H ARDWARE C ONSIDERATIONS
|
|
|
- Diane Osborne
- 10 years ago
- Views:
Transcription
1 H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Dell Precision 530 This document provides information on specific system hardware required for running Sidewinder firewall software on a Dell Precision 530. This document is intended for Secure Computing customers who obtain the computer hardware for their firewall software from a supplier other than Secure Computing Corporation. You should read this document if you are responsible for evaluating, ordering, installing, or configuring system hardware for running Sidewinder firewall software. This document assumes you are familiar with PC hardware component terminology. The detailed set up and configuration guidelines section also assumes you are an experienced computer technician. Note: Use this guide in conjunction with the manufacturer s documentation included with your hardware package. Important: Make sure you read and understand the Known Issues section before purchasing this chassis. Contents Specific hardware supported page 2 Setup and configuration guidelines page 4 Known issues page 8 Document Part Number: A 1
2 Specific hardware supported Specific hardware supported This section defines the required and supported hardware components for installing Sidewinder software on a Dell Precision 530 system. ANY SUBSITUTIONS WILL RESULT IN A CONFIGURATION NOT SUPPORTED BY SECURE COMPUTING. Note: The embedded video chipset does not support Sidewinder s local graphical user interface (GUI). Use the Sidewinder GUI remotely from a Windows workstation. Important: This hardware configuration is supported for Sidewinder version or higher. Table 1. SUPPORTED HARDWARE Hardware item, supplier, and description Quantity Supplier Part Number (P/N) Dell Precision 530, 2.0 GHz, 256 MB RAM, CD- ROM drive, keyboard, 1.44 MB floppy drive or Dell Precision 530, 2.2 GHz, 256 MB RAM, CD- ROM drive, keyboard, 1.44 MB floppy drive Dell 17 monitor Dell 18 GB Ultra3, 10K RPM, SCSI hard drive or Dell 18 GB Ultra3, 15K RPM, SCSI hard drive Logitech 3-button mouse 1 Logitech Optional second 2.0 GHz processor Optional second 2.2 GHz processor Note: The embedded NIC and dual processors are supported on the Dell Precision 530. Table 2. PCI SLOTS PCI Slots PCI 32-bit/33 MHz 3 PCI 64-bit/66 MHz 2 2 Dell Precision 530 Document Part Number: A
3 Specific hardware supported Table 3. ADDITIONAL NETWORK CARD ADAPTERS AND SCSI RAID CONTROLLERS 10/100 MB Fast Network Adapters PCI Single Port 3Com 3C980C-TXM Intel Pro 100+ Server Adapter, PILA8470B Pro 100S Server Adapter, PILA8470C3 PCI - Multiple Port 3Com 3C982-TXM 10/100 Dual Port Server Adapter Intel Entrada (Osicom) Pro 100+ Server Adapter PILA8472, Dual Port PILA8472C3, Dual Port FE-2404-TX, Quad Port Gigabit Network Adapters PCI - Fiber Intel Intel Pro/1000 Gigabit Server Adapter supports 1000 Base-SX Multi-Mode Fiber PWLA8490SX PWLA8490XF PCI - Category 5 Twisted Pair Intel Intel Pro/1000 Gigabit Server Adapter PWLA8490T PWLA8490XT Raid Controllers PCI - Raid Controller Perc 3/DC Dell Document Part Number: A Dell Precision 530 3
4 Setup and configuration guidelines Setup and configuration guidelines This section defines how to verify that the Dell Precision 530 hardware settings are correct for a Secure Computing firewall. These instructions supplement the manufacturer s Users Guide and Installation and Troubleshooting Guide. 1. Connect the monitor, keyboard, mouse, and power cords. 2. Power on the system, and press F2 to enter the system setup routine. 3. Verify the following BIOS settings: Table 4. BIOS SETTINGS Dell Precision 530 BIOS Settings Time and Date Operating System Solaris Serial Number xxx Boot Sequence CD-ROM device Diskette Drive A: Hard drive C: Hard Drive Sequence System BIOS boot devices AIC-7899, A:00 SCSI HDD Integrated Devices Sound Network Interface Controller SCSI Controller 1394 Controller Mouse Controller USB Emulation USB Controller Serial Port 1 Serial Port 2 Parallel Port Mode I/O Address IDE Drive Interface PC Speaker Auto PS/2 378h Auto More... 4 Dell Precision 530 Document Part Number: A
