FIBER OPTIC CABLE PLANT DOCUMENTATION



Similar documents
Specifying an IT Cabling System

FOA Technical Bulletin. Guide To Fiber Optic Network Restoration

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. Slide Number 1

SECTION TESTING OF FIBER OPTIC CABLES

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec )

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Reliable, Consistent, Quality

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

TCTC Cabling Specifications

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Fiber-to-the-Home/FTTH

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

imvision System Manager

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

Pantone Matching System Color Chart PMS Colors Used For Printing

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Special Specification 6033 Computerized Transportation Management System

How To Color Print

CADDSTAR V7.0 FEATURES AND FUNCTIONALITY

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Chapter 4 Connecting to the Internet through an ISP

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

Arista 40G Cabling and Transceivers: Q&A

Network Design. Yiannos Mylonas

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

FOA Technical Bulletin. Guide To Fiber Optic Network Design

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

For business. Wiring your business for broadband. What happens when copper is required?

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

TELEPHONE CABLING TECHNOLOGY INFINITY CABLING

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

Obsolete Fiber Technology? Not in my Data Center!

Telecommunications Training Catalog

Utilities and existing services

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Fiber Asset Management Software Internet2 Performance Working Group Joint Techs July Carla S. Hunt MCNC Mgr., Knowledge and Information Systems

H.V.A.C. Design Plumbing Design

STREETLIGHT SYSTEM GROUNDING AND BONDING

Request for Quote E-Rate Eligible Services Scope of Work - Internal Connections: Network Infrastructure Equipment and Cabling

Broadcast and Commercial AV Cabling MASTER CATALOG

Scope: Communications and Electronic Systems addressed in this section include:

SECURE Fiber Optic Products

General LAN Guidelines and Sign off process as mentioned in the Tender Document for High Court Coordinator

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

UT Southwestern Medical Center Information Resources Cable Installation Standard

Information and Communication Technology Network Cabling Infrastructure Standard

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

FOA Technical Bulletin. Guide To Fiber Optic Installation

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

SECTION 611 ACCEPTANCE PROCEDURES FOR TRAFFIC CONTROL SIGNALS AND DEVICES

IT&T Infrastructure Standards

SPECIFICATION STANDARD OPTICAL FIBER BACKBONE CABLING

Accurately Testing fibre Optic Cables

NRG Energy Center Minneapolis

Brief Engineering Assessment: Cost estimate for building fiber optics to key anchor institutions

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Terminating 25-Pair Cable and 4-Pair Cross Connects

DEPARTMENTAL REGULATION

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va / Fax 434/

E Series. E Series. Category 6 and 5e. Features

21 st Century Campus Network Responsibility Matrix 5/26/10

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Table 1A. Ship Kit List & Quantity

InstaPATCH ZERO Solution Guide

InstaPATCH Cu Cabling Solutions for Data Centers

Technical Bulletin. User s Guide To Fiber Optics

FTTH ARCHITECTURE WHITE PAPER SERIES

SECTION FIBER OPTIC CABLE AND ACCESSORIES

1 Campus Cabling Systems Introduction

How To Safely Dig For Natural Gas

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

ViZion Installation Guide

BID TABULATION Fiber Optic Cable Materials Bid # March 16, 2011 at 11:00 am CDT

Operating Instructions

Telcordia Network Engineer Andrius Petrauskas Project Manager

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

March Commissioning of Communications. See Appendix E

EZ-H Owner s Manual. Integrated HDMI over Fiber Optic Cable

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Transcription:

C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting the installation properly as part of the planning process can save time and material in the installation and allow better planning for upgrading. During installation, it will speed the cable pulling and installation since the routing and terminations are already documented. After installation, the documentation can be completed with test data for acceptance by the end user. If equipment is repositioned on a network, as is always the case, proper documentation will allow easier rerouting to the proper end points. And during troubleshooting, proper documentation is mandatory for tracing links and finding faults. The documentation process for fiber optics, however, is different from that of most copper cable installations. Where a copper cable of Cat 3 or 5 type is generally used to connect a single link, fiber optic cables especially backbone cables may contain many fibers connecting a number of different links that may not even be going to the same place. Furthermore, copper cable may be tested only for continuity while loss data will be required for most fiber optic cable plants. 137

