Data Cables. European Edition



Similar documents
Communication, Signal & Data Cables

Specification SFTP CAT6 Network Cable 23AWG CU

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

Coaxial Cables. for Broadband Communication Networks. European Edition

Coaxial Cable Solutions Guide

Copper Cabling Infrastructure Offering

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

ETHERLINE Ethernet Cable, Connectors & Tools

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

Gulf Cable & Electrical Ind. Co.

Uniprise Solutions COAX 101. White Paper.

Network Engineers Everywhere:

Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

TECHNICAL SPECIFICATION

COAX Cables Radio Frequency Cables

Commercial Coaxial Cable

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

CAVEL VS80205 MADE IN ITALY 1000 V

Sound, Alarm & Security Cable 7

Serial Data Grade Cables

Outside Telephone Cable

West Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE

Cable 101: Introduction to Belden Wire & Cable Company

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Standard Buccaneer - Ethernet

APR 2016 Rev M

E Series. E Series. Category 6 and 5e. Features

Copper Cables CONNECTIVITY & CABLING SYSTEM

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Flexible and safe solutions, for decades. Cables for alarmand safety systems

with Component Rating A Simple Perspective

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

CCTV System Troubleshooting Guide

Coaxial Cables for Medium-Frequency Applications

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Coaxial Cable 5. Electronics

MICROCABLES. A complete vision of your connectivity needs. Catalogue

LS Data Communication Product

75 Ω Transmission System

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

Broadcast and Commercial AV Cabling MASTER CATALOG

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

ULTIMATE SNAP-N-SEAL

Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Security & Control Cables

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof

Total Solutions Verification

WIRE & CABLE PRODUCTS

Instrumentation Cable Power Cable Assembly Solutions...32

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

6000 Series Buccaneer

HARTING Ethernet Cabling 8-poles Overview

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

les ab C eration en G ew N

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Precision Video Cable for Analog and Digital Overview

RF & Microwave cable assemblies C291

A5-N/3GT30G-FLEX3-75 Conector Hembra, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Category 6 UTP - Cabling System

Communication and Control Cable Fire Alarm Cable Coaxial Cable ( CAT V / M ATV & CCTV Cables)

Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Accelerating Light. Copper Cabling Solutions. Category 6A

IT Cabling Solutions

Data Communications Competence Center

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Industrial Ethernet The Perfect Cable for an Imperfect Environment

How to Choose the Right Cable Category

Flexible Control Cables

Standards Affecting a Premise T-1 Installation

C 060 CCTV Coaxial Cable

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

Network Design. Yiannos Mylonas

Panduit 28 AWG Patch Cords Installation Guideline

Product Bulletin. One Enterprise. One Infrastructure. One Partner. Shielded Cabling Systems

Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

RGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

Copper Patch Cords. Impact On Network Performance and Reliability

with coloured cores and overall copper screen UL/CSA... 17

HARTING Ethernet Cabling 4-poles Overview

coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable

Terminating 25-Pair Cable and 4-Pair Cross Connects

RF cables. Edition 2015

CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation.

CommScope-SYSTIMAX Solutions UTP Cable Berk-Tek UTP STP and F/UTP Cable Solutions Blanks and Dust Covers 2.

Transcription:

