The Green Data Center



Similar documents
Re Engineering to a "Green" Data Center, with Measurable ROI

Green Data Centre Design

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data Center Facility Basics

Reducing Data Center Energy Consumption

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Increasing Energ y Efficiency In Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Office of the Government Chief Information Officer. Green Data Centre Practices

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

DOE Data Center Energy Efficiency Program

Energy Efficiency and Availability Management in Consolidated Data Centers

Environmental Data Center Management and Monitoring

Sanjeev Gupta Product Manager Site and Facilities Services

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Greener Pastures for Your Data Center

Top 5 Trends in Data Center Energy Efficiency

DataCenter 2020: first results for energy-optimization at existing data centers

Enterprise Data Centre

THE GREEN DATA CENTER

Benefits of. Air Flow Management. Data Center

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Advantages on Green Cloud Computing

Dealing with Thermal Issues in Data Center Universal Aisle Containment

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Data Center Equipment Power Trends

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Convergence of Complexity

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Server room guide helps energy managers reduce server consumption

Information Technology White Paper

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Center Leadership In the DOE Better Buildings Challenge

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

Data Center Energy Profiler Questions Checklist

Figure 1: Comparison of Projected Electricity Use,

Data Centre Capacity and Electricity Use How the EU Code of Conduct can help your data centre electricity bill

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

The New Data Center Cooling Paradigm The Tiered Approach

Building a data center. C R Srinivasan Tata Communications

Using Outside Air and Evaporative Cooling to Increase Data Center Efficiency

BC43: Virtualization and the Green Factor. Ed Harnish

WHITE PAPER Server Innovations: Examining DC Power as an Alternative for Increasing Data Center Efficiency and Reliability

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Protecting Our Information, Protecting Our Resources

Data Center Energy Use, Metrics and Rating Systems

Greening The Data Center

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Identifying Energy Saving Opportunities in the Data Center

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

- White Paper - Data Centre Cooling. Best Practice

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.

The Mission Critical Data Center Understand Complexity Improve Performance

ServiceXen Thoughts about IT Strategy and Management

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Data Center RD&D at EPRI

Why Data Center Design and Innovation Matters

Top 10 Ways to Save Energy in Your Data Center

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

datacenter2.0 Chapter 1, 2008 Update Building the Business Case for Data Center Efficiency IMPLEMENTING ENERGY EFFICIENCY ROOT CAUSES OF DEMAND

Imperial College 3 March 2009 Green Data Centers: An Overview

Australian Government Data Centre Strategy

Energy Efficient High-tech Buildings

Solutions to Make Your Data Center Energy Effi cient

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center

Enclosure and Airflow Management Solution

80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging

Data Center Efficiency Metrics and Methods

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

Sustainability Watch. Data Center Energy Efficiency. Data Center Energy Efficiency Is Fast Becoming a Priority. Watch List.

Virtualization of IT environments as ecological alternative in the data center

Expert guide to achieving data center efficiency How to build an optimal data center cooling system

HP Data Center Efficiency For The Next Generation. Pete Deacon Canadian Portfolio Manager Power and Cooling Services

Keywords green data center, energy efficiency metrics, green design, green disposal, green operations, green procurement

Initial Steps in Capacity Management for the Green Datacenter

How green is your data center?

Rittal Liquid Cooling Series

The green data center.

Energy Savings in the Data Center Starts with Power Monitoring

Virtual Infrastructure: A Guide to Bottom-Line Benefits WHITE PAPER

Jonathan Mitchell CDS Research Project April 18, 2012

Greening Commercial Data Centres

Greener IT Practices. Anthony Suda Network Manager

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

U.S. Department of Energy, National Renewable Energy Laboratory, IT Sustainability Case Study

Data center upgrade proposal. (phase one)

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Green Computing: Datacentres

Transcription:

The Green Data Center Energy Efficient Computing In The 21st Century The Green Data Center: Energy Efficient Computing In The 21 st Century Matt Stansberry Site Editor TechTarget mstansberry@techtarget.com www.searchdatacenter.com Abstract Data center energy efficiency can curb runaway power consumption, and also accommodate more data center capacity. Energy costs are going to rise and computing demand will continue to outstrip technological improvements. This session will outline short term and long term strategies for going green in the data center.

Business Case For Energy Efficiency The Uptime Institute estimates that building a 30,000 square foot data center can cost up to $300 million today, compared with only $20 million a few years ago. 2005 AFCOM survey: Data center power requirements are increasing by an average of 8% - 20% per year. In 2007, 44.5% of AFCOM members data centers would be incapable of supporting business requirements due to capacity constraints. OBSOLETE BY 2010 According to AFCOM, more than 60% of pre-2005 data center facilities will be unable to handle increased computing demand, rendering data centers obsolete in three years. Data Centers In The Spotlight This isn t a fad: Traditional energy costs are going to rise. At the same time, demand for new application growth will continue to outstrip computing advances. Going green Crisis or opportunity? All eyes on the data center, from the C- level to Congress. Data center managers are playing a key role in shaping their company s future and U.S. energy policy.

