EPCOR Distribution & Transmission Inc.



Similar documents
Exshaw Oil Corporation

Pivot Data Centres Inc.

ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas

Electric Power Plant Facilities Process Guidelines July 25, 2014

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

ALBERTA ENERGY AND UTILITIES BOARD Calgary Alberta

ICM Project Station Infrastructure and Equipment

Electric system improvements near you South and West of Edmonton Area Transmission Development

Addendum #2 Contract UK-11-13

Fusible Disconnect Switch

Medium voltage arc flash eliminator units VAM 3ED,

SECTION 5.15 ELECTRICITY AND NATURAL GAS

Contents. Description. Product Selection Guide

Distribution Substation Manual (DSM) Section I - Introduction

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

6. The estimated costs here do not include any applicable ITCC tax

Top Commercial / Residential Electrical Requirements *

Circulating Current Relay. Type IRXm

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited

EXHIBIT A LOCATION MAP AND LAND USE INFORMATION

CITY OF GLENDALE CALIFORNIA REPORT TO CITY COUNCIL

TITLE HERRIMAN HILLS OPEN SPACE INITIATIVE TEXT

Hyperlinks are Inactive

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

Electrical Engineering

Trip circuit supervision relay. Type RXTCS

Technical Guide. SKM Arc Flash Line Side vs. Load Side

MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED

16 West Coast Regional Plan

Proposed Heavy Equipment (Nortrax) Sales & Service Facility

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

School District Design and Project Management For Rochester, NY

The City of Red Deer

Report to the Minister Responsible for the Qulliq Energy Corporation. Respecting:

CIP Physical Security. Nate Roberts CIP Security Auditor I

Foothills Area Transmission Development South Calgary - Project Overview

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

METERING CODE. Energy Market Authority of Singapore

Choosing the Best Solution for Reducing Arc Energy

AUC Electronic Filing Services

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1

Licensed Driving Instructor Requirements

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

Power Plant Electrical Distribution Systems

ENMAX Power Corporation

COMPLIANCE REVIEW OF 2006/07 ASSET MANAGEMENT PLAN. Top Energy Limited

June 24, Notice of Proposed Construction Project Pursuant to General Order 131-D, Weymouth 66/4 kv Substation Project

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Dillon Consulting Limited. Invenergy Solar Canada ULC. Woodville Solar Farm Renewable Energy Approval (REA) Draft Project Description Report

Typical Data Requirements Data Required for Power System Evaluation

Preliminary Information Memorandum. Thanet Offshore Transmission Assets. July 2009

March Prepared by: Irvine Ranch Water District Sand Canyon Avenue. Irvine, CA Contact: Natalie Likens (949)

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Engineering innovation

Electrical Distribution Services for Mining and Metals Industries

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

POWER CORPORATION Requirements for Distribution Wires Access

Networks. ESB Networks Ltd Basis of Charges for Connection to the Distribution System. Commercial and Customer Asset Management ESB Networks Ltd.

Eldorado-Ivanpah Transmission Project WELCOME To Southern California Edison Company s Eldorado-Ivanpah Transmission Project OPEN HOUSE

Arc Terminator Active Arc-Resistant Switchgear

Electrical System Studies

Power products and systems. Intelligent solutions for power distribution Zone concept

Calgary LRT Network Plan

HARDWICK TOWNSHIP WARREN COUNTY, NEW JERSEY

ELECTRICIAN TRADE REGULATION

SPP Notification to Construct

8.0 ENVIRONMENTAL PROTECTION MONITORING AND FOLLOW-UP

DEVLOPMENT APPLICATION PROCEDURES

THE LEONARDO BUILDING crawley business quarter gatwick THE LOWEST COST PER WORK STATION IN THE SOUTH-EAST

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

RCP2 Portfolio Overview Document

DAYBREAK ATTACHED RESIDENCE DISCLOSURE STATEMENTS Acknowledgement of Receipt Form

2012 Capital Expenditure Status Report NP 2013 CBA Capital Expenditure Status Report

Primary and Secondary Electrical Distribution Systems

Session Four: Internal Arc Safety in New and Existing Switchgear

STAFF REPORT. December 20, North District Community Council. Director of Community Planning - North

Earthing Guidance Notes

Sustainable Building Policy

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD

Imperial Oil Limited 237 Fourth Avenue S.W. Calgary, Alberta T2P 3M9 imperialoil.ca

J W Spencer School of Electrical Engineering, Electronics and Computer Science

Proceedings of the 38th Hawaii International Conference on System Sciences

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Engineering Series Ratings: Is It Practical?