Data Cables European Edition

Belden Data Cables Reliable Performance through Innovation Table of Contents Reliable Performance through Innovation Belden Quality Cable Finder Unshielded cables UTP Category 5E UTP Category Shielded cables (S)FTP Category 5E (S)FTP Category ISTP Category 7 Ordering Information & DataTwist Colour Code Table Page 1 2 3 4 5 7 Reliability, performance Over the years, Belden has become an international byword for premium quality and reliability, an accolade for excellence earned through decades of dedication to meeting the highest industry standards. Our strategic objective is to provide our customers with superior solutions for their present and future wire and cable needs. Accordingly, every solution we devise is based on performance, innovation and reliability the three cornerstones of Belden s business strategy. A long history of innovation For the past years, Belden has been an acknowledged front-runner in the wire and cable industry, developing novel technologies and processes for the manufacture of innovative wire and cable products. Products that keep our customers at the forefront of new developments in their chosen field. Starting in 1902, when the company was founded in Chicago, Belden has consistently pioneered breakthrough technologies and set new industry standards. This trend was set with early successes like Beldenamel insulation (1905) and the introduction of the soft rubber plug in 19. Ever since, Belden has been an industry innovator, conceiving and developing special applications in cabling, shielding and jacketing. All focused on customer needs. All clearly establishing Belden s leadership in wire and cable technology. Belden s commitment to innovation has historically fuelled new growth for industry players. It has also earned Belden global innovation leadership that is constantly driven by the Belden Engineering Centres. For instance with Duobond, Flamarrest, French Braid, MediaTwist and DataTwist 0e. Another yardstick for measuring the success of our novel products are the many patents we hold. But the ultimate criterion is the fitness for use of the products we supply to our customers. Global player The company s successful growth strategy in the 1990s led in 1999 to the purchase of Cable Systems International, the largest specialty telecom cable facility in the world. Other capabilities were created by acquisitions in Hungary, United Kingdom, the USA and the Netherlands, where Belden has its European headquarters and a large R&D Centre and manufacturing facility. Apart from Europe and the US, Belden s worldwide presence includes marketing and sales organizations in Asia Pacific, Latin America and the Middle East. Today, Belden is a global player in the wire and cable industry, designing, manufacturing and marketing specialty cable, such as copper, and optical fibre cable for electrical, electronic and communications equipment. Reliable products that help Belden s customers keep pace with the shifting dynamics of these fast-moving markets. 1

Reliable Performance through Innovation European manufacturing operations As Belden s global business plans call for a commitment to local markets world-wide and a thorough understanding of local dynamics, Belden has established a very significant presence in core European markets. This ensures that appropriate solutions can always be found to meet the cable and wire needs of our European customers. NYNÄSHAMN MOSCOW Belden has the largest range of cable products in all the markets we serve. Dedicated products matched to local needs. These include over.000 products for computer networking and computer equipment; for telecommunications and industrial instrumentation and control; for broadcasting and entertainment; and for cable television and electrical equipment. MANCHESTER VENLO With European sales accounting for almost a quarter of Belden s world-wide turnover, Belden has clearly demonstrated the success of its Think global, act local approach. And with its 0-strong workforce across Europe and sales offices from Moscow to Lyon and from Stockholm to Dubai Belden has a strong local capability to understand customers problems and to provide the answer. LYON VILLINGEN- SCHWENNINGEN MILANO BUDAPEST Belden s European headquarters and manufacturing base is in the Netherlands, where the company also has its European Engineering Centre. Detailed brochures Full-colour brochures are available on the extensive range of Belden products: Digital telephony cables Shielded and non-shielded cables Multi-conductor cables Optical fibre cables Audio/ video cables Coaxial broadband cables Electrical cables To request detailed brochures and datasheets on our product lines and the extensive Belden Master Catalog, please contact your local Belden representative or send an e-mail to sales.info@belden-europe.com Manufacturing Facilities Addressing environmental issues correctly is recognized as a high priority, particularly in the industrialized world and not least at Belden. Accordingly, the company makes every effort to minimize the environmental impact of its operations and products. Recognizing ecological concerns shared by customers and consumers world-wide, from 1999-1 a working group at Belden s European headquarters in Venlo completed Distribution Centers Sales Offices ISO 1 EMS Environmental Management System comprehensive preparations for ISO 1 EMS certification. This environmental management and audit system was implemented and certified in 1. The progress achieved in the practical implementation of Belden s environmental objectives will be published each year. This will include the measures taken by the company to minimize the environmental impact of Belden s operations, also in respect of (energy) savings in production and novel materials and processes. USA United Kingdom The Netherlands Table of Contents 2

