-use.

Sensible Heat & Latent Heat When steam as a dry vapour hits a hotter surface, then the steam can get hotter than it s s saturation temperature. The result is superheated steam Superheated steam is most often produced by passing the steam through a second heat exchanger in the boiler.

Sensible Heat & Latent Heat Superheated steam will also be produced if the pressure of dry saturated steam is reduced by a restriction orifice or pressure reducing valve.

Sensible Heat & Latent Heat Superheated steam is desirable in power plant such as steam turbines and may be useful in reducing condensate problems in distribution but is undesirable in heat exchange applications where it gives up it s temperature more reluctantly than saturated steam.

Sensible Heat & Latent Heat Having used the latent heat of the steam, we are left with condensate and it s s sensible heat.

Sensible Heat & Latent Heat The condensate drains into the steam trap where it is separated from the steam

Sensible Heat & Latent Heat 100 Condensate being released through a steam trap is at atmospheric pressure, it s temperature will be 100 Celsius, and it will contain 419 kj/kg of sensible heat. 100

Sensible Heat & Latent Heat 170 If the condensate being released through a steam trap is at 7 bar gauge, it s s temperature will be 170 Celsius, and it will contain 721 kj/kg of sensible heat. 170

Sensible Heat & Latent Heat 170 When the condensate line on the other side of the steam trap is at atmospheric pressure, a kg of condensate have a maximum temperature of 100 Celsius and can only contain 419 kj/kg of sensible heat. 100

Sensible Heat & Latent Heat 170 As the temperature drops to 100 Celsius, the difference between the sensible heat at 7 bar g, (721 kj/kg) and the sensible heat at 0 bar g (419 kj/kg) i.e. 302 kj will turn 12% of the boiling condensate back into steam. Flash Steam 100

Sensible Heat & Latent Heat 170 As the volume of a kg of steam is roughly 1600 times greater than a kg of condensate, the 12% by mass of flash steam will have a volume over 160 times that of the 88% condensate. This frequently the cause of the noise heard from pipework adjacent to steam traps. 100

Making Steam Producing the steam for process applications

Making Steam Water from a feed tank is pumped under pressure into the steam boiler

Making Steam The level of the water in the boiler shell will be controlled by level controls or switches

Making Steam From a cold start, the boiler will be fired with the steam outlet valves closed.

Making Steam First, the water is raised to boiling point at atmospheric pressure.

Making Steam As the water boils the adding more heat causes bubbles of steam to form which float to the top and are released into the steam space.

Making Steam Because the outlet valve is closed and because the chemical change from a liquid to a vapour causes an expansion from 0.001 m3 per kilo to 1.673 m3 per kilo.

Making Steam With this change of volume as water expands into steam, the pressure within the boiler will start to rise and will continue to increase until the pressure controls on the boiler turn down the heat source.

Making Steam At this point, the boiler is fully charged with steam at a pressure of maybe around 10 bar and a temperature of around 200 Celsius.

Making Steam Downstream is a cold pipeline, maybe with a little cold condensate left in.

Making Steam Imagine the consequences if the boiler steam valve is opened up too quickly and all the energy within the boiler is suddenly released into the distribution system.

Making Steam A good boiler operator will gently open the valve and allow the temperature to rise slowly to minimise thermal shock. This procedure will allow condensate which will be formed as the system warms up to be drained away.

Making Steam Opening the valve too quickly could create sonic velocities within the pipeline. A slug of condensate being fired down the pipeline at the speed of a bullet often has devastating effects.

Making Steam Once the distribution system is up to temperature, the steam s work can commence.

Quality of Steam Boiler capacity, pipe sizing, good distribution system design are all critical factors in the production of good quality saturated steam

Quality of Steam If steam demand increases beyond the capacity of the boiler, the pressure drops, the size of the steam bubbles increases forcing the apparent water level to rise within the boiler.

Quality of Steam With a subsequent reduction in steam space and greater surface turbulence, the larger bubbles splash out of the water surface throwing water droplets into the steam. The increased velocity out of the boiler will carry many of these droplets into the distribution system reducing steam quality.

Quality of Steam Within the distribution system some heat energy will be lost in the pipelines creating condensate.

Quality of Steam The distribution pipework must be of adequate size such that any water carried over and or condensate forming from the steam as a consequence of heat loss from the pipes is not picked up by excess pipeline velocity and carried in the steam.

Quality of Steam Velocities in excess of 40 metres per second are likely to cause reduced steam quality due to the increased water droplets in suspension. Water droplets flying down a pipe line at say 50 metres per second ( 120 miles an hour ) continuously are bound to cause wear and erosion.

Quality of Steam Most authorities consider that a steam velocity of 25 to 35 metres per second provides for acceptable pressure drop, acceptable heat loss, and minimum pick up of condensate. This velocity may be reduced to minimise pressure loss where distribution lines are very long.

Quality of Steam Good design of the distribution system with particular attention to drainage improves steam quality dramatically. For efficiency and safety it is vital that all condensate is removed from the distribution mains as quickly as possible.

Quality of Steam 1 in 500 Lines should have a fall in the direction of flow, typically 20 mm per 10 meters of pipe, have collecting legs every 40 to 50 metres and no untrapped low points where water can collect.

Quality of Steam Low points and collecting legs should be fitted with steam traps. In their most simple form, steam traps allow the passage of water to drain but won t t allow steam to pass. In most modern distribution systems the condensate and it s sensible heat will be returned to the plant room and used again for the production of steam.

