Contents Page 1, type FA1 1.1 Function description................................................................................... 6 1.2 Pre requisites............................................................................................. 8 1.3 Specification............................................................................................. 10 1.4 Standard delivery....................................................................................... 10 1.5 Application examples.................................................................................. 12 1.6 Hooking up additional functions................................................................... 14 2 Vitocom 300, type FA2 2.1 Function description................................................................................... 16 2.2 Pre requisites............................................................................................. 18 2.3 Standard delivery....................................................................................... 20 2.4 Specification............................................................................................. 22 2.5 Application examples.................................................................................. 23 2.6 Hooking up additional functions................................................................... 26 2.7 Emergency power supply connection............................................................ 27 3 Vitocom 300, type FA3 and FI1 3.1 Function description................................................................................... 28 3.2 Pre requisites............................................................................................. 30 3.3 Standard delivery....................................................................................... 32 3.4 Specification power supply unit................................................................ 34 3.5 Specification basic module........................................................................ 35 3.6 Specification expansion module................................................................. 39 3.7 Accessories................................................................................................ 43 3.8 Application examples.................................................................................. 45 3.9 Hooking up additional functions................................................................... 46 4 Vitodata 300 4.1 Function description................................................................................... 48 4.2 Pre requisites............................................................................................. 50 4.3 Application examples.................................................................................. 51 5 Vitosoft 200, type LG1 and LG2 5.1 Function description................................................................................... 52 5.2 Pre requisites............................................................................................. 52 5.3 Specification BUS de coupler BEK.............................................................. 56 5.4 Standard delivery....................................................................................... 56 5.5 Application examples.................................................................................. 58 6 Vitocom 200, type LNR 6.1 Function description................................................................................... 60 6.2 Pre requisites............................................................................................. 62 6.3 Standard delivery....................................................................................... 64 6.4 Application examples.................................................................................. 65 Vitosoft 200 Vitodata 300 Vitocom 300 7 Vitocom 200, type EIB 7.1 Function description................................................................................... 66 7.2 Pre requisites............................................................................................. 66 7.3 Standard delivery....................................................................................... 68 7.4 Specification............................................................................................. 70 8 Vitocom 200, type LON 8.1 Function description................................................................................... 72 8.2 Pre requisites............................................................................................. 72 8.3 Standard delivery....................................................................................... 74 8.4 Specification............................................................................................. 75 Vitocom 200 9 LON network 9.1 Connection of Viessmann equipment via LON................................................ 76 9.2 Application examples.................................................................................. 77 5
