e NT: R.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr 00 and 400 Installation Guide This guide provides instructions for an experienced installer to install and connect the Extron 00 and 400. The units are furniture-mounted enclosures for cable access, connections, and AC power. s that are not in use can be stored out of the way while remaining connected to the presentation system. Planning Check with local and state regulations before starting the installation: Ensure that the planned installation complies with building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements. Check all parts and equipment before installation: Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation. Kit Contents 00 400 A 5 00 00 400Plugs 400 00 Plugs 00 Mounting Screws -40 Screws Plugs Plugs 400 and Star Washers PlugsScrews ounting Screws d Star #6 Washers Mounting Screws Screws 00 0 Screws Screws 00 Plugs Pin & Clip 400 400 400 A T A 5 Zip Zip TiesTies 400 Screws 400 00 Plugs00 00 00 00 A A T A T 5 A T A #6 Mounting Screws #6 Mounting StarScrews Washers andand Star Washers A 5 A 5 Screws Screws A T A 5 (/4") (/8"), 4 (/4") 400 & Clip Pin Pin & Clip 400 Pin & Clip A 5 Pin Pin&&Clip Clip Plugs 8 Screws A Pin & Clip 6 A Power AC AC Power Frame AAPAAP Frame 5 5 5 8 400 Pin & Clip PlugsScrews 4 Plugs Plugs Pin & Clip 6 (/8"), A 5 Pin & Clip
00 and 400 Installation Guide (Continued) Preparing the Table Cut a hole in the surface where the enclosure will be installed. Read the following information before making a cut. Determine the best location for the enclosure Ensure that the location where the is to be installed is convenient for as many users as possible. Ensure that the edge on which the lid opens is oriented correctly. Ensure that there is ample space under the table for cables. When installing retractors in the, ensure that there is enough space for the retractor assembly under the table or furniture. See dimensions for the retractors below. 9." (.4 cm) Table Top 4.9" (7.8 cm) 0.6" (6.9 cm) 6.7" (67.8 cm) 7.8" (45. cm).5" (59.7 cm) 0.8" (5.8 cm) 9.4" (74.7 cm) X Models.7" (60. cm) 0 X Models Choose a method for cutting the hole in the table The opening in the table for the should be cut only by licensed and bonded craftspeople. CAUTION: Wear safety glasses when cutting the hole in the table. Failure to comply may result in eye injury. The edges are sharp. Exercise care to prevent scarring or damaging the skin and furniture. Choose one of the following methods for cutting the hole: Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router If using a CNC wood router or other precise machinery, use the exact cut-out dimensions for your model (see the table below). Cut-Out Template for the Extron 00 Cut-Out Radius: 0.5" (0.6 cm) Visit www.extron.com for routing template part numbers and instructions. User Access Outer Edge of Front Bezel (Do not cut this line.). Confirm the product to be installed.. Remove the surface cut-out area (gray) from the template.. Measure the cutout and template. 4. Mark the position on the furniture where the 00 will be installed. 5. Double check the dimensions and position, then cut the opening. Dimensions and print-out templates are available online at www.extron.com. Trim Ring ip P/N 68-47-0 Rev. A Page Size: " x 7" Print Scale : Do not Shrink Cut-out Dimensions Product User Access Width CC 00 0.00" (54.0 mm) CC 400 0.00" (54.0 mm) Side Dimension 4.00" (0.6 mm) 6.75" (7.5 mm)
Preparing the Step Assemble s. modules allow you to populate the enclosure with a combination of AAPs, cable pass-through, or retractors. Follow the steps below to assemble the connectivity modules of your choice. Option : AAP AAPs in the AAP plate. Secure up to three single-space Secure up to three single-space AAPs in the AAP plate. Secure the AAP plate on the connectivity brackets, Secure using four the of AAP the plate provided on the module connectivity screws. brackets, using four of the provided module screws. Nut w/ Captive Nut Washer w/ Captive Washer Insert cables through the bottom of the connectivity bracket. Insert Connect cables cables through to the the AAPs. bottom of the connectivity bracket. Connect cables to the AAPs. NOTE: After assembling the module, proceed to Step Install the s on the next page. Option : Pass-Through Snap the included hole plugs into Snap any unused the included holes. hole plugs into any unused holes. Insert cables through the bottom of the connectivity bracket Insert and into cables the holes through of the grommet bottom of plate. the connectivity bracket and into the holes of the grommet plate. Secure the grommet plate on the Secure connectivity the grommet bracket, plate using on four the connectivity of the provided bracket, module using screws. four of the provided module screws. NOTE: After assembling the module, proceed to Step Install the s on the next page. Option : Secure the bracket using four of the provided mounting screws with star washers. Insert the bracket into the. The bracket may be installed on the left or right side of the enclosure and at the lowest height. NOTE: After installing the bracket, proceed to Step Install the s on the next page to install the power module. s are installed after the is mounted on the table (see Mounting s Under the Table on page 5).
Step Install the s. Determine where the connectivity modules and power module will be installed in the. The modules may be installed on the left or right side of the enclosure and at various heights. NOTE: Ensure that there is enough room above the modules for the lid to close completely. Secure the modules using four of the provided mounting screws and star washers. Secure the modules using four of the provided mounting screws and star washers. WARNING: Electric shock hazard. To ensure proper electrical grounding, use the provided #6- mounting screws with the star washers. Insert the modules into the. Insert the modules into the. Mounting the in the Table Mount the flush with the table. CAUTION: The edges are sharp. Exercise care to prevent scarring or damaging the skin and furniture. Remove the plastic strips and film on the surface of the Remove the plastic strips and film. on the surface of the. Ensure that the side clamps are seated Ensure that the side against clamps the are enclosure. seated against the enclosure. ower the into the hole to test the fit. If necessary, ower the carefully enlarge into the the opening. hole to test the fit. If necessary, carefully enlarge the opening. 4
00 and 400 Installation Guide (Continued) Under the table, adjust the side clamps on the enclosure. Ensure the is firmly seated in the table. Raise the lever to secure the. ever NOTE: To lower the side Rotate the side clamp outward and ensure that the lever is down. Slide the clamp all the way up against the bottom of the table. Ensure the is firmly seated in the table. Raise the lever to secure the. clamp, turn the lever down, then press and hold the locking plate while sliding down the clamp. ever Rotate the side clamp outward and ensure that the lever is down. ocking plate Slide the clamp all the way up against the bottom of the table. Ensure the is firmly seated in the table. Raise the lever to secure the. Mounting s Under the Table n. Horizontal or Angular Mounting For horizontal or angular mounting, remove these orientation screws (front and back), then follow the steps shown at left. Secure the clip on the pin. For installation details, see the Setup Guide available online at www.extron.com. Insert the pin through the retractor mounting hole on the side of the and retractor assembly. Insert the pin through the retractor mounting hole on the side of the and retractor assembly. 4 Insert retractors into the retractor bracket. Secure the clip on the pin. Secure the locking screw on each retractor. Do not overtighten. 5 Insert retractors into
Routing and Connecting s Connect cables to the AV system and connect the AC power cord. Using zip ties, secure cables to the holes on the bottom of the. For cable pass-through applications, allow at least 6 inches (0.9 m) of cable loop for each cable. Installation Checklist Planning (page ) Check with local and state regulations before starting the installation. Check all parts and equipment before installation. Preparing the Table (page ) Determine the best location for the enclosure. Choose a method for cutting the hole in the table. Preparing the (page ) Choose between AAPs, cable-pass through, and retractor connectivity to populate the. Secure the brackets and power module in the. Mounting the in the Table (page 4) Mount the flush with the table. Mounting s Under the Table (page 5) Routing and Connecting s (page 6) 68-45-50 Rev. B Extron Headquarters +800.6.9876 Inside USA/Canada Only Extron USA - West Extron USA - East +.74.49.500 +.99.850.000 +.74.49.57 FAX +.99.850.00 FAX Extron Europe +800.987.667 Inside Europe Only +..45.4040 +..45.4050 FAX Extron Asia +65.68.4400 +65.68.4664 FAX Extron Japan +8..5.7655 +8..5.7656 FAX Extron China +86..760.568 +86..760.566 FAX Extron Middle East +97.4.99.800 +97.4.99.880 FAX Extron Korea +8..444.57 +8..444.575 FAX Extron India 800.070.777 (Inside India Only) +9.80.055.777 +9.80.055.77 FAX 0 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com