Eye Doctor II Advanced Signal Integrity Tools

Similar documents
SPARQ Signal Integrity Network Analyzer. High-bandwidth, Multi-port S-parameters

Explore Efficient Test Approaches for PCIe at 16GT/s Kalev Sepp Principal Engineer Tektronix, Inc

Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

Application Note. PCIEC-85 PCI Express Jumper. High Speed Designs in PCI Express Applications Generation GT/s

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

How To Use A High Definition Oscilloscope

PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes

Keysight Technologies Characterizing and Verifying Compliance of 100Gb Ethernet Components and Systems. Application Brief

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

Impedance 50 (75 connectors via adapters)

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

LabMaster 10 Zi-A High Bandwidth Modular Oscilloscopes 20 GHz 100 GHz

High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

Using the On-Chip Signal Quality Monitoring Circuitry (EyeQ) Feature in Stratix IV Transceivers

Agilent Test Solutions for Multiport and Balanced Devices

Using Pre-Emphasis and Equalization with Stratix GX

2. The Vector Network Analyzer

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

High-Speed Inter Connect (HSIC) Solution

TI GPS PPS Timing Application Note

USB 3.1 Channel Loss Budgets

Agilent Measuring Noninsertable Devices

Equalization for High-Speed Serial Interfaces in Xilinx 7 Series FPGA Transceivers

Electrical Compliance Test Specification SuperSpeed Universal Serial Bus

Jitter Transfer Functions in Minutes

USB 3.0 CDR Model White Paper Revision 0.5

Application Note. Line Card Redundancy Design With the XRT83SL38 T1/E1 SH/LH LIU ICs

ni.com/sts NI Semiconductor Test Systems

High Speed Characterization Report

Electrical Compliance Test Specification SuperSpeed Universal Serial Bus

Mobile Phone Testing using Impedance Tuners

R3765/67 CG Network Analyzer

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Welcome to Pericom s PCIe and USB3 ReDriver/Repeater Product Training Module.

Experiment 7: Familiarization with the Network Analyzer

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

One Port Network Analyzer

Equalization/Compensation of Transmission Media. Channel (copper or fiber)

Dispersion penalty test 1550 Serial

ChipScope Pro Tutorial

Technical Innovation. Salland delivers fully Integrated Solutions for High Volume Testing of Ultra-fast SerDes Applications

Network analyzer and spectrum analyzer two in one

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

Appendix A. by Gordon Getty, Agilent Technologies

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Agilent 8753ET/8753ES Network Analyzers

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

Continuous-Time Converter Architectures for Integrated Audio Processors: By Brian Trotter, Cirrus Logic, Inc. September 2008

LAP NODO ÓPTICO 2/4 SALIDAS WT-8604JL

Transmitter Interface Program

a 1 a 2 2 Port b 2 b 1 Multi-Port Handset Switch S-Parameters Application Note AN20 Seven-Port S-Parameter Definition Introduction Summary:

Agilent Improved Method for Characterizing and Modeling Gigabit Flex-Circuit Based Interconnects. White Paper

Agilent 8720 Family Microwave Vector Network Analyzers

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

TAN-030 Application Note Performance Characteristics of the XRT7300 Device for DS3 Applications Rev. 1.00

February 2010 Number Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Comprehensive Analysis of Flexible Circuit Materials Performance in Frequency and Time Domains

AN952: PCIe Jitter Estimation Using an Oscilloscope

The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements

Agilent: Profile of Oscilloscope Firsts

GigaSPEED X10D Solution How

Feasibility of 25 Gb/s Serial Transmission Over Copper Cable Assemblies

Pericom PCI Express 1.0 & PCI Express 2.0 Advanced Clock Solutions

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis

A Network Analyzer For Active Components

3D modeling in PCI Express Gen1 and Gen2 high speed SI simulation

USB 3.0 Jitter Budgeting White Paper Revision 0.5

RF Communication System. EE 172 Systems Group Presentation

Scalar Network Analyzer

MANUAL FOR RX700 LR and NR

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent Time Domain Analysis Using a Network Analyzer

Colorfly Tablet Upgrade Guide

Transmission of High-Speed Serial Signals Over Common Cable Media

1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components

Michael Hiebel. Fundamentals of Vector Network Analysis

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Agilent Technologies N5990A Test Automation Software Platform. Getting Started Guide

AN862. OPTIMIZING Si534X JITTER PERFORMANCE IN NEXT GENERATION INTERNET INFRASTRUCTURE SYSTEMS. 1. Introduction

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

AND8336. Design Examples of On Board Dual Supply Voltage Logic Translators. Prepared by: Jim Lepkowski ON Semiconductor.

