The Myth of Vapor Permeation and Thermal Insulation

Similar documents
APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SOLVING SECONDARY CONTAINMENT PROBLEMS

CONDENSATION IN REFRIDGERATED BUILDINGS

Selecting a Moisture Barrier Bag

pdi PLASTIC DRUM INSTITUTE Plastic Drum Paneling Issues

CONDENSATION. Section Break (Next Page)

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CHAPTER 3 MOISTURE TESTING

Water vapor transmission rate through plastic film and sheeting using a modulated infrared sensor

Mold Preventing I nterior System

PAAM COMMERCIAL PRIVATE LIMITED

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Solid shape molding is not desired in injection molding due to following reasons.

Chapter 4: Transfer of Thermal Energy

Dew-Point Measurement Solutions

Product Guide Specification

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

3 Single-Coated Foam Tapes

Determining the Right Molding Process for Part Design

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

NAN YA NYLON 66 Engineering Plastics. Flame Retardant.High Toughness.Heat Resistant. Impact Resistant.Moldability.Low Warpage

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Plastics and Polymer Business. Properties enhancement for Plastics

Barrier Coatings: Conversion and Production Status

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Building Owners Guide to a Duro-Last System!

Best Available Technology for Sodium Hypochlorite Storage Tanks

SANDWICH PANEL FILLING MATERIALS

Double Coated Urethane Foam Tapes

4 Thermomechanical Analysis (TMA)

Open-cell spray foam & what every contractor

High Performance PSA in Sheet Membrane in Water Protection

EVERYDAY ENGINEERING EXAMPLES FOR SIMPLE CONCEPTS

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Glossary of Heating, Ventilation and Air Conditioning Terms

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Answers to Your Questions from the Webinar

Spandrel Glass Types and Recommendations

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

CHAPTER 7: Building Systems ROOFING SYSTEMS

The Effect of Moisture on Blistering During the Heat-sealing of Paper and Foil Containing Packaging

Molds and mildew are fungi that grow

Adding value to the finest homes in Virginia for 52 years! years

HEAT TRANSFER ANALYSIS OF COLD STORAGE

Automobile Air Conditioning Primer

Underwriters Laboratories Testing Information

AND MEMBRANES ROOFING UNDERLAYS.

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

Dimensional Change Characteristics for Printed Circuit Board Films

Foam Injection Molding:

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

FIELD TESTING SERVICES

03/05/14 REVISOR RSI/JC RD3945

Infrared Moisture Detection

THE EFFECTS OF RETORT CONDITIONS ON CLEAR HIGH BARRIER LAMINATED STRUCTURES

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Calculating Heat Loss by Mark Crombie, Chromalox

Waterproofing construction Joints

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Roof Systems Overview

1. INTRODUCTION ABSTRACT

Question: Can a gymnasium floor be restored after being exposed to water damage?

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Meeting the Fire Code with Continuous Foam Plastic Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

3M Electrically Conductive Adhesive Transfer Tape 9703

CHANNEL LETTERING INDOOR & OUTDOOR TRADE SHOW DISPLAYS CONSTRUCTION SIGNAGE VEHICLE GRAPHICS REAL ESTATE / DISPLAYS WINDOW GRAPHICS POSTERS

New Developments in Adhesive Resins for Oriented Barrier // PP Film Applications. Development Center Materials Lab.

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Understanding High Perm vs. Low Perm

Requirements on secondary insulating glass sealants

Essential Performance Attributes of Preapplied waterproofing

Laminating Films - Heat Activated

CataLoG No. weight o.d. i.d. GLaSSwaRe

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Annex of the certificate (Page 1/6) Accreditation Scope

XFA 600 Thermal Diffusivity Thermal Conductivity

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Housing Fact Sheets. Moisture Condensation at the Windows

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Rehabilitation of an Aging Concrete Reservoir Adit Tower

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

1. INTRODUCTION 2. THERMAL TESTING

Renovating Your Basement

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN

Lecture 9, Thermal Notes, 3.054

ENCAPSULATING FOAM SYSTEM FOR ASBESTOS REMEDIATION

WOOD FLOORING ADHESIVES

Transcription:

