NEW YORK CITY FIRE DEPARTMENT



Similar documents
NEW YORK CITY FIRE DEPARTMENT

Program No Section Heading

Winnipeg Fire Department Fire Prevention Branch

General Fire Code Requirements Within Commercial Tenant Spaces

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

PLAN REVIEW GUIDE FOR FIRE ALARM

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

City of Bettendorf Fire Alarm System Requirements

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Fire Alarm System Plans Review Checklist Property location Date of Review

2007 ICC FINAL ACTION AGENDA

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rules

CHAPTER 9 FIRE PROTECTION SYSTEMS

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

EXHIBIT A SCOPE OF WORK

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

HERNANDO COUNTY FIRE ALARM GUIDELINES

FIRE ALARM SYSTEM RECORD OF COMPLETION

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Fire Alarm Systems Requirements by Occupancy Type

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Life Safety Code Enabling References

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Mobile Fire Rescue Department Bureau of Fire Prevention

Module 5. Fire and Emergency Alarm System Part I- Basics

NYC FIRE CODE GUIDE CODE DEVELOPMENT UNIT BUREAU OF FIRE PREVENTION

FIRE PROTECTION SYSTEMS

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

A. Fire Protection Plan. B. Access and Parking

Overview of Hotel Fire Safety Requirements

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Environment of Care Fire Safety Management Plan 2014

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Georgia State Amendments to the International Fire Code (2012 Edition)

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Bold items are particular to the City of Euless

1.0 General. Inspection, Testing, and Maintenance 1 of 8

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Building Permit, Fire Inspection and Operating Permit Fee Schedule

PERMIT & SERVICE FEE SCHEDULE

FDNY C14 Certificate of Fitness Quiz

F.Y.I. Specifying Fire Protection Systems Using Division 13

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Fire Alarm and Protection Impairment Policy and Procedures

FIRE PROTECTION SYSTEMS

FIRE PROTECTION SYSTEMS

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Ethanol Vehicle and Infrastructure Codes and Standards Citations

FIRE PROTECTION SYSTEMS

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

NATIONAL FIRE ALARM AND SIGNALING CODE

OREGON FIRE CODE Interpretations and Technical Advisories

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Chapter 9 Fire Protection Systems

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Firefighter Review. Instructor Guide

An inventory of hazardous materials used in your workplace will prove useful.

Fire Safety Plan University Stadium

FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE

Module 4, Lesson 12 Fire Alarm Systems

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

WHEN IS A PERMIT REQUIRED?

Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems

University Design Standard. Fire Alarm Systems

SECTION THREE CONSTRUCTION CODES

FIRE PROTECTION SYSTEMS

FIRE SAFETY PLAN FOR KITCHENER, ONTARIO

Automatic Fire Sprinkler Submittal Requirements

Inspection, Testing and Maintenance

FIRE PROTECTION SYSTEMS

Transcription:

NEW YORK CITY FIRE DEPARTMENT AIA NYC CODE COMMITTEE OVERVIEW OF NEW YORK CITY FIRE CODE OCTOBER 22, 2009 JULIAN BAZEL Counsel to the Department JAMES HANSEN Director of Code Revision

NYC MODEL CODE INITIATIVE Mayor s Advisory Commission on Model Codes 2003 report recommended adoption, with NYC amendments, of model codes c published by International Code Council, a national organization of state and municipal code officials from jurisdictions that have adopted the codes, including New York State (in 2003) Advantages of Model Codes 3 year ICC code development process Focus attention on new technology and safety concerns Make New York City code requirements more transparent 2

NYC BUILDING CODE REVISION PROJECT New Construction Codes enacted by Local Law Nos. 33/2007 and 8/2008 Effective July 1, 2008; grace period until July 1, 2009 Extensive cross-references references between Construction Codes and Fire Code 3

NYC FIRE CODE vs NYC BUILDING CODE Building Code (Title 28 of NYC Administrative Code) Design and construction of buildings, including design requirements for structure, means of egress, and building fire safety systems (sprinkler systems, standpipe systems, fire alarm systems) Fire Code (Title 29 of NYC Administrative Code) Operation and maintenance of buildings and fire safety systems Emergency planning and preparedness (fire safety and evacuation plans and emergency action plans) Regulation of hazardous materials, including design and installation of systems and equipment Regulation of businesses and activities involving fire safety concerns (e.g. open flames and torch operations) 4

