H ARDWARE C ONSIDERATIONS



Similar documents
H ARDWARE C ONSIDERATIONS

Windows 2008 Server Installation

Proof Point: Example Clustered Microsoft SQL Configuration on the HP ProLiant DL980

Chapter 5 Cubix XP4 Blade Server

4-1-4 Serial ATA SATA. A. Intel ICH8R (1) SATA (1) SATA (2) BIOS SATA (3) RAID BIOS RAID (4) SATA (5) SATA

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Computer Setup (F10) Utility Guide Evo Desktop Family Evo Workstation Family

Computer Setup User Guide

2001 Acer Incorporation. All rights reserved. This paper is for informational purposes only. ACER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS

Cisco MCS 7825-H2 Unified CallManager Appliance

Cisco MCS 7845-I2 Unified Communications Manager Appliance

DD670, DD860, and DD890 Hardware Overview

Hardware & Software Specification i2itracks/popiq

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Mother Board Component

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

CyberGuard 5.2 Installation Guide

System Release Notes Express5800/320LB System Release Notes

TS500-E5. Configuration Guide

HP VMware ESXi 5.0 and Updates Getting Started Guide

Cisco NAC Appliance Hardware Platforms

HP Server tc2120 Network Operating System Installation Guide

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

Intel Matrix Storage Manager 8.x

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Minimum Hardware Specifications Upgrades

Intel Rapid Storage Technology

QuickSpecs. HP Smart Array 5312 Controller. Overview

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

SCSI device drivers are provided for the following operating systems: Microsoft Windows NT Server 4.0 Novell NetWare 5.1

Figure 1A: Dell server and accessories Figure 1B: HP server and accessories Figure 1C: IBM server and accessories

Intel RAID Controller Troubleshooting Guide

EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0

Express5800/320Lb System Release Notes

English. Configuring SATA Hard Drive(s)

Visual UpTime Select Server Specifications

Precio Bundle. Disponibilidad. Description. Número de Parte

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

QuickSpecs. HP Integrity cx2620 Server. Overview

Installation Guide. N5101A Baseband Studio PCI Card. Overview


Computer Components Study Guide. The Case or System Box

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

Phoenix SecureCore TM Setup Utility

BIOS Update Release Notes

Installation and Configuration Guide for Cluster Services running on Microsoft Windows 2000 Advanced Server using Acer Altos Servers

HP Recommended SMART Array Rebuilding/Restoring Techniques

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Out-of-box comparison between Dell and HP blade servers

85MIV2 / 85MIV2-L -- Components Locations

(AOpen reserves the right to revise all the specifications and information contained in this document which is subject to change without notice.

Annex 1: Hardware and Software Details

Installation Guide. APA-1460 SlimSCSI. PCMCIA-to-SCSI Host Adapter

Digi International: Digi One IA RealPort Latency Performance Testing

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

Disk-to-Disk Backup Solution

HP BUSINESS NOTEBOOK PC F10 SETUP OVERVIEW

v1 System Requirements 7/11/07

PC Workstation 2015 RAID Service Guide

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Sophos UTM Software Appliance

PCI ATA 133 RAID Controller Card. User Manual


QuickSpecs. HP ProLiant ML110 G2. Overview

McAfee Firewall Enterprise

C440GX+ System Event Log (SEL) Messages

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

Monthly Specification Update

RSA Security Analytics. S4 Broker Setup Guide

Ultra Thin Client TC-401 TC-402. Users s Guide

Microsoft Internet Information Server 3.0 Service Failover Using Microsoft Cluster Server

Referencia: Dell PowerEdge SC YMJ3J Nettó Ár: Db: 1 Tag Number: 37YMJ3J

Dell PowerEdge T110 II Systems. Owner s Manual. Regulatory Model E11S Series Regulatory Type E11S002

RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

Promise FastTrak 100-Lite RAID Controller

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures

Intel N440BX Server System Event Log (SEL) Error Messages

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

BIOS Award v6.00pg BIOS setup guidelines

Installing the Operating System or Hypervisor

Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

Chapter 5 Busses, Ports and Connecting Peripherals

Commonwealth of Virginia Virginia Information Technologies Agency GATEWAY DESKTOPS, NOTEBOOKS & SERVERS. Optional Use Contract