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Equalization: The Correction and Analysis of Degraded Signals. White Paper

Keysight Technologies Forward Clocking - Receiver (RX) Jitter Tolerance Test with J-BERT N4903B High-Performance Serial BERT.

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

mdm-mp3 minidirector with MP3 Player

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

Region 10 Videoconference Network (R10VN)

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

HIGH RELIABILITY POWER SUPPLY TESTING

Software User Guide UG-461

S-PARAMETER MEASUREMENTS OF MEMS SWITCHES

Transcription:

Eye Doctor II Advanced Signal Integrity Tools

EYE DOCTOR II ADVANCED SIGNAL INTEGRITY TOOLS Key Features Eye Doctor II provides the channel emulation and de-embedding tools Adds precision to signal integrity measurements Vital for anyone using an 8 GHz or higher oscilloscope Seamlessly integrates into Teledyne LeCroy s SDA II and SDAIII-CompleteLinQ software for eye diagram and jitter analysis Creates eye diagrams 50x faster than existing solutions Uses industry standard Touchstone format S-parameter files for fixture and channel definition Ability to read single ended or mixed mode S-parameter files DFE, FFE and CTLE Receiver Equalization Fully integrated into the user interface which allows the engineer to use additional Teledyne LeCroy tools for post-processing Use Eye Doctor II s Advanced mode to: Flexibly arrange components to allow any combination of de-embedding or emulation for Virtual Probing of any point in the test circuit not otherwise accessible Increase measurement accuracy through the use of a more advanced transmitter and receiver termination model that incorporates customerspecific characteristics Tools for Next Generation Serial Data Standards As signal speeds and data rates have increased to 5 Gb/s and greater while propagation mediums have remained unchanged, engineers have had to face new challenges with signal integrity. These faster signal speeds give rise to increased attenuation in the frequencies of interest. These effects were small enough to ignore at lower bit rates, but as rise times get faster and serial data rates increase, these effects must be accounted to avoid unacceptable intrusion into the design margin or completely unusable measurement results. As data rates increase, losses due to the serial data channels and fixtures increase at high frequency leading to eye closures. To truly understand jitter in the serial data signal, these effects must be removed. Clearly, design engineers Eye Doctor II main user interface. Integrates into SDAIII-CompleteLinQ For more information: teledynelecroy.com /sdaiii need new tools to remove the impact of test fixtures and cables, model the impact of serial data channels and fixtures, and simulate the receiver equalization. These capabilities greatly enhance the ability to make useful measurements in high-speed circuits. Additionally, newer serial data standards are requiring such tools in order to make compliance measurements. For example, PCI Express 3.0 will require the use of fixture de-embedding to refer the compliance measurement back to the pins of the transmitter; SuperSpeed USB requires the use of continuous time linear equalization being applied in the oscilloscope software, SATA 6 Gb/s and 6 Gb/s SAS require the emulation of the Transmitter Compliance Transfer Function (TCTF) to simulate the worst allow case channel for debugging compliance failures. 2

3

EYE DOCTOR II CAPABILITIES Rx EMPHASIS Emulating Serial Data Link Components EQUALIZATION When performing serial data measurements on the physical layer, the main goal is Rx to properly characterize the robustness of the serial data link. Measurements can either be CHANNEL made at the transmitter or the receiver as shown below. EMPHASIS EQUALIZATION CHANNEL Rx EMPHASIS EQUALIZATION CHANNEL De-embedding Fixture from Measurements FIXTURE OSCILLOSCOPE FIXTURE OSCILLOSCOPE De-embedding Fixture from Rx Measurements FIXTURE OSCILLOSCOPE CHANNEL FIXTURE OSCILLOSCOPE CHANNEL FIXTURE Cable De-embedding OSCILLOSCOPE Cable de-embedding is a standard feature on all SDA Zi/Zi-A oscilloscopes and is included with Eye Doctor II. Cable de-embedding gives CHANNEL the user the ability to quickly and easily remove the effect of cables by entering FIXTURE in an attenuation table or attenuation constants that are typically provided by the cable manufacturer. OSCILLOSCOPE 4

