FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system



Similar documents
wireless alarm system reliable protection for small-size buildings

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Conventional Fire Detection and Extinguishant Control System Specification

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Fire detection equipment

DTW Works Master Specification Version 2006

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

SECTION DETECTION AND ALARM

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Domonial, le Sucre. Easy to Use Intruder Detection Systems

Triple Waveband Infra-Red Flame Detection

Question Shall the Tender include installation of the central server application on a redundant server?

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

S100. GSM House Alarm System.

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

GE Security. FHSD Monitor / Web Server user manual

FAAST. Fire Alarm Aspiration Sensing Technology

AlarmSense 2-wire detection and alarm system. Product Guide

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

SECTION FIRE ALARM AND DETECTION SYSTEMS

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Access control designed simply for you

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MOBILE CALL GSM alarm system

Temperature & Humidity SMS Alert Controller

Network Time Accessories LED CLOCK. (for NTP Synchronization)

Security Systems Intrusion Alarm

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Intrusion. IC60 security meets design. Answers for infrastructure.

HERZ-Thermal Actuators

CAN/ULC-S Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Remote Monitoring and REC 501 Control Unit Product Guide

VL Touchscreen Alarm. A Brilliantly Crafted Touchscreen Security System that Revolutionizes Your World

Security with you in mind. As your needs change, NetworX security systems grow with you.

NX-10-V3 wireless system. To wire or not to wire?

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

USB-500/600 Series Low-Cost Data Loggers and Accessories

Installation Manual for D1110 DigiCom2

INTRUSION DETECTION SYSTEM Section

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

RRV934. Multi-controller. Synco living

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

JAWAHARLAL NEHRU UNIVERSITY

A project to optimise quality and energy efficiency must include metering

HyperAccess Access Control System

Technical Information RIA14

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

MINERVA MX MX Virtual Multi-Sensor Detectors

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Intelligent GSM Auto-Dial Alarm System

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

NATIONAL FIRE ALARM AND SIGNALING CODE

Setting Up the Cisco Unified IP Phone

HWg-STE HWg-STE PoE MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

conventional system operation

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

NetworX. Security with you in mind. As your needs change, NetworX security systems grow with you.

Digital inductive conductivity transmitter

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

System off. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

PLAN REVIEW GUIDE FOR FIRE ALARM

GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

How To Control A Knx System From Your Touch Panel

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Fire Alarm Control Panel. Family. Operating Manual

Transcription:

FIRE ALARM SYSTEM reliable fire detection and alarm signalling system

Satel fire alarm devices allow to implement reliable and modern systems responsible for fire safety. A combination of 20-year experience in an electronic security systems industry with an advanced manufacturing technology enabled to design and put into mass production a number of devices which have a lot more features than products in their class available in the market so far. Full compatibility with the requirements of EN54 standards enables to use of SATEL devices in any case when required by specified regulations. Functionality of CSP-200 and CSP-100 series fire alarm panels CSP-200 and CSP-100 fire alarm panels are intended for implementation of complex fire alarm signalling systems in small and medium buildings. CSP 100 range of panels offer all the most important functions required for certified fire signalling systems, ensuring easy installation and maintenance. The 200 series is additionally fitted with readable LCD display, thanks to which not only programming and periodical maintenance, but also everyday operation are considerably easier. The 200 series panels offer the most advanced features amongst conventional fire signalling systems. Wide range of necessary accessories SATEL s product range of fire alarm signalling devices is truly complex. Therefore, besides the panels and associated devices, the range of products includes automatic fire detectors (smoke, heat, multi-sensor), manual call points and signalling devices. The offer is supplemented by auxiliary accessories, such as local fire alarm indicator or industrial base for automatic detectors, which makes installation of the detectors with the use of conduit pipes easier.