Belden Data Cables Belden Quality The Belden approach to cable quality Belden s commitment to quality begins even before its products leave the product development phase. Not only does Belden design products to achieve a given level of performance, it also ensures that these products can be manufactured in a way that makes that performance possible and consistent. The keyword in the Belden approach is prevention. Prevention involves the use of key parameters of product performance and statistical methods to monitor the process and identify changes that affect the quality of the product and adjust the process accordingly. The responsibility for quality moves from the inspectors to the design and manufacturing departments. Product quality at Belden begins long before we ever manufacture a single meter of cable. Here s a look at how we do it: Design for manufacturability Delivering a superior product means being sure you make a superior product, day after day. Design for Manufacturability (DFM) seeks to identify and account for the challenges inherent in any manufacturing process and address them up front. It takes into account every aspect of manufacturing: materials, machines, operations, environmental factors, and more. The purpose of DFM is to design products that are robust enough to stand up to the challenges of manufacturing to yield consistent, superior product quality. DFM is focused on the entire manufacturing process and how it can be monitored, controlled, and adjusted to achieve our quality goals. The benefit to Belden customers is that our products achieve high performance standards that are both consistent and measurable. Monitoring & maintaining quality Before releasing any new products for production, all critical characteristics, such as dimensions, electricals, and physicals are targeted to meet a capability index (Cpk) 1., which corresponds to a 99.997% passing rate. A Cpk is an index that quantifies the capability of a product s design and manufacturing process. It takes the actual performance of a product and compares it to a benchmark level of performance (e.g.: the industry standard). Cpk = Headroom (average worst case margin from spec.) 3 x Standard deviation The Cpk values are determined through capability studies, which represent the final product design and manufacturing set-ups. This includes statistically valid run times, sampling quantities and methods. The result is a Cpk value that corresponds to a predicted defect rate for the product. Based on these statistics ( measuring % is simply not possible) 99.997% of the Belden products will pass the applicable cable standards. If Belden specifies headroom above a cable standard this will always means in addition to the Cpk = 1. range (4 ). Variation of a product characteristics that performs just within our specification. Lower Spec. 4 3 = 1.0 Avg: 4.0 db +3 +4 99.7% of Product 3 = 1.0 Cpk 99.997% of Product 4 = 1. Cpk = Design Goal 5 0 5 15 1.0 db 7.0 db Test lab Belden Engineering Centre Belden s Cpk testing methods are actually more reliable than simple pass/ fail testing on cable as it comes off the manufacturing line. Rather than merely testing batches of cable, Cpk testing allows Belden to monitor and control the long-term quality and performance of the cable we produce. Cpk s are tracked constantly through Plant Quality Assurance, using in-house developed Quality Data Acquisition Systems. The generated Cpk values give us an accurate measurement of quality over time, and are used to drive continuous quality improvements. It enables us to adjust our manufacturing processes in ways that ensure the production of high performance cable, day in day out. 3 Table of Contents

Belden Quality Bonded pairs Installed performance is the performance of a channel in real world installation conditions. Common real world conditions include the use of cable that have experienced severe flexing when pulled around bends and corners and cable coiled into service loops and/ or stuffed into outlet boxes. The Belden Bonded Pair cables provide better installable performance, due to its unique, patented design. Better by design For a twisted pair cable, a solid design begins with the individual conductors and their relationship to one another forming a pair. An ideal pair is comprised of two perfectly balanced insulated conductors that are mirror images of each other. The copper used in the two conductors is identical with exactly the same dimensions and is also perfectly centered, or concentric, within each insulated conductor. The ideal twisted pair, with perfect centricity and concentricity. Design dictates performance Belden Bonded Pair cables are designed to maintain their outstanding performance after installation. To demonstrate this, an Installation Stress Test has been designed and implemented. To simulate pulling the cable through and around cable trays, ceilings and walls, each cable was run through a series of controlled bends and twists. Next, the end of the cable was placed into an outlet box, and a 3 meter length of the cable was loosely coiled into a service loop at the workstations end. The cables were tested before and after the test to identify any changes in performance. If we compare the RL values of the Cat5E Belden Bonded Pair cable vs. an industry leading Cat5E cable we find that the Unbonded Pair cable s RL value degraded by more than db, or more than 15 times their before-installation values. Belden s Bonded Pair cables exhibited little change in RL performance. (For more detailed information, please refer to Belden Technical Bulletin TB-, The Impact of Typical Installation Stresses on cable Performance.) Industry 0 MHz Cat 5e Cable Return Loss Margins ( MHz) Centricity Margin (db) Higher is better Spec. Limit Fail Initial Installed Centricity Belden DataTwist 0 Cat 5e Return Loss Margins ( MHz) To maintain this perfect balance, the center-to-center distance, or centricity, between the copper conductors must remain fixed and should never vary not even in the slightest! In balanced signal transmission on an ideal pair, these concentricity and centricity factors help ensure that the signal does not radiate or bleed off the pair and that the pair cancels out all incoming noise. When the conductors of a twisted pair become separated, impedance mismatches, Return Loss (RL), and crosstalk problems arise. In order to prevent this separation from occurring and to provide structural stability, Belden has developed its patented Bonded Pair technology. As the picture illustrates, even when a Bonded Pair cable is bent, its conductor-to-conductor spacing remains stable. Margin (db) Initial Installed Data Pairs Blue Orange Green Brown Higher is better Spec. Limit Only a Bonded Pair will not gap when the pair is bent around a corner. Unbonded Pair Bonded Pair Performance reduces costs To further document the after-installation performance of both Bonded Pair and Unbonded Pair cables, Belden surveyed a large number of contractors regarding their installation experiences. This survey showed a clear difference between the two cable types after installation was complete and field testing was conducted to verify compliance with industry standards, both proposed Category and Category 5E. It showed that the Belden Bonded Pair cables cause significantly less test failures compared to Unbonded Pair cables. In fact, with Bonded Pair cables time savings of up to 1.5 minutes per drop (Cat 5E) and 2.5 minutes per drop (Cat ) can be expected because far less troubleshooting and re-work is required. (For more detailed information, please refer to Belden Technical Bulletin TB-7, Contractor Field-Testing Survey Reveals Performance- Related Cost savings Using Bonded Pair Cables.) Table of Contents 4