5 Setup and configuration guidelines Dell Precision 530 BIOS Settings PCI IRQ Assignment (con) Intel Corp USB Adapter IRQ 14 Intel Corp serial bus IRQ 11 Intel Corp USB Adapter IRQ 10 Intel Corp Multimedia IRQ 11 Adaptec SCSI Adapter IRQ 14 3Com Corp Network Card IRQ 10 Texas Instruments IEEE1394 bus IRQ 9 System Security Password Status Unlocked System Password Setup Password Chassis Intrusion PXE BIOS Default Policy Keyboard NumLock Report Keyboard Errors Auto Power Remote Wake Up AC Power Recovery Fast Boot Suspend Mode OS Install Mode Not Not Deny Report Disabled S3 4. Exit and save the BIOS settings. 5. When the Adaptec screen appears, press Ctrl + A. 6. Verify or set the following parameters. 7. At the Configuration menu, verify the following settings for the Adaptec SCSI card. SCSI BUS Interface Definition: SCSI Controller ID set to 7 SCSI Controller Parity set to SCSI Controller Termination Document Part Number: A Dell Precision 530 5
6 Setup and configuration guidelines 8. At the Additional Options menu, select SCSI Device Configuration and verify or set the following: Table 5. SCSI DEVICE CONFIGURATION SETTINGS 0 7 SCSI Device ID Sync Transfer Rate Initiate Wide Negotiation YES YES YES YES YES YES YES YES Enable Disconnect YES YES YES YES YES YES YES YES Send Start Unit Command YES YES YES YES YES YES NO YES Enable Write Back Cache NO NO NO NO NO NO NO NO BIOS Multiple LUN Support NO NO NO NO NO NO NO NO Include in BIOS scan YES YES YES YES YES YES YES YES Table 6. SCSI DEVICE CONFIGURATION SETTINGS 8 15 SCSI Device ID Sync Transfer Rate Initiate Wide Negotiation YES YES YES YES YES YES YES YES Enable Disconnect YES YES YES YES YES YES YES YES Send Start Unit Command YES YES YES YES YES YES YES YES Enable Write Back Cache NO NO NO NO NO NO NO NO BIOS Multiple LUN Support NO NO NO NO NO NO NO NO Include in BIOS scan YES YES YES YES YES YES YES YES 6 Dell Precision 530 Document Part Number: A
7 Setup and configuration guidelines 9. Select Advanced Configuration Options from the Additional Options menu. Verify or set the following: Table 7. ADVANCED CONFIGURATION OPTION SETTINGS Advanced Configuration Options Reset SCSI Bus at IC Initialization Display <Ctrl + A> Message During BIOS Initialization Extended Int 13 Translation for DOS drives > 1GB Post Display Mode Verbose Options listed below have NO EFFECT if Int 13 support is disabled Host Adapter BIOS Support Removable Disks Under BIOS or Fixed Discs BIOS Support for Bootable CD-ROM Disabled 10. Exit and save the Adaptec card settings. 11. Ready to install Sidewinder! Please refer to your Sidewinder documentation. Document Part Number: A Dell Precision 530 7
8 Known issues Known issues The following are known issues on the Dell Precision 530: The embedded video chipset does not support Sidewinder's local graphical user interface (GUI). Use the Sidewinder GUI remotely from a Windows workstation. In the Dell Perc 3/DC Raid controller BIOS, verify the Adapter Emulation is set to: Mass Storage. Sidewinder will fail to detect a block size during the initial software load if the Adapter Emulation is not set. Secure Computing Corporation. Product names used within are trademarks of their respective owners. Copyright, 2002 Secure Computing Corporation. All rights reserved. 8 Dell Precision 530 Document Part Number: A
H ARDWARE C ONSIDERATIONS
H ARDWARE C ONSIDERATIONS for Sidewinder 5 firewall software Compaq ProLiant ML370 G2 This document provides information on specific system hardware required for running Sidewinder firewall software on
