Open Channel Diffusers



Similar documents
Pacific Pump and Power

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 4000 OPEN CHANNEL MIXER R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

WAVELET WATER QUALITY MONITORING KIT

3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

SECTION 5: SANITARY SEWER SYSTEM DESIGN

pvc well casing & drop pipe

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Flow Measurement Options for Pipeline and Open Channel Flow

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

10/9/2012. Poultry Farm Water Supply. Alabama Burglar & Alarm System. Industry Upgrades. Drinkers Fans Water Supply

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

CHAPTER 3 STORM DRAINAGE SYSTEMS

Basic Selection & Proper Application of Overhead Air Distribution Devices

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

In-Line Air Separators

CLEANING, INSPECTION, AND TESTING OF SEWERS

Potted Plant Watering Systems

Potted Plant Watering Systems

MATHEMATICS FOR WATER OPERATORS

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

FLUID FLOW Introduction General Description

DESIGN, TESTING, AND OPERATING EXPERIENCE OF A SALTWATER DISPOSAL SYSTEM OIL-WATER SEPARATOR

Pressure Drop Basics & Valve Sizing

Chokes. Types Reasons Basics of Operations Application

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

ABC & C 2 EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams

Wastewater Collection Practice Test #3 Page 1 of 15

The conditions below apply to the curves shown on the following pages.

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

C. starting positive displacement pumps with the discharge valve closed.

APPENDIX B DESIGN GUIDELINES FOR APPROVED TREATMENT METHODS

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Fiberstars Mini Lighted Laminar Flow Fountains

Math. The top number (numerator) represents how many parts you have and the bottom number (denominator) represents the number in the whole.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Triple Service Valve Assembly

This will also provide you with the knowledge to insure long life for your Investment

Selection Of Centrifugal Pumping Equipment 1

Exhaust Calculation Booklet

Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Minor losses include head losses through/past hydrants, couplers, valves,

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

2. Parallel pump system Q(pump) = 300 gpm, h p = 270 ft for each of the two pumps

Centrifugal Fans and Pumps are sized to meet the maximum

08.08 Vic-Check Valves

BASIC MATH FORMULAS - CLASS I. A. Rectangle [clarifiers, ponds] I = length; w = width; A = area; area in square ft [sq ft]

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

Experiment (13): Flow channel

Saving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission

Control ball valves for severe services. Author: Michele Ferrante, PARCOL S.p.A., Italy

Cartridge Filter Application Notes

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Sanitary Sewer Overflow (SSO) Incident Report Form

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Open Channel Flow Measurement Weirs and Flumes

Technical Information

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Practice Tests Answer Keys

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 003 SANITARY SEWER COLLECTION SYSTEM

Method to Determine PERFORMANCE OF INDIRECT-FIRED WATER HEATERS March 2003 Edition

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

MAXIMIZING THE OUTPUT OF YOUR BRAKES Getting Your Pedal Geometry Right

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Hydrant flow testing data provides important

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the

SC-07 STORM DRAIN INLET PROTECTION

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Fabricated Drainage Products

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

OAR52 A-1 (September, 1981)

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

Pressure Reducing Valve Calculation Example

Flashing and Cavitation

Theory, Application, and Sizing of Air Valves

HOSE & CABLE PROTECTION

Agilent T-1 3 / 4 (5 mm), T-1 (3 mm), 5 Volt, 12 Volt, Integrated Resistor LED Lamps Data Sheet

Three Channel Optical Incremental Encoder Modules Technical Data

Free Pre-Algebra Lesson 55! page 1

Electric Motors and Drives

Air Eliminators and Combination Air Eliminators Strainers

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

RECON WATER HEATER INSTALLATION FORM

Pipe Flow-Friction Factor Calculations with Excel

Transcription:

Open Channel Diffusers Application Information: Open channel diffusers are used to increase mixing and absorbance efficiency of a chemical solution into the process water. Specifically designed penetrations in the open channel diffuser pipe provide multiple locations of chemical introduction along the diffuser pipe which then allows for more adequate and complete mixing. This design guide shall provide the parameters and framework necessary to size a complete and efficient open channel diffuser for chemical injection. Ordering Through : is able to offer a variety of open channel diffuser options to fit the needs of specific customer requirements. All open channel diffusers are made to order and the following parameters need to be specified: Diffuser diameter and material of construction. Diffuser length. Diameter and number of penetrations. Number of rows required. Spacing of penetrations. Additional Supports.