Quality of Steam Before we leave the subject of distribution lines and trapping. On some systems there can be a further problem during that start up from cold. The condensate pipe may not self drain back to boiler feed tank. It may require some pressure in the steam line to force the condensate through the steam trap. As the system is being primed slowly it may be same time before that pressure is available, at the same time we are producing large quantities of condensate which can t get away. Even with a gentle start up there could still be some water hammer as condensate gets pushed through the system.

Quality of Steam Branch lines should always be connected to the top of the steam main to provide the driest steam to the process.

Quality of Steam Distribution lines should be well insulated to minimise the amount of condensate being formed (and to save energy).

Quality of Steam Imagine standing water in a low point in the pipe. The demand is low so the steam passes easily over the standing water.

Quality of Steam Demand increases, the resulting increased velocity starts to push the water into a plug.

Quality of Steam This plug which possibly weighs several kilos gets larger as it picks up more of the condensate in the line may be travelling down the pipeline at around 90 miles per hour. The impact caused by the kinetic energy can be sufficient to bend the spindles of valves, break joints, and definitely cause mischief with flowmeters.

Quality of Steam Standing water in distribution pipework may not only be as a result of a low section of pipe. Badly installed pipe fittings, strainers, valves, and flowmeters may all contribute.

Quality of Steam Strainers & Globe valves should be fitted on their side to prevent damming of the flow. This example also shows that the strainers efficiency is reduced by being waterlogged

Quality of Steam The damming effect of of a concentric reducing fitting. The benefit of an eccentric reducing fitting.

Quality of Steam Orifice plates as well as causing a damming effect will be totally ineffective for measurement. A drain hole in the bottom cures the problem and the change in coefficient of discharge can be allowed for.

Quality of Steam Pressure reducing valves and steam control valves must always be preceded by a drain leg. Better still is the installation of a proprietary steam separator which is designed to remove any water droplets suspended within the steam flow which would cause erosion of the valve seats.

Steam Terminology Mass Density Specific Volume Pressure Mass flowrate Enthalpy Flowmeter M is the quantity of steam by weight in kgs pb is the mass per unit of volume kg/m3 at reference conditions pf is the mass per unit of volume kg/m3 at flow conditions Vb is the volume per unit of mass m3/kg or dm3/kg at reference conditions Vf is the volume per unit of mass m3/kg or dm3/kg at flow conditions Pb is the pressure kpa or bar at base conditions Pf is the pressure kpa or bar at flow conditions Qm is the mass flowrate kg/hr hb is the specific enthalpy kj/kg at reference conditions hb is the specific enthalpy kj/kg at reference conditions Kf is the K-factor K (vortex) pulses/m3 Sv is the 20 ma span (vortex) m3/hr Sm is the 20 ma span (DP) kg/hr

Steam Tables Steam tables are the most convenient way of showing the properties of steam. Unlike ideal gas, the properties of steam are not linear to changes in pressure or temperature. A typical dry saturated steam table will look something like this. Pressure Temperature Enthalpy Gauge Absolute Water Evaporation Steam Density bar bar Celsius kj/kg kj/kg kj/kg m3/kg 3 4.013 143.75 605.3 2133.4 2738.7 0.461 5 6.013 158.92 670.9 2086.0 2756.9 0.315 10 11.013 184.13 781.6 2000.1 2781.7 0.177 15 16.013 201.45 859.0 1935.0 2794.0 0.124

Metering Regardless of the chosen method of steam flow measurement, steam quality plays a major part in the meter s performance. The steam should be dry and the pipeline free of condensate. Wet steam will cause erosion particularly to orifice plates. Wet steam s s increased density will cause errors with DP type meters. Wet steam has more sensible heat per unit of volume and less latent heat per kilo of mass. Condensate could block the sensing holes on pitot tubes. With the high velocities associated with Vortex meters, any condensate not drained upstream will almost definitely be come entrained into the steam flow.

Pipeline considerations. Metering Most principles of steam metering require a good velocity profile. The velocity profile will be affected by bends, valves, tees, reducers and the often forgotten friction due to roughness of the pipe wall. It is also vital that the pipe internal diameter is correct for the meter being used.

Metering Methods of steam measurement Orifice plate ISA of long radius nozzle PTC-6 nozzle Venturi nozzle/classical venturi Pitot tube Target meter Variable area Spring loaded variable area Turbine meter Vortex meter Ultrasonic flowmeter (only dry steam) (dry and wet steam) (technically best option) 6 nozzle (technically best option) (dry and wet steam) (only monitor function) (not a serious option) (not a serious option) (is an option, mechanical ) (not recommended) (dry steam, good option) (option for larger pipes, HP)

Metering An alternative to the measurement of the steam is to measure the boiler feed water or condensate return. Boiler feed. High accuracy at point of measurement but allowance must be made for blow down of boiler and for any water droplet carry over. Condensate return. High accuracy but condensate must be free of any flash steam. Ideal for measuring consumption of a single appliance

Metering Secondary Instrumentation Any primary flow meter is only as good as the instrumentation used to process or display the flow signal. In virtually all applications a flow computer should be used to compensate for any variations in density. With saturated steam it is only necessary to use either a pressure input or a temperature input. With superheated steam, both pressure and temperature inputs should be used. Some principles of meter will benefit from linearisation by the flow computer.

Voor meer informatie, ga naar Energiemetingen op www.flowmeters.nl