SCSI device drivers are provided for the following operating systems: Microsoft Windows NT Server 4.0 Novell NetWare 5.1
This section describes how to install and configure the Dell small computer system interface (SCSI) device drivers included with your Dell PowerEdge 1400 computer system. These device drivers are designed
Computer Setup (F10) Utility Guide Evo Desktop Family Evo Workstation Family
b Computer Setup (F10) Utility Guide Evo Desktop Family Evo Workstation Family Document Part Number: 215867-004 May 2002 This guide provides instructions on how to use Computer Setup. This tool is used
Phoenix SecureCore TM Setup Utility
Phoenix SecureCore TM Setup Utility Important information: We continually strive to bring you the latest and proven features and technologies. As part of our drive to continually improve our products modifications
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DG31PR, DG31PRBR (Standard BIOS) BIOS Version 0070 About This Release: February 8, 2010 Integrated Graphics Option ROM Revision: PXE LAN Option ROM Revision: Improved
Computer Setup (F10) Utility Guide Business PCs
Computer Setup (F10) Utility Guide Business PCs Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
Computer Setup User Guide
Computer Setup User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license. Intel is a trademark
BIOS Update Release Notes
PRODUCTS: D975XBX (Standard BIOS) BIOS Update Release Notes BIOS Version 1351 August 21, 2006 BX97510J.86A.1351.2006.0821.1744 Fixed issue where operating system CD installation caused blue screen. Resolved
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DG31PR, DG31PRBR (Standard BIOS) BIOS Version 0059 October 24, 2008 PRG3110H.86A.0059.2008.1024.1834 Added Fixed Disk Boot Sector option under Maintenance Mode. Fixed
AwardBIOS Setup Utility
AwardBIOS Setup Utility Modifications to the BIOS Setup settings should be performed by advanced users only. Setting items to incorrect values may cause your system to malfunction. Introducing BIOS Setup...2
CyberGuard 5.2 Installation Guide
CyberGuard 5.2 Installation Guide IN001-070 December 2003 Copyright 2003 by CyberGuard Corporation. All rights reserved. This publication or any part thereof may not be reproduced for any reason in any
Remote PC Guide Series - Volume 2a
Document Version: 2013-03-04 This guide provides hardware model-specific guidance in server configuration, with BIOS and RAID configuration instructions for the Dell R710. This guide is part of a multi-volume
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec ASR-4000/ASR-4800SAS/ASR-4805SAS RAID Controllers Adaptec AAR-2420SA/AAR-2820SA SATA RAID Controller Adaptec ASR-2130SLP/ASR-2230SLP SCSI RAID Controller as of October 20, 2006 Please
Intel ESB2 SATA RAID Setup Guidelines
Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines After all the hardware has been installed, you must first configure Intel ESB2 SATA RAID Settings before you install the Windows
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista TM / Vista
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
4-1-4 Serial ATA SATA. A. Intel ICH8R (1) SATA (1) SATA (2) BIOS SATA (3) RAID BIOS RAID (4) SATA (5) SATA
4-1-4 Serial ATA (1) (2) BIOS (3) RAID BIOS RAID ( ) (4) (5) (a) ( RAID ) (b) (c) Windows XP 2000 (d) A. Intel ICH8R (1) ( ) ( ) RAID - 69 - (2) BIOS BIOS 1 BIOS POST (Power-On Self Test ) BIOS CMOS
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines After all hardware has been installed, you must fi rst confi gure the Intel SATA HostRAID settings
Installing the Operating System or Hypervisor
Installing the Operating System or Hypervisor If you purchased E-Series Server Option 1 (E-Series Server without preinstalled operating system or hypervisor), you must install an operating system or hypervisor.