EYE DOCTOR II ADVANCED SIGNAL INTEGRITY TOOLS As signal speeds and data rates have increased to beyond 5 Gb/s while propagation mediums have remained unchanged, engineers have faced new signal integrity challenges, among these, increased attenuation in the frequencies of interest. These effects were small enough to ignore at lower bit rates, but now these effects must be accounted for to avoid unacceptable intrusion into the design margin or completely unusable measurement results. Adding/Removing Pre- or De-emphasis Transmitter designers sometimes employ the use of emphasis to precompensate for these effects. Eye Doctor II can remove de-emphasis or pre-emphasis from a signal measured at the transmitter output. This is useful when attempting to measure the jitter on such a signal in order to remove the DDj introduced by the de-emphasis. Eye Doctor II can also add de-emphasis or pre-emphasis to quantify the compensation necessary for specific serial data channels. Cable/Fixture/Serial Data Channel De-embedding In many typical high frequency measurement situations, engineers desire to connect as directly to their signal as possible and avoid the use of probes. However, even high quality test fixtures, channels, and cables have a negative impact on signal quality that increases with higher signal frequency. If the test fixture, channel, or cable can be electrically quantified in terms of S-parameters using Teledyne LeCroy s SPARQ or another type of network Serial data signal probed at the transmitter output shows acceptable response Losses in the serial data channel affect the signal integrity. This effect can be de-embedded or emulated analyzer, then their electrical impact can be removed from the measurement result. The measurement result is then unaltered by the test setup, and the ability to further measure, apply math, or post-process this true measurement using additional tools, such as parameters, math functions, jitter tracks, histograms, eye diagrams, etc. is available. Serial Data Channel Response Emulation Most commonly, a design engineer will perform their serial data measurement at the output of the transmitter. However, the engineer may also be interested in referring their measurement to the far side of a particular serial data channel. To accomplish this they could either use a physical channel and make their measurement after the channel or they can use channel emulation to see what their serial data signal would look like if it had been transmitted through the channel. This is particularly useful for some compliance testing. The receiver usually applies equalization to open the eye. This equalization can be modeled to show how the signal appears to the receiver after equalization is applied Receiver Equalization Finally, the serial data receiver often incorporates equalization to compensate for losses associated with the serial data channel. Losses from the channel can cause the eye to be completely closed at the input of the receiver. Even though a receiver that utilizes equalization would be able to properly decode this signal, the oscilloscope jitter analysis software will not be able to recover a clock from the signal and will not be able to perform any jitter analysis. For this reason, the oscilloscope emulates the different equalizers the engineer s receiver could be using and thus provides the ability to view the eye diagram and jitter performance on the signal as it is actually seen by the specific receiver. Learn More teledynelecroy.com/dl/1023 teledynelecroy.com/vid/m0t6wec0jyq teledynelecroy.com/dl/1216 teledynelecroy.com/dl/1136 5

TRANSMITTER EMPHASIS EMULATION 1 After Before 2 3 1. Teledyne LeCroy s Eye Doctor II Advanced Signal Integrity Tools provide the ability to impose the effects of a channel or an equalizer on a measured signal. Eye Doctor II allows the subtraction of fixture effects, and the emulation of emphasis, serial data channels, and receiver DFE, FFE, and CTLE equalization effects and integrates seamlessly into Teledyne LeCroy s SDA II software for eye diagram and jitter analysis. 4 2. Notice that the Signal Input is set to Channel 2 minus Channel 3 and the Nominal Bit Rate is set to 5 Gb/s. 3. As you can see this eye diagram contains de-emphasis. This de-emphasis can be removed from the signal so that the eye diagram can be observed without the de-emphasis. 5 4. The pre- or de-emphasis can either be added or removed. In this case, it is set to remove 3.5 db of de-emphasis. 5. The eye diagram is calculated and displayed with the de-emphasis removed. 6