Belden Data Cables Cable Finder Origin Industry standards Belden part number US product Europe product Description Tested to frequency (MHz) Remarks EN 1-1 TIA/EIA -B2 ISO/IEC 01 2nd ed. Page Unshielded Cables UTP Category 5E E ENH 17E 17ENH A ANH E ENH 1592A 1592ANH 17A 17ANH Twin E Twin ENH DataTwist 0 DataTwist 0 Twin E Twin ENH DataTwist Patch DataTwist Patch DataTwist 0 Patch DataTwist 0 Patch 0 0 0 0 0 0 0 0,,, 7 7 7 7 UTP Category 79E 79ENH E ENH 1A 1ANH 1GB A NH MediaTwist MediaTwist MediaTwist Patch DataTwist 0e DataTwist 0e 2 2 2 2 0 0 0 0 0,,, 9 9 9 Shielded Cables (S)FTP Category 5E 1E 1ENH 1E 1ENH A ANH 1E+ 1ENH+ 1E+ 1ENH+ 1E 1ENH Twin 1E Twin 1ENH Braided 1E Braided 1ENH Twin 1E+ Twin 1ENH+ Patch Patch, (S)FTP Category E ENH E+ ENH+ Braided E Braided ENH 2 2 2 2,, ISTP Category 7 15ENH 17ENH Twin 15ENH 0 0 Notes: Plenum versions and various multipair cables available upon request. Please check for available outdoor cables. All specification limits according to ISO/IEC 01 2nd. Edition (September 2), unless otherwise stated. All values at frequencies below 4 MHz in this brochure are for reference only, in accordance with ISO/IEC 01. Typical values represent values from multiple tests of our products. These numbers are not guaranteed but are designed to give the user an idea of the products capabilities. The minimum/maximum values are guaranteed values. For ordering information see page. 5 Table of Contents

UTP Category 5E Belden E Belden ENH Belden 17E Belden 17ENH Halogen-free version Twin version of E Twin version of ENH Cat. 5E Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA - B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) 1 4 1..5 2.1 3.2.2 9 4.0 3.9 59.3.3 5.7 5. 59.1.1.5.3.2.0.0.0 7.9.2.2 9.0.9...1 9.9.2.2.4.2.5 2.5 1.5 1.0..3 19. 2.0.0 Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.90 Nominal overall diameter (mm): 5.0 Impedance (Ohm): Ohm ± 15 % Single Twin E 2 ENH 0 1 U 0 ft. U 5 m.5 kg 0 ft. 5 m.5 kg 1 ft. 0 m.0 kg 0 ft. 0 m 2.0 kg Belden A DataTwist 0 Bonded pairs Cat. 5E Belden ANH Belden A Belden ANH Halogen-free version Twin version of A Twin version of ANH Product description Unshielded Twisted Pair Cable, 4 x AWG, ripcord. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Flame test: UL CM UL ISDI Vertical Tray, CSA FT1 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) 1 4 1..5 1 2.1 3.2.2 9 4.0 3.9 59.3.3.3.2.0.0.0 7.9.2.2 9.0.9...4.2.5 2.5 1.5 1.0..3 19. 2.0.0 15 2.5 0.9 19 0.5 1 Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.95 Nominal overall diameter (mm): 5.0 Impedance (Ohm): Ohm ± 15 % Single Twin A 5 0 ANH 59 U 0 ft. U 5 m.5 kg 0 ft. 5 m.5 kg 1 ft. 0 m.0 kg 0 ft. 0 m 2.0 kg Table of Contents

