Primary and Secondary Electrical Distribution Systems



Similar documents
STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Atlanta Chapter IEEE Industry Applications Society

Secondary Unit Substations

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Alternate Methods to Short Circuit Breaker Coordination

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Fusible Disconnect Switch

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

This section applies to the design and installation of transformers.

Unified requirements for systems with voltages above 1 kv up to 15 kv

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Primary Electric Distribution for Industrial Plants

Sample - No Commercial Use

Contents. Description. Product Selection Guide

Choosing the Best Solution for Reducing Arc Energy

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Evaluating Water-Damaged Electrical Equipment

Evaluating Fire- and Heat-Damaged Electrical Equipment

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION

Extend the Life of Existing Switchgear

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

Evaluating Water-Damaged Electrical Equipment

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Step Voltage Regulators

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

Evaluating Water-Damaged Electrical Equipment

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

SECTION 16346A METAL-CLAD MEDIUM VOLTAGE ARC RESISTANT SWITCHGEAR

Low Voltage Switchgear

4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS

Switchgear and Metal-Enclosed Bus

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

LVA Take Offs in Bid Manager

SERVICE-LIFE EVALUATIONS OF LOW-VOLTAGE POWER CIRCUIT BREAKERS AND MOLDED-CASE CIRCUIT BREAKERS

MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED

Tmax MCCBs. Molded case circuit breakers. Tmax

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

TRANSFORMER DICTIONARY

Engineers Edge, LLC PDH & Professional Training

Medium Voltage Electrical Distribution

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

The Intelligent AX1 Switchgear for Medium Voltage

Short Circuit Current Calculations

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Power Plant Electrical Distribution Systems

The following components are common to most cubicles; this example is an ABB HK cubicle.

SECTION SUBSTATION TRANSFORMERS

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Transfer switch BTPC open, closed or delayed transition

SWITCHGEAR. EGP Switchgear

Transfer Equipment Controls

Safety By Design. Strategies for Electrical Contractors

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Medium Voltage Motor Control Assemblies

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Application of Four-Pole Circuit Breakers within Data Centers

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Hyperlinks are Inactive

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Introduction. Upon completion of Basics of Electrical Products, you should be able to:

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Part 1 System Modeling & Studies for Existing Systems

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

SECTION ELECTRICAL ACCEPTANCE TESTS

A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software

How to reduce exposure to arc flash hazards

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Arc Terminator Active Arc-Resistant Switchgear

FEDERAL ELECTRICITY & WATER AUTHORITY

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Advantages of Fixed Circuit Breaker Switchgear

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Motor Protection Voltage Unbalance and Single-Phasing

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

Minimizing Impact of Electric Utility Outages with Backup Generation

Diesel Engine Driven Generators Page 1 of 6

Transcription:

Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products

Utility Considerations Capacity Voltage and Sources Size of Metering Equipment Relaying Requirements Station Batteries

Utility Metering Requirements Dictated by the Utility EUSERC (as a reference) 15 kv: 48 W x 72 to 96 D 21 kv: 60 W x 96 D 38 kv: 72 W x 129 D

115 kv Substation Service (Approximately 80 by 75 )

Types of Systems Radial Primary-Selective Radial Loop-Primary Selective Secondary Selective Sparing Transformer Spot Network

Simple Radial System Simple, least costly Easy to coordinate No idle parts

Radial System

Primary and Secondary Radial

Loop Primary Radial Secondary

Loop Switching Substation Transformer

Loop Switching Pad Mount Transformer

Primary Selective Radial System Duplex or selector switch Spare primary incoming circuit Duration of outage from cable failure limited

Primary Selective Secondary Radial

Duplex Selector Switch

Selector Switch Single Structure

Secondary Selective System Normally operated as two electrically independent substations with tie breaker open Failure of either primary circuit affects only one bus Service restored by opening dead bus main and closing tie Operation can be made automatic Transformers not paralleled so fault currents similar to radial

Two-Source Primary Secondary Selective

Sparing Transformer System Alternative to Double-Ended Substations Single Common Backup Transformer Service restored by opening dead bus main and closing tie Operation can be made automatic Transformers not paralleled so fault currents similar to radial Location of substations limited (must be clustered)

Sparing Transformer

Spot Network Transformers paralleled on the secondary side Uses network protectors If primary voltage fails, associated protector automatically opens Other protector remains closed No dead time on bus, even momentarily Upon voltage restoration automatically synchronizes and re-closes Improved voltage regulation Secondary fault current increased