Serial ATA 2 Ports PCI Host

Running FileMaker Pro 5.0v3 on Windows 2000 Terminal Services

VIA Fedora Linux Core 8 (x86&x86_64) VT8237R/VT8237A/VT8237S/VT8251/CX700/VX800 V-RAID V3.10 Driver Installation Guide

HP ProLiant ML110 Server Network Operating System Installation Guide

Personal Systems Reference

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Transcription:

H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Compaq ProLiant ML370 G2 This document provides information on specific system hardware required for running Sidewinder firewall software on a Compaq ProLiant ML370 G2. This document is intended for Secure Computing customers who obtain the computer hardware for their firewall software from a supplier other than Secure Computing Corporation. You should read this document if you are responsible for evaluating, ordering, installing, or configuring system hardware for running Sidewinder firewall software. This document assumes you are familiar with PC hardware component terminology. The detailed set up and configuration guidelines section also assumes you are an experienced computer technician. Note: Use this guide in conjunction with the manufacturer s documentation included with your hardware package. Important:Make sure you read and understand the Known Issues section before purchasing this chassis. Contents Specific hardware supported................ page 2 Setup and configuration guidelines............ page 4 Known issues............................ page 8 Document Part Number: 86-0935761-C 1

Specific hardware supported Specific hardware supported This section defines the required and supported hardware components for installing Sidewinder software on a Compaq ProLiant ML370 G2. ANY SUBSITUTIONS WILL RESULT IN A CONFIGURATION NOT SUPPORTED BY SECURE COMPUTING. Important:This hardware configuration is supported for Sidewinder version 5.2.1 or higher. Table 1. SUPPORTED HARDWARE Hardware item, supplier, and description Quantity Supplier Part Number (P/N) Compaq ProLiant ML370 G2, 1.266 GHz, 256 MB RAM, 3.5" floppy drive, and CD-ROM 1 Compaq 188548-001 Compaq 17" monitor S720 1 Compaq 239286-001 Seagate 20/40 GB 4 mm DAT drive or Compaq 12/24 GB 4 mm DAT drive Compaq 18.2 GB disk drive 10,000 RPM or Compaq 18.2 GB disk drive 15,000 RPM 1 Seagate STD 2401LW or Compaq 295513-B22 1 4 Compaq 142673-B22 or Compaq 188122-B22 Compaq keyboard 1 Compaq 158649-001 Logitech 3-button mouse 1 Logitech 911455-0403 Optional redundant power supply 1 Compaq 255075-B21 Optional second 1.266 GHz processor 1 Compaq 231117-B21 Note: The embedded NIC and dual processors are supported on the Compaq ProLiant ML370 G2. Table 2. PCI SLOTS PCI Slots PCI 64-bit/66 MHz 2 PCI 64-bit/33 Mhz 4 2 Compaq ProLiant ML370 G2 Document Part Number: 86-0935761-C

Specific hardware supported Table 3. ADDITIONAL NETWORK CARD ADAPTERS AND SCSI RAID CONTROLLERS 10/100 MB Fast Network Adapters PCI - Single Port 3Com 3C905B-TX-NM 3C905B-Combo 3C905CX-TX-NM 3C980C-TXM Intel Pro 100+ Server Adapter, PILA8470B Pro 100S Server Adapter, PILA 8470C3 VPN Accelerator 3Com Typhoon 3CR990SVR95, 10/100 3CR990SVR97, 10/100 PCI - Multiple Port 3Com 3C982-TXM, Dual Port Compaq NC3134 Dual Port 10/100 NIC, PN 138603-B21 NC3135 Dual Port 10/100 upgrade module for NC3134, PN 138604-B21 Intel Entrada (Osicom) Ether Express Pro 100+ Server Adapter, PILA8472, Dual Port PILA8472C3, Dual Port FE-2404-TX, Quad Port Gigabit Network Adapters PCI - Fiber Intel Intel Pro/1000 Gigabit Server Adapter supports 1000 Base-SX Multi-Mode Fiber PWLA8490SX PWLA8490XF Compaq Compaq NC6134 Gigabit Fiber 174818-B21 PCI - Category 5 Twisted Pair Intel Intel Pro/1000 Gigabit Server NIC PWLA8490T PWLA8490XT Compaq Compaq NC7131 Gigabit Server Adapter 158515-B21 RAID Controllers PCI Adaptec Adaptec 2100S Document Part Number: 86-0935761-C Compaq ProLiant ML370 G2 3

