S-series Mass Connection Solutions



Similar documents
S-series SQ Controller

DeltaV S-series Traditional I/O

S-series DeviceNet Interface Card

S-series DC to DC Power Supply

DeltaV SISnet Repeater

S-series Electronic Marshalling

M-series FOUNDATION Fieldbus I/O

M-series MD Plus Controller

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

M-series Virtual I/O Module 2

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/62 Process Variable Monitor

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

1756 ControlLogix Chassis Specifications

Power Supplies 3. SDN-P DIN Rail Series

Redundancy Module QUINT-DIODE/40

How To Protect Your Deltav Controllers From Cyber Attacks

Emerson Smart Firewall

Safety technique. Emergency stop module BO 5988 safemaster

3500/25 Enhanced Keyphasor*Module

RM4TG20 three-phase network control relay RM4-T - range V

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

TrueAlarm Fire Alarm Systems

Electronic Control Devices The European Product Catalogue 2007

Rosemount 752 FOUNDATION fieldbus Remote Indicator

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Foxboro Evo Process Automation System

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital input modules

Inductive sensor NI10-M18-Y1X-H1141

3500/40M Proximitor* Monitor

Phase Modular Finally the benefits of Modular ups are for all

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DeltaV SIS for Burner Management Systems

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Quick Connect. quick - simple - efficient.

3DLevelScanner II TECHNICAL DATA SHEET

3500/22M Transient Data Interface

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Three-phase monitoring relay CM-PFE

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

1756 ControlLogix I/O Specifications

How To Use The Vacon 0 Machinery

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

MINI MCR-SL-R-UI(-SP)

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

Modular I/O System Analog and Digital Interface Modules

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

CompactLogix Power Supplies Specifications

PHOENIX CONTACT Features

Unidirectional Transmitter/ Receiver Units Introduction

Micro Motion 3098 Gas Specific Gravity Meter

Technical Information RIA14

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Telephone- and leased line modem for industrial applications TD-36

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Duct Humidity Transmitter

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

ROC800-Series Advanced Pulse Module

PROFIBUS Links & Coupler

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

3500/93 System Display

RACKS CLASSIC G4 SPEC. DATA SHEET page 1/5. Description. Features

Flow switches Series AD/VH

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Plug and Socket Devices CES 63 A Series 8579

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Technical Data. Dimensions

Technical Data. Dimensions

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

DeltaV Control Network Hardware

Operating Instructions

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

E-STOP relays, safety gate monitors

Floodlight Range Installation Guide

Transcription:

DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination footprint Significant labor and work reduction Loop disconnect feature for Analog Signals LED s and replaceable Fuses for discrete Signals Termination Fault Detection between discrete traditional I/O Cards and Mass Connection board Signals Introduction The DeltaV S-series Mass Connection Solutions provide fast, easy and reliable connection from field devices to DeltaV simplex and redundant, high density traditional I/O Cards, while providing several wiring options. The modular design of the Mass Connection Boards further helps to lower the overall termination footprint due to flexible mounting capabilities. Ribbon cable connectors will be used to connect the Mass Connection Boards easily to the simplex or redundant, high density traditional I/O Cards, where loop and termination fault diagnostic information are available.

Benefits Fast, easy way to connect terminals. The DeltaV simplex and redundant high density traditional I/O Cards can be easily wired to the Mass Connection Boards within seconds. No tools are necessary to connect the ribbon cables, so you can significantly reduce labor costs by eliminating additional cabinet wiring. Modular design, improves reliability. The modular designed Mass Connection Boards are more reliable than other traditional solution, by splitting the Signals up, to a max of 16 Signals Optimization of space. The DeltaV S-series Mass Connection Solutions offer significant space advantages by integrating all needed cabinet wiring components on one board. Significant labor work reduction. No need for cross wiring between I/O cards and Mass Connection Boards anymore, due to flexible 1:1 ribbon cable based connectivity. Significant cost reduction. Due to the fact that off-the-shelf Ribbon cables can be used inside a Cabinet with a max. Length of 3 m, significant cost reductions can be achieved. In some cases, longer cables are needed for connections between two Cabinets. 6m long Standard Round Ribbon Cables can be ordered to be used with the Mass Connection Solutions. Loop Disconnect Features for all Signal Types. For each Signal Type, a loop disconnect feature is available on the Mass Connection boards. On the AI/AO Mass Connection boards, this is realized using a specific knife edge disconnect setup with 2mm test wholes, in this way maintenance or calibration work can be performed without disturbing the 4-20 ma loop based Signal On the DI/DO Mass Connection boards, this is realized using replaceable fuses. In this way, loop power to the field can be easily disconnected, during maintenance activities. Termination Fault Detection With the DI/DO Mass Connection boards, power or cable failures can now be detected by DeltaV Diagnostic when used with the new Plus Cards. www.emersonprocess.com 2