Belden Data Cables UTP Category 5E Belden 1592 A DataTwist Patch Cat. 5E Belden 1592 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded bare copper conductors, polyolefine insulated singles, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT1 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Orange, Violet, White, Black Velocity of propagation (%): 9 Typ. DCR (Ohm/ m): 7.9 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): 0.99 1 2.5.3. 9 59. 4 4.9 4.1.3 3.7.4 59 2 7...3..5 1 9.9.4.3.7.4.1 9.3..7.7.5.5.3. 2. Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± %..1..9.9..5.4 1.7.4. 15.0 2 2.4.4.3. 5.9 2 1.7 2.9.5 15..9.7. 15.0 15.0 2 2.7 0.3.5 U 0 ft. U 5 m 9.5 kg 0 ft. 5 m 9.5 kg Belden 17 A DataTwist 0 Bonded pairs Patch Cat. 5E Belden 17 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded tinned copper conductors, polyolefine insulated singles with, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT1 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Orange, Violet, White, Black Velocity of propagation (%): Typ. DCR (Ohm/ m):. Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): 0.99 1 2.4.3 7 9..9 4 4. 3.9.3.7.5 7.7.2.3 3. 3. 1 9. 7.9.3.7.5.0 9.0..7..4.2.3..0 Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± %..9.0.9.9.0.5 15.9.4. 1.2 2.1.7.3. 9.3 1.3 2.2.5 2 19.4.. 15.0 19.0 2.7..3 7 1.0* * 0.2.3.2 17.0 U 0 ft. U 5 m.3 kg 0 ft. 5 m.3 kg * values at 0 MHz 7 Table of Contents

UTP Category Belden 79E Cat. Belden 79ENH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) 1 4 1..5 1 2.1 1.7 7 74.2 74.2 3. 3.5 3.4 59.4.0 5..3.3 7. 7.1...5.0 3.3.3 9. 9.0 59...7.1.1.1 15.5.4.9.9 19.9 1..4.4.3 17.1.1.1.0 19.. 19 1.0 2.0.7 17.3 3.3 17.3 Typical velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.01 Nominal overall diameter (mm):.2 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 1 ft. 0 m kg 0 ft. 0 m.0 kg Belden E Bonded pairs Cat. Belden ENH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) 1 4 1..5 1 2.1 1. 0.2.2 7 3. 3.5 7 3 74.4 59.4.0 5.7.3.3 7. 7.3 7...5.2.3.3 9. 9.3...7.4 3.1.1 15.5 15.1.9.9 19.9 1.1.4.4.3 17.1.1.1.5 19.. 1.0 2.0. 17.3 3.3 17.3 Typical velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.5 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 5 ENH 5 U 0 ft. U 5 m.1 kg 1 ft. 0 m kg 0 ft. 0 m.0 kg Table of Contents

Belden Data Cables UTP Category Belden 1 A MediaTwist Bonded pairs Cat. Belden 1 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulated singles with, ripcord, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL type CMR, CMG, CM, UL 1 riser, UL Vertical Tray, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) max. (TIA /EIA Cat. ) Standard colour: Grey, Gold, Brown, Blue, Red, Green, Yellow, Orange, Violet Velocity of propagation (%): Typ. DCR (Ohm/ m): 7.4 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): 0.9 1 2.0 1.7.3. 2.3 4 4 3. 3.4 3.3 7. 59.5.0 5.5.3..3 1 7. 7.0.2 9.7.7.5 7.9...3 9.5..3.. 59 Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % MHz: ± 15 % 0 MHz: ± % 0 0 MHz: ± %..7.0.9.9.2.5 15.4.1.4 2.9.0 19. 1.5.3..5.0 1.2.3.4.0.3.0.0....0 0.1.0.9 1.0 0..5.1 17.0 ft. m 4.3 kg A 0 ft. A 5 m.2 kg Belden 1GB MediaTwist Bonded pairs Patch Cat. Belden 1GBNH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded tinned copper conductors, polyolefine insulated singles with, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Violet, White, Black Velocity of propagation (%): Typ. DCR (Ohm/ m):.2 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): 0.99 1 2.0 1..3. 2.3 4 4 4.1 3. 3.3 7.7.2.5 5..3.. 1.2 7.4.3 9.7.0 9.3.4..7.5 59.4 9.4.3..9 Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % MHz: ± 15 % 2 MHz: ± % 2 0 MHz: ± %..7.7.9.9.2.5 17.0 15..4 2..4.0..3..3.0 1.4.7.5.9.1.0.0.3. 1.7 4..0 2..1.3 15 1.0 0.1.2.2 1 17.0 0 ft. 5 m.2 kg A 0 ft. A 5 m.2 kg 9 Table of Contents