Whitepaper The Myth of Vapor Permeation and Thermal Insulation Research and Development Department, USLCO US LINER COMPANY ABSTRACT Glass Fiber Reinforced Polypropylene (GFPP) composite is a light weight material with high impact resistance and very low moisture intake suitable for reefer liners over the traditional thermoset FRP panels. Polypropylene is one of the lowest moisture absorbing polymer available worldwide, which makes it ideal for interior panels for refrigerated trailers and truck bodies. Approximately five years ago, US Liner formally introduced Versitex, a continuous glass fiber reinforced polypropylene composite panel to answer the market demand. There have been many myths surrounding how vapor permeation through the reefer liners would affect the insulation performance of the urethane foam behind the liners. Specifically, Great Dane s ThermoGuard has claimed that it can improve thermal efficiency by simply putting a thin foil layer within its panel. This paper reports that water absorption is the major rate limiting mechanism of water vapor permeation through the composite liners instead of the diffusion mechanism that aluminum foil is trying to block. The paper has found that US Liner s Versitex product, generically known as GFPP has similar vapor barrier properties compared to a foiled product such as ThermoGuard. In addition, this paper will illustrate that GFPP s have significant benefit over thermoset FRP. Among GFPPs, there is little difference between foiled and non-foiled. While claims have been made that having a barrier layer in the wall panel may be the answer to a thermally efficient unit, there are several other factors that play equally meaningful a role. These include: type of insulation foam and blowing agents used during trailer manufacturing (no voids in wall, foam thickness), injection method, seal between scuff and wall, seal at all joints, no wall damage during use, door seal leakage, subpan leakage, and a variety of other issues. Insulation specifications and manufacturing method play a much greater role in efficiencies than does foil. This paper will show that when Versitex non-foiled GFPP is chosen as reefer liner material, there shall be no discernible difference between foiled and non-foiled ThermoGuard type panels in regards to loss of insulation efficiency. It is not recommended to pay the extra foil cost and hope for a payback.

WHO IS US LINER COMPANY US Liner Company (USLCO), a division of American Made LLC, located in Cranberry Township Pennsylvania, was founded in 1983 to develop unique materials that had never been used in the refrigerated truck/trailer market before. Traditional materials such as wood, fiberglass, steel, and aluminum had been used for over 40 years in these applications. USLCO was the first Company in North America to introduce reinforced thermoplastic materials into the refrigerated trailer market. Bulitex was the first high impact reefer panel introduced, followed by Versitex. Bulitex was designed to be the most impact resistance panel on the market and outperform any other product. USLCO developed and manufactured a continuous glass-reinforced woven thermoplastic material under the brand name of Bulitex in the late 1990s and now the company s next generation material called Versitex, these two materials have become the gold standard for toughness and durability in applications throughout many industries worldwide. Combining continuous glass fibers with tough, corrosion and moisture resistant polypropylene, in multilayer laminated structures, U.S. Liner has perfected a new class of versatile sheet materials. Utilizing this technology, we re helping our customers rethink even their most basic assumptions about sheet applications. And we re backing these technical developments with manufacturing capacity and signature service and support. The company s sales over the past several years have shifted from Bulitex Ballistic Textile to almost exclusively to Versitex whose name is derived as a versatile Textile product has displaced fiberglass, wood, steel and aluminum in numerous market applications by offering a stronger, lighter and low cost alternative to these traditionally used materials. Additionally, with today s environmental focus, virtually all of USLCO s products are 100% recyclable as it is manufactured from the two most common recycled materials, glass and polypropylene. Versitex literally ships around the corner and around the world! In fact, U.S. Liner products bring so many advantages to so many different applications.

HOW PERMEATION WORKS Permeation is the transfer of vapor or gasses through a barrier material such as polymer or composite to the other side. As illustrated in the figure below, the process involves three steps. 1. Absorption - The vapor molecules are absorbed onto the surface of the barrier material. 2. Diffusion - The absorbed molecules migrate through the medium to the opposite side due to concentration differential. 3. Desorption - The migrated molecules evaporate from the second surface of the barrier material. The entire process is driven by permeant (i.e. vapor/gas) concentration gradient. Vapor molecules from the high concentration side pass through the barrier material to the low concentration side until the partial pressures reach an equilibrium. Absorption Diffusion Desorption