Product Description AI/AO Mass Connection Board DI Mass Connection Board (for simplex DI Card) The AI/AO Mass Connection Board connects to the new S-series Plus (simplex or redundant) AI, 16 Channel and AO, 16 Channel cards by using either two ribbon cables with 24-Pin connectors or the 48-Pin special Round Ribbon Cable, which is required if the distance is longer than 3m. Up to 16 Analog, 4-20 ma HART based Field devices can be connected to the AI/AO Mass Connection Boards by screw terminals. 2- And 4- wire Devices are supported by the 3- row screw architecture, so you can choose on a Channel by Channel basis. For each Channel, a loop disconnect feature with 2mm test wholes is implemented. In this way, maintenance or calibration work can be performed at any time, without disturbing the 4-20 ma loop based Signal. This DI Mass Connection Solution (set of two boards) connects to the existing simplex S-series DI, 32 Channel, 24 VDC, Dry Contact cards by using either two ribbon cables with 20-Pin connectors or two of the 20-Pin standard Round Ribbon Cable, which is required if the distance is longer than 3m Up to 16, 24 VDC based discrete input Signals can be connected to each of the DI Mass Connection Boards by screw terminals. Dry Contact or 24 VDC Isolated Field Signals are supported by the 2- row screw architecture. Yellow LED s are providing status Indication for each Channel, while the replaceable fuses can be used to disconnect loop power to the field, during maintenance activities. Please refer to the Cross Reference List for your application. Please refer to the Cross Reference List for your application. www.emersonprocess.com 3

DI Plus Mass Connection Board (for DI PlusCard) DO Mass Connection Board The DI Plus Mass Connection Solution (set of two boards) connects to the new redundant S-series Plus DI, 32 Channel, 24 VDC, Dry Contact cards by using either two ribbon cables with 20-Pin connectors or two of the 20-Pin standard Round Ribbon Cable, which is required if the distance is longer than 3m. Up to 16, 24 VDC based discrete input Signals can be connected to each of the DI Plus Mass Connection Boards by screw terminals. Dry Contact or 24 VDC Isolated Field Signals are supported by the 2- row screw architecture. Yellow LED s are providing status Indication for each Channel, while the replaceable fuses can be used to disconnect loop power to the field, during maintenance activities. A Termination Fault Detection feature is built into each of the DI Plus Mass Connection boards which allows the new redundant S-series Plus DI, 32 Channel, 24 VDC, Dry Contact cards to detect power or cable failures on the board. There is a jumper on the board to be able to turn this feature off, in case rewiring needs to be performed while the process is running. The new S-series Plus DI, 32 Channel, 24 VDC, Dry Contact card does have two new parameters in the Explorer view, one for each cable connection. When these Parameters are turned on, DeltaV Diagnostics will mark the status of affected Signals accordantly. The DO Mass Connection Solution (set of four boards) connects to the existing simplex S-series DO, 32 Channel, 24 VDC, High-Side cards as well to the new redundant S-series Plus DO, 32 Channel, 24 VDC, High-Side cards by using either two ribbon cables with 20-Pin connectors or two of the 20-Pin standard Round Ribbon Cable, which is required if the distance is longer than 3m. Two DO Mass Connection boards need to be daisy chained to get to 16 Channels, which can be connected back to the card. A short ribbon cable with 20-Pin connectors can be used for that purpose too. Up to 8 Field devices can be connected to each of the DO Mass Connection Boards by screw terminals. Either +24 VDC high-side relay outputs or voltage free relay contacts can be used, pending on the position of the fuse, which can be jumpered for this reason. Yellow LED s are providing status Indication for each Channel, while the replaceable fuses can be used to disconnect loop power to the field, during maintenance activities. A Termination Fault Detection feature is built into each of the DO Plus Mass Connection boards which allow the new redundant S-series Plus DO, 32 Channel, High-Side cards to detect power or cable failures on the board. There is a jumper on the board to be able to turn this feature off, in case rewiring needs to be performed while the process is running. Please refer to the Cross Reference List for your application. www.emersonprocess.com 4