FDNY FIRE CODE REVISION PROJECT NYC Fire Code developed by FDNY based on 2003 ICC International Fire Code. Technical Committee (FDNY personnel) review Advisory Committee (outside stakeholder) review Managing Committee oversight FDNY Code Revision Unit/Legal review NYC Law Department review Publication of Final Draft (December 2007) Public Forum - December 20, 2007 City Council Intro and Committee hearings Enactment of New York City Fire Code Local Law No. 26 of 2008 signed on June 3, 2008 Effective Date: July 1, 2008 FDNY rule repeal and repromulgation (ongoing) 5

APPROACH TO FIRE CODE REVISION Maintain existing jurisdiction between FDNY and Department of Buildings (DOB). Eliminate from Fire Code building design and construction provisions. Maintain current FDNY enforcement mechanisms and procedures (ECB Notice of Violation, Violation Order and Criminal Court Summons), as set forth in NYC Administrative Code Title 15. Adhere to IFC organization. Undertake to improve consistency of terminology. 6

APPROACH TO FIRE CODE REVISION (cont d) Maintain standards at least as strict as Fire Prevention Code, unless lesser standard determined to be safe due to other requirements, improved technology or other considerations. Evaluate new requirements, balancing fire safety with burdens on property owners, businesses and other regulated entities. Generally, apply design and installation requirements prospectively (to new and substantially altered facilities) and operational and maintenance requirements retroactively (to both new and existing facilities). 7

ORGANIZATION OF NYC FIRE CODE The organization of the NYC Fire Code mirrors that of the IFC, which is organized by type of material, operation and/or facility. 45 Chapters 117 Referenced Standards (listed in Chapter 45) 2 Appendices (Fees and Referenced Standard Modifications) 8

NYC FIRE CODE TABLE OF CONTENTS CHAPTER 1. ADMINISTRATION CHAPTER 2. DEFINITIONS CHAPTER 3. GENERAL PRECAUTIONS AGAINST FIRE CHAPTER 4. EMERGENCY PLANNING AND PREPAREDNESS CHAPTER 5. FIRE OPERATIONS FEATURES CHAPTER 6. BUILDING SERVICES AND SYSTEMS CHAPTER 7. FIRE-RESISTANCE RESISTANCE-RATED RATED CONSTRUCTION CHAPTER 8. INTERIOR FURNISHINGS, DECORATIONS AND SCENERY CHAPTER 9. FIRE PROTECTION SYSTEMS CHAPTER 10. MEANS OF EGRESS CHAPTER 11. AVIATION FACILITIES AND OPERATIONS 9

NYC FIRE CODE TABLE OF CONTENTS (cont d) CHAPTER 12. DRY CLEANING CHAPTER 13. COMBUSTIBLE DUST-PRODUCING OPERATIONS CHAPTER 14. FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION CHAPTER 15. FLAMMABLE FINISHES CHAPTER 16. FRUIT AND CROP RIPENING CHAPTER 17. FUMIGATION AND THERMAL INSECTICIDAL FOGGING CHAPTER 18. SEMICONDUCTOR FABRICATION FACILITIES CHAPTER 19. LUMBER YARDS AND WOOD WASTE MATERIALS CHAPTER 20. MANUFACTURE OF ORGANIC COATINGS CHAPTER 21. INDUSTRIAL FURNACES CHAPTER 22. MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES 10

NYC FIRE CODE TABLE OF CONTENTS (cont d) CHAPTER 23. HIGH-PILED COMBUSTIBLE STORAGE CHAPTER 24. TENTS AND OTHER MEMBRANE STRUCTURES CHAPTER 25. TIRE REBUILDING AND TIRE STORAGE CHAPTER 26. WELDING AND OTHER HOT WORK CHAPTER 27. HAZARDOUS MATERIALS GENERAL PROVISIONS CHAPTER 28. AEROSOLS CHAPTER 29. COMBUSTIBLE FIBERS CHAPTER 30. COMPRESSED GASES CHAPTER 31. CORROSIVE MATERIALS CHAPTER 32. CRYOGENIC FLUIDS CHAPTER 33. EXPLOSIVES, FIREWORKS AND SPECIAL EFFECTS CHAPTER 34. FLAMMABLE AND COMBUSTIBLE LIQUIDS CHAPTER 35. FLAMMABLE GASES 11