FIXTURE DE-EMBEDDING 6 After Before 7 6. Fixtures and the attached cables can be de-embedded to see what the eye would actually look like directly at the transmitter output. The Emulate/De-embed menu has three choices. 8 9 7. Here Emulate Channel/de-embed Fixture has been chosen. 8. The S-parameter file that contains the fixture response information is an industry-standard Touchstone file format. Simply browse for the file and select the appropriate file for the fixture you are using. The user must first measure or simulate the lossy fixture and then copy it to the oscilloscope. 9. Clicking Apply will now de-embed the fixture. The previous eye diagram shown on page 6 now shows the result with the fixture and cables de-embedded. 7

CHANNEL RESPONSE EMULATION 10 After Before 11 10. In addition to cable and fixture de-embedding, serial data channels may also be emulated. Again, the S-parameter file defining the channel is selected and applied. If the ports in the S-parameter file are different from those shown, the ports used can be reassigned via the dialog. The user must first measure or simulate the lossy channel and then copy it to the oscilloscope. 12 11. The View Response feature allows the user to view a plot of any of the s-parameters in the Touchstone file being used, and allows verification of correct setup. In this case, S21 and Magnitude are selected to show the insertion loss. 8 13 The previous eye diagram shown on page 7 now includes the effects of an emulated serial data channel. 12. The Emulate/De-embed menu shows the setup as defined, with the S-parameter file names used conveniently displayed in the user interface, at the bottom. 13. Notice how the Eye diagram begins to close and the ISI increases when the channel is emulated. This provides insight into how a serial data channel that is not present in the test circuit will affect the serial data signal. Additional Teledyne LeCroy tools, such as masks or IsoBER, can be applied on this eye diagram.

RECEIVER EQUALIZATION 14 After Before 15 14. Receiver Equalization can allow insight into how the receiver will correct for a closed eye situation. In this example, a receiver that employs FFE equalization is simulated. The number of taps is set to five and the number of precursor taps is set to three. Levels are automatically found by the software. 15. With equalization applied, the eye opening widens from that shown on page 8. 16 16. The main Eye Doctor II user interface displays all of the processing steps that are currently being performed directly under each processing block. The Teledyne LeCroy Eye Doctor II Advanced Signal Integrity Tools add precision to your signal integrity measurements, re-capture design margin lost to test fixtures and cables, allow you to support PCI Express 3.0, SATA 6 Gb/s, SuperSpeed USB and 6 Gb/s SAS. When used with Teledyne LeCroy s SDA II software, Eye Doctor II provides fast eye diagram and jitter measurement analysis results using the de-embedded and emulated data on full record lengths. 9

MOST ADVANCED EQUALIZATION Eye Doctor II has advanced equalization capability that allows the user to perform Continuous Time Linear Equalization (CTLE), Feed Forward Equalization (FFE) and/or Decision Feedback Equalization (DFE) on their data signal. Additionally, the data signal after the CTLE or FFE blocks can be used for clock recovery. As seen in the image above, a simple user interface gives the user access to all three of these equalization methodologies. Each equalization type (CTLE, FFE and DFE) can be separately enabled or disabled, and each has a caption showing its current state. Clicking on the CTLE, FFE, DFE or Clock Recovery boxes brings the user to the configuration page for that selection. The Data Path to DFE In selection can be set to From Eq Input, From CTLE or From FFE. Making one of these selections updates the user interface showing the correct connection between the data signal and the DFE input. These different configurations make it possible to have the independent equalization of the data signal and the signal that is used for clock recovery. This ability is very important for serial data standards such as 6 Gb/s SAS. These signals could have closed eye diagrams in which some form of equalization must be performed on the data prior to recovering the clock signal. However, the standard also requires that Decision Feedback Equalization be the only form of equalization used on the data signal. Eye Doctor II makes this possible. Additionally the Feed Forward Equalizer and the Decision Feedback Equalizer have the ability to automatically train to find the optimal tap values. User defined tap values can also be entered. Eye Doctor II contains two separate waveform outputs: EyeDrOut and EyeDrClk. These signals can be used as inputs to SDA II for Eye Diagram and Jitter analysis on the equalized data and clock signals. 10