Spot Network

Primary Equipment Air Terminal Chamber Metal-Clad Switchgear Circuit Breaker and Relays Metal-Enclosed Switchgear Switch and Fuse Others (Reclosers and Interrupters)

Metal-Clad Switchgear Defined in ANSI C37.20.2 as metal enclosed power switchgear Removable (draw-out) type switching and interrupting devices Connect and disconnect position Major parts of the switchgear enclosed by grounded metal barriers for compartmentalization Automatic shutters that cover primary stabs or studs All primary bus conductors and connections covered with insulation material throughout

Protective Relays (ANSI Device Numbers) 27 - Undervoltage 47 - Phase sequence 49 - Thermal overload 50 - Instantaneous 51 - Time overcurrent 59 - Overvoltage 63 - Sudden pressure 67 - Directional overcurrent 86 - Lockout 87 - Differential

Metal-Enclosed Interrupter Switchgear Defined in ANSI C37.20.3 as metal-enclosed power switchgear Interrupter switches Power fuses (current limiting or non-current limiting) Bare bus and connections Instrument transformers Control wiring and accessory devices

Power Fuse Coordination Expulsion Inverse-time Easier to coordinate Current Limiting Steep straight line More difficult to coordinate

Pad Mounted Transformer Switching and Fusing LBOR Switch Oil Interruption Rated 200, 300, 400 A Isc = 12 ka Current Limiting and Expulsion Fuses Limited Sizes

Transformers

Unit Substation Transformers 112.5 through 20,000 kva Maximum 69 kv Primary Maximum 34.5 kv Secondary Bushings wall mounted Part of a substation lineup Can be custom designed to meet custom dimensions

Padmount Transformers Up to 5,000 kva Maximum 34.5 kv Primary Maximum 600 V Secondary Weather resistant high and low voltage compartments Tamper-resistant Design No Fan Cooling Available 6

Network Transformers 300-2500 kva Maximum 34.5 kv Primary Maximum 600 V Secondary Used in areas of high load density Designed for use in a secondary network system in either subway or vault applications.

Dry Versus Liquid Transformers Dry No fluid to spill or burn Cost is higher than oil Resistant to moisture and chemical contamination Minimum maintenance UL Listing is available Liquid Lowest purchase price Hermetically sealed tank for harsh environments Lowest losses per purchase dollar Best balance of design properties- dielectric, thermal, and cost UL Listing is available

Liquid Filled Technology Benefits Lowest Purchase Cost Lowest Loss Per Purchase Dollar Ability to operate in adverse conditions Excellent Dielectric Properties Smaller Footprint Better losses Options available for Safety- Related and Environmentally Sensitive Applications

Dry Type Technology Benefits Environmentally Safe Non-flammable Minimal Maintenance Coordination Flexibility Higher Fan Cooled Rating

Comparison of Transformer Costs Liquid Filled Transformers Mineral Oil (Outdoor) 1.00 Vegetable Oil (Indoor/Outdoor) 1.20 Silicone (Indoor/Outdoor) 1.35 Pad Mounted 5% Less than Substation Design Dry Type Transformers Vacuum Pressure Impregnated 1.25 Vacuum Pressure Imp. - Epoxy 1.35 Cast Coil 1.55 to 2.0 Lower Temperature Rise 15% to 35% Outdoor Add 20%

Loss Evaluation I 2 R Losses = Total Losses (TL) - No Load Losses (NL) I 2 R Losses are proportional to the Load Factor Squared Load Factor = Actual Load kva/rated Base kva Operating Losses = No Load Losses + I 2 R Losses at the appropriate Load Factor

Loss Evaluation Example Losses in watts for a 1000 kva oil-filled transformer: 1,800 watts no load losses 15,100 watts full load losses Load losses are approximately 13,300 watts (15,100 1,800) At 0% load: 1,800 watts At 50% load: 1,800 watts + (13,300)(.5) 2 = 1,800 watts + 3,325 watts = 5,125 watts At 100% load: 1,800 watts + 13,300 watts = 15,100 watts At 110% load: 1,800 watts + (13,300)(1.1) 2 = 1,800 watts + 16,093 watts = 17,893 watts

Auxiliary Fan Cooling Liquid filled transformers Fan cooling - 15% (750 kva to 2000 kva) Fan cooling - 25% (2500 kva and above) Dry type transformers Fan cooling - 33% (All ratings)

Environment Maximum altitude 1000 m (3300 feet) Rating reduced 0.3% to 0.5% for each 100 m (330 feet) above that altitude Indoor and outdoor designs available Ambient 30 degree C (86 degree F) average over 24 hours 40 degree C (104 degree F) maximum