NYC FIRE CODE TABLE OF CONTENTS (cont d) CHAPTER 36. FLAMMABLE SOLIDS CHAPTER 37. HIGHLY TOXIC AND TOXIC MATERIALS CHAPTER 38. LIQUEFIED PETROLEUM GASES CHAPTER 39. ORGANIC PEROXIDES CHAPTER 40. OXIDIZERS CHAPTER 41. PYROPHORIC MATERIALS CHAPTER 42. PYROXYLIN PLASTICS CHAPTER 43. UNSTABLE (REACTIVE) MATERIALS CHAPTER 44. WATER-REACTIVE REACTIVE SOLIDS AND LIQUIDS CHAPTER 45. REFERENCED STANDARDS APPENDIX A. FEES APPENDIX B. REFERENCED STANDARD MODIFICATIONS 12

NYC FIRE CODE vs FORMER CODE First comprehensive revision since Fire Prevention Code enacted almost 100 years ago. Not radical departure more comprehensive and detailed Former Fire Prevention Code strict in many areas, but lagging behind national standards in others. 13

NYC FIRE CODE vs FORMER CODE (cont d) Enhanced safety of general public Expanded fire safety and evacuation plan requirements Periodic testing and inspection for sprinkler, standpipe and fire alarm systems (NFPA standards) Fire apparatus access roads More comprehensive regulation of hazardous materials More comprehensive regulation of special effects Enforcement of industry standards 14

NYC FIRE CODE vs FORMER CODE (cont d) Enhanced firefighter/ emergency responder safety Regulation of toxic materials that are not flammable or combustible Rooftop access and obstructions Construction site fire safety manager and pre-fire plan 15

NYC FIRE CODE vs FORMER CODE (cont d) Lawfully existing facilities and conditions on effective date of Fire Code allowed to continue under prior applicable laws, rules and regulations, with certain exceptions (FC102.3 and R102-01) 01) Design and installation document requirements listed in FC 105.4 for convenient reference, referenced in Building Code Operational and maintenance requirements applicable to new and existing facilities (new permits and certificates of fitness required by 7/1/09) 16

FIRE CODE TERMINOLOGY Complete listing of definitions in Chapter 2, with cross-references references to individual chapters Design/installation/operation/maintenance Material/operation/facility Hazardous material/combustible material/ combustible waste Manufacturing/storage/handling/use/ transportation (sale/possession) of hazardous material 17

NYC FIRE CODE HIGHLIGHTS (CHAPTERS 1 AND 3) Chapter 1 (Administration) General maintenance provision (FC107) maintenance recordkeeping requirement (on premises or other approved location for 3 years, unless otherwise provided) Expeditor registration (FC116) (registered architects exempt) Modifications (FC104.8) Chapter 3 (General Precautions Against Fire) No Smoking at construction sites 18

NYC FIRE CODE HIGHLIGHTS (CHAPTER 4) Chapter 4 (Emergency Planning and Preparedness) Fire safety and evacuation plans extended to assembly occupancies and mercantile occupancies FSP Staff training (FC406) Additional fire safety and evacuation plan content Requirements for R-1 R 1 school and college dormitories FSD requirement Evacuation diagram on back of doors 19

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES FC 503 Fire Apparatus Access Roads (FAAR) Definitions Frontage space 30 x 30 area (from Building Code) accessible from a public street or FAAR adjoining main front entrance FAAR private road from public street to frontage space of building 20

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) 38 wide FAAR with certain exceptions below 34 wide FAAR by right where ZR 26-21 21 authorizes narrower streets in exchange for additional off-street parking, or by modification in Special Natural Area zoning districts 30 wide FAAR by right in Special Hillside Preservation zoning districts 30 wide FAAR by right for 5 sprinklered dwelling units 21

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) Reduced FAAR width by modification for 1 or 2 family dwellings (Group R-3) R set back from street (main front entrances to each dwelling unit 30-100 feet from street), if following criteria met: Impractibility (required FAAR > 20% of the width of the property). The driveway serving as FAAR only for single 1 or 2 family dwelling and no other non-accessory buildings. The height of the 1 or 2 family dwelling is not >35 feet above the grade plane (BC502.1). Dwelling has interconnected smoke alarms. Unobstructed 5-foot 5 foot access to the rear yard if the main front entrance to either of the dwellings is on side or rear of building (not directly accessible from the street or the driveway). 22