Setup and configuration guidelines Setup and configuration guidelines This section defines how to verify that the Compaq ProLiant ML370 G2 hardware settings are correct for a Secure Computing firewall. These instructions supplement the manufacturer s Users Guide and Installation and Troubleshooting Guide. 1. Remove the top cover. Note: For the following steps, it will be advantageous to consult the Compaq Installation Guide for component locations. 2. Install a network card into any PCI slot. 3. The embedded NIC can be used for a network connection. 4. Locate the DAT drive and verify the model number. 5. Figure 1 and Figure 2 show the jumper and switch settings for the Seagate STD2401LW. FIGURE 1. DAT DRIVE JUMPER SETTINGS FOR STD2401LW 11-12 9-10 7-8 5-6 3-4 1-2 These jumpers are located on the back of the DAT drive. 1-2 = SCSI ID 0 jumper installed 3-4 = SCSI ID 1 jumper removed 5-6 = SCSI ID 2 jumper installed 7-8 = SCSI ID 3 jumper removed 9-10 = Parity checking jumper installed 11-12 = Terminator Power jumper removed Note:Jumpers 1 8 are set to specify a SCSI ID of 5. FIGURE 2. DAT TAPE DRIVE SWITCH SETTINGS FOR STD2401LW The switch pack is located on the bottom of the DAT drive. S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 S1 = Data compression (off) S9 = Wide narrow SCSI (on) S2 = SCSI DC control (off) S10 = Inquiry string support (on) S3 = Media recognition (on) S4 = Self test (on) S5 = Operating system configuration (on) S6 = Operating system configuration (on) S7 = Operating system configuration (on) S8 = Operating system configuration (on) 4 Compaq ProLiant ML370 G2 Document Part Number: 86-0935761-C

Setup and configuration guidelines 6. Figure 3 shows the jumper settings for the Compaq 12/24 GB DAT drive. FIGURE 3. DAT DRIVE JUMPER SETTINGS FOR COMPAQ 12/24 GB 4 MM DAT DRIVE, (PN 295513-B22) 1 2 3 4 5 6 7 8 These jumpers are located on the back of the DAT drive. 1 = SCSI ID 2 jumper installed 2 = SCSI ID 1 jumper removed 3 = SCSI ID 0 jumper installed 4 = Data compression disabled jumper installed 5 = Parity checking enabled jumper installed 6 = Reserved jumper removed 7 = Termination enabled jumper removed 8 = Terminator power jumper removed 7. Install the DAT drive into a 5.25 drive bay. Follow the instructions from the Compaq ProLiant ML370 G2 Setup and Installation Guide. 8. Connect the SCSI cable to the 4 mm DAT drive. 9. Connect the power cable to the DAT drive. 10. Remove the lowest cover from the Hot Swap Drive Bay. 11. Install the hard drive into the Hot Swap Drive Bay. 12. Re-install the top cover. 13. Connect the keyboard, mouse, and monitor to the Compaq ProLiant ML370 G2. Connect power cords to the monitor and Compaq ProLiant ML370 G2 and plug the power cord into an AC power source. 14. Turn on the power. 15. Press F9 to enter the ML370 G2 BIOS. Document Part Number: 86-0935761-C Compaq ProLiant ML370 G2 5