UTP Category Belden A DataTwist 0e Bonded pairs Cat. Belden NH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulated singles with, e-spline, ripcord, PVC jacket. Applicable industry standards: TIA / EIA -B2 Flame test: UL type CMR, UL1 riser listed, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) max. (TIA /EIA Cat. ) guaranteed max. guaranteed guaranteed guaranteed guaranteed, White Velocity of propagation (%): 7 Max. DCR (Ohm/ m):.2 Nominal capacitance (pf/ft.): 15.5 Diameter of insulated conductor (mm): 1.05 1 2.0.3 0.3...3.4 4 3. 3. 3.3.3.. 59.5 7.7.0 5.7.3.3...3 59. 1 7. 7.2.2.3.7.7.7.1.5.1.....3.7 9.5 9.1.3 59.3....2..7.2.9.9.9.9.2.7 Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % 2 MHz: ± 15 % 2 0 MHz: ± % 0 0 MHz: ± %.5 15.4.7.4.4 2.9.9.0.7 19..3.3...5.4 0 ft. 5 m.2 kg U 0 ft. U 5 m.2 kg A 0 ft. A 5 m.2 kg Colour code: Pair no. 1 Pair no. 2 Pair no. 3 Pair no. 4 1.2.9.4.5.0.0.3..0.5.... 1.3 1.0. 2..2.3.3 1.. 3.5.1 17.3.5 0..7.1.2.9 19.9 4.5 1.3 19. 0.0..3.3. 0. 15.9 19.5 0.9.2... 1. 15.2 1.4 White/Green & Green White/Orange & Orange White/Blue & Blue White/Brown & Brown 0.5.4.. 9.2 15.2.7 17. The DataTwist 0e cable is a revolutionary UTP cable engineered specifically to perform well beyond proposed Category standards. While proposed Category cable is specified only to 2 MHz, DataTwist 0e is the only UTP cable in the industry fully characterized with guaranteed performance to 0 MHz. So users have far more headroom to compensate for unforeseen factors that can inhibit the performance of a cabling system today... and protection of their technology investment for the future. The Cable Preparation Tool is packed with every spool of Belden DataTwist 0e data cable. The Belden Cable Preparation Tool (1797B) now makes it faster and easier than ever to prepare cables for connector termination. This tool is ideal for use with Belden s Bonded Pair cables, providing special features that help separate twisted pairs. It can also be used to prepare any unbonded pair cable for installation. Pair Separation Techniques: Belden s Cable Preparation Tool features both the new Pick technique and the traditional Blade Slot technique to better facilitate pair untwisting. The Pick technique utilizes a steel awl that is incorporated into the tip of the tool that is surrounded on both sides with guards to assist in pair alignment during the pair separation step. The Pick technique allows for a simple pick-n-pull motion to easily separate the conductors of a twisted pair cable. The Blade Slot Technique provides the technician an alternate method for separating the conductors quickly and easily. See TB177 for detailed instructions for either technique. Table of Contents

Belden Data Cables (S)FTP Category 5E Belden 1E Belden 1ENH Belden 1E Belden 1ENH Halogen-free version Twin version of 1E Twin version of 1ENH Cat. 5E Product description Shielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain wire. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) 1 4 1..5 2.1 2.0 3.2.2 4.0 3..3.3 5.7 5.5.1.1.5.3.0.0.0.0 7..2.2 9.0.5...1 9.5.2.2.4..5 2.5 1.5 15.0. 2.3 19.3.0.0 Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.0 Impedance (Ohm): Ohm ± 15 % Single Twin E 4 9 ENH 4 9 0 ft. 5 m.0 kg 1 ft. 0 m kg 0 ft. 0 m.0 kg Belden A Bonded pairs Cat. 5E Belden ANH Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, lateral foil shield, spiral tinned copper drain wire, Nylon ripcord, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: ISO / IEC 01 Attenuation (db/ m) NET (db) PS-ELFET (db) ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 2 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.0 1 4.0.0 4 4.0 3.7.3 5.7 5.2.1.5 Nominal overall diameter (mm):.7 Impedance (Ohm): Ohm ± 15 %.3 5..0 1.0 7.4.2 9.0.3...4.4.5.5 1.5.7. 2 1.3 19.5.0 1 U 0 ft. U 5 m.3 kg 0 ft. 5 m 1.2 kg 0 ft. 0 m.2 kg Table of Contents