, type FA1 1.1 Function description 1.1 Function description Introduction The Viessmann communication interface, type FA1, is used for remote messaging, monitoring and scanning for faults, as well as remote switching of heasting systems via the telephone network. Configuration of using: Telephone using multi frequency process (DTMF) D1/D2/E Plus mobile phone Vitodata 300 Using the integral modem, error messages are transferred via telephone systems to various communication services: Remote monitoring with Vitodata 300 *1 Fax D1/D2 mobile phone Summary provides the following functions: Remote monitoring and control of heating system via the telephone system. Remote interrogation of operating conditions or control conditions via the telephone system. Automatically generated messages to a fax machine, a D1/D2 mobile phone via the public telephone network or via Vitodata 300 (heating or service contractor). Optional hook up of additional functions, e. g. opening and closing window shutters or switching the domestic lighting on or off via the telephone system. Advantages Irregularities in the operation of heating systems can be recognised and notified as soon as first signs appear. This ensures higher operational safety. An automatic message regarding the cause of the error by the system guarantees rapid and specific troubleshooting. Heating programs can be changed for each heating circuit by remote control using the telephone system. Energy savings can be conveniently achieved by changing heating programs at appropriate times. Automatic initiation of service and maintenance work. Saving system descriptions, system specific details and message texts. *1 SMS for E Plus Netz only via Vitodata 300. 6
, type FA1 1.1 Function description A B C D E A Telephone with DTMF B D1/D2/E Plus *1 mobile phone C Fax D Control centre E Database server with Vitodata 300 (internet) Communication services Viessmann products *1 SMS for E Plus Netz only via Vitodata 300. 7
, type FA1 1.2 Pre requisites 1.2 Pre requisites On site pre requisites Analogue telephone connection with RJ11 socket TAE socket, code "6N" Heating systems with Vitotronic Vitotronic 150, type KB1, Vitotronic 200, type KW1 and KW2 or Vitotronic 300, type KW3 Heating system with Vitodens or Vitopend Vitodens 100, 200 or 300 with control units for weather compensated operation or Vitopend 200 with control unit for weather compensated operation Heating system with Dekamatik Dekamatik Depending on the required function: Connection cable with junction box for control error notification. Heating system with Viessmann Trimatik (from serial no. with index B or date of construction January 1998 onwards) Viessmann Trimatik Depending on the required function: Connection cable with junction box for control error notification Control module FT for changing the heating program *1. Heating system with Viessmann Trimatik *2 (year of construction prior to January 1998) Viessmann Trimatik, part no. 7450 285, 7450 286, 7450 365 and 7450 367 Depending on the required function: Programming unit as remote control with wall mounting frame for connecting one Control module FT for changing the heating program *1. Heating system with Viessmann Trimatik *2 (year of construction prior to January 1998) Viessmann Trimatik MC, part no. 7450 261 A and 7450 263 or Viessmann Trimatik MC/B, part no. 7450 361 or Viessmann Trimatik MC/B2, part no. 7450 362 and 740 362 A Depending on the required function: Control module FT for changing the heating program *1. Heating system with Eurola or Pendola Eurola with Eurolamatik OC or Pendola with control unit for weather compensated operation In addition for Pendola: Adaptor (connection extension, part no. 7404 582). Remote interrogation, remote switching via the telephone system using a telephone with the dual tone multi frequency (DTMF) method via D1/D2/E Plus mobile phone via Vitodata 300 (internet). Remote monitoring via D1/D2 mobile phone via Fax via Vitodata 300. *1 Not possible when using remote control. *2 With on site hook up. 8
, type FA1 1.2 Pre requisites Heating systems with Vitotronic 150, 200, 300, Vitodens 100, 200, 300 or Vitopend 200 A B C D E K F G A Telephone with DTMF B D1/D2/E Plus *1 mobile phone C Fax D Control centre E Database server with Vitodata 300 (internet) F Telephone connection G Control unit H KM BUS cable K 145 H Heating systems with Dekamatik or Viessmann Trimatik A B C D K F G E H A Telephone with DTMF B D1/D2/E Plus *1 mobile phone C Fax D Control centre E Database server with Vitodata 300 (internet) F Telephone connection G Programming unit with wall mounting frame H Control unit K 58 *1 SMS for E Plus Netz only via Vitodata 300. 9
, type FA1 1.3 Specification 1.4 Standard delivery 1.3 Specification Specification Rated voltage: 230V~ Rated frequency : 50Hz Rated current: 15 ma ~ Protection: II Protection level: IP 20 acc. to EN 60 529 safeguard through appropriate design and installation Function: Type 1B according to EN 60 730 1 Permissible ambient temperature in use: 0 to +40 ºC Installation in living accom modation and boiler rooms (normal ambi ent conditions) during storage and transport: 20 to +65 ºC Approval: CTR 21 Location Note the maximum cable length when selecting a location for installation (see below). On site connections Dimensions Fault input DE1, 230 V ~ Fault input DE2, 230 V~ Switch output DA3, Volt free 0.5 A 24 V /~ 1.4 Standard delivery Incl. 2 m long mains cable, 3 m long connection cable with RJ11 plug for telephone socket, adaptor RJ11/TAE6N and 3 m long KM BUS cable with plug avg. 10