Setup and configuration guidelines 16. Verify the following settings: Table 4. BIOS SETTINGS Compaq ML370 G2 BIOS Settings System Options Operating system Solaris Serial Number Embedded Com Port A Embedded Com Port B Embedded LPT Port Integrated Diskette Controller NUMLOCK Power-On State Embedded NIC Port 1 PXE Support Diskette Boot Control Diskette Write Control xxxx COM 1; IRQ4 LPT 1; IRQ7 Off Read and Write PCI Devices PCI Embedded Compaq NC3163 10/100 Fast Ethernet NIC Port 1 IRQ: 10 PCI Embedded Compaq Advanced Server Management ASIC PCI Embedded PCI USB Controller PCI Embedded 64-Bit Dual Wide Ultra3 SCSI, Port 1 PCI Embedded 64-Bit Dual Wide Ultra3 SCSI, Port 2 PCI Embedded Compaq PCI Hot-Plug Controller IRQ: 5 IRQ: 11 IRQ: 3 IRQ: 10 PCI Slot 6 Ethernet Network Controller IRQ: 15 Standard Boot Order (IPL) Initial Program Loader IPL:1 IPL:2 IPL:3 CD-ROM Floppy Drive (A:) Hard Drive C: (See Boot Controller Order) Boot Controller Order Ctrl: 1 PCI Embedded 64-Bit Dual Wide Ultra3 SCSI, Port 2 Ctrl: 2 Ctrl: 3 Compaq Integrated PCI IDE Controller PCI Embedded 64-Bit Dual Wide Ultra3 SCSI, Port 1 More... 6 Compaq ProLiant ML370 G2 Document Part Number: 86-0935761-C

Setup and configuration guidelines Compaq ML370 G2 BIOS Settings Date and Time Automatic Server recovery Verify the date and time are set correctly. ASR Status ASR Time-out Thermal Shutdown 5 minutes Server Passwords Set Power-On Password Not required Set Admin Password Network Server Mode QuickLock Not required Advanced Options MPS Table Mode Auto Set Table Hot Plug Resources POST Speed Up POST F1 Prompt ROM Selection Use Current ROM Erase Non-Volatile Memory Set CPU Corrected Wake-ON LAN Advanced Memory Protection Default Fan Speed NMI Debug Button Standard ECC Support Normal 17. Exit and save the BIOS configuration. 18. Power down the Compaq ProLiant ML370 G2. 19. Ready to install Sidewinder! Please refer to your Sidewinder documentation. Document Part Number: 86-0935761-C Compaq ProLiant ML370 G2 7

Known issues Known issues The following are known issues on the Compaq ProLiant ML370 G2: If you have a Seagate STD2401LW 4mm DAT drive, you may be able to increase the data transfer rate. To change the drive to synchronous mode and achieve higher data transfer rates, add the following text to /etc/boot.local: -parm aic0 busted_v3sync=t5 To start the second processor add the following text to /etc/mp.config: extclk Save the change and then reboot. For the Compaq ProLiant ML370 G2 systems that contain a dual port or quad port NIC, note the following: If the network traffic slows or comes to a stop after enabling the second processor, verify the MPS table Mode in the ML370 G2 BIOS is set to Full Table Mapped. If Sidewinder reports "Unable to find floppy kernel on install media" followed by "fd0: no disk in drive", verify the following: The IDE controller is enabled. The CD-ROM drive is set-up to be the master device, or If the jumper on the CD-ROM is set to CS, verify the middle IDE cable connector is attached to the CD- ROM. Sidewinder does not support the Hot Swap feature on the two 64 bit PCI slots. Important: Opening the Hot Swap PCI slot release lever while Sidewinder is running causes a NMI error. NMI: port B(61)=a0<parity_error. Shutdown and turn the power off on the Compaq ProLiant ML370 G2 before adding/removing a PCI card. If the Hot Swap PCI slot release lever is opened with a NIC installed, time-outs will scroll on the screen. The following hardware is not supported in the Compaq ProLiant ML370 G2: The Compaq Smart Array 5i Raid Controller has not been tested on the ML370 G2 at this time. The Compaq Smart Array 431, 532, 5302, and 5304 PCI RAID Controllers are not supported. Secure Computing Corporation. Product names used within are trademarks of their respective owners. Copyright, 2002 Secure Computing Corporation. All rights reserved. 8 Compaq ProLiant ML370 G2 Document Part Number: 86-0935761-C