(S)FTP Category 5E Belden 1E+ Braided Cat. 5E Belden 1ENH+ Halogen-free version Belden 1E+ Twin version of 1E+ Belden 1ENH+ Twin version of 1ENH+ Product description Shielded Twisted Pair Cable. 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain wire and tinned copper braid. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) 1 4 1..5 2.1 2.0 3.2.2 4.0 3..3.3 5.7 5.5.1.1.5.3.0.0.0.0 7..2.2 9.0.5...1 9.5.2.2.4..5 2.5 1.5 15.0. 2.3 19.3.0.0 Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.3 Impedance (Ohm): Ohm ± 15 % Single Twin E 5 ENH 5 0 ft. 5 m. kg 1 ft. 0 m.0 kg 0 ft. 0 m.0 kg Belden 1E Patch Cat. 5E Belden 1ENH Halogen-free version Product description Shielded Twisted Pair Cable, 4 pairs x AWG 2. Stranded bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) 1 4 1..5 3.2 2.5 9 7 77.1 7 59.1.0 5.0.3.3.5 7.0 59.3.3.5 9.5 7.9...1 9.9.2.2..1.2.2 15.2.5.1 2.1 17.1.0....5...0 2.3 3.3 0.3, Red, Green, Yellow Typical velocity of propagation (%): Max. DCR (Ohm/km): 1 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.95 Nominal overall diameter (mm): 5.2 Impedance (Ohm): Ohm ± 15 % Single E 0 ENH 5 Table of Contents 0 ft. 5 m.3 kg 1 ft. 0 m.5 kg 0 ft. 0 m.0 kg

Belden Data Cables (S)FTP Category Belden E Bonded pairs Cat. Belden ENH Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) 1 4 1..5 1 2.1 0.2.2 7 3. 3.5 7 3 74.4 59.4.0 5.5.3.3 3 7..9 7...5 7..3.3 9.....7 9.7 3.1.1 15.5..9.9 19.9 17.7.4.4.3.4 17.1.1.1.1 19.. 1.0 2.0 2.2 17.3 17 3.3 15 17.3 Typical velocity of propagation (%): Max. DCR (Ohm/km): 91 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.17 Nominal overall diameter (mm): 7.2 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 5 1 ft. 0 m.9 kg 0 ft. 0 m.0 kg Belden E+ Bonded pairs Braided Cat. Belden ENH+ Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire and tinned copper braid. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) 1 4 1..5 1 2.1 0.2.2 7 3. 3.5 7 3 74.4 59.4.0 5.5.3.3 3 7..9 7...5 7..3.3 9.....7 9.7 3.1.1 15.5..9.9 19.9 17.7.4.4.3.4 17.1.1.1.1 19.. 1.0 2.0 2.2 17.3 17 3.3 15 17.3 Typical velocity of propagation (%): Max. DCR (Ohm/km): 91 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.17 Nominal overall diameter (mm): 7.5 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 5 1 ft. 0 m 2.5 kg 0 ft. 0 m.9 kg Table of Contents