FACTORS AFFECTING PERMEATION RATES All polymers are permeable to some degree. The permeability is affected mainly by the follow physical and chemical variables of vapor, barrier material, and environmental conditions. 1. Chemical Affinity between the Vapor and Barrier. If the vapor molecules and barrier material are more chemically compatible or contain similar polarity or functional groups, the vapor can be absorbed more easily onto the surface. In addition, this can cause the polymer chains in the barrier more likely to swell, allowing easier penetration of the vapor molecules. An example of polymer chains that would be most likely to swell from moisture penetration /absorption is Nylon and FRP. Whereas, water vapor absorption into GFPP Versitex Polypropylene or Polyethylene are repelling, thereby resulting in almost no absorption at all 2. Vapor Concentration. Both absorption and diffusion rates are proportional to the concentration gradients of the permeant. For example, in water vapor transmission test, relative humidity is one of the key driving forces. 3. Temperature. Higher temperature increases molecule mobility and hence faster diffusion. In a refrigerated condition, water molecules are less mobile or even freeze to solid if below freezing point. Note: This is critical as the foiled product propaganda indicates the use of TTMA RP No. 38 testing method to arrive at the graphs displayed in the literature. However, the test requires the use of heating the inside of the unit and not cooling. Thereby making the results ambiguous and unreliable 4. Pressure. Vapor pressure of the permeant serves as another driving force of transmission. The higher the pressure the greater the permeation rates. 5. Voids in the Barrier. Physical voids, cracks or pinholes created path without resistance, immediately compromising the barrier integrity. Thin foils do not provide the same characteristics as sheet. An example would be why there is expiration date on foiled food packaging products that have to remain fresh and moisture free. The thin foils used to keep fresh and intact only last a finite period of time. 6. Barrier thickness. The thicker the barrier the lower the transmission rates 7. Polymer Crystallinity. The amorphous phase of the polymer medium, where the polymer chains are more mobile, allows the diffusion of vapor molecules passing through. The molecules in the crystalline phase are organized, making it difficult for foreign molecules to pass through. Therefore, high crystallinity increases barrier properties. Versitex (GFPP) has the highest crystallinity.

8. Additives in Polymer. Platelet-like additives in polymer matrix results in torturous path for permeant to diffuse through, effectively increasing the barrier properties. USLCO uses very specific additives to improve even greater the barrier properties of its products. IT IS MORE RELIABLE THAN FOIL SINCE THE WHOLE PRODUCT ACTS AS BARRIER, NOT JUST THE FOILS. ****** See Lay-Up Illustrations Below ****** Special Polypropylene Surface Barrier Film Which Repels Moisture VERSITEX VR3 LAY-UP VERSITEX (VR3) is made up of 6 layers of solid glass filled polypropylene specially formulated to repel vapor. All 6 layers do this job, not just one layer of foil Fabric Backing to Allow for Best Foam Adhesion FOILED PRODUCT LAY-UP Foiled products like ThermoGuard rely on 1 layer to block moisture. VR3 uses all 6 layers

Water Absorption WATER ABSORPTION EFFECT ON WVTR (Water Vapor Transmission Rate) The first step of permeation is absorption of the permeant (i.e. vapor) into the medium. The graph below shows water absorption rate of two typical liner panel substrates, Polypropylene (PP) and Fiberglass (FRP) for 24 hours at 25 C per ASTM D-570. It s shown that FRP absorbs 20X more water than Polypropylene. This is consistent with the WVTR results and the permeation factors described in the next section. Typical FRP resins, vinyl ester or epoxy ester, are hygroscopic and thus have high affinity to water vapor molecules. On the other hand, Polypropylene (PP) is hydrophobic and repels water molecules, resulting in very little absorption and subsequent transmission. 0.25% 0.20% 0.15% 0.10% FRP PP 0.05% 0.00% Source: Crane ArmorTuf 65115 Technical Data Sheet, Generic PP Technical Data Sheet