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) Reduced FAAR width by modification for 1 or 2 family dwellings (Group R-3) R set back from streets (main front entrance to each dwelling 100-150 150 feet from street), if following criteria met: All of the requirements set forth above for 30-100, 100, except that, in lieu of a driveway, at least 20 wide FAAR designed and constructed in compliance with FC503.1.1. Dwelling is protected throughout by a sprinkler system. 2 off-street street spaces for a one-family dwelling (3 for a two- family dwelling) on the premises, separate from the FAAR. No parking on FAAR and No Parking sign (FC503.7) at entrance to FAAR. Unobstructed frontage space. 23

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) Modification of FAAR width for 1 or 2 family dwellings (Group R-3) R set back >150 from street by special approval only. Turnarounds - Required for dead ends >150 up to 400 feet, unless all new buildings sprinklered. No Parking signs required when parking is restricted FDNY may develop restrictions for winding streets or where access problems 24

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) FC503.8.2 Sprinkler Requirements For Buildings on Public Streets of Substandard Width New buildings on public streets less than 38 in width to be protected throughout by a sprinkler system Alterations to buildings on public streets less than 38 in width to be protected throughout by a sprinkler system only when: 25

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) The cost of alterations to the building (excluding 1 and 2 family dwellings) exceeds Building Code 60% standard. Any change in the main use or dominant occupancy of the building, as determined by DOB (except restoration of a building to original 1 or 2 family use). An increase of more than 125% in the square footage of the floor area of a building (excluding attic, basement and cellar space). An alteration that increase the height of a combustible (non-fireproof) building from 35 or less above the grade plane, to more than 35 above the grade plane. 26

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) A one-family dwelling altered to a two-family dwelling, except where: the alteration involves converting a basement or cellar space to a separate dwelling unit, and the new basement or cellar dwelling unit is protected throughout by a sprinkler system; or the alteration does not involve converting a basement or cellar space to a separate dwelling unit and at least two lawful accessory off-street parking spaces are provided on the premises. 27

NYC FIRE CODE HIGHLIGHTS CHAPTER 5 FIRE OPERATIONS FEATURES (cont d) FC504.4 Rooftop Access and Obstructions Buildings 100 or less in height with flat roofs (20 ) Roof access - 6 wide openings for every 12 linear feet of accessible exposure Roof obstructions- clear path- 6 wide and 9 high Color coding of electric, natural gas, compressed gas and fuel oil piping (new and existing) Telecommunication transmitter markings - (new and existing) 28

NYC FIRE CODE HIGHLIGHTS CHAPTER 6 BUILDING SERVICES AND SYSTEMS FC604 Emergency Power Systems Adopts NFPA Standard 110 for emergency power system maintenance Written schedule for maintenance of emergency power systems Monthly test of transfer switches Monthly test of emergency power systems and automatic transfer switches under load condition at operating temperature for 30 minutes FC605.1 Abatement of electrical hazards Apply Electrical Code Table 210.21(B)(2) 15 amp rated circuit 12 amps maximum load 20 amp rated circuit 16 amps maximum load 29

NYC FIRE CODE HIGHLIGHTS CHAPTER 9 FIRE PROTECTION SYSTEMS Supervision Personal supervision by Certificate of Fitness holder during required inspection, testing or servicing of sprinkler, standpipe and fire alarm systems Building staff designated as impairment coordinator for out-of of-service fire protection system 30

NYC FIRE CODE HIGHLIGHTS CHAPTER 9 FIRE PROTECTION SYSTEMS Design and installation FDNY Certificate of Approval required for non- water fire extinguishing systems, fire alarm control panels, fire dept connections (R112-01) Removal of carbon dioxide fire extinguishing systems from normally occupied areas by 7/1/13 Maintenance Maintenance of sprinkler/standpipe systems (NFPA 25) Fire pumps Test weekly and flow test annually Maintenance of fire alarm systems (NFPA 72) Smoke control systems written maintenance schedule 31

CHAPTER 9 (cont d) SPRINKLER SYSTEM PERIODIC INSPECTION AND TESTING REQUIREMENTS (Excerpt from NFPA 25 Table 5.1) Component Gauges (dry, preaction,, and deluge systems) Control valves Alarm devices Gauges (wet pipe systems) Pipe and fittings Sprinklers Fire department connections Valves (all types) Alarm devices Main drain Gauges Sprinklers Requirement Frequency Weekly/monthly Weekly/monthly Quarterly Monthly Annually Annually Quarterly See NFPA 25 Table 12.1 Test Test Test Test Quarterly/semiannually Annually 5 years 50 years, and every 10 years thereafter 32