Does $300 Million Get Your CFO s Attention? In order to pursue energy efficiency, you need C-level commitment: Understand energy consumption trends Develop a strategy Implement metrics to measure progress Measuring IT Energy Consumption Server energy use doubled from 2000-2005 Servers in the U.S. burned 23 billion kilowatt-hours (kwh) in 2005 Every kwh used by servers translates into another kwh of electricity for infrastructure Data centers used 45 billion kwh in the U.S. in 2005, $2.7 billion In 2010, data center electricity use will be 76% higher than in 2005 Source: Jonathan Koomey, LBNL & Stanford: http://enterprise.amd.com/downloads/svrpwrusecompletefinal.pdf What Is Driving Demand? New applications: RFID, Webapplications, digitization of business processes Increased uptime: 24x7 global business, SOX and other legal requirements and user expectations of always-up systems Web 2.0: The Google-plex, user generated content, SaaS and Second Life

The True Cost Of Ownership IT managers justify the capital cost of telecommunications, storage and server hardware to support an application -- but not the supporting infrastructure power cost. Total cost of ownership is invisible to the people provisioning IT resources because they don t see the power bill. The power bill for the data center is the domain of the facility engineering staff -- it is abstracted from the technology decisionmaking process. TCO Estimates The Uptime Institute: The three-year cost of powering and cooling servers is one and a half times the capital expense of the hardware. Gartner: Energy costs will account for more than half of a company s IT budget in the next few years. Computers Run On Coal Half of all the electricity generated in the U.S. comes from coal-burning power plants. By reducing energy consumption, we lessen the demand to build more of these polluters. The Union of Concerned Scientists estimates that a 500-megawatt coal-burning power plant generates: 3.7 million tons of carbon dioxide, the primary cause of human-related global warming; 10,000 tons of sulfur dioxide, which causes acid rain; and 500 tons of airborne particles, responsible for respiratory health problems.

Green Consumers The green consumer is emerging. End users may demand that companies practice environmentally sound policies -- which could include energy efficient IT operations. LEED In The Data Center? The U.S. Green Building Council s Leadership in Energy and Environmental Design (LEED) is the green building standard. A few companies have certified LEED data centers, including Highmark in PA and Fannie Mae in Urbana, MD. More companies have committed to LEED, including IBM and 365 Main. The Problem With LEED LEED is not designed for data centers and so far the USGBC does not plan to address them. LEED drives perverse design incentives in the data center: Gain points for bike racks and day -- lighting, no points for mitigating bypass airflow or server virtualization.

If Not LEED, Then What? The Green Grid, The Uptime Institute and the EPA can lobby and develop a LEED-DC for the USGBC; or develop their own metric and awards system for data centers. Get involved: The Green Grid needs user members; TUI is developing opinions and testing ideas; EPA representatives are traveling the data center conference circuit. Managing Up You can t drive efficiency from the bottom up. Nobody gets promoted for unplugging servers. Make the business case to the CIO to include energy costs part of annual allocations for computing costs. Implement metering equipment for measuring energy use. Make it a quarterly reporting item. Comparative Metrics Server metrics: EPA and Spec are developing a rating system and eventually an Energy Star label for 1U-2U servers. Data Center Metrics: The Uptime Institute and The Green Grid have developed data center-wide efficiency metrics called SIEER and PUE.

Energy Star for Servers Measuring efficiency of the server power supply Examining power save features at the OSfirmware level Using SPEC benchmark to calculate the amount of energy it takes for various servers to perform a set unit of work. The first workload that the new SPEC power metric will measure is server-side Java. The energy measurements are made at the AC input to the system under test. Site Infrastructure Energy Efficiency Ratio Power in to the data center (measured at the utility electric meter), divided by power out used to run the IT equipment for computing. Uptime: 85 corporate members (the largest financial data centers in the world) have an average SIEER of 2.5. This means that for every 2.5 watts in at the utility meter, only one watt is delivered out to the IT load. Uptime estimates a best case scenario of 1.6 SIEER for companies with the most efficient equipment and no over provisioning capacity. Power Usage Effectiveness Industry support from The Green Grid and the American Society of Heating, Refrigeration and Air- Conditioning Engineers (ASHRAE). PUE is essentially the same equation as represented in SIEER. The Uptime Institute and The Green Grid will likely meld these benchmarks under one name.