, type FA1 1.4 Standard delivery A = standard delivery A Terminal adapter for communication service *1 B Telephone socket C Telephone plug RJ11 D Adaptor RJ11/TAE6N E Control unit B C D 1 E 145 2 145/X5/58 Item Description Part no. 1 with mains cable, telephone cable and adaptor RJ11/TAE6N 7142 057 2 KM BUS cable for connection to the control unit Accessories Description Number Part no. Adaptor (connection extension, in conjunction with Pendola) 1 7404 582 KM BUS distributor (in conjunction with Vitotronic 150, 200 and 300 for several KM BUS users) 1 7415 028 Control module FT (in conjunction with Viessmann Trimatik) 1 7450 535 Connection cable, approx. 0.8 m long (in conjunction with Dekamatik or Viessmann Trimatik) 1 7450 061 *1 Equipment and quantity in accordance with the required functions. 11
, type FA1 1.5 Application examples 1.5 Application examples Remote interrogation and remote switching via telephone Remote interrogation and remote switching A heating system can be switched on from any telephone via. Remote interrogation and remote switching is activated by transmitting commands in the form of a sequence of figures. First dial up. Then enter the access codes and the respective codes for remote interrogation and remote switching via the telephone keypad. translates the transmitted code and switches the control unit or responds to remote interrogation with acoustic signals. Example: You want to discover the error state of Vitotronic 300, type KW3. Enter the respective key combination after the connection has been established and the access code has been entered. If a central fault message is present, transmits a deep dual tone sequence; if no central fault message is present, a high pitched quad tone sequence is transmitted. Remote switching of a heating system using Vitotronic heating program pre selection for specific boiler circuits Vitodens and Viopend: heating program pre selection Dekamatik: The heating program is changed depending on the heating program selected at the control unit Viessmann Trimatik: The remote switching of the operating program via the control module FT is transferred to the switch output of. A burner fault message is directly placed on a fault input of by the burner connection of Viessmann Trimatik. A B C A B Telephone with DTMF C Mobile phone Remote monitoring with D1/D2 mobile phone The control unit recognises any faults developed by the heating system or the control unit, e. g. on sensors, on the burner or the circuit board. Information about this fault is then transmitted by the A control unit to Vitocom 100 via the connection cable. Vitocom 100 dials the programmed D1/D2 telephone number. Vitocom can store additional system information. B A B D1/D2 mobile phone 12
, type FA1 1.5 Application examples Remote monitoring by fax Remote monitoring by fax is enabled through the transmission of error messages in plain text. The control unit recognises any faults developed by the heating system, e. g. on A sensors, at the burner or the printed circuit board. The error message is then transmitted by the control unit via the connection cable, which then dials the programmed fax number. Vitocom can store additional system information. B Viessmann Vitocom 714205700001107 A B Fax Recipient: Messrs. Klaus Steinmann Am Haupttor 34 35107 Battenberg/Eder Tel.: 06999/13735 System message: FAULT Vitotronic300 Burner fault System operator: Mr Wilfried Born Untermarkt 2 35066 Frankenberg/Eder Tel.: 06999/67890 System: Vitola 200, 63 kw Vitocell 300, 500 litres Vitotronic 300 in conjunction with Message end 13
, type FA1 1.6 Hooking up additional functions 1.6 Hooking up additional functions The following connections for hooking up on site components are provided in the connection box: 2 fault inputs DE1 and DE2 1 switched output DA3 Fault inputs DE1 and DE2 Using these inputs, on site faults can be hooked up with 230 V ~ as mains voltage signals. Input signals are monitored by Vitocom 100 and notified as faults. Input signals may be interrogated via the central control, telephone with DTMF or code transmitter via D1/D2/E Plus mobile phone. Example: Error message from cooling, lifting and ventilating systems and central fault messages from one control panel. Switched output DA3 (volt free relay contacts, rated capacity 0.5 A, 24 V safety voltage acc. to EN 61 558). The external heating program changeover of the control unit can be switched with this switched output DA3. On site components (e. g. lighting) may also be switched via this output. The output may be switched via the central control, telephone with DTMF or via D1/D2/E Plus mobile phone. Connect on site components to the switched output DA3 : A B 230/12 V A terminal box B Contactor relay 14