The new S-series Plus DO, 32 Channel, 24 VDC, High- Side card does have two new parameters in the Explorer view, one for each cable connection. When these Parameters are turned on, DeltaV Diagnostics will mark the status of affected Signals accordantly. Please refer to the Cross Reference List for your application. 6m Round Ribbon Cables The 6m long 20 pin - Standard Round Ribbon Cable is recommended to be used with discrete signals for distances longer than 3 m. The 6m long 48 pin - Special Round Ribbon Cable is recommended to be used with analog signals for distances longer than 3 m. www.emersonprocess.com 5

Cross Reference List Description Ordering Information SE40X3S2B11 SE40X5S2B5 SE40X1S2T2B5 SE40X1S2T2B7 SE40X2S1T2B6 SE40X2S1T2B8 Set consists of AI Mass Connection Solution ü 1 item AO Mass Connection Solution ü 1 item 48-pin Round Ribbon Cable 6m SE4000L6P48 ü ü 1 item DI Mass Connection Solution ü 2 items DI Plus Mass Connection Solution ü 2 items DO Mass Connection Solution ü ü 4 items 20-pin Round Ribbon Cable 6m SE4000L6P20 ü ü ü ü 2 items If the X gets replaced by a : 0 = your order will contain a simplex Card without a Mass Connection Solution* 3 = your order will contain a redundant Card set without a Mass Connection Solution* 5 = your order will contain a simplex Card with the correct Mass Connection Solution* 8 = your order will contain a redundant Card set with the correct Mass Connection Solution* *if applicable www.emersonprocess.com 6

Hardware Specifications Common Environmental Specifications for Mass Connection Boards Category Operating temperature -20 to +60 C Specifications Storage temperature -40 to 85 C Relative humidity Airborne Contaminates 5 to 95% Non-Condensing ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating Protection rating IP 20 Shock Vibration 10g, 1/2 sine wave for 11 milliseconds 1mm Peak-to-Peak from 2 to 13.2 Hz, 0.7g from 13.2 to 150 Hz Specifications for AI/AO Mass Connection Boards Channel Type Category 4-20mA HART Specifications Number of Channels 16 Dimensions Depth: 109.78 mm; Height: 60.52 mm; Width: 118.06 mm Specifications for DI Mass Connection Boards Channel Type Category 24 VDC Dry Contact, or 24 VDC Isolated Specifications Number of Channels 16 Isolation Detection Level for ON Detection Level for OFF Source Impedance Source Voltage Field circuit power per board Dimensions The field wiring connections are optically isolated from the DI Card circuits and factory tested to 1000 VDC for 2s. No Channel-to-Channel isolation. > 2 ma @ 24 VDC < 0.25 ma @ 24 VDC 5 KΩ +24 VDC Input Power, recommend external fuse at power source. +24VDC +/- 10% @ 75mA typical,100ma maximum Depth: 110.05 mm; Height: 44.1 mm; Width: 102.82 mm www.emersonprocess.com 7

Specifications for DO Mass Connection Boards Channel Type Category Output Channel Options and Ratings Isolation Relay Max. switching current Optional Power for +24 VDC High Side Outputs Dimensions Isolated Relay Contact or 24 VDC High Side Specifications Isolated Relay Contacts - 250 VAC/24 VDC maximum@ 5 Amps maximum per channel +24 VDC High Side @ 5 Amps maximum per channel, 10 Amps maximum per board Isolated Relay Contacts Isolated at 250 VAC and factory tested to 3600 VDC (channel-to-system and channel-to-channel) +24 VDC High Side Isolated at 250 VAC and factory tested to 3600 VDC (channel-to-system). No channel-to-channel isolation 5A for 30 VDC; 5A for 250 VAC +24VDC +/- 10% @ 10 Amps maximum Depth: 109.75 mm; Height: 60.52 mm; Width: 133.3 mm Common Environmental / Specifications for Round Ribbon Cables Category Operating temperature -20 to +60 C Specifications Storage temperature -20 to 70 C Relative humidity Airborne Contaminates 5 to 95% Non-Condensing ISA-S71.04-1985 Airborne Contaminants Class G3 Conformal coating Protection rating IP 20 Available Cable lengths 6 m Wires/Pairs per Cable 50/25 or 20/10 Wire Gauge 0.14 mm 2 / 26 AWG www.emersonprocess.com 8