VIA Fedora Linux Core 8 (x86&x86_64) VT8237R/VT8237A/VT8237S/VT8251/CX700/VX800 V-RAID V3.10 Driver Installation Guide
VIA Fedora Linux Core 8 (x86&x86_64) VT8237R/VT8237A/VT8237S/VT8251/CX700/VX800 V-RAID V3.10 Driver Installation Guide 1. Summary Version 0.8, December 03, 2007 Copyright 2003~2007 VIA Technologies, INC
PC Workstation 2015 RAID Service Guide
Introduction PC Workstation 2015 RAID Service Guide This document lists the SATA Disk Drives approved for use in the PCWS 2015 including RAID, suggestions for determining which drive in a mirrored pair
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
English. Configuring SATA Hard Drive(s)
Configuring SATA Hard Drive(s) To configure SATA hard drive(s), follow the steps below: (1) Install SATA hard drive(s) in your system. (2) Configure SATA controller mode and boot sequence in BIOS Setup.
System Area Manager. Remote Management
System Area Manager Remote Management Remote Management System Area Manager provides remote management functions for its managed systems, including Wake on LAN, Shutdown, Restart, Remote Console and for
Computer Setup (F10) Utility Guide HP Compaq dx2200 Microtower Business PC
Guide HP Compaq dx2200 Microtower Business PC Document Part Number: 413759-001 January 2006 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer
Mother Board Component
Mother Board Component Explain Introduction Mother Board Component 1.Clock Generator 2. CPU socket 3. Memory Socket Memory error checking 4. ROM Bios 5. CMOS Ram 6. Battery 7. Chipset 8. Expansion Slot
Using Dell Server Diagnostic Tools
Troubleshooting Enterprise Production Environments Using Dell Server Diagnostic Tools Dell server diagnostic tools are designed to enhance fault isolation and root-cause analysis in enterprise production
Fujitsu LifeBook S Series
Fujitsu LifeBook S Series BIOS Guide LifeBook S Series Model: S7220 Document Date: 07/08/2008 Document Part Number: FPC58-1920-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook S Series BIOS S Series
2-Serial/1-Parallel Port PCI Adapter RC303 User Manual
Overview This PCI I/O card is a dual UART with 1284 printer interface port controller with PCI bus interface and uses an all-in-one solution from NeMos Technology, which provides superior performance and
Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3
Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3 1.1 UNDERSTANDING RAID CONCEPTS... 3 1.2 OVERVIEW OF DC-200 RAID CARD... 3 1.2.1 Features and specifications of the DC-200 RAID card... 5
Cisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Computer Setup (F10) Utility Guide Business Desktops
Guide Business Desktops Document Part Number: 361206-002 September 2004 This guide provides instructions on how to use Computer Setup. This tool is used to reconfigure and modify computer default settings
Windows 2008 Server Installation
PCS Tech Tips Windows Server 2008 Install Windows 64-bit Foundation Server HP Proliant ML310G5p Embedded SATA RAID Controller Copyright 2010 Practical Computer Solutions, Inc. 1 2 Overview of Installation
General FAQ s E-Pos Systems.
General FAQ s E-Pos Systems. Q1. To install ELO touch screen, why does E-Touch Pro (B55 M/B) work fine in Windows but fail in DOS? Q2. Why can't the Touch screen driver work on Win XP? Q3. I installed
SOFTWARE TECHNOLOGIES
SOFTWARE TECHNOLOGIES (September 2, 2015) BUS3500 - Abdou Illia, Fall 2015 1 LEARNING GOALS Identify the different types of systems software. Explain the main functions of operating systems. Know the various
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
BIOS Award v6.00pg BIOS setup guidelines
BIOS The BIOS setup, also called CMOS setup, is a crucial part of the proper setting up of a PC the BIOS (Basic Input Output System) tells the operating system the characteristics of the main basic components
HP ProLiant ML110 Server Network Operating System Installation Guide
HP ProLiant ML110 Server Network Operating System Installation Guide January 2004 (First Edition) Part Number 344-535-001 Regulatory Model Number HSTNS-3100 2004 Hewlett-Packard Development Company, L.P.
Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.
