theory FTHPL, T-RATED DO NOT POWER LUMINAIRE UNTIL INSTALLATION IS COMPLETE. SUSPENSION CABLES ARE POWERED. DO NOT ALLOW CABLES TO COME IN CONTACT WITH CONDUCTIVE MATERIALS. FRAGILE, HANDLE WITH CARE. GLOVES RECOMMENDED. DO NOT CLEAN WITH ALCOHOL. focal point key power off A power on attention B D E C parts list A - driver compartment B - theory pendant C - suspension assembly (x4) (cable, cable insulation (installed) & gripper cap) D - hard surface mount (mounting yoke, 1/4-20 wingnuts, 1/4-20 bolts, canopy & hardware) E - accessible ceiling mount (mounting brackets, cable sleeving, zip ties, 1/4-20 wingnuts & 1/4-20 bolts) ACCESSIBLE CEILING (G) 1 5-5/8" 29" 2-3/4" minimum 4" above tee for bottom access 5" secure mounting brackets to structure above mounting hardware by others IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 1 of 6
2 11 3 4 low voltage dimming only make electrical connections 5 6 1.75" 32" place 1/16" holes in ceiling material for cable suspension. install ceiling material. 7 8a x measure and cut sleeving to length cable label color must match terminals on both driver compartment and pendant positive terminals are indicated by black washers on both driver compartment and pendant 8b 8c 8d install sleeving and secure with zip tie REPEAT STEPS 8A-8D FOR ALL SUSPENSION CABLES IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 2 of 6
3.39 7 7/8" 9 10 11 X set suspension cables to desired length. 12 13 suspension cables may not come in contact with conductive materials. if cable exceeds length of insulation. cable must be cut and sealed (electrical tape or wire nut recommended) PENDANT INSTALLATION SEE PAGE 5 HARD SURFACE (HS) 1 ROUGH-IN 5 1/4" + - 1/8" ROUGH-IN 36 1/8" + - 1/8" X 3 7/8" + - 1/8" CEILING CUTOUT 5 1/4" + - 1/8" 3 7/8" + - 1/8" 35 1/2" + - 1/8" CEILING CUTOUT mounting yoke must be installed prior to ceiling material. mounting hardware by others. 2 3 4 IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 3 of 6
5 6 CABLE ARRANGEMENT 7 8 cable label color must match terminals on both driver compartment and pendant positive terminals are indicated by black washers on both driver compartment and pendant 9 10 secure housing 11 to yoke X low voltage dimming only see wiring diagram page 6 set suspension cables to desired length. make electrical connections 12 13 suspension cables may not come in contact with conductive materials. if cable exceeds length of insulation. cable must be cut and sealed (electrical tape or wire nut recommended) IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 4 of 6
15 16 PENDANT INSTALLATION fragile, handle with care. do not touch inside of pendant. 1 2 3 cable label color must match terminal color on pendant 4 5 1/16 allen wrench (by others) cleaning & care of pendant CLEAN WITH SOFT CLOTH & WATER ONLY! remove labels from cables IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 5 of 6
DRIVER SERVICE POWER OFF & REMOVE PENDANT PRIOR TO SERVICING. 1 FRAGILE, HANDLE WITH CARE. GLOVES RECOMMENDED. ACCESSIBLE CEILING (G) 2 2 HARD SURFACE (HS) FOR PENDANT SERVICE CONSULT FACTORY. Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited. IS0488 REV. C 2014 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 www.focalpointlights.com 6 of 6