Certifications The following certifications are available for S-series Mass Connection Solutions: CE: - EMC- EN 61326-3-1:2006 -LVD: Directive 2006/95/EC Aug 2007 FM: - FM 3600, Dec. 2011 - FM 3611, Dec. 2004 - FM 3810, Jan 2005 - ANSI/ISA 60079-0, Oct 2009 - ANSI/ISA 60079-15, Jul 2009 CSA: - CSA C22.2 No. 213-M1987, 1987 (Reaffirmed 2008) - CSA C22.2 No. 61010-1, 2004 (Reaffirmed 2009) - CAN/CSA-E60079-0, 2007 - CAN/CSA-E60079-15, March 2002 (Reaffirmed 2006) ATEX: - ATEX 94/9/EC - EN60079-0: 2009 - EN60079-15:2005 - EN60079-15:2010 IEC-Ex: - IEC60079-0:2007 - IEC60079-15:2005 - IEC60079-15:2010 www.emersonprocess.com 9

Certifications S-series Mass Connection Solutions will be submitted for the following certifications: Marine Certifications: IACS E10:2006 Rev.5 Control, Protection & Safety; DNV 2.4:2006 - ABS Certificate of Design Assessment - Bureau Veritas Certificate - DNV Marine Certificate - Lloyds Register GOST Hazardous Area certification Zone 2 (Russian) - POCC US.ГБ05.B03564 EAC Hazardous Area certification Zone 2 (Russian, Belarus, Kazakhstan) www.emersonprocess.com 10

Hazardous Area/Location: S-series Mass Connection Solutions can be installed and used based on the following Standards: FM (USA): Installation and Field Circuits: Class I, Division 2, Groups A, B, C, D, T4 cfm (Canada): Installation and Field Circuits: Class I, Division 2, Groups A, B, C, D, T4 ATEX: Installation and Field Circuits: IEC-Ex: Ex na IIC T4 Gc Ex na nc IIC T4 Gc Installation and Field Circuits: Ex na IIC T4 Gc Ex na nc IIC T4 Gc Regarding the Installation instructions please refer to the following Documents: Class 1 Division 2 Installation Instructions DeltaV S-Series Zone 2 Installation Instructions DeltaV S-Series 12P5402 Rev. C 12P5404 Rev. C www.emersonprocess.com 11

Ordering Information Description Model Number AI/AO Mass Connection Solution (one board) * 48-pin Round Ribbon Cable (6m, one Cable) SE4000L6P48 DI Mass Connection Solution (two boards as a set) * DI Plus Mass Connection Board (two boards as a set) * DO Mass Connection Board (two boards as a set) * 20-pin Round Ribbon Cable (6m, two as a set) SE4000L6P20 *S-series Traditional I/O Cards and Mass Connection Solutions can only be ordered in a set right now, please refer to the PDS S-series Traditional I/O to find the correct ordering number for the set. Spare part Ordering Information AI/AO Mass Connection Board DI Mass Connection Board DI Plus Mass Connection Board DO Mass Connection Board Description Model Number KJ4007X1-BD1 KJ4007X1-BA1 KJ4007X1-BB1 KJ4007X1-BC1 DO Mass Connection Board Fuse Main 250 VAC/10 A, pack of 10 fuses DO Mass Connection Board Fuse Channel 250 VAC/5 A, pack of 32 fuses RTQ RTQ www.emersonprocess.com 12

S-series Mass Connection Solutions March 2015 Related 3rd Party Products Phoenix Contact Part Number Description Part Number Part Type 20-pin Round Ribbon Cable 0.5m 2296391 FLK 20/EZ-DR/ 50KONFEK 20-pin Round Ribbon Cable 1.0m 2296401 FLK 20/EZ-DR/ 100KONFEK 20-pin Round Ribbon Cable 1.5m 2296472 FLK 20/EZ-DR/ 150KONFEK 20-pin Round Ribbon Cable 2.0m 2296485 FLK 20/EZ-DR/ 200KONFEK 20-pin Round Ribbon Cable 3.0m 2296498 FLK 20/EZ-DR/ 300KONFEK 20-pin Round Ribbon Cable 4.0m 2296508 FLK 20/EZ-DR/ 400KONFEK 20-pin Round Ribbon Cable 8.0m 2296524 FLK 20/EZ-DR/ 800KONFEK 20-pin Round Ribbon Cable 10.0m 2296537 FLK 20/EZ-DR/1000KONFEK 48-pin Round Ribbon Cable xm -- CABLE-50/2FLK24/2FLK24/ xm/s Other Termination products available from Phoenix Contact, can be found under http://www.phoenixcontact.net/microsites/emerson/ Termination%20Boards%20DI.htm Emerson Process Management Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 www.emersonprocess.com/deltav 2015, Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. DeltaV is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.