Transformers - Liquid Filled Insulation systems (Oil, Silicone, Vegetable Oil) Temperature rise 55 degree C 65 degree C Efficiency - 99% Overload capacity - ANSI C37.92 Auxiliary devices Temperature gauge Liquid level gauge Pressure vacuum gauge Sudden pressure relay Pressure relief device

Transformers - Dry type Insulation systems Varnish Polyester Silicone Epoxy Design types Dip and bake VPI Cast coil Insulation classes Class H 220 degree C Class F 185 degree C Class B 150 degree C

Transformers - Dry Type Temperature rise 150 degree C 115 degree C 100 degree C (epoxy) 80 degree C Efficiency 97% to 98% (typical) 99% (low temperature rise) Overload capacity - ANSI C57.96 Auxiliary devices Temperature gauge

Secondary Neutral Grounding Solid Grounding Impedance Grounding Low resistance High resistance Reactance

Secondary Equipment Air terminal chamber Busway Low voltage switchboard Molded Case Circuit breakers Metal-Enclosed Switchgear Low voltage Power circuit breakers

Low-Voltage Switchboards (UL891) Versus Metal-Enclosed Switchgear (UL1558)

Paralleling Switchgear

Low-Voltage Switchboards (UL891) Versus Metal-Enclosed Switchgear (UL1558) Molded Case Circuit Breakers (UL489) Insulated Case Circuit Breakers (UL489) Power Circuit Breakers (UL1066) Front Access or Rear Access Drawout or Fixed Mounted Manually or Electrically Operated

Low-Voltage Circuit Breaker Types Molded Case Circuit Breakers Tested in accordance with UL489 & Nema AB-1 Open Air Test - Rated @ 80% (Optional 100%) Over Toggle Mechanism Sealed Case - Not Maintainable Applied in Switchboards/Panelboards Insulated Case Circuit Breakers Tested in accordance with UL489 & Nema AB-1 Open Air Test - Rated @ 80% or 100% 2-Step Stored Energy Mechanism Sealed Case - Not Fully Maintainable Applied in Switchboards Power Circuit Breakers Tested in accordance with UL1066 & ANSI C37 Tested in the Enclosure - Rated @ 100% 2-Step Stored Energy Mechanism Open Access - Fully Maintainable Applied in Metal-Enclosed Draw-out Swgr

Low-Voltage Circuit Breaker Typical Ratings Molded Case Circuit Breakers Frame Size: 100 through 3000 ampere Interrupting: 10/35/65/100 ka @ 480 Volts Limiters Available: 200 kaic Instantaneous: 10-13X Frame Rating @ various X/R Insulated Case Circuit Breakers Frame Size: 400 (800) through 5000 ampere Interrupting: 65/85/100 ka @ 480 Volts Limiters Not Normally Available Inst./Short Time: 25/35/65 ka @ various X/R Power Circuit Breakers Frame Size: 800 through 5000 ampere Interrupting: 65/85/100 ka @ 600 Volts Limiters Available: 200 kaic Short Time: 35/65/85/100 ka @ X/R of 6.6

TCC with Power Circuit Breakers MCCB- 200A MCCB- 50A PCB- 2400A PCB- 800A PCB 2400 amp 480V, Microprocessor Trip, LS Frame size: 3200 A Sensor: 2400 LTPU: 1.0 f(s) = 2400 amp STPU: 5.0 f(s) = 12000 amp LTD: 7.00 sec. STD:.3 sec. No Instantaneous Trip PCB 800 amp 480V, Microprocessor Trip, LS Frame size: 800 A Sensor: 800 LTPU: 1.00 f(s) = 800 amp STPU: 5.0 f(s) = 4000 amp LTD: 7.00 sec. STD:.1 sec. No Instantaneous Trip MCCB 200 amp 480V, Microprocessor Trip, LSI Frame size: 250 A Trip: 200 A Inst. PU: 10.0*T = 2000 A MCCB 50 amp 480V, Thermal-Magnetic Trip Frame size: 100 A Trip: 50 A Inst. PU: Non adjustable

Maintenance - MCCBs and ICCBs Enclosed design requires little maintenance Terminal connections and trip units tightened to the proper torque values Inspect conductors Visually inspect and operate periodically Replacement parts are not available Repair, refurbishment, or remanufacture not recommended - replace damaged breakers

Maintenance - PCBs Designed to be serviced Replacement parts are available (contacts, pole assemblies, arc chutes) Inspection and maintenance program is recommended Keep it dry, keep it clean, keep it tight

Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products