FIRE ALARM SIGNALLING SYSTEM schematic diagram of the system PSP-208 repeater panel compatible with CSP-208 Virtual PSP virtual repeater panel communicating over TCP/IP Ethernet CSP-ETH TCP/IP Ethernet communication module CSP-208 8-zone, conventional fire alarm panel SPP-100 acoustic fire alarm signalling device, low base SPP-101 acoustic fire signalling device, high base DRP-100 point, optical (scattered light) smoke detector, intended for visible smoke detection WZ-100 external fire alarm indicator for automatic fire detectors ROP-100/EU conventional manual fire alarm for internal use DCP-100 point, rate-of-rise/fixed temperature heat detector WZ-100 external fire alarm indicator for automatic fire detectors ROP-101/EU conventional manual call point for outdoor use DMP-100 multi-detector point sensor, optical smoke and heat detection WZ-100 external fire alarm indicator for automatic fire detectors PDB-100 industrial spacer for DB 100 detector base DB-100 DB-100 detector base DRP fire detector DCP, DMP fire detector

CSP 200 series Fire alarm control panels LCD display making everyday operation, maintenance and programming easier 8 detection zones in CSP-208 model, 4 detection zones in CSP-204 model support for remote repeater panel and virtual repeater panel 4 inputs with functionality defined by an installer 8 (CSP-208) / 4 (CSP-204) outputs programmed by an installer, allowing the communication with other systems operation of fire alarm and fault transmission devices built-in back-up power supply using single 12 V battery have EC Conformity Certitficate no 1438/CPD/0317 CSP 100 series Fire alarm control panels 8 detection zones in CSP-108 model, 4 detection zones in CSP-104 model support for remote repeater panel and virtual repeater panel 4 inputs with functionality defined by an installer 8 (CSP-108) / 4 (CSP-104) outputs programmed by an installer, allowing the communication with other systems operation of fire alarm and fault transmission devices built-in back-up power supply using single 12 V battery have EC Conformity Certitficate no 1438/CPD/0317 Repeater panels (PSP 200 and 100 series) Remote repeater panels for fire alarm control panels ability of full system operation from a remote place (up to 1 km) system operation in the same way as for front CSP panel built-in back up power supply using single 12 V battery Virtual PSP Virtual repeater panel for system state visualisation visualisation of alarms from individual zones monitoring of current faults list indicating of current disablement and test conditions Effective fire detection

fire signalling CSP-ETH Communication module for a virtual panel compatibility with CSP-200 and CSP-100 series control panels compatible with PSP-200 and PSP-100 repeater panels automatic IP configuration via DHCP powered directly by control panel or repeater panel ROP-100/EU ROP-101/EU Manual call point hermetic enclosure for outdoor installation (ROP-101/EU) mechanical actuation memory LED actuation indicator restore after actuation with a special key have EC Conformity Certitficate no 1438/CPD/0342 ROP-BT Junction box intended for use with ROP-100 manual call points PE terminal for connection of the cable shield additional terminals for connection of line wires SPP-100 SPP-101 Acoustic signalling device hermetic enclosure for outdoor installation (SPP-101) selection from 32 signalling sounds ability of triggering of two different sounds sound volume adjustment have EC Conformity Certitficate no 1438/CPD/0343 WZ-100 Alarm indicator optical signalling with use of LED diode aesthetic appearance easy installation at an early stage allows to limit its

for your safety DCP-100 Point, rate-of-rise/fixed temperature heat detector thermal sensor with A1R characteristic, in accordance with EN54-5 easy installation of the detector on the base operation of a local external alarm indicator have EC Conformity Certitficate no 1438/CPD/0316 DRP-100 Point optical smoke detector unique Swirl chamber for improved smoke sensitivity detected test fires: TF2-TF5 and TF8 precise filter made of stainless steel signalling of measurement chamber contamination easy installation of the detector on the base operation of a local external acting indicator have EC Conformity Certitficate no 1438/CPD/0340 DMP-100 Point optical smoke and heat detector unique Swirl chamber precipitating smoke detection detected test fires: TF1-TF6 and TF8 thermal sensor with A1R characteristic, in accordance with EN54-5 precise filter made of stainless steel signalling of measurement chamber pollution easy installation of the detector on the base operation of a local external acting indicator have EC Conformity Certitficate no 1438/CPD/0341 DB-100 Detectors base compatible with DMP-100, DRP-100 and DCP-100 detectors readable descriptions making connection in installation easier possibility of application of 10x20 conduit pipes PDB-100 Industrial spacer for DB-100 socket easier mounting of DB-100 socket in installation with conduit pipes possibility of application of PG-16 glands and Ø16 conduit pipes external brackets enabling installation without perforation of the bottom effects considerably

