USER S GUIDE 94150 Humidity and Temperature USB Datalogger



Similar documents
Datalogger Graph Software Help

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5


User Guide. Temperature and Humidity Datalogger. Model 42280

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Temperature Datalogger Users Manual

EL-USB-1-LCD Temperature Data Logger with LCD

USB-500/600 Series Low-Cost Data Loggers and Accessories

EL-USB mA Current Loop USB Data Logger

SupcoLog Logger Interface Software

USB-500 Series Low-Cost Data Loggers and Accessories

HOBO U14 Data Logger User Manual

1. SAFETY INFORMATION

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

Model SL355 Noise Dosimeter/Datalogger

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Data-logger evaluation software GSoft V2.8

DataView DVTH Data Logger for Temperature and Humidity

Current Monitoring Kit

AUDITVIEW USER INSTRUCTIONS

WAM Remote Wireless Asset Monitoring. Website User Guide

Alarm Security Kit - NVR

Audience Response System (Turning Point) A Quick Start Guide

Preparing Log-ic 360 USB Loggers for Use

AUDITVIEW USER INSTRUCTIONS

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

Data Logging Solutions from Lascar Electronics

4-Channel Thermometer / Datalogger

Current Monitoring Kit QUICK START GUIDE

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Cellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev Temperature@lert

User's Guide DylosLogger Software Version 1.6

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

User s Manual. Management Software for ATS

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Using USB Flash Drives

SubCue Analyzer Software - Introduction

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Model: Manual DC: WIRELESS COLOR FORECAST STATION

ezsystem elab16m Project 1F: Alarm System (Full Project description)

A-Series Data Loggers PRODUCT MANUAL

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

User Guide Reflow Toaster Oven Controller

DG-100 Data Logger User Manual. Version 1.2

PowerShield SNMP Adaptor

OARTEC SIMULATOR TRAINING MONITOR USER MANUAL Version 1.05

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Wireless Data Logger Monitoring Systems

Copyright. Copyright LogTag Recorders. All rights reserved.

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

Accessing vlabs using the VMware Horizon View Client for OSX

etrex 10 quick start manual

ExStik TM ph Waterproof Meters

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

Estação Meteorológica sem fio VEC-STA-003

How to Install and Set up a Jabra Go 6400 and Pro9400 Series Headset with an Avaya 96x1 Series IP Phone

POWER NETWORK iPcams 2/10 Rev. A

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

PTR/DTR. Printing Thermometer Software. Software User Manual

Weather Capture Software Guide Version 1.4 Revision: June

SA-9600 Surface Area Software Manual

Surf it Easy. User Guide

icom Software Update Guide Updating the icom using the Service Tool (ist)

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

FT-1000/GPS-N. System of remote monitoring and control of physical

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

RFID Logger Software User Manual Rev 1.0

Data Analysis Software

Integrating Sound Level Meter and Datalogger

STANDARD OPERATING PROCEDURE FOR USE OF LOG TAG ANALYZERS AS PART OF THE INTER HOSPITAL TRANSFER PROGRAM

Using the UPSMON-Plus Monitoring Software

Panopto Recording. Click the Panopto Recorder icon found on the Desktop. Click the Log in with Blackboard button. Page 1

SNMP Web Management. User s Manual For SNMP Web Card/Box

Names of Parts. English 1. Mic. Record Button. Status Indicator Micro SD Card Slot Speaker Micro USB Port Strap Hook

USB Edition TM-STD30 User Guide

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

Using the T&D Thermo App with TR-7wf Data Loggers

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

User s Manual. 1. Introduction 2. Product Features 3. System Requirements. 4. Installing IrDA Wireless Connection:

Blood Glucose Monitoring Systems

WindLog User s Guide

SYSTEM COMPONENTS. Gateway. Sensors. Repeater Figure 1

Infinity Touch Control Field Software Updates Version 10 rev

Download Software 2.33 For Vigil civil I, II, 2 + & Military II, II+, II+c -

Data Loggers for Real Time Temperature Monitoring - WiFi

Health Monitoring Demo for ice40 Ultra Wearable Development Platform User Guide. UG103 Version 1.0, September 2015

INF-USB2 and SI-USB Quick Start Guide

Field Calibration Software

Transcription:

USER S GUIDE 94150 Humidity and Temperature USB Datalogger

FEATURES Memory for 32,000 readings (16000 temperature and 16,000 humidity readings) Dew point indication Status Indication USB Interface User-Selectable Alarm Analysis software Multi-mode to start logging Long battery life Selectable measuring cycle: 2s, 5s, 10s, 30s, 1m, 5m, 10m, 30m, 1hr, 2hr, 3hr, 6hr, 12hr, 24hr DISCRIPTION 1. Protective cover 2. USB connector to PC port 3. Start button 4. RH and Temperature sensors 5. Alarm LED(red/yellow) 6. Record LED(green) 7. Mounting clip 2

LED STATUS GUIDE Green LED Red/Yellow LED LED STATUS GUIDE LEDs Indication Action Both LED lights OFF Logging not active Or Low Battery One green flash every 10 sec. * Logging, no alarm condition** Green double flash every 10 sec. * Delayed start 3 Start logging Replace battery and download the data To start, hold the start button until Green and Yellow LED flash

Red single flash every 10 sec. * -Logging, low alarm for RH*** Red double flash every 10 sec. * -Logging, high alarm for RH*** logging, it will stop automatically. No data will be lost. Replace battery and download data Red single flash every 60 sec. - Low Battery**** Yellow single flash every 10 sec. * -Logging, low alarm for TEMP*** Yellow double flash every 10 sec. * -Logging, high alarm for TEMP*** Download data Yellow single flash every 60 sec. - Logger memory full * To save power, the logger s LED flashing-cycle can be changed to 20s or 30s via the supplied software. ** To save power, alarm LEDs for temperature and humidity can be disabled via the supplied software. 4

***When both temperature and relative humidity readings exceed alarm level synchronously, LED status indication alternate every cycle. For example: If there is only one alarm, the LED blinks for one cycle and alarm LED will blink for next cycle. If there are two alarms, LED will not blink. First alarm will blink for first cycle and the next alarm will blink for next cycle. ****When the battery is low, all operations will be disabled automatically. NOTE: Logging automatically stops when the battery weakens (logged data will be retained). The supplied software is required to restart logging and to download logged data. ***** To use the delay function. Run the datalogger Graph software, click on the computer icon on the menu bar (2nd from left) or select LOGGER SET from the LINK pull-down menu. The Setup window will appear, and you will see there are two options: Manual and Instant. If you select the Manual option, after you click the Setup button, the logger won't start logging immediately until you press the yellow button in logger's housing. 5

SPECIFICATIONS Relative Humidity Temperature Dew point Temperature Logging rate Overall Range 0 to 100% Accuracy (0 to 20 and ±5.0% 80 to 100%) Accuracy (20 to 40 ±3.5% and 60 to 80%) Accuracy(40 to 60%) ±3.0% Overall Range -40 to 70 (-40 to 158 ) Accuracy(-40 to -10 ±2 and +40 to +70 ) Accuracy(-10 to +40 ±1 ) Accuracy (-40 to +14 ±3.6 and 104 to 158 ) Accuracy(+14 to +104 ±1.8 ) Overall Range -40 to 70 (-40 to 158 ) Accuracy(25, 40 to ± 2.0 100%RH) (±4.0 ) Selectable sampling interval: From 2 seconds up to 24 hours 6

Operating -35 to 80 (-31to 176 ) temperature Battery type 3.6V lithium(1/2aa)(saft LS14250, Tadiran TL-5101 or equivalent) Battery life 1 year(typ.) depending on logging rate, ambient temperature & use of Alarm LEDs Dimensions/We 101x25x23mm (4x1x.9 )/ 172g ight (6oz) BATTERY REPLACEMENT Only use 3.6V lithium batteries. Before replacing the battery, remove the model from the PC. Follow diagrammatic and explaination steps 1 throught 4 below: 1. With a pointed object(d.g. a samll screwdriver or similar), open the casing. Lever the casing off in the direction of the arrow. 2. Pull the data logger from the casing. 3. Replace/Insert the battery into the battery compartment observing the right polarity. The two displays briefly light up for control purposes(alternationg, green, yellow, green). 7

4. Slide the data logger back into the casing until it snaps into place. Now the data logger is ready for programing. NOTE: Leaving the model plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. 1 2 3 4 WARNING: Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. 8

Sensor Reconditioning Over time, the internal sensor may be compromised as a result of pollutants, chemical vapors, and other environmental conditions which can lead to inaccurate readings. To recondition the internal sensor, please follow the procedure below: Bake the Logger at 80 C (176 F) at<5%rh for 36 hours followed by 20-30 C (70-90 F) at>74%rh for 48 hour ( for re-hydration) If permanent damage to the internal sensor is suspected, replace the Logger immediately to insure accurate readings. 9