ISTP Category 7 Belden 15ENH Halogen-free Cat. 7 Belden 17ENH Twin version of 15ENH Product description Shielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper, foam skin polyolefin insulated, pairs individually shielded with Aluminum/Polyester foil, overall tinned copper braid, ripcord, flame retardant. Colour code: see DataTwist colour code table below. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 7) 1 4 1.2.5 1 2.0 9 95 7.0 9.0 9 2 3.7 3.5 9 95 74.3 97.3 95 5.9 5.4 9 95.1 95 9.1 93 7.4.9 9 7 90. 93 7. 91.3 7. 9 7 9.7 92.7 90.4 9. 9 4 7. 90..9. 9 0.. 4 19.0 17.4 95 9 93 7.4.4 7.0.7 95 7 93...5.7 95 93.4.4 1.0 0.2.5 90.1 2.1 1. 2 0 0.1.9.. 90 90..4 7..7.1 2 Standard colour: Grey Velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1. Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % 2 0 MHz: ± % Single Twin ENH 0 0 1 ft. 0 m.0 kg 0 ft. 0 m.0 kg Ordering Information & DataTwist Colour Code Table Page 7 7 9 9 Belden part number E, ENH 17E, 17ENH A, ANH E, ENH 1592A* 17A* 79E, 79ENH E, ENH 1A, 1ANH 1GB* A, NH 1797B 1E, 1ENH 1E, 1ENH A, ANH 1E+, 1ENH+ 1E+, 1ENH+ 1E, 1ENH E, ENH E+, ENH+ 15ENH 17ENH * Halogen-free version available upon request. DataTwist colour code table: Pair no. 1 White/Blue & Blue Pair no. 2 White/Orange & Orange Pair no. 3 White/Green & Green Pair no. 4 White/Brown & Brown Colour Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet, White, Black Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet, White, Black Grey (RAL ), Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey, Gold, Brown, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Violet, White, Black Grey, Blue (RAL 15), White Cable preparation tool (White) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15), Red, Green, Yellow (RAL) Grey (RAL ), Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey (RAL ) Notes: Special put-ups available upon request. Packaging on non-returnable reels, unreel box (U-5 m) or reel in box (A-5 m). Table of Contents Standard lengths (put-ups) U-5 m, 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m U-5 m, 5 m 0 m, 0 m U-5 m, 0 m, 0 m m, A-5 m A-5 m, 5 m A-5 m, U-5 m, 5 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m, 0 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m 0 m, 0 m 0 m, 0 m 0 m, 0 m 0 m, 0 m

Belden across the globe Europe: The Netherlands (European Headquarters) Belden Wire & Cable B.V. Edisonstraat 9 592 PG Venlo The Netherlands Phone: + 77 5 Fax: + 77 E-mail: sales.info@belden-europe.com Web: www.belden-europe.com France Belden Electronics S.A.R.L. Immeuble Le César, Place Louis Pradel 9001 Lyon France Phone: + 2 9990 Fax: + 9 Hungary Belden Dunakabel Kft. Hengermalom Str. 1 Budapest Hungary Phone: + 0 197 Fax: + 0 19 Italy Belden International Inc. Via Paracelso 2 Centro Direzionale Colleoni Palazzo Cassiopea Ingr. 3 Agrate Brianza (MI) Italy Phone: + 0 9 Fax: + 0 9 Russia Belden Office Moscow UL. Gubkina, Moscow Russia Phone/Fax: +7 095 9 Sweden Belden Wire & Cable B.V. Stadshusplatsen 2 1 Nynäshamn Sweden Phone: + 02 Fax: + 0 United Kingdom Belden Communications Division Delaunays Road, Blackley Manchester. M9 FP United Kingdom Phone: + 1 7 91 Fax: + 1 795 3 E-mail: sales@belden-cd.co.uk Web: www.belden-cd.co.uk World-wide: Africa/ Middle East Belden Wire & Cable Dubai Internet City Building One, Suite P.O. Box 01 Dubai United Arab Emirates Phone: +9 4 1 00 Fax: +9 4 1 7 Australia Belden Australia Pty. Ltd. Olympia Street Tottenham, Victoria Australia Phone: + 3 92 Fax: + 3 94 5 Canada Belden Canada Inc. 1 Willmott Street Cobourg, Ontario Canada K9A 4M3 Phone: +905 2 3 Fax: +905 2 Singapore Belden International, Inc. 1 Thompson Road, #07-02 United Square Singapore 91 Phone: +0 2 1 Fax: +0 2 United States Belden Wire & Cable Co. P.O. Box 190 Richmond, IN 5 United States Phone: +1 7 93 00 Fax: +1 7 93 All sales of Belden products are subject to Belden s terms and conditions of sale. All printing errors are subject to correction. Technical specifications are subject to change without notice. The author reserves the right not to be responsible for the topicality, correctness, completeness or quality of the information provided. Liability claims regarding damage caused by the use of any information provided, including any kind of information which is incomplete or incorrect, will therefore be rejected. Copyright 3, Belden Inc. 09.03. 00 Reprinting and reproduction, in whole or in part, prohibited.