PERMEATION MEASUREMENT The Diagram below illustrates a schematic of how the water vapor transmission rate (WVTR) test per ASTM F-1249 is conducted. The barrier material is placed and sealed in the test apparatus, separating it into two chambers. One chamber is filled with the permeant of interest, is this case water vapor, at a controlled temperature and relative humidity. The other chamber is flushed with nitrogen carrier gas, carrying the permeated water molecules to the detector. The infrared sensor detects the concentration of water molecules or gas in the carrier gas and converts the signal to transmission rate, presented in amount of permeant per unit area per time. The units for transmission rates are commonly presented as g/m2/day or g/100in2/day for water vapor, and cc/m2/day for other gases. Transmission rate is specific to the specimen measured at a given thickness. Test conditions of temperature and relative humidity all affects the results and have to be specified in the test. A more generic material property is presented as permeation rate, which takes into account of the barrier thickness and partial pressure. It is calculated from measured transmission rate multiplied by the thickness of the barrier material and divided by the partial pressure gradient of the permeant. Typical unit is g.mm/m2/day/mmhg.

To understand the effect of those permeation factors described above to the composite liner materials, US Liner Company contracted an independent third party laboratory to perform water vapor transmission rate (WVTR) test per ASTM F-1249. The test specimens consisted of VERSITEX glass fiber reinforced PP panels, a panel which had a foil barrier layer along, and a traditional thermoset FRP panels. Data below show significant differences of WVTR between the hygroscopic FRP and the two intrinsically water repellent PP composites. WATER VAPOR TRANSMISSION RATE TEST RESULTS Company: US Liner Date: August 31, 2007 Sample Description Composite plaques Test Temperature 100ºF ± 0.5ºF Test R.H. 100% Sample Test Area 50 cm 2 masked Sample Orientation As marked Test Results Accuracy ± 3% Test Procedure In order to report results as tested to the ASTM F-1249 (WVTR) standard test method, a minimum of triplicate testing of each sample is required. Notes Test results were corrected to sea level pressure (760mmHg). Average thickness is based on a minimum of five points distributed over the entire test area. Sample Designation Average Thickness (mils) ±.05 WVTR (WV Transmission Rate) The time rate of water vapor flow normal to the surfaces, under steady-state conditions, per unit area. gm/m 2 /day gm/100 Inch 2 /day VR3 78.81 1.06 0.068 VR2 56.63 1.38 0.089

WATER VAPOR TRANSMISSION RATE (WVTR) Date Compiled October 03, 2012 Test Procedure ASTM F-1249 (WVTR) Test Temperature 38C +/- 0.3C Test R.H. 100% Sample Test Area 50 cm2 masked Sample Orientation Smooth side to water vapor Test Results +/- 5% Accuracy Notes a. Test Results were corrected to sea level pressure (760 mmhg). b. Average thickness is based on a minimum of five points distributed over the entire test area c. Test accuracy is tighter on specimens with smooth surface to seal in the test apparatus. Sample Designation Average Thickness (mils) WVTR The time rate of water vapor flow normal to the surface per unit area, under steady state conditions g/sq.m/day g/100 sq. inch /day Foiled GFPP 90.90 1.28 0.083 Non-foiled 56.63 1.38 0.089 GFPP FRP 60 5.70 0.368 10 9 WVTR (g/m2/day) 8 7 6 5 4 3 2 1 0 Foiled GFPP Panel Non-Foiled GFPP Panel FRP

RESULTS - the results yielded that although the foil product was slightly better, it was well within the test specifications margin of error of +/- 3%, thereby establishing no discernable difference between the foiled and non-foiled GFPP panels. It was also noticed that in some tests of foiled GFPP there were pinholes present in some of the samples, as shown in the photo below Fig 1. These holes may be a result of the aluminum foil which is fragile and prone to tear and puncture. In addition, there is much evidence in the foils industry that if a foil is too thin, then the product can have pinholes. We believe this to be the case in the foiled (ThermoGuard) type products. It seems that the diffusion mechanism the foil trying to block does not determine rate factor. The effect of the thin foil barrier is trivial or negligible. This might not be true for foiled food packaging because the multi-layered films are only a few mils thickness and the foil thickness is significant to the total thickness. In the case of liner panels the thickness is in tens or hundreds mils, the contribution of the thin foil, about 0.35 mils, diminishes. In this case, the absorption mechanism dominates the permeation process. FIG 1. Holes 1mm-8 mm wide are seen in foiled GFPP through backlight. Magnification 37x s In the real world situation of a reefer, there are many other leak paths through edges or joints between doors, floor, walls, ceiling, and the refrigeration unit, more than merely through the wall surface. The entire system has to be tested as suggested by TTMA in the Appendix.