An Information Booklet Addressing PCB-Containing Materials in the Indoor Environment of Schools and Other Public Buildings

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

The following components are common to most cubicles; this example is an ABB HK cubicle.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

ACS INDOOR SWITCHGEAR

NEW ZEALAND ELECTRICAL CODE OF PRACTICE. for ELECTRICAL SAFE DISTANCES

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Respecting the environment

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

DISTRIBUTION OPERATIONS AND MAINTENANCE

Transcription:

Decision 3478-D01-2015 Victoria E511S Substation Expansion February 17, 2015

Alberta Utilities Commission Decision 3478-D01-2015 Victoria E511S Substation Expansion Proceeding 3478 Application 1610934-1 February 17, 2015 Published by the: Alberta Utilities Commission Fifth Avenue Place, Fourth Floor, 425 First Street S.W. Calgary, Alberta T2P 3L8 Telephone: 403-592-8845 Fax: 403-592-4406 Website: www.auc.ab.ca

Alberta Utilities Commission Calgary, Alberta Decision 3478-D01-2015 Proceeding 3478 Victoria E511S Substation Expansion Application 1610934-1 1 Introduction 1. (EDTI) filed an application with the Alberta Utilities Commission for approval to expand the Victoria E511S substation in the downtown Edmonton area, pursuant to sections 14 and 15 of the Hydro and Electric Energy Act. This application was registered on October 20, 2014, as Application 1610934-1. EDTI, pursuant to Permit and Licence U2011-164, 1 is the operator of the Victoria E511S substation. 2. On December 9, 2014, the Commission issued information requests to EDTI with regard to the environmental site assessment. EDTI responded to the requests on December 19, 2014. 3. On December 15, 2014, the Commission issued a notice of application to potentially affected parties. The Commission issued the notice through direct delivery as well as a postal code drop to residents in the area. The notice was also published on the AUC website. The Commission conducted an information session for interested parties on January 5, 2015, at the Coast Edmonton Plaza Hotel. The Commission received one statement of intent to participate in the proceeding, which was later withdrawn. 2 Discussion 4. EDTI requested approval to expand the Victoria substation in the downtown Edmonton area and construct a new building that would be used to house a new 15-kilovolt (kv) switch gear (the project). The project was driven by the need to reduce the high fault levels on the 15- kv buses at Victoria substation and to reduce the risk of arc flash from the downtown network distribution feeders at Victoria substation. 5. The Victoria substation expansion project is part of a larger project, which is anticipated to be complete in 2017 and is not included in this project. The future work would include: adding a new 15-kV switchgear in the new building; transferring all seven network feeders from the existing switchgear to the new switchgear; and replacing the existing non-arc resistant, outdoor fault filters with indoor arc resistant high-speed fault current limiting devices. 6. EDTI proposed to acquire portions of lots 195 to 197 southwest of the existing Victoria substation to expand the existing substation which is located on lots 232 to 238, Block 4, Plan B3, Subdivision Hudson Bay Reserve, in the northwest quarter of 1 Substation Permit and Licence U2011-164, Application 1607156, Proceeding 1144, April 21, 2011. Decision 3478-D01-2015 (February 17, 2015) 1