Initial Assumptions: Due to the variability of open channel diffuser design and specific site mixing conditions, the following assumptions have been developed to ensure that open channel diffusers will operate at peak efficiency. 1. The pressure drop through the diffuser shall be set at 4 psi. This will allow complete mixing and injection through all penetrations in the diffuser. 2. The distance between holes should be approximately 4-6 inches laterally on diffusers over 8 feet long. 3. The diffuser shall be at least 12 inches below the surface of the water. This shall ensure adequate absorbance of the chemical into the process water without off gassing. 4. Diffusers placed in any open channel shall be placed in the channel area of maximum turbulence. 1. Determine New Backpressure and Water Flow Requirements: Based on the initial assumptions, the open channel diffuser will add approximately 4 psi of backpressure to the application backpressure. This additional backpressure must be added to original design estimates (if not included) in order to adequately size the ejector for the required inlet pressure and flow rate. Once a new backpressure is determined, refer to ejector performance curves to find the inlet pressure and water flow rate necessary for your application. 2. Pipe Diameter and Material of Construction: The diffuser material of construction should be selected for maximum corrosion resistance. Standard material provided by is schedule 80 PVC pipe and is recommended for most applications, especially chlorine injection. The diffuser diameter shall be sized by similar methodologies used to size other pipes in the plant. Generally, these methods limit the velocity through the pipe to approximately 3-6 ft./sec. Based on the water flow rate required in step one, an adequate pipe diameter can be determined using the equation below. D = Diffuser inner diameter (inches) Q = Water/solution flow rate (GPM) v = Velocity (ft./sec). Must be between 3-6.

3. Determine Size and Number of Penetrations: Use the table below and the water flow rate requirements determined in step one to determine the diameter of and the number of penetrations needed for the diffuser. Water/Solution Flow Rate (Q) GPM Number Of Penetrations (N) Orifice/Penetration Diameter (d) inches 3/16 1/4 5/16 3/8 1/2 5/8 3/4 20 16 9 - - - - - 25 20 11 7 - - - - 30 24 13 9 - - - - 35 27 16 10 7 - - - 40 31 18 11 8 - - - 45 35 20 13 9 - - - 50 39 22 14 10 - - - 55 43 24 15 11 - - - 60 47 26 17 12 7 - - 65 51 28 18 13 7 - - 70 54 31 20 14 8 - - 75 58 33 21 15 8 - - 80 62 35 22 16 9 - - 85 66 37 24 17 9 - - 90 70 39 25 18 10 - - 100 78 44 28 19 11 7-120 93 53 34 23 13 8-140 109 61 39 27 15 10 7 160 125 70 45 31 18 11 8 180 146 79 50 35 20 13 9 200 156 88 56 39 22 14 10 220 171 96 62 43 24 15 11 240 187 105 67 47 26 17 12 260 202 114 73 51 28 18 13 280 218 123 78 54 31 20 14 300 233 131 84 58 33 21 15 320 249 140 90 62 35 22 16 340-149 95 66 37 24 17 360-158 101 70 39 25 18 380-166 106 74 42 27 18 400-175 112 78 44 28 19 Bold = Recommended

4. Determine Number of Rows: Based on the number of penetrations required in step 3, it may be more effective to go with two rows instead of one. To determine the number of rows use the equation below. If R est is greater than 1.5, then two rows should be used. If R est is less than 1.5, then one row should be used. N = Number of penetrations L = Effective Length (feet)* *The effective length (L) is the length of the diffuser that is available to make the diffuser penetrations. Since there are requirements for mounting the diffuser and space required for the inlet connection, the whole length of the channel cannot be used, and this is why an effective length is required. Based on open channel diffuser design configurations, the following lengths can be subtracted from the diffuser/open channel length to obtain the effective length. Nominal Pipe Size (inches) 5. Orientation and Spacing of Penetrations: Length To Subtract From Overall (inches) 1 9.75 1.5 11.5 2 14.75 2.5 17.75 3 21 4 22.75 Penetrations should face directly upstream of the process water to allow for better mixing. If two rows of penetrations are required then each row will be spaced 22.5 degrees from center. The center to center spacing of penetrations in the same row can be determined from the equation below. S = Center to center spacing (inches) L = Effective length (feet) R = Actual number of rows N = Number of penetrations

Example: Design a diffuser for a 120 GPM system (determined from step 1). Channel width is 7 feet. Initial data: 2. Confirm pipe is appropriate diameter: 3. Find recommend penetration diameter and number of penetrations based on required flow rate. 34 penetrations are required at 5/16 DIA. 4. Determine the number of rows: Since the value is greater than 1.5, two rows are required. 5. Determine center to center spacing: water line 12" min. 5.25' 3.5" D = 0.31" (34 places) D = 3" 7'