CHAPTER 9 (cont d) STANDPIPE SYSTEM PERIODIC INSPECTION AND TESTING REQUIREMENTS (Excerpt from NFPA 25 Table 6.1) Control valves Component Pressure regulating devices Piping Hose connections Cabinet Hose Hose storage device Alarm device Hose nozzle Hose storage device Hose Pressure control valve Pressure reducing valve Hydrostatic test Flow test Main drain test Requirement Test Test Test Test Test Test Test Test Test Frequency Weekly/monthly Quarterly Quarterly Quarterly Annually Annually Annually Quarterly Annually Annually 5 years/3 years 5 years 5 years 5 years 5 years Annually 33

CHAPTER 9 (cont d) WATER STORAGE TANK PERIODIC INSPECTION AND TESTING REQUIREMENTS (Excerpt from NFPA 25 Table 9.1) Component Condition of water in tank Water temperature Heating system Control valves Water level Air pressure Tank exterior Interior Check valves Temperature alarms High temperature limit switches Water level alarms Level indicators Pressure gauges Requirement Test Test Test Test Test Frequency Monthly/quarterly Daily/weekly Daily/weekly Weekly/monthly Monthly/quarterly Monthly/quarterly Quarterly 5 years/ 3 years 5 years Monthly Monthly Semiannually 5 years 5 years 34

CHAPTER 9 (cont d) FIRE ALARM SYSTEM PERIODIC VISUAL INSPECTION REQUIREMENTS (Excerpt from NFPA 72 Table 10.3.1) Component Control equipment, including fuses, lamps, LEDs,, and power supply Batteries Emergency voice alarm communications equipment Remote annunciators Alarm notification appliance Supervisory signal and waterflow initiating devices Other initiating devices (e.g. duct detectors, fire alarm boxes and smoke detectors) Interface equipment Central station transmitters Frequency Weekly, or annually if alarm, supervisory and trouble signals are monitored by a central station Monthly/semiannually Semiannually Semiannually Semiannually Quarterly Semiannually Semiannually Semiannually 35

CHAPTER 9 (cont d) FIRE ALARM SYSTEM PERIODIC TESTING REQUIREMENTS (Excerpt from NFPA 72 Table 10.4.3) Component Control equipment, including fuses, lamps, LEDs, interface equipment and power supply Engine-driven emergency generator Batteries Emergency voice/alarm communications equipment Remote annunciators Supervisory signal devices Water flow devices and valve tamper switches Other initiating devices (e.g. electromechanical releasing devices and fire alarm boxes) Conventional smoke detector smoke entry test Frequency Quarterly, or annually if alarm, supervisory and trouble signals are monitored by a central station Monthly Quarterly Semiannually Annually Smoke detector sensitivity See NFPA 72 Section 10.4.3.2. (Generally, at least 2 detectors on each initiating circuit every 2 years) Supervisory signal devices Waterflow devices and valve tamper switches Alarm notification appliances, including audible and visual devices Central station transmitters Monthly Annually Annually Annually. Quarterly Semiannually Annually Annually 36

NYC FIRE CODE HIGHLIGHTS (CHAPTERS 10, 26 AND 27) Chapter 10 (Means of Egress) Maintenance required, including door hardware, security devices, removal of snow and ice, and prevention of overcrowding Chapter 26 (Welding and Other Hot Work) Hot work responsible person Hot work program authorization Pre-hot work check list Chapter 27 (Hazardous Materials) Fire Department liaison for storage, handling and use of hazardous materials during emergency response 37

FDNY RULE PROMULGATION (TITLE 3 OF RULES OF CITY OF NEW YORK) All rules to be repealed and repromulgated 95% complete New numbering parallels FC organization Rules of interest Existing facilities and installations (R102-01) 01) Appeal procedures (R104-01) 01) Non-sequential floor numbering (R408-01) 01) 38

FDNY WEBSITE Internet Address: www.nyc.gov/fdny Quick links to Fire Code and FDNY Rules Complete text of Fire Code and new FDNY Rules Frequently Asked Questions Official interpretations of Fire Code and rules Interim guidelines Fire Code public inquiry form 39

40