Victoria E511S Substation Expansion Section 5, Township 53, Range 24, west of the Fourth Meridian, known municipally as 10520-104 Street N.W., in Edmonton. 7. EDTI did not apply for any new major equipment as stated above and the final major equipment at the Victoria substation is: one 450-megavolt ampere (MVA), 240/72-kV LTC transformer; one 240-kV circuit breaker; four 50/66.7-MVA, 72/14.4-kV transformers; nine 72-kV circuit breakers; and other substation equipment and an enclosure surrounding the substation perimeter as described in the application. 8. As part of the application, EDTI requested that the number of 15-kV circuit breakers be removed from the permit and licence as the quantity of 15-kV breakers is not material to the operation of the bulk transmission system and the 15-kV switchgear is considered to be a minor alteration in accordance with the Electric Transmission Facilities Process Guidelines. 9. EDTI evaluated the following alternative solutions for the project, which were rejected by EDTI due to technical and economic reasons: do nothing; upgrade part of the existing switchgear to meet the fault current levels; install feeder reactors; and replace the existing substation. 10. EDTI conducted a participant involvement program within 800 metres of the proposed substation expansion. The participant involvement program involved the delivery of project-specific information packages to local area occupants, residents and landowners within 800 metres of the proposed project; personal consultation, either face-to-face or telephone conversations with landowners directly adjacent; and an open house held in September 2014. 11. EDTI stated that the project would be located on previously disturbed lands within the city of Edmonton. It also stated that there would be no new impacts to terrain, vegetation, wetlands, wildlife habitats, surface water or air quality. 12. EDTI submitted that the Phase II environmental site assessment was completed in 2009 and 2010 at the project expansion site and polychlorinated biphenyl (PCB) testing occurred in locations known to have operated in the vicinity of electrical equipment, which may have contained PCBs. In all cases, PCBs were non-detectable within a detection limit of 0.2 parts per million. 13. Throughout the consultation, EDTI received concerns from local stakeholders with respect to aesthetics, security, project need, AUC application process, the project-specific information package and specific questions from the City of Edmonton s Office of Emergency Management. EDTI submitted that it addressed the concerns and comments and was not aware of any outstanding objections or concerns. 2 Decision 3478-D01-2015 (February 17, 2015)

Victoria E511S Substation Expansion 14. In response to the Commission s notice, a statement of intent to participate was received from the City of Edmonton. The city stated that the expansion of Victoria E511S substation was adjacent to the Metro Light Rail Transit (LRT) Line and the Victoria substation services some LRT substations. The city raised concerns with how the expansion would affect service to the LRT substation, whether there would be environmental impacts on the Metro LRT Line and whether there would be any electromagnetic interference that could impact the operation of the light rail vehicles. The city withdrew its statement of intent to participate on February 10, 2015, after discussions with EDTI who addressed its concerns. 3 Findings 15. The Commission considered the application pursuant to sections 14 and 15 of the Hydro and Electric Energy Act. 16. The Commission observes that EDTI s participant involvement program was conducted through notification and a personal consultation process and that there are no outstanding objections or concerns. The Commission finds that the participant involvement program meets the requirements of Rule 007: Applications for Power Plants, Substations, Transmission Lines and Industrial Systems Designations and Hydro Developments. 17. The Commission approves the new 15-kV switchgear equipment. As previously stated in DA2014-272, 2 the Commission considers 15-kV circuit breakers to be transmission facilities and should be listed in a substation permit and licence. 18. Furthermore, the Commission is satisfied that no environmental impacts are expected from the proposed substation expansion because the construction is to be located on previously disturbed lands. 19. The Commission has reviewed the application and has determined that the technical, siting, and environmental aspects of the substation expansion project have been met. 20. Based on the foregoing, the Commission considers the project to be in the public interest in accordance with Section 17 of the Alberta Utilities Commission Act. 2 DA2014-272:, Medium Voltage Switchgear Replacement Hardisty substation, Application 1611020, Proceeding 3536, December 5, 2014. Decision 3478-D01-2015 (February 17, 2015) 3

Victoria E511S Substation Expansion 4 Decision 21. Pursuant to section 14, 15 and 19 of the Hydro and Electric Energy Act, the Commission approves the application and grants EDTI the approval set out in Appendix 1 Substation Permit and Licence 3478-D02-2015 February 17, 2015, to alter Victoria E511S substation (Appendix 1 will be distributed separately). Dated on February 17, 2015. Alberta Utilities Commission (original signed by) Neil Jamieson Commission Member 4 Decision 3478-D01-2015 (February 17, 2015)