Why Metrics Matter Metrics like SIEER and PUE will help data center managers make better decisions. You can t manage what you can t measure. This will give us empirical evidence on which energy efficient best practices are really working and allow users to determine ROI on projects. PART 2: Strategies Short-term, Mid-term and Long-term Goals for energy savings Short Term, Low Cost, Low Risk Fixes WHAT CAN YOU DO TODAY? Turn off unused servers Consolidate with server virtualization Audit hot-aisle/cold aisle design Switch power distribution from 120v to 208v

Server Virtualization = Magic? Consolidation: Server virtualization is the key to extract more from underutilized servers. 3 years ago, 80% of your servers were running at 5%-15% utilization. Today with VMware you can collapse 5-10 operating systems onto a single machine, cluster them for failover protection and use fewer servers. Server Virtualization (Continued) California utilities are paying customers 50% of the cost (up to $4 million) of a virtualization project. One user in the pilot program used VMware to reduce the number of servers from 1,000 down to 270. Another is virtualizing 260 physical servers onto 11 VMware hosts. Estimates by VMware and the utility companies are that direct energy savings for each server removed run between $300 and $600 per year. Raised Floor Fundamentals Eighteen inches is the minimum raised floor height -- 24-30 inches is better. Get rid of the clutter, unused cables or pipes. Hire a service to clean it periodically. Seal cable cutouts, spaces between floor and the walls. Replace missing tiles. Use rubber gaskets under tiles to fit them more snugly onto the frame, minimizing air leakage. Use products to seal up raised floors, including brush grommets and specialized caulking.

Raise The Voltage, Save Power Servers will see a 2-3% efficiency gain by using 208V versus 120V power distribution. Servers are rated to handle 100-250 volts. They can auto-sense 208V and adjust automatically. Most PDUs can deliver 208V and 120V to the same power strip. Near-term Solutions 1 Year Out Buy Energy Star rated servers with 80-Plus power supply certifications. Upgrade to Windows Server 2008 for power down features. Consider consolidating Linux onto big iron for mainframe customers. Investigate supplemental cooling systems. 80-plus Power Supplies The easiest way to gain efficiency is to buy servers with the 80 Plus rating on the power supply -- standards are available and it has zero impact on the processor. This component converts AC power at the plug into DC power that a server can use. In 1U rack servers, the power supplies convert AC to DC very inefficiently, typically at around 60%-70% efficiency.

80-Plus (Continued) Products must run at 80% or greater efficiency at varying server workloads. 80-Plus does not extend beyond 1U servers today. Google spends $30 extra per server for 90% efficient power supplies which pay for themselves over the life of the server. Windows Server 2008 Power management is built into Windows Server 2003, but most users never enabled it. Windows Server 2008, shipping February, power management is enabled out of the box. New power management features provide finer controls that allow the OS to scale back voltage going to the processor. This improves on the current processor power management strategy of putting CPUs to sleep when servers are idle, which can result in latency issues in spikes and lulls in demand. The Mainframe And Energy A mainframe s average CPU utilization is 90%. IBM guaranteed customers that a mainframe uses less energy than the comparable volume servers to do a job. In 2005, Nationwide moved 5,000 open system workloads onto Linux on the mainframe and reduced its data center floor space and power consumption by 80%. Big Iron seems to be a great consolidation platform for existing customers.

Supplemental Cooling Systems High density cooling systems can deliver more cooling than raised floor with less energy; deliver air more evenly up the cabinet; deliver cooling closer to the heat source; and prevent bypass airflow by directing exhaust air directly into the AC unit. On the downside these systems can be more expensive and complex to operate. In many cases you still need the raised floor to maintain baseline cooling and humidity. Many top-blow systems need to be ducted, taking up a lot of space. Long-term New Construction THE FUTURE! Liquid cooling Air-side and water-side economizers DC Power Liquid Cooling Systems? Water is about 3,500 times more efficient than air at removing heat. Vendors offer all sorts of products but nobody is buying yet. 65% of data center managers say no to liquid cooling. Liquid refrigerants seem to have mechanical advantages over water. ASHRAE published a liquid cooling book last year -- first steps to standardization.

Economizers: Free Cooling? Air-side economizers bring cold outside air into the data center. This allows you avoid using chillers and compressors. Unconditioned air is bad for equipment: Humidity and particulate issues. Water-side economizers use outside air to cool chilled water -- a closed loop with less equipment issues. DC Power: Pros and Cons Pro: Studies say DC powered data centers are 10-20% more efficient. Con: You can t just go plugging servers into racks with DC. Every time you plug something in it changes the current draw. Con: DC UPS systems cost 20% to 40% more. Con: DC equipment is scarce. Sun, Cisco and Rackable offer a lot of DC products, but HP, IBM and storage vendors are lacking. Resources & Questions ebook: The Green Data Center Energy efficient computing in the 21 st Century SearchDataCenter.com News, expert advice, peer blogging. AFCOM, ASHRAE, The Uptime Institute, The Green Grid, EPA

Questions?? Visit me today at the ATE booth on the exhibit hall floor from 1:30 PM 2:30 PM