CONCLUSIONS: 1) In looking at the thermal permeability of Versitex (VR2 & VR3) panels compared to foiled ThermoGuard type panels, there is no difference between the permeability of these panels and thus the thermal efficiency of these panels when put side by side in to a trailer. 2) Considering the significant amount of factors that can affect the thermal efficiency of the trailer, there is no evidence given the results shown in this report that would suggest that a foiled panel provides any better thermal insulating properties than using a USLCO panel. 3) Spending extra money for a foil laminate panel assuming there will be savings down the road is not prudent. 4) Versitex is not the Traditional Liners that are highlighted in Great Dane ThermoGuard Literature and their White Paper. We believe it was FRP that was studied as Versitex has only been commercially available in its present for about 5 years now. Comparisons are misleading. 5) There are marginal to no additional fuel saving by using a foiled ThermoGuard type product (See Chart Below). There are many other factors that contribute to thermal efficiency of the trailer. The interior panel is just one.

% Loss of Insulation Efficiency 50 Loss of Insulation Efficiency 40 30 20 Foiled/ThermoGuard GFPP/Versitex 10 0 0 6 12 18 24 30 36 42 48 54 60 66 72 78 84 Months Note: Loss of Efficiency is Negligible Based on WVTR (ASTM F-1249) conducted by independent lab and extrapolation of data from Great Dane Whitepaper 2012 No Fuel Savings Based on Permeation Data Comparisons Source: Great Dane ThermoGuard Brochure640 DMD 1012

Appendix 1 Testing and Rating Heat Transmission of Controlled Temperature Vehicles Thermal insulation and air leakage performances of reefers may be tested per TTMA RP No. 38. In both tests, the vehicle shall be situated inside a test chamber within specific temperature ranges. The test cannot be conducted in the field since the control parameters are critical to establishing relevant data points. The TTMA RP No. 38 Test is twofold. First there is an air leakage test which basically pressurizes the trailer and determines the amount of leaks that are in the trailer. The second test is the Thermal Insulation Test which requires the use of heat, not cooling (as suggested by ThermoGuard Literature) In the air leakage test, air is introduced into the vehicle to maintain a steady state of pressure differential of 0.5 inch water column. The air flow rate is then recorded as the measurement of air leakage. The air leakage rate shall be used to determine the appropriate heat transmission correction factor. In the thermal insulation test, the energy required to maintain a steady state of interior-exterior temperature differential shall be measured with a watt-hour meter. The watt-hour and temperatures are then recorded for the calculation of heat transmission rate.

Appendix 2 Thermal Insulation Mechanism Polyurethane foams are commonly used for providing excellent thermal insulation in refrigeration applications. When urethane mixture is injected into the space between exterior and interior walls, chemical reaction takes place and foaming agent in the mixture starts forming bubbles while the isocyanates and polyols react to form a thermoset network. The control of the rise of foam and the size of bubbles determine how good the insulation efficiency will be. Best insulation is achieved by closed-cell foam, in which the gas in the bubbles is trapped by the urethane matrix, preventing it from flowing from cell to cell. Finer bubbles results in better insulation. Overtime, the foaming gas might escape through the cell walls and be replaced by atmospheric gas. Table below shows thermal conductivity values of the materials of interest. They can be divided into three categories. The thermal conductivity of solid polymers, including PU, are typically in the neighborhood of 200 mw/(m.k). Those of gases, including volatile foaming agents and air, are about an order of magnitude lower in the neighborhood of 20 mw/(m.k). Foams are mixtures of the above solid and a majority of gas. Their thermal conductivities fall on the vicinity of 30 mw/(m.k), following the rule-of-mixture. MATERIAL Thermal Conductivity mw/(m.k) Vacuum 0 Air 24 Pentane 14 Freon 7 Water vapor 19 Styrofoam 33 PU foam 30 Plastics 200 Vinyl Ester 250 Source: engineersedge.com Notes: ThermoGuard is a registered Trademark of Great Dane Limited Partners ArmorTuf is a registered trademark of Crane Corporation