SPARQ SIGNAL INTEGRITY NETWORK ANALYZER The SPARQ signal integrity network analyzers connect directly to the device under test (DUT) and to PC-based software through a single USB connection for quick, multi-port S-parameter measurements. SPARQ is the ideal instrument for characterizing multi-port devices common in signal integrity applications at a fraction of the cost of traditional methods. It is ideal for: Development of measurementbased simulation models Design validation Compliance testing High-performance TDR PCB testing Portable measurement requirements High-bandwidth, Multi-port S-parameters for the Masses S-parameter measurements are most often produced by the vector network analyzer (VNA), a difficult instrument that is beyond many budgets. SPARQ is very affordable and simplifies measurements, making S-parameters accessible to all. PC-based, Small and Portable Traditional instruments that produce S-parameters are large and fundamentally stationary. The SPARQ, in contrast, is small and weighs less than 20 lbs. It connects to any standard PC through a USB 2.0 interface, allowing SPARQ to run where computing power is easily upgraded. S-parameters, Quick VNA measurements begin with the unpleasant and complex task of calibration. This involves multiple connections that can produce misleading results due to operator error. The SPARQ provides calibrated measurements with a single connection to the DUT and offers simple setup choices. Start and complete the entire measurement with a single button press. Internal Calibration SPARQ takes a revolutionary approach to calibration by building in calibration standards. This enables measurements to be made without multiple connection steps and removes the need for additional electronic calibration (ECAL) modules. Calibration proceeds quickly without user intervention, so one can calibrate often without resorting to the use of out-of-date saved calibrations. Eye Doctor II s Advanced Capabilities Through the use of Eye Doctor II s advanced capabilities the user can flexibly arrange components to allow any combination of de-embedding or emulation for Virtual Probing of any point in the test circuit not otherwise accessible; increase measurement accuracy through the use of a more 3 1 5 2 4 1. Virtual Probe 2. Difference 3. Interpolate 4. Tapped Delay Line Filter 5. Equalized Receiver advanced transmitter and receiver simulate cross-talk with more than one termination model that incorporates channel; specify multiple outputs and customer-specific characteristics; much more. 11

SPECIFICATIONS AND ORDERING INFORMATION Specifications Feature or Capability Cable De-embedding Fixture De-embedding Channel De-embedding Emphasis Emulation Channel Emulation Receiver Equalizer Emulation Record Length Single-ended S-parameters Mixed mode S-parameters Non-ideal Termination Models* Eye Doctor II DFE, FFE, CTLE Up to 512 Mpts * Advanced Mode capability. Ordering Information Product Description Eye Doctor II Advanced Signal Integrity Tools for LabMaster 10 Zi Oscilloscopes Eye Doctor II Advanced Signal Integrity Tools for LabMaster 9 Zi-A Oscilloscopes Eye Doctor II Advanced Signal Integrity Tools for WaveMaster 8 Zi/Zi-A Oscilloscopes, SDA 8 Zi/Zi-A Serial Data Analyzers, and DDA 8 Zi/Zi-A Disk Drive Analyzers Eye Doctor II Advanced Signal Integrity Tools for WavePro 7 Zi Oscilloscopes, SDA 7 Zi Serial Data Analyzers, and DDA 7 Zi Disk Drive Analyzers Eye Doctor II Advanced Signal Integrity Tools for WaveRunner 6 Zi Oscilloscopes Product Code LM10Zi-EYEDRII* LM9Zi-EYEDRII* WM8Zi-EYEDRII* WPZi-EYEDRII* WR6Zi-EYEDRII** Customer Service Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes: No charge for return shipping Long-term 7-year support Upgrade to latest software at no charge *SDAIII software is required for eye diagram and jitter analysis. **SDA II software is required for eye diagram and jitter analysis. 1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. 2009 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. EyeDoctorIIDS-01nov13