Advantages for designers CSP fire alarm control panels were designed in order to make designers and the system installers work easier. Aesthetic control panel allows installing the switchboard even in a place where it will be exposed without a fear of disturbance of the inside design harmony. An interesting option might be to use the remote repeaters that allow for full system operation, for instance in the security centre of the building, remote from the physical control panel location. An additional asset of CSP switchboards is a virtual panel, which allows to check remotely the fire signalling alarm system state from any place in the world with use of INTERNET network. Besides this, CSP control panels implement correlation of A and B zones in accordance with a standard, which reduce the chances false alarms, even when installed in harsh environment. Moreover, enhanced configurability of programmable inputs and outputs allows for cooperation of CSP system with other security systems in a building I&HAS, access control or fire fighting devices. Advantages for installers All the CSP series control panels were initially configured in order to minimize necessary system programming. A manufacturer s setup allows to gain a working system which requires only connecting of the devices to appropriate panel inputs and outputs. In case of need for changes to this setup, the system can be programmed with use of both the panel buttons as well as a special PC software. Thanks to a possibility of programming functions of additional inputs and relay outputs, CSP 100 and 200 series control panels allow to perform additional actions going beyond local signalling of fire detection. For instance, cooperation with access control system or public address systems is possible. Advantages for maintenance staff CSP alarm control panels are characterized by numerous well thought out solutions, thanks to which a periodical inspection and the maintenance is comfortable and intuitive. For example, access to a service mode is protected by a password which is entered with use of the switchboard operation buttons. Thanks to this, there is no need for opening the panel enclosure in order to change the control panel configuration. Moreover, the detectors test function one person tests easier, thus minimizing the number of people necessary to efficient verification of the system performance. Additionally, the use of a single standard 12 V battery accelerates the diagnostic tests and reduces cost of its replacement, which is beneficial for reduction of general system maintenance cost. Great help are also advanced tools which allow to evaluate individual functional system blocks, thanks to which identification of potential faults is easy and quick. It is also worth to mention a enhanced event memory with a possibility of exporting data to popular formats (e.g. CSV), which make archiving the register of the whole system functioning easier.

Characteristics CSP 200 and 100 series 200 series 100 series CSP-208 CSP-204 CSP-108 CSP-104 Number of supervision zones 8 4 8 4 Number of alarm outputs 2 2 2 2 Outputs to Fire Alarm transmission devices/fault transmission devices yes/yes yes/yes yes/yes yes/yes Number of programmable inputs 4 4 4 4 Number of programmable outputs 8 4 8 4 Display facilitating service yes yes no no Compatibility with remote repeater panel yes yes yes yes Compatibility with a virtual panel yes * yes * yes * yes * AUX (12-18 V) power supply yes yes yes yes AUX24 (24 V) power supply yes yes yes yes Event memory capacity 8999 8999 8999 8999 Alarm meter capacity 9999 9999 9999 9999 * The function requires connection of CSP-ETH module Over 20 years of experience Since establishment in 1990, every year of SATEL company activity means marketing new products intended for protection of people and property. You can find in our offer a wide range of devices and accessories used in alarm systems, access control systems, fire signalling systems as well as equipment intended for companies dealing with monitoring of these systems. Strategic investments in new technologies and innovative solutions provide a leading position in the market to the company. Dynamic company growth and expansion of products range are possible thanks to trust that clients put in our solutions. Accurate recognition of the customers needs and requirements is one of our company s success pillar. Our mission is to provide our individual and institutional clients feeling of safety and rising standards of people and property protection. Our staff make every effort to ensure that SATEL products offer using comfort and rise quality of life. Schuberta 79, 80-172 Gdansk, POLAND tel. +48 58 320 94 00; fax +48 58 320 94 01 e-mail: trade@satel.pl (IND_0913) www.satel.eu