1. Introduction Onboard-RAID IEI s Onboard-RAID is designed with Promise IDE RAID controller to provide a cost-effective, high performance RAID that adds performance and/or reliability to systems using
Commonwealth of Virginia Virginia Information Technologies Agency GATEWAY DESKTOPS, NOTEBOOKS & SERVERS. Optional Use Contract
Commonwealth of Virginia Virginia Information Technologies Agency GATEWAY DESKTOPS, NOTEBOOKS & SERVERS Optional Use Contract Date: September 12, 2008 Contract #: Authorized User: Contractor: VA-030801-GATE
VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.
VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED. Starting Vmware Workstation Go to the start menu and start the VMware Workstation program. *If you are using
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.
RocketRAID esata 3G HBA Series Bootable RAID Installation Guide. Overview: This installation guide provides step and step instructions on how to configure the RocketRAID esata 3G storage to support booting
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Using ATI Array Management Software (WebPAM)
Redundant Array of Independent Disks (RAID) on HP Compaq dc5750 Business PCs Using ATI Array Management Software (WebPAM) Introduction............................................................ 2 Mirroring
V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.
V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation. REVISION A DATE: 10/01/2009 CA3000 Software Installation Procedure Continental Access and
Hardware & Software Specification i2itracks/popiq
Hardware & Software Specification i2itracks/popiq 3663 N. Laughlin Rd., Suite 200 Santa Rosa, CA 95403 866-820- 2212 www.i2isys.com 1 I2iSystems Hardware and Software Specifications Revised 04/09/2015
Sophos UTM Software Appliance
Sophos UTM Software Appliance Quick Start Guide Product version: 9.300 Document date: Monday, December 01, 2014 Sophos UTM Minimum Hardware Requirements Intel compatible CPU 1.5 GHz+ 1 GB RAM (2 GB recommended)
SATA+Ultra ATA RAID CONTROLLER RC212. User Manual
SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID
Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual
Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual Contents For AP v2.10.0.0 Release For Windows 98/ME/2000/XP Version 1.1B (08/27/2004) Contents...1 Introduction...1 Features & Specifications...2
A Comparison of VMware and {Virtual Server}
A Comparison of VMware and {Virtual Server} Kurt Lamoreaux Consultant, MCSE, VCP Computer Networking and Consulting Services A Funny Thing Happened on the Way to HP World 2004 Call for speakers at the
How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)
4-1-4 Configuring SATA Hard Drive(s) To configure SATA hard drive(s), follow the steps below: (1) Install SATA hard drive(s) in your system. (2) Configure SATA controller mode and boot sequence in BIOS
V2.8.x Installation on a Database Server Note: This document is to be used on a new database server installation.
V2.8.x Installation on a Database Server Note: This document is to be used on a new database server installation. REVISION A DATE: 10/5/2011 CA3000 Software Installation Procedure Continental Access and
Promise FastTrak 100-Lite RAID Controller
Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted
Minimum Hardware Specifications Upgrades
Minimum Hardware Specifications Upgrades http://www.varian.com/hardwarespecs ARIA for Medical Oncology, & ARIA for Radiation Oncology Version 13.0 1 ARIA Version 13.0 Minimum Hardware Specifications Minimum:
2001 Acer Incorporation. All rights reserved. This paper is for informational purposes only. ACER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS
Acer Altos Server Installation and Configuration Guide for Microsoft Server Clustering on Acer Altos Servers, Altos RS710, Altos S300, and LSI MegaRAID Elite/Enterprise 1600 Controllers This installation
4 Processor/4U-P System. Information Update
4 Processor/4U-P System Information Update Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential
HP BUSINESS NOTEBOOK PC F10 SETUP OVERVIEW
HP BUSINESS NOTEBOOK PC F10 SETUP OVERVIEW 2011 Business Notebook Models Technical white paper Table of contents Executive summary... 2 System requirements... 2 Supported models... 2 Enhancements... 2