138 CHAPTER 13 FIBER OPTIC CABLE PLANT DOCUMENTATION The fiber optic cable plant, therefore, must be documented as to the path of every fiber, connection, and test. Data that should be kept include the following: Cable: manufacturer, type, length Splice and termination points (at distance markers) Fiber: fiber type and size, splice and connection data, losses Connections: types (splice or connectors and types), fibers connected, losses Paths: where the link path goes in every cable Most of this data can be kept in a database that stores component, connection, and test data. Long links may also have OTDR data that can be stored as printouts or in special file formats for later viewing in case of problems. If the OTDR data is stored digitally, a database of data files should be kept to allow finding specific OTDR traces more easily. CABLE PLANT RECORD KEEPING Good cable plant record keeping can be used for many purposes. Designing the Cable Plant By starting with a simple graphic package showing the spatial relationship of the interconnections, you can design the layout of the entire cable plant; assign cable, fiber, and patch panel designations; and provide reports for each of the components and quantity used. For every cable you should specify the type of cable, installation method, number of fibers, types of fibers, and the length of the run. Bidding the Installation Job Good records and reports will give you all the information you need for estimating the total material content of the job and the length of cable runs. Individual cable reports will give you the details on special requirements for installation (direct burial, aerial, conduit, and so on) to help price labor costs and the total job. Installing the Cable Plant Records should provide the information you need to send materials to the proper location, determine what needs to be installed where, and make the proper interconnections. Patch panel printouts can be left taped inside the panel covers to provide local documentation of proper connections for checking during troubleshooting. Testing the Cable Plant After the cable plant is installed, keep test data on each individual fiber run. You can test any link or end-to-end loss and store it as a permanent record associated

CHAPTER 13 FIBER OPTIC CABLE PLANT DOCUMENTATION 139 with that fiber link. You can compare the data if you retest at a later date or have problems requiring troubleshooting or restoration. Note how the test was performed and what instruments were used. Use a power meter and source to get accurate end to end loss data and only use an OTDR if you need to verify splice loss (requiring bidirectional OTDR measurements) or to insure no bending losses were induced during installation. Troubleshooting Cable Plant Problems A well-documented cable plant will be much easier to troubleshoot. The documentation will tell you where cables go, what they are connected to, and how far they run between points, making problem areas easier to find. Test data will indicate any degradation over time that needs to be addressed. Documenting the Cable Plant for Customer Acceptance Most customers require documentation of the cable plant before acceptance. Good record keeping from the beginning, including all the data on the cable plant and final testing, will require only a copy as a report to the customer for acceptance. If customers wish to maintain their own cable plants, they can use the same data for future reference. THE DOCUMENTATION PROCESS Before you start entering data, you should have a basic layout for the network completed. A sketch may work for a small building network but a large campus or metropolitan network will probably need a complex computer-aided design (CAD) layout. The best way to set up the preliminary data is to use a facility drawing showing the locations of all cables and connection points. Identify all the cables and closets/panels and then you are ready to transfer this data to a database. You must know where all the cables go in the network and what every fiber will be connected to. You should know the specifications on every cable and fiber: what types of fiber are being used, how many fibers, cable construction type, estimated length, and installation technique (buried, aerial, plenum, riser, etc.) It will help to know what types of panels and closet hardware are being used, and what end equipment (if any) is to be connected. If you are installing a big campus cable plant with many dark (unused) fibers, some will probably be left open at the panels, and that must be documented also. When designing a network, it is a very good idea to have spare fibers and interconnection points in panels for future expansion, rerouting for repair, or moving network equipment (Figure 13-1).

140 CHAPTER 13 FIBER OPTIC CABLE PLANT DOCUMENTATION 05/19/2000 Cable List Detailed Report page 1 Cable ID: C001 Length: 1130 m Fibers: 8 Type: MM 62.5 Mfg: NLC Color: Orange Notes: Pulled through 4 in PVC duct in steam line tunnels to Library. 8 fibers, 900 um buffer, color coded. Cost Estimates: Cable Installation Termination (if included with cable) Panel A * Fiber ID * Notes Panel B ADM01-01-0001 C001-0001 red SCA01-01 ADM01-01-0002 C001-0002 orange SCA01-02 ADM01-01-0003 C001-0003 yellow SCA01-03 ADM01-01-0004 C001-0004 blue SCA01-04 ADM01-01-0005 C001-0005 green SCA01-05 ADM01-01-0006 C001-0006 violet SCA01-06 ADM01-01-0007 C001-0007 black SCA01-07 ADM01-01-0008 C001-0008 white SCA01-08 Figure 13-1 Sample of a cable report format. PROTECTING RECORDS Cable plant documentation records are very important. Keep several backup copies of each document, whether it is stored in a computer or on paper, in different locations. In fact, keep several copies on disks and on paper in different physical locations in case of disasters. If a copy is presented to the customer, the installer should maintain his or her own records for future projects. Access to modify records may be restricted using passwords if one wishes to stop unauthorized changes to the documentation.

CHAPTER 13 FIBER OPTIC CABLE PLANT DOCUMENTATION 141 REVIEW QUESTIONS 1. What data should be included with the documentation? a. b. c. d. e. 2. The first step in documenting a cable plant is a. a database. b. a sketch. c. test data. d. OTDR traces.