Figure 1A: Dell server and accessories Figure 1B: HP server and accessories Figure 1C: IBM server and accessories
TEST REPORT SEPTEMBER 2007 Out-of-box comparison between Dell, HP, and IBM servers Executive summary Dell Inc. (Dell) commissioned Principled Technologies (PT) to compare the out-of-box experience of a
Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools
Terminal Server Software and Hardware Requirements Datacolor Match Pigment Datacolor Tools January 21, 2011 Page 1 of 8 Introduction This document will provide preliminary information about the both the
Proof Point: Example Clustered Microsoft SQL Configuration on the HP ProLiant DL980
Technical white paper Proof Point: Example Clustered Microsoft SQL Configuration on the HP ProLiant DL980 Table of contents Introduction 2 Server Configuration 3 Microsoft SQL Server Overview 3 Network
QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview
Overview Front 1. Power Button 2. Power Indicator Light 3. Hard Disk Drive Indicator Light 4. Optical Disk Drive Ejection Button 5. Media Card Reader Indicator Light 6. 7-in-1 Media Card Reader (optional)
-------------------------------------------------------------------- README.TXT
README.TXT ICP ICP9085LI/ICP5085BR SAS RAID Controller ICP ICP9047MA/ICP9087MA SATA RAID Controller ICP ICP9014RO/ICP9024RO SCSI RAID Controller ICP ICP5805BL/ICP5045BL/ICP5085BL/ICP5125BR/ICP5165BR Unified
Trademarks. IBM, PC/AT, and PC/XT are trademarks of International Business Machines Corporation.
The information presented in this publication has been carefully checked for reliability; however, no responsibility is assumed for inaccuracies. Specifications are subject to change without notice. Trademarks
System Release Notes Express5800/320LB System Release Notes
System Release Notes Express5800/320LB System Release Notes PN: 455-01681-004 2 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related
WebBIOS Configuration Utility Guide
Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC WebBIOS Configuration Utility Guide www.dell.com support.dell.com Information in this document is subject to change without notice.
Configuring and Using AMT on TS140 and TS440
Configuring and Using AMT on TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES THIS PUBLICATION
EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0
EUCIP IT Administrator - Module 1 PC Hardware Syllabus Version 3.0 Copyright 2011 ECDL Foundation All rights reserved. No part of this publication may be reproduced in any form except as permitted by ECDL
HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide
HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide Important information on installing the Windows XP Operating System on HP Z220, Z420, Z620 and Z820 Workstations.
85MIV2 / 85MIV2-L -- Components Locations
Chapter Specification 85MIV2 / 85MIV2-L -- Components Locations RJ45 LAN Connector for 85MIV2-L only PS/2 Peripheral Mouse (on top) Power PS/2 K/B(underside) RJ45 (on top) +2V Power USB0 (middle) USB(underside)
Fujitsu LifeBook A Series
Fujitsu LifeBook A Series BIOS Guide LifeBook A Series Model: A6110 Document Date: 10/05/2007 Document Part Number: FPC58-1808-01 FUJITSU COMPUTER SYSTEMS CORPORATION 1 LifeBook A Series BIOS A Series
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista / Vista 64-bit / XP /
Enterprise Erase LAN
Enterprise Erase LAN Network Erasing and Asset Management Server Version 2.0 Users Guide 888.700.8560 toll free www.tabernus.com 11130 Jollyville Rd Suite 301 Austin, TX 78757 Table of Contents 1 Product
Using iscsi with BackupAssist. User Guide
User Guide Contents 1. Introduction... 2 Documentation... 2 Terminology... 2 Advantages of iscsi... 2 Supported environments... 2 2. Overview... 3 About iscsi... 3 iscsi best practices with BackupAssist...
AcerAltos-1200_2CPU_PIII-866. Hardware Certification Report Vendor and Model Information
Seite 1 von 14 Altos 1200 OS Certification Posted by : Belle Chu Contact Author Last Updated : 12/11/2000 04:39:34 AM,,,,,,,,,,,,,, Sun Solaris Altos 1200 AcerAltos-1200_2CPU_PIII-866 Solaris 8 Hardware
Visual UpTime Select Server Specifications
Visual UpTime Select Server Specifications Visual Networks offers two Visual UpTime Select server solutions to meet your organization s needs. Please click the link below to view the required hardware
Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved.
Guest PC for Mac OS X Version 1.6 User Guide Copyright 1996-2005 Lismore Software Systems, Ltd. All rights reserved. Table of Contents About Guest PC... 1 About your Virtual Computer... 1 Creating a Virtual
SATA II 4 Port PCI RAID Card RC217 User Manual
SATA II 4 Port PCI RAID Card RC217 SATA II 4 Port PCI RAID Card This Manual is for many Models of SATAII RAID5 HBA that uses Silicon Image SATA II SiI3124 chipset: 1) 32bit PCI bus host card 2) 64bit PCI-X
Dell PowerEdge T110 II Systems. Owner s Manual. Regulatory Model E11S Series Regulatory Type E11S002
Dell PowerEdge T110 II Systems Owner s Manual Regulatory Model E11S Series Regulatory Type E11S002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better
Serial ATA 2 Ports PCI Host
Serial ATA 2 Ports PCI Host This Manual is for the various Model of 2ports SATA HBA: Model A: Low Profile Serial ATA Internal 2 Ports Model B: Low Profile External 1 Port + Internal 1 Port Model C: Low
Q2000 Series BIOS BIOS SETUP UTILITY
BIOS SECTION Q2010 LifeBook Q2000 Series BIOS Q2000 Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your notebook. Your BIOS is set at the
M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual
Serial ATA and Parallel ATA Host Controller Rev. 0.96 December 03, 2003 Copyright 2003 ULi Electronics Inc. All rights reserved. COPYRIGHT NOTICE All information in this document is considered ULi Electronics
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers
Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers Enterprise Product Group (EPG) Dell White Paper By Todd Muirhead and Peter Lillian July 2004 Contents Executive Summary... 3 Introduction...
How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
Intel Desktop Board D925XECV2 Specification Update
Intel Desktop Board D925XECV2 Specification Update Release Date: July 2006 Order Number: C94210-005US The Intel Desktop Board D925XECV2 may contain design defects or errors known as errata, which may cause
How to Install Microsoft Windows Server 2008 R2 in VMware ESXi
How to Install Microsoft Windows Server 2008 R2 in VMware ESXi I am not responsible for your actions or their outcomes, in any way, while reading and/or implementing this tutorial. I will not provide support
Fujitsu LIFEBOOK T Series
Fujitsu LIFEBOOK T Series BIOS Guide LIFEBOOK T Series Model: T731 Document Date: 6/23/2011 Document Part Number: FPC58-2898-01 FUJITSU AMERICA, INC. 1 LIFEBOOK T731 BIOS T Series BIOS BIOS SETUP UTILITY
Parallels Desktop for Mac
Parallels Software International, Inc. Parallels Desktop for Mac Quick Start Guide 3.0 (c) 2005-2007 Copyright 2006-2007 by Parallels Software International, Inc. All rights reserved. Parallels and Parallels
How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (
SiS964/SiS180 SATA w/ RAID User s Manual Quick User s Guide Version 0.3 Edition December 2003 Copyright 2003 Silicon Integrated Systems Corp. Trademarks SiS is a registered trademark of Silicon Integrated
SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3
SiS964/SiS180 SATA w/ RAID User s Manual Quick User s Guide Version 0.3 Edition December 2003 Copyright 2003 Silicon Integrated Systems Corp. Trademarks SiS is a registered trademark of Silicon Integrated
HP Server tc2120 Network Operating System Installation Guide
HP Server tc2120 Network Operating System Installation Guide For: Microsoft Windows 2000 Server and SP3 Microsoft Windows 2000 Server and Microsoft Small Business Server 2000 Microsoft Windows 2003 Server
Marvell SATA3 RAID Installation Guide
Marvell SATA3 RAID Installation Guide Overview The Marvell RAID Utility (MRU) is a browser-based graphical user interface (GUI) tool for the Marvell RAID adapter. It supports IO Controllers (IOC) and RAID-On-Chip
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
Electronic Emission Notices